Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹1.1 Cr+₹42,451 (0.40%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | ₹1.1 Cr+₹42,451 (0.40%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹1.2 Cr+₹9.8 L (9.26%)Rejected-Finance | ₹1.2 Cr+₹9.8 L (9.26%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹1.3 Cr+₹20.3 L (19.1%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹1.3 Cr+₹20.3 L (19.1%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹1.5 Cr+₹39.1 L (36.8%)Rejected-Finance | ₹1.5 Cr+₹39.1 L (36.8%) | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
10 Jun 2023, 6:00 pmClosed
Col KK Srivastava, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO B WING OF BUILDING NO P-62 AT INS VIRBAHU UNDER GE (NB) VISAKHAPATNAM
2023_MES_591707_1
82334/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class B
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹2.1 L
Yes
20 Jul 2023
4 May 2023
12 Jun 2023
4 May 2023
10 Jun 2023
27 May 2023
4 May 2023 - 11 May 2023
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 10 KM and not exceeding 15.00 KM complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance exceeding 10.00 KM and not exceeding 15.00 KM complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area not exceeding 100 Sq.cm complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Taking down Chowkats or frames with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frames with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance exceeding 10 KM but not exceeding 15 KM complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 10 KM but not exceeding 15 KM complete all as specified and as directed.
M & L for PCC 1:5:10, Type E-2, using 40mm graded stone aggregate as in Sunken Floors etc complete all as specified and as directed.
Supply only integral water proofing compound [ISI marked] of approved make.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including provision of 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening of Sintex ot its equivalent make as approved by GE complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and as per Manufacturer instructions. Notes: (a) The size of UPVC sections specified in the description of item is minimum requirement. If the same size of section is not available, next higher size shall be provided by the contractor without any extra cost to the Department. However the acceptable tolerance limit for lesser size shall be upto minus 5%. (b)The unit rate quoted by contractor shall exclude S&F of glass but includes all other connected accessories for glazing. (c) Net opening shall be measured for payment purpose.
S & F 5.5mm thick sheet glass, ordinary quality fixed to uPVC joineries complete all as specified and as directed.
S & F in repairs plain Aluminium Sheet Alloy 31000 H4, 0.71 mm thick, cut to size/ shape as required and fixed in position with stainless steel screws, as in covering to doors/ crumple sections, etc. complete all as specified and as directed.
S & F 100 mm size, Butt hinges, stainless steel, medium weight, complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F 150mm long Aluminium anodised Handle, of extruded section Fabricated Type complete all as specified and as directed.
S & F Floor Door Stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
S & F in repairs Door Closer Hydraulically Regulated, Designation No. 3 universal type, suitable for door shutters of 851 mm to 1000 mm in width and of weight between 61 to 80 Kg of aluminium body complete all as specified and as directed.
M & L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting Cement Slurry mixed with Grout Admixture "CONBEXTRA EP 10" of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Batik India Pvt. Ltd. at 225 Grams for 50 KG of cement and applying a coat of Brush Bond RFX of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed at site.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for Non Returnable Grouting Packer of 8mm dia, inserting into concrete by drilling hole of 10 mm dia in a staggared manner as directed by the engineer-in-charge including supply and injection of approved two component low viscosity epoxy grout in position, including all equipment, putty, machinery, tools as recommended by the Manufacturer and making good the surfaces complete all as specified and as directed. Make of epoxy grout: M/s. Fosroc Chemicals/ M/s. Sika India Pvt. Ltd./ M/s. STP Ltd./ M/s. Choksey Chemicals Pvt. Ltd./ M/s Bostik India Pvt. Ltd.
M & L for Drilling Holes In Concrete with suitable equipment in columns, beams, slabs, walls etc. to 15 to 25mm depth as directed by the Engineer-in-charge to facilitate anchoring of reinforcement bars into the core concrete etc. including working platforms, equipment, machines, skilled manpower etc. complete all as specified and as directed. Note: In case reinforcement or coarse aggregate is encountered during drilling holes in concrete, further drilling shall be stopped and holes shall be re-drilled at different location. Failed / suspended drilled holes shall not be considered for measurement and payment.
M & L for preparation of existing exposed steel surfaces free from dust, loose material, surface contamination, rust, scale, mortar, concrete, other loose and deleterious materials, materials which reduce bond or prevent suction or wetting by repair materials, delaminating, weak, damaged and deteriorated concrete by blast cleaning or other means of mechanical abrasion or suitable means, making substrata to Saturated Surface Dry [SSD] with no standing water and applying cement-based epoxy modified three-component anti corrosive coating and bonding slurry using Friazinc R of M/s. Sika India Pvt. Ltd. or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions as in rebar corrosion protection system including all necessary formwork, scaffolding and safety measures complete all as specified and as directed.
M & L for cleaning the existing exposed concrete surfaces and applying Bonding Agent i.e. Sikadur-32 / Sikadur-32 LP of M/s. Sika India Pvt. Ltd. or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions to create structural bonding between old concrete surface and new concrete including all necessary formwork,scaffolding and safety measures complete all as specified and as directed.
M & L for Cleaning the existing exposed reinforcement of slab, beam, column, footing etc. and any other RCC structural member by emery paper, providing two coats of rust remover and rust preventer [Single Component Rust Removal And Rust Inhibition Liquid i.e. Sika Rustoff 100 of M/s. Sika India Pvt. Ltd. or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions] including all necessary formwork,scaffolding and safety measures complete all as specified and as directed. Note: The work shall be executed as per manufacturer’s data sheet and instructions.
M & L for applying Polymer Modified Mortar made using Shrinkage Compensated Polymer Modified Fibre Reinforced Cementitious Repair Mortar such as Renderoc SP 40 of M/s. Fosroc Chemicals India [P] Ltd. or equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions to form average 15 mm thick even surface complete all as specified and as directed.
M & L for Non-Shrink, Cementitious Micro Concrete using Rendroc RG' manufactured by M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. modified with 12mm graded, clean, saturated surface dry crushed stone aggregate in the ratio as per manufacturer's instructions, laid as in columns, beams and similar structural members including use and waste of water tight formwork to facilitate pouring of micro concrete complete all as per manufacturer's instructions including providing double scaffolding and safety measures as required and as specified. [Note: Measurement shall be considered for circumference at centerline of core thickness]
M & L for Carbon Fibre Wrap around outer face of the column & beam for full length complete all as specified herein below and as per manufacturer's specifications / recommendations complete all as specified and as directed: [a] Surface Preparation: The surface shall be thoroughly cleaned with brush and cotton to remove all dust, loose material, surface contamination. Undulations if any noticed shall be brought to uniform surface to make the edges of columns round by applying solvent free, moisture tolerant, thixotropic, structural two-part epoxy adhesive / mortar. [b] Thereafter Wrap Strengthening System shall be applied by using epoxy adhesive on the prepared surface with proper roller to remove air voids as per manufacturer’s instructions. [c] Wrap Strengthening System for Beam & Slab shall be Sika CarboDur of M/s. Sika India Pvt. Ltd. and or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. [d] Wrap Strengthening System for Column shall be Sika Wrap of M/s. Sika India Pvt. Ltd. and or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. [e] Fire Protection Mortar shall be Sikacrete-213 F of M/s. Sika India Pvt. Ltd. and or equivalent approved bonding agent in M/s. Fosroc Chemicals or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. [f] UV Protection System over Sikadur-330 shall be applied.
M & L for providing additional reinforcement using High Strength Corrosion Resistant Deformed Bars of Grade Fe–500D by checking the diameter of the existing bars, cutting the necessary main reinforcement to the required length with proper development length, tying and binding with 16 SWG black soft annealed binding wire / welding where required / lapping / anchoring with the existing shear connectors / reinforcement so that the additional reinforcement acts monolithically with the existing reinforcement and core concrete complete all as specified and as directed. Note: The shear reinforcement shall also be provided as specified here-in-above in the form of 2 "U" shaped bars if existing shear reinforcement is found deteriorated / diameter of the bars is reduced to form a rigid cage and placing with proper cover block, supports, chairs, spacers etc. Diameter of the new bar shall be equal to the existing bars. Additional reinforcement shall be provided only in case the diameter of the existing bars is found less than 25% of the original diameter.
Note for Serial Item No. 26 to 37: The work of structural rehabilitation shall be got carried out under the supervision and guidance of structural consultant who carried out the NDT and submitted report [Andhra University, Visakhapatnam]. A certificate from consultant shall be obtained by the contractor to the effect that work of structural rehabilitation has been carried out under their strict supervision and the same shall be submitted by the contractor to GE. The contractor shall also obtain a written guarantee for effectiveness for a period of 5 [Five] Years from the certified date of completion of entire work from the manufacturer and submit the same to GE before claiming payment. Rate quoted is deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material distance exceeding 10 KM but not exceeding 15.0 KM complete all as specified and as directed. complete all as specified and as directed. Nothing shall be paid extra on this account.
M & L for 25 mm average thick PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in levelling course over sub base, surface finished even and fair to receive topping layer complete all as specified and as directed.
M & L for 40 mm thick PCC 1:2:4, Type B-1, using 20mm graded aggregate mixed with WPC as in Flooring, surface finished even and smooth without using extra cement complete all as specified and as directed. Note:-Water proofing compound will be measured and paid separately.
M & L for 75mm thick PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth with out using extra cement and providing 12mm thick joints for full depth of PCC at every 3.00 m and every change of direction duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade of any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
M & L for Vitrified Tiles, Coloured, Polished, Glazed, Light Shade, Premium Quality, size not exceeding 0.36 Sq.m, 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Coloured, Polished, Glazed, Light Shade, Premium Quality, size not exceeding 0.36 Sq.m, 10 mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade/ design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 8 mm thick [Square or Rectangular] as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 350 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:3, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for preparing newly plastered Wall surfaces by using vaccume based sanding machine and applying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on wall/ ceiling by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on wall/ ceiling surfaces by using vaccume based sanding machine, removal of nails and applying upto 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over two or more coats of Cement based Wall Care Putty [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including rubbing with sand paper to obtain a smooth surface complete all as specified and as directed. Note:- The contractor shall carryout Exterior Emulsion Painting and allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over two or more coats of Cement based Wall Care Putty [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty complete all as specified and as directed. Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicators before commencement of the work to GE for approval.
M & L for Complete removal of existing treatment of any description on wall/ ceiling surfaces by using vaccume based sanding machine, removal of nails and applying upto 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Interior Acrylic Emulsion by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces complete all as specified and as directed. Note:- The contractor shall carryout Interior Acrylic Emulsion painting & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Interior Acrylic Emulsion painting & allied works through their authorised applicators before commencement of the work to GE for approval.
M & L for preparing newly plastered wall surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coats of white washing complete all as specified and as directed.
M & L for preparation of old decorated surfaces of walls, pillasters, etc. including brooming down or steel wire brushing and applying one coat of white wash on wall complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall/ ceiling surfaces by using vaccume based sanding machine, removal of nails, etc. and applying three coats of white wash including necessary preparation of surfaces complete all as specified and as directed.
M & L for One coat of synthetic enamel paint on old painted wooden surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
M & L for One coat of synthetic enamel paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
S & F in repairs UPVC Pipe of 50 mm bore, pressure rating 10 KGf / Sq.cm including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, sockets etc and fixed to walls, ceiling, and laid on floors including testing complete all as specified and as directed.
S & F 16 mm outer diameter CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc., concealed in walls/ ceiling including testing, taking down of existing unserviceable GI pipes and connections of any description complete all as specified and as directed. Note: The rate quoted shall be deemed to include the cost of cutting chases of suitable size and making good.
All as decribed in item No. 61 herein before but 20 mm outer diameter CPVC Pipes
All as decribed in item No. 61 herein before but 25 mm outer diameter CPVC Pipes
All as decribed in item No. 61 herein before but 32 mm outer diameter CPVC Pipes
All as decribed in item No. 61 herein before but 40 mm outer diameter CPVC Pipes
S & F 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls in any position with necessary brackets, clamps, bolts, nuts, etc., including taking up / down unserviceable 100 mm bore cast iron pipes of any description alongwith all fittings including burning out joints and recovering of lead complete all as specified and as directed.
All as decribed in item No. 66 herein before but 110mm bore PVC [SWR] Pipes
All as decribed in item No. 66 herein before but 160mm bore PVC [SWR] Pipes
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
All as decribed in item No. 69 herein before but 110mm bore PVC [SWR] Junction Single [Single "T"]
All as decribed in item No. 69 herein before but 160mm bore PVC [SWR] Junction Single [Single "T"]
All as decribed in item No. 69 herein before but 110mm bore PVC [SWR] Junction Double [Double "T"]
All as decribed in item No. 69 herein before but 160mm bore PVC [SWR] Junction Double [Double "T"]
S & F 110 mm bore PVC [SWR] branch piece, Single [Single "Y"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
All as decribed in item No. 74 herein before but 110mm bore PVC [SWR] branch piece Double [Double "Y"]
S & F 110 mm bore PVC [SWR] bends, any radius including jointing with solvent cement complete all as specified and as directed.
All as decribed in item No. 76 herein before but 160mm bore PVC [SWR] bends
S & F in repairs PVC [SWR] Floor Trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 100mm size Stainless Steel grating for Floor Traps complete all as specified and as directed.
S & F in repairs Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed.
S & F in repairs Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified.
S & F in repairs brass CP Health Faucet with 1 m long flexible tube, wall hook, non return valve complete all as specified.
S & F in repairs Angle Cock, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as per Jaquar Catalogue No. OPP-15053PM or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified
S & F in repairs Wall mixer, 15mm dia, Single Lever cast copper alloy, chromium plated Hot and Cold with provision for connection to Overhead Shower complete with 115mm long bend pipe, connecting legs & wall flange complete [excluding hand & overhead shower] as per Jaquar Catalogue No. CON-273KNUPR or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repars Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and as directed.
S & F in repairs Stop Valves, 15 mm bore dia of pipe, cast copper alloy, Chromium Plated, Fancy Type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and as directed.
S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. OPP-15001PM or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Pillar Cock auto closing system, cast copper alloy, fly-nuts and screwed down for 15 mm bore iron pipe complete all as specified and as directed. Make: Jaquar Cat part No- PRS-031 or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree
S & F in repairs Overhead shower rose of size 125mm, with or without swivel joints, fixed to CPVC pipe complete all as specified and as directed.
S & F in repairs Stainless Steel, Soap Dish, Fancy Type complete all as per Jaquar Catalogue No. AQN-7731 or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Tumbler holder complete as per Jaquar Catalogue No. AQN-7741 or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Stainless steel soap dispenser with mettalic bottle, Fancy type complete all as per Jaquar Catalogue No. ACN-1137N or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Stainless Steel Towel rack 600mm long with Lower Hangers, complete all as per Jaquar Catalogue No. ACN-1181S or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree Shine complete all as specified.
S & F in repairs Stainless steel Towel ring complete all as per Jaquar Catalogue No. ACN-1121BN or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & F in repairs Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed. (Make:-Jaquar cat No. ACN-1111SM or equivalent in Kohler / Cera / Parryware / Grohe / Crabtree
S & F in repairs Vitreous China Urinal, Half Stall Type, Flat Back or Corner Wall Type, White, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, including urinal spreader of PTMT any colours for fixing with 15mm dia pipe and necessary fixing accessories etc. complete all as specified and as directed.
Fixing only in repairs Urinal Partitions of any description and size complete all as specified and as directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern (dual flush), white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.
S & F in repairs Vitreous China Single Piece Wash Down Water Closet [Pedestal Pattern], of White Colour, Rimless Single Piece with UF Soft Close Seat Cover, Tornado Flushing, Hinges, Fixing Accessories and Accessories Set, Cistern Fittings, S Trap-300 mm, PVC Connection of 15mm Bore and 600mm long with Brass Check Nut and Union etc. complete all as specified and as directed. Make: Model No. ONS-WHT-10753P180UFSM of Jaquar or equivalent in Kohler / Roca / Hindware [Italian Collection] / Parryware [Superfine] / Johnson Pedder
S & F in repairs Stainless Steel Toilet Paper Holder, Chromium plated, Fancy type complete all as per Jaquar Catalogue No. AKP-35753PS or its equivalent in Kohler / Cera / Parryware / Grohe / Crabtree complete all as specified.
S & in repairs F Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible waste pipe, PVC Connection of PTMT complete all as specified and as directed.
S & F in repairs Stainless steel kitchen sink with draining board, made of stainless steel sheet of 1 mm thick, with plugs, washers, Waste Fittings, 32 mm dia, Brass, Chromium plated, and 32mm dia PVC flexible Waste Pipe, 750 mm long, including bedding in Cement Mortar to dwarf wall or including fixing cantilever CI Brackets and connecting union to waste pipe, over all size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
Note for Serial Item No. 1 to 103 : The work shall be carried out up to G+9 Floors/ 10 Storey and the rates quoted shall be deemed to be inclusiveof providing double scaffolding and safety measures as required and removal of the same on completion complete all as specified and as directed. Nothing shall be paid extra on this account.
lakshmi Engineering Works
KSN PROJECTS
RAGHU RAMA PANDA
CIVILEC ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .