Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC 79 MAHENDRA BANARJEE ROAD BEHALA KOLKATA 700060 | KOLKATA | WEST BENGAL | 700060 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹12.3 L+₹81,473 (7.08%)Rejected-Finance 1080 JESSORE ROAD DUM DUM KOLKATA 700028 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700028 | L2 | Rejected-Finance Due to L2 Bidder |
Tender Value
₹16.8 L
EMD Value
₹33,568
Closing Date
24 Aug 2020, 5:00 pmClosed
Nand Lal Ram
Office of GM (Engg)ER, Operational Complex, AAI, NSCBI Airport, Kolkata
Repairing of Toilets at ATS complex, NSCBI Airport, Kolkata (SH Electrical Works)
2020_AAI_54671_1
Repairing of toilets at ATS Bldg.,kol.(Elect Work)
Open Tender
Electrical Works
Works
60 days
Kolkata Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
Airports Authority of India
₹33,568
25 Sept 2020
11 Aug 2020
1 Sept 2020
12 Aug 2020
24 Aug 2020
12 Aug 2020
12 Aug 2020 - 18 Aug 2020
Amount
Sub Head - 1 (Light Fixtures) Supply of 2'x2' recessed mounted 42W LED luminaire with 5700 K colour temperature, 4600 lumen output, IP20 protection, white power coated CRCA housing with LEDs mounted back lifted tray, LED driver, all prewired, seamless frame with flat acrylic cover etc. complete as required suitable for operation on 230 V+/- 10%, 50Hz, single phase AC supply etc. complete as required and approved by EIC.
Sub Head - 2 (Wiring, MCB, MCBDBs etc.) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x1.5 sq.mm. + 1x1.5 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x2.5 sq.mm. + 1x2.5 sq.mm. earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amps switch.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amps socket.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amps socket.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)
Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Installation, testing and commissioning of prewired, indoor LED fitting of all types (except high bay light, outdoor/street light fittings), complete with all accessories and tube etc. directly on ceiling/ wall/ recess including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Sub Head - 3 (Ventilation duct & Exhaust fan) Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply and Installation of Inline Fan including Canvas connection and making hole in wall and making good the same as required as per instruction of Engineer-in-charge (Make: SPHERE, Capacity - 1030 CFM, 230 Volt, 296 Watt, 1.34 Amps, 2720 RPM or similar).
ANIRBAN ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .