Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹52.2 L+₹1.0 L (2.00%)Rejected-AOC BASDHOR PT 1 HOUSE NO 404 HAILAKANDI P O PAIKAN P S HAILAKANDI HAILAKANDI 788155 | HAILAKANDI | ASSAM | 788155 | L2 | Rejected-AOC 2nd Lowest Bidder |
Tender Value
₹51.2 L
EMD Value
₹1.0 L
Closing Date
24 May 2023, 2:00 pmClosed
SE PWD Silchar Building Circle Silchar
SE PWD Silchar Building Circle Silchar
Civil, Sanitary Water supply and Electrical Work
2023_PWBNH_30887_1
SBC/CS/2023-24/04/361/Gr-II
Open Tender
Civil Works - Building
Item Rate
270 days
SMCH Silchar
As per NIT
5 documents required · 5 mandatory
₹1,000
₹1.0 L
Yes
SE PWD Silchar Building Circle Silchar
11 Aug 2023
19 May 2023
25 May 2023
19 May 2023
24 May 2023
19 May 2023
19 May 2023 - 24 May 2023
22 May 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
Steel reinforcement for R.C.C. work including straightening, cuttingbending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth 4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural13:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size
Providing and laying in position specified grade of reinforced cementoncrete, excluding the cost of centering, shuttering, finishing upto plinth level 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natura
Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columnspillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural etc.
Centering and shuttering including strutting, propping etc. and removal ete. 5.9.1 Foundations, footings, bases of columns, etc. for mass.
Centering and shuttering including strutting, propping etc. and removal ete. 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal ete. 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level .6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand
15 mm cement plaster on rough side of single or half brick wall ofmix: 13.5.1 -1:4 (1 cement: 4 coarse sand
Cement plaster skirting up to 30 cm height, with cement mortar 1:3(1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 -18 mm thick
Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of steps etc.
Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shadeslaid on 20mm thick cement mortar 1:4 11.41.2 Size of Tile 600x600 mm
Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
Finishing walls with textured exterior paint of required shade : 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqmover and including priming coat of exterior primer applied
Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade 13.60.1 Two or more coats on new work:
Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete. 13.52.1 On steel work
Providing and fixing factory made P.V.C. door frame of size 50x47 mmwith awall thickness of 5 mm, made out of extruded 5mm rigid PVCfoam sheet, mitred at corners and joined with 2 Nos of 150 mm longbrackets of 15x15 mm M.S. square tube, the vertical door frame profiles etc.
Providing and fixing factory made panel PVC door shutter consisting offrame made out of M.S. tubes of 19 gauge thickness and size of 19 mmx 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frameshall have a coat of steel primers of approved make and manufacture. etc. complete
Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285 etc.21.1.1 For fixed portion21.1.1.1 Anodised aluminium (anodised transparentor dyed to required shade according toIS: 1868 etc.
For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the costof EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately) 21.1.2.1 Anodised aluminium (anodised transparentor dyed to required shade according toIS: 1868, Minimum anodic coating of grade
Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. Complete21.3.2 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 etc.
Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position etc. 10.16.3 -Electric resistance or induction butt welded tubes
Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel etc. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheetfixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete. 12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
Providing and fixing in position collapsible steel shutters with verticachannels 20x10x2 mm and braced with flat iron diagonals 20x5 mmsize, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm diasteel pulleys, complete with bolts, nuts, locking arrangement, stoppershandles, including applying a priming coat of approved steel primer.
Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever 17.2.2 W.C. pan with ISI marked black solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the walls ETC.17.7.1 White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes andfittings.
Providing and fixing P.V.C. low level flushing cistern with manuallycontrolled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete. 17.18.1 10 litre capacity - White
Providing and fixing 600x450 mm beveled edge mirror of superiorglass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washerscomplete.
Providing and fixing 3 layer PP-R (Poly propylene Random copolymerpipes confirming to IS:15801 UV stabilized & anti - microbial fusionwelded, having thermal stability for hot & cold water suppLY ETC. 18.6.9 PN - 10 Pipe, 110 mm OD (SDR-11)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymerpipes confirming to IS:15801 UV stabilized & anti - microbial fusionwelded, having thermal stability for hot & cold water suppLY ETC. 18.6.6 PN - 10 Pipe, 63 mm OD (SDR-11)
Providing and fixing water closet squatting pan (Indian type W.Cpan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device etc.. 17.1.1 White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality .and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittingsarrangement of approved quality and colour.17.73.2 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipeshaving thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing .Internal work - Exposed on wall 18.7.2 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipeshaving thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing .Internal work - Exposed on wall 18.7.3 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipeshaving thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing 18.7.5 40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipeshaving thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clamps Concealed work 18.8.1 15 mm nominal dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 : 18.49.1 - 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931.18.52.1 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyserpoints of approved quality conforming to IS:893118.53.1 15mm nominal bore
Rate as per quotation enclosed:- Supply, Installation, fixing of carbon dioxide fire extinguisher confirming to IS: 2878 with ISI Mark. (4.5 liters) Brand: Fire stop/Friend/Fire shield/Getech/Mnimax
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
Steel reinforcement for R.C.C. work including straightening, cuttingbending, placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural13:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columnspillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level5. 2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural etc.
Centering and shuttering including strutting, propping etc. and removal ete. 5.9.1 Foundations, footings, bases of columns, etc. for mass.
Centering and shuttering including strutting, propping etc. and removal ete. 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal ete. 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall ofmix: 13.5.1 -1:4 (1 cement: 4 coarse sand
Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coatwith approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08%and conforming to IS: 15622, of approved make, in all colours and shadeslaid on 20mm thick cement mortar 1:4 11.41.2 Size of Tile 600x600 mm
Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :13.43.1 Water thinnable cement primer
Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade 13.60.1 Two or more coats on new work:
Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285 etc.21.1.1 For fixed portion21.1.1.1 Anodised aluminium (anodised transparentor dyed to required shade according toIS: 1868 etc.
Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasketetc. Complete21.3.2 With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm)
Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position etc. 10.16.3 -Electric resistance or induction butt welded tubes
Providing corrugated G.S. sheet roofing including vertical / curvedsurface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel etc. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheetfixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.limpet and bitumen washers complete. 12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
Demolishing existing Underground BSNL Cable & Chamber and Construction of newly BSNL underground cable line & chamber in consultation with appropriate authority or as directed by the Engineer.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (1.10.1) Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (1.10.2) Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (1.10.3) Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (1.14.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (1.14.3) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (1.14.9) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(1.14.4) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp, 30KA, FPMCCB
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying with fitting fixing of 7 watt LED bulb (Anchore,panasonic make Roma classic.)
Supplying of A/C Ceiling fan of the following sweep model etc. without regulator Eco Ceiling fan 1200mm W/O Reg. white.
Supplying of 300mm sweep Domestic exhaust fan (Orient make).300mm spring Air.
Supplying high efficiency recess mounted white powder coated CRCA housing with full mounted acrylic diffuser (2ftx2ft) 125Lm/W Code No- LVLTUISO36XC 36watt. (Jaguar make).
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required (1.10.1) Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required (1.10.2) Group B
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (1.14.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (1.14.3) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying with fitting fixing of 7 watt LED bulb (Anchore,panasonic make Roma classic.)
Supplying of A/C Ceiling fan of the following sweep model etc. without regulator Eco Ceiling fan 1200mm W/O Reg. white.
Supplying with fitting fixing of 1.5 Ton A/C Machine with all accessories. (As per approved estimate)
Providing U G cable for Expansion of Administrative Block at Silchar Medical College & Hospital, Silchar (As per approved estimate) Laying of U.G. Cable 95mm2-185mm2 UG cable
Providing U G cable for Expansion of Administrative Block at Silchar Medical College & Hospital, Silchar (As per approved estimate) Supplying of 185mm2 3.5 core UG cable
NERESH CHANDRA ROY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .