Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC JYOTIRMAY COLONY WARD NO 32 P O SILIGURI BAZAR P S BHAKTINAGAR SILIGURI JALPAIGURI 734005 | SILIGURI | JALPAIGURI | WEST BENGAL | 734005 | ₹9.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹9.8 LRejected-Finance H 65 8 127 58 SURYA NAGAR SILIGURI 734 006 | SILIGURI | JALPAIGURI | WEST BENGAL | 734006 | ₹9.8 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹9.8 LRejected-Finance RAJA RAMMOHAN ROY ROAD SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹9.8 L | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S. P K ENTERPRISE L3 | M/S KARMAKAR ENGINEERING COMPANY L1 | M/S KUMAR ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | S&D of minimum High Wall inverter type Split Air Conditioner with R410A/ R407C / R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (6.6KW-7.00 KW), Air flow rate (630-875) CFM, suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 25 A Plug Top (Make - Mitsubishi Electric / OGeneral / Mitsubishi Heavy) | 6 | Each | 76,840 ₹4.6 L | 76,700 ₹4.6 L | 76,800 ₹4.6 L |
| 2.00 | S&D of minimum High Wall inverter type Split Air Conditioner with R410A/ R407C / R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (5.2 KW - 5.3KW), Air flow rate (550- 828)CFM,suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 25 A Plug Top. (Make - Mitsubishi Electric / OGeneral / Mitsubishi Heavy) | 3 | Each | 59,785 ₹1.8 L | 59,600 ₹1.8 L | 59,700 ₹1.8 L |
| 3.00 | Installation Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC Machine after making hole in wall etc as per direction of EIC Including making arrangement for outdoor unit by suitable size angle iron frame as per direction of E.L.C | 9 | Each | 2,620 ₹23,580 | 2,600 ₹23,400 | 2,615 ₹23,535 |
| 4.00 | Supply & fixing of 5/8 and 1/4 copper pipe, installation of foam, cable wire (4 core 2.5 sq.mm & 3 core 2.5 sq.mm for connecting ODU & IDU ) & wrapping as required as per direction of EIC to complete the work. | 90 | RM | 799 ₹71,910 | 790 ₹71,100 | 798 ₹71,820 |
| 5.00 | Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of 25 mm dia. incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. | 90 | RM | 83 ₹7,470 | 80 ₹7,200 | 82 ₹7,380 |
| 6.00 | Supplying & fixing of SPN DB (2+10) with IP 43 protection, powder counted, provision for housing DP Contactor, concealed in wall after cutting the wall & mending good the damages to original finish/ on flat iron frame incl painting, connection & earthing attachment incl, following accessories. (Make- Legrand/L&K/ABB)
i) 40 A DP MCB Isolator- 1 no.
ii) 25 A double pole Contractor ML 1.5- 1 no.
iii) Pragrammable Digital time switch- 1 no.
iv) Toggle Switch- 1No
v) LED indicator lamp- 1 set (1 Red & 1 Green)
vi) 20A SP MCB - 1 no.
with complete interconnection and locking arrangement as per direction of E.I.C. | 9 | Each | 9,787 ₹88,083 | 9,780 ₹88,020 | 9,785 ₹88,065 |
| 7.00 | Supply & Fixing 240 V, 25 A, Modular type starter (Make- Legrand/L&K/ABB) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | 9 | Each | 998 ₹8,982 | 990 ₹8,910 | 995 ₹8,955 |
| 8.00Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment | ||||||
| 8.10 | (a) 6 way (Make- Legrand/L&K/ABB) | 1 | Each | 4,461 ₹4,461 | 4,450 ₹4,450 | 4,460 ₹4,460 |
| 9.00Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. | ||||||
Tender Value
Refer Docs
EMD Value
₹19,712
Closing Date
26 Feb 2026, 6:00 pmClosed
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Installation of new split Air Conditioner machines in the Blood Centre, NBMCH, Darjeeling.
2026_WBPWD_1004123_1
WBPWD/EE/DED/e-NIT-87 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
21 days
Siliguri
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,712
11 May 2026
12 Feb 2026
27 Feb 2026
12 Feb 2026
26 Feb 2026
12 Feb 2026
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
WBF2911.pdf
Tender Documents • 0.50 MB
BOQ_2461811.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid