Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹2.5 Cr
EMD Value
₹1 L
Closing Date
27 Oct 2026, 11:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Superintending Engineer, PWD Bridges,North Circle
Bridges north circle ,Kozhikode
GENERAL 2025 26 Urgent Repair and Rehabilitation works for Anakkayam bridge in M a l a p p u r a m M a n k a d a L A C s i n Malappuram District Repair and Rehabilitation Works General Civil Work
2026_PWD_878146_1
PWD/BR/TR/2746/2022_5_1_1/1
Open Tender
Civil Works - Bridges
Item Rate
365 days
Mankada
Please refer Tender documents.
9 documents required · 9 mandatory
₹8,270
Yes
₹1 L
Yes
9 Oct 2026
9 Oct 2026
29 Oct 2026
9 Oct 2026
27 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Appendix A: Rehabilitation of bridge | |||||
| 1.001 | 12.8.G.1.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. <br> RCC Grade M30 - Using Concrete Mixer <br> | 154.95 | cum | - | - |
| 1.002 | 12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications | 17.05 | MT | - | - |
| 1.003 | OD125217/2021-2022:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto 30.00 m hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work. ( As per DAR 14.72) | 301.5 | sqm | - | - |
| 1.004 | OD271108/2025-2026:Galvanic Sacrificial Prevention of steel by Point anodes:
Providing and fixing sacrificial zinc anode to prevent initialization of corrosion of
reinforcement in adjoining sound concrete due to chloride ingress by installing anodes from
VECTOR Galvashield XPI or equivalent for patches at Min. 2 to 4 anodes / Sq.mt. area of
concrete (spacing of 300 to 700mm), as per manufacturer specification, covered with mortar
with of resistivity less than of parent concrete on the cleaned reinforcement steel as per
manufacturers specification before applying passivation coating at all heights and including of
all material, labour, tools, temporary supports for structures, electricity, plant and machineries,
etc. complete as directed by Engineer-in-charge and/or consultant | 15 | no | - | - |
| 1.005 | OD271109/2025-2026:Polymer Modified Mortar (Pre-Packed): Providing and Applying single component, high strength, fibre reinforced, thixotropic cementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1 day and 45 MPa at 28 days and capable of applying upto 50mm thick in single layer such as Renderoc SP40 of Fosroc or Master Emaco S 348 of BASF or equivalent, to the prepared concrete area for thickness up to 50mm, after applying epoxy resin based bonding coat as per manufacturer?s specification, before the bonding agent becomes tack free, initially by hand and finally finishing the same with trowel carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface on the columns, slabs, beam etc. at all heights, where the thickness of application is less than 50 mm in patches as per specification . Item rate is inclusive of all material including the bond coat, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete and as directed by Engineer-in-charge and/or consultant. (Payment to be made in Sq.M for thickness upto 50mm of PMM for patch area repaired) | 227 | sqm | - | - |
| 1.006 | OD271110/2025-2026:Anchoring main steel and stirrups : Drilling holes of min 4mm larger than new rebar diameter into existing concrete substrate for anchoring of new rebar and depth of Min. 10 times the diameter of rebar and fixing with anchor resin grout Lokfix E (35/55/75) series or Lokfix P or Emfix or chemical anchor material or Masterflow 935 of BASF or equivalent as per NF P 18-831 and NF P 18-836 including cleaning, cutting, fabricating, chemicals, material, labour, tools, temporary supports for structures, electricity, plant and machineries etc. complete as directed by Engineer-in-charge and/or consultant for all heights | 56 | no | - | - |
| 1.007 | OD271111/2025-2026:Anchoring Steel & Shear Connectors:
Drilling holes into existing concrete structure for anchoring of new rebar with 10 mm dia. shear
connectors at 0.5 Mt. c/c (or as per design recommendation) and fixing with anchor resin grout
Lokfix P / Lokfix E 75/55/35 series or Emfix or pure epoxy resin based cartridge form chemical
anchor material or Masterflow 935 of BASF or equivalent as per NF P 18-831 and NF P 18-
836. Drilling hole for diameter: 14 mm, Drilling hole for depth: 100 mm including cleaning,
cutting, fabricating, chemicals, material, labour, tools, temporary supports for structures,
electricity, plant and machineries etc. complete as directed by Engineer-in-charge and/or
consultant for all height | 40 | 1 nos | - | - |
| 1.008 | OD271112/2025-2026:New/Additional steel Reinforcement : Supplying, cutting, fabricating new reinforcement Fe500 for Jacketing, and providing additional steel reinforcement to compensate corroded reinforcement in existing member etc. and fixing with old existing reinforcement which was reduced to 15 % or more of its original diameter as required as provided in original structure and additional steels as directed by EIC and/ or consultant as required tying with 16 gauge annealed binding wire complete as per drawing and specifications for all heights including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete as directed by Engineer in charge and/or consultant (TMT BARS of various size as required) | 129.37 | kg | - | - |
| 1.009 | OD359017/2025-2026:Micro concrete Reinstatement for thickness more than 50mm for RCC members:- Providing and laying of special repair material micro-concrete for reinstatement of members having thickness of repair more than 50mm and jacketing, using Single component, high strength, high flow cementitious micro-concrete having compressive strength minimum of M40 at 28 days such as MasterEmaco 346 or Renderoc RGL / RGS of Fosroc or equivalent, blended with washed saturated surface-dry (SSD), graded, low absorption, high density, aggregates of size 3mm to 10mm at 50% by weight of micro concrete (if thickness is 100mm or more) and water as per data sheet and pouring into the shuttering if required than use birds beak type form work using suitable arrangement or if required using pumping device for uniform flow of Microconcrete. The side shuttering can be removed after Minimum of 24 hours, preferably 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete as directed by Engineer-in-charge and/or consultant. (Payment shall be made in Sq.M for thickness upto 100mm of Microconcrete of area repaired, ) including shuttering work (Only steel reinforcement shall be paid in other relevant items) | 14.56 | sqm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.06 MB
BOQ_1492461.xls
BOQ • 0.34 MB
sbd.pdf
Tender Documents • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .