Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹399.3 CrAccepted-AOC NOT AVAILABLE | NA | NA | 121004 | ₹399.3 Cr | L1 | Accepted-AOC Lowest Rate offered |
| 2 | L2₹414.9 CrRejected-Finance | ₹414.9 Cr | L2 | Rejected-Finance Higher Rate offered |
| 3 | L3₹429.1 CrRejected-Finance D 1 1 GILLANDER HOUSE 8 N S ROAD KOLKATA 700 001 | KOLKATA | WEST BENGAL | 700001 | ₹429.1 Cr | L3 | Rejected-Finance Higher Rate offered |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical A 177 OKHLA INDUSTRIAL AREA PHASE I NEW DELHI 110020 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110020 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹344.3 Cr
EMD Value
₹50 L
Closing Date
16 Feb 2026, 2:00 pmClosed
Addl. General Manager (Engg)-III
DHANA DHANYA AUDITORIUM ALIPORE KOLKATA
CONSTRUCTION OF MAHAKAL MAHATIRTHA IN MATIGARA, SILIGURI, DARJEELING.
2026_HIDCO_987936_1
HIDCO/AGM(E)III/MM/NIT22/25-26
Open Tender
CIVIL WORKS
730 days
Siliguri
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹50 L
HIDCO BHABAN, 3rd floor, Conference Hall
6 Mar 2026
13 Jan 2026
18 Feb 2026
13 Jan 2026
16 Feb 2026
29 Jan 2026
27 Jan 2026
PILING WORK
BORING Providing Bored Cast-in-situ M:30 grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of excess mud with freshly prepared drilling fluid by using pumps prior to placing concrete by tremie pipe in one continuous operation and including the cost of all materials and labour for placing of concrete and also including the cost of mobilization and hire charges of all equipment necessary for boring, welding of reinforcement cage as necessary and lowering of reinforcement cage, preparation and placing of concrete, including the cost of concrete but excluding the cost of reinforcement and labour for bending binding etc. complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Work to be executed as per IS: 2911 (Part II Sec 2) (a) Using hydraulic piling rig iv) Pile diameter - 600 mm. The Rate of providing the temporary steel casing upto 3m depth is included.
(a) Using hydraulic piling rig i) Pile diameter - 750 mm. The Rate of providing the temporary steel casing upto 3m depth is included.
Providing MS casing pipe around RCC cast-in-situ bored piles of different diameters in position including cost of all materials, fabrication, handling etc. complete as per direction of Engineer-in-Charge.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. (c) For 600mm Pile
(d) For 750mm Pile
Performing Lateral load test on two piles or two groups of piles by introducing a hydraulic jack with gauge between two piles or pile groups under test by applying horizontal loads in increments of about 20% of the estimated safe load at each stage and applying the next increment after the rate of displacement is nearer to 0.1 mm. per 30 minutes till the total displacement becomes, 12 mm at the cutoff level including the cost of arranging the entire set-up, hire charges of all implements including at least two dial gauges, preparing the pile head if necessary, and removal of all arrangement after completion etc. complete in all respect including cost of carriage of all materials and as per IS specification and direction of Engineer-in-charge.
Performing Vertical load test on single Pile in accordance with IS:2911(Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete of required strength for receiving the jacks with all ancillary arrangements for setting up gauges, construction of suitable platforms, keeping the loads and dismantling and removing all arrangement etc. complete as per IS specification and direction of Engineer-in-charge. iii) Testing load between 150 T and 200 T. N.B. This item is applicable for both work pile and test pile. Test should be carried out as per IS 2911 part IV 1985.
Integrity testing of Pile using Low Strain / Sonic Integrity Test / Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerized equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-incharge. c) North Zone
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof
STRUCTURAL WORK
Pre-Constructional Anti-termite measures: Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in 7.2.3. of code IS-6313 (part-II) 2013. (Mode of measurment will be plan area of plinth treated.)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Depth of excavation for additional depth beyond 3000 mm. upto 4000mm. excluding cost of shoring as necessary.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
(c) (i) With carried earth arranged by the contractor within a radius of 1 km. including cost of carried earth.
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Supplying and laying Polythene Sheet (150gm / Sqm) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Batch Mixed concrete of M 30 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [Cement to be supplied by Deptt, if Cement is supplied by agency then item rate to be deduced as per Format A of Annexure I] [with Batching Plant & transit mixer] In Ground Floor & Foundation. [Pakur Variety]. The ground floor equivalent height shall be taken as 4 m. Every 4 m or part thereof above 4 m shall be taken as each additional floor (ii) With approved concrete pump. (a) In ground floor
In first floor
In second floor
In third floor
Batch Mixed concrete of M 40 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [Cement to be supplied by Deptt, if Cement is supplied by agency then item rate to be deduced as per Format A of Annexure I] [with Batching Plant & transit mixer] In Ground Floor & Foundation. [Pakur Variety]. The ground floor equivalent height shall be taken as 4 m. Every 4 m or part thereof above 4 m shall be taken as each additional floor (ii) With approved concrete pump. (a) In ground floor
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
Batch Mixed concrete of M 50 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [Cement to be supplied by Deptt, if Cement is supplied by agency then item rate to be deduced as per Format A of Annexure I] [with Batching Plant & transit mixer] In Ground Floor & Foundation. [Pakur Variety]. The ground floor equivalent height shall be taken as 4 m. Every 4 m or part thereof above 4 m shall be taken as each additional floor (ii) With approved concrete pump. (a) In ground floor
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
Batch Mixed concrete of M 60 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [Cement to be supplied by Deptt, if Cement is supplied by agency then item rate to be deduced as per Format A of Annexure I] [with Batching Plant & transit mixer] In Ground Floor & Foundation. [Pakur Variety]. The ground floor equivalent height shall be taken as 4 m. Every 4 m or part thereof above 4 m shall be taken as each additional floor (ii) With approved concrete pump. (a) In ground floor
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
Batch Mixed concrete of M 20 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant under controlled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 320 Kg of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. [Cement to be supplied by Deptt, if Cement is supplied by agency then item rate to be deduced as per Format A of Annexure I] [with Batching Plant & transit mixer] In Ground Floor & Foundation. [Pakur Variety]. The ground floor equivalent height shall be taken as 4 m. Every 4 m or part thereof above 4 m shall be taken as each additional floor (i) With approved concrete pump. In ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In ground floor The ground floor equivalent height shall be taken as 4 m. Every 4 m or part thereof above 4 m shall be taken as each additional floor
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
Extra over main Shuttering Item for shuttering in shell roof, grid roof with vertical faces folded plate, arched roof. In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
(e) Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m)
Supplying and labour charges for shuttering with centering and necessary staging by 6mm thick FRP made decorative board made by Best quality glass matt and GP rasin with 32mm fabricated steel frame and necessary fixing arranegement for curved or straight surface including fitting, fixing and striking out after completion of works as per direction of EIC.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
CRS Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
ARCHITECTURAL WORK
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
In superstructure, ground floor
In first floor
In second floor
In third floor
In fourth floor
In Fifth Floor
In Sixth Floor
In Seventh Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
In first floor
In second floor
Extra for using approved H.B netting in every third layer in 125mm thick brick work above in any floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (a) 20 mm thick plaster In Ground Floor
In first floor
In second floor
(b) 15 mm thick plaster In Ground Floor
In first floor
In second floor
(c) 10 mm thick plaster In Ground Floor
In first floor
In second floor
Labour for Chipping of concrete surface before taking up Plastering work.
[As per analysis] 75 mm thick Ornamental Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. With 1:4 cement mortar
WALL FINISHES WORK
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint Including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats ii) Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) ii) Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats [This item to be done under specific instruction of the Superintending Engineer]
In first floor
In second floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion
In first floor
In second floor
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : Super glosses (b) On steel or other metal surface : (iv) Two coats (with any shade except white)
FALSE CEILING WORK
CALCIUM SILICATE BOARD FALSE CEILING - Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x 0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of CalciumSilicate Board /POP to ceiling section and perimeter channels with thehelp of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering upto 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. CALCIUM SILICATE FALSE CEILING
ORNAMENTED POP MOULDING /MEDALLION -- Providing and fixing of POP 3D ORNAMENTED MOLDING, to be fixed on falseceiling, with all necessary structure ,hardware etc,including labour ,materials and scafolding and surface finished with acrylic paint.Finished with all complete as per the drawing & directions of Engineer-in-charge. a) DIA 3000
Providing and fixing Trap door with following specification including cost of shop drawings, materials, transportations, Labour, consumable etc. all complete a) Trap door having hardwood frame structure of section 75X38 mm wood and 16mm ply to be fixed to the structure and finished with 1mm thick laminate for outer side and 0.8 mm thick laminate for inner side. All exposed edge to be finish with wooden lipping. Rate is considered including of all required hardware.
POP CORNICE/MOULDING -- Providing and fixing of POP cornice continious, to be fixed on falseceiling & wall junction, wall paneling with all necessary structure ,hardware etc,including labour ,materials and scafolding and surface finished with acrylic paint.Finished with all complete as per the drawing & directions of Engineer-in-charge. SIZE - 200X450
SIZE - 450X750
SIZE - 200X300
SIZE - 50x100
SIZE - 50x50
SIZE - 50x25
SIZE - 100x35
SIZE - 25x25
WATER PROOFING
Expansion joint in floor roof etc. formed with V strips made of 22.5 cm wide strips of 24 gauge aluminium sheets with anchor arm projecting on each side (and end turned ) embedded in adjacent cement concrete, including shaping and finishing the edges on either side of the joint (including the cost of bituminous filler if any) complete as per direction of Engineer-in-Charge.
Sealing new expansion joint with Elastomeric Polysulphide Sealant of gap size 50mm X 25mm Including cleaning of the expansion joint thoroughly, mending of Edges & surface, placing 50mm dia Backer rod as back up material with the cost of materials, labours, & all other incidental charges as per manufacturer's specification & direction of Engineer-incharge.
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Polymer concrete made with water resistant bonding agent of synthetic rubber emulsion as per manufacturer's specification excluding the cost of cement concrete (2.75 Kg / bag of cement) Note : Payment on volume of (1 : 1½ : 3) Concrete.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
HDPE(High Density Polyethylene) based homoginious HDPE membrane polyester reinforced and vapor permiable, planet rout resistance HDPE water proofing membrane and dimple board over the membrane at vertical face to protect the membrane for UGR.
FLOOR FINISHING WORK
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] (b) With Chawk Dungri (iv) Area of each slab/tile exceeding 1.00 sq.m (This item to be executed on Specific permission of Superintending Engineer) [Basic Price of Chawk Dungri Marble - Rs. 190.00/Sq.Ft.]
Supplying, fitting and fixing Marble Slab of 20 mm thickness (+/- 1 mm) in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] With Vietnam White Area of each slab exceeding 1.00 sq.m [Basic Price of Vietnam White Marble - Rs. 700.00/Sq.Ft.]
Supplying, fitting, fixing marble slab, 16mm thick (+/- 1mm) in dado / wall on 15 mm thick [avg] cement mortar (1:2) fixed with premium quality highly polymer modified cementition stone adhesive (Kerakoll or equivalent) including making suitable arrangements to hold the stones properly & pointing in cement mortar (1:2) (1 cement, 2 marble dust) with admixture of pigment matching the stone shades including polishing all complete as per direction of the Engineer-in-charge including cost of materials, labours, scaffolding, staging, curing complete. [Pigment to be supplied by the Agency] With Vietnam White Area of each slab exceeding 1.00 sq.m [Basic Price of Vietnam White Marble - Rs. 640.00/Sq.Ft.]
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout & 4mm PVC Spacer materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 N (B) Light Colour
In first floor
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick (i) In superstructure, ground floor
[P-192, IT-15, PWD(Bldg)] Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. The top must be LEATHER FINISH and gap between granite slab mentioned in drawing must be filled with epoxy groute. In ground floor (c) Area of each Granite slab above 1.00 Square meter. [Basic Price of Leather Finish Granite - Rs. 220.00/Sq.Ft.]
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] In ground floor (b) Area of each Granite slab above 1.00 Square meter. [Basic Price of Prepolished Granite - Rs. 200.00/Sq.Ft.]
6mm average thick colour texture pavement (stamp concrete)made with cementitious colour pigment including hardener etc. lade over 100 mm thick M-30 concrete as per pattern by rubber block as directed including curring washing cleaning and two coat sealer over colour texture complete as per manufacturer specification.(The rate are inclusive of M30 RMC)
Supplying fitting and fixing 18 mm thick Marble slab/Tile in "INLAY WORK" over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur Pink / Udaypur green / Black Bhalsana i) INLAY WORKS - 18 mm x 200 mm wide Coloured Marble Inlay
ii) INLAY WORKS - 18 mm x 100 mm wide Coloured Marble Inlay
iii) INLAY WORKS - 18 mm x 50 mm wide Coloured Marble Inlay
Supply, Packing and transporting and fixing of handcrafted items & 250 mm Wide coloured marble patteren Inlay design Cut/assemble of CNC/Waterjet with Vietnam super white or Indian white wherever required as mentioned below complete in all respect including cost of all labour, machineries, materials, brass, adhesive, marble, fixing etc as specified and approved by EIC. Over 18mm thick Vietnam White marble with Pink, Green & Brass INLAY WORKS - 18 mm x 250 mm wide
Supplying fitting and fixing 18 mm thick Marble slab/Tile in "PATTERN MOTIFF INLAY WORK" over 15mm (avg) thick base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/ Sq.m at back side of marble and jointed with white cement slurry @ 2.2 kg/ Sq.m with necessary pigments including grinding and Granite Polishing. [White cement and Pigment to be supplied by the Agency] (a) With Makrana plain pink / Adranga Pink / Garbh Gulabi / Udaypur Pink / Udaypur green / Black Bhalsana 1/ Pattern inlay 325 dia coloured marble Machine cut / CNC cut with bruss combination
3/ Pattern inlay 4100mm dia coloured marble Machine cut / CNC cut
9/ Pattern inlay 600 mm dia coloured marble Machine cut / CNC cut
Providing and fixing Brass Solid section of specified size with necessary brass/steel screws including drilling holes in base / Patti and making good etc. all complete.as per drawing & direction of the EIC Size : Any section as per approved drawing.
WOOD WORK
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (c) Sal : Siliguri. 125 x 65mm thick sal wood door & window frame with all fittings. In ground floor
In first floor
In second floor
In third floor
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf)
In first floor
In second floor
In third floor
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor Glossy/Matt/Suede excluding surface texture or metallic lustre. (ii) Thickness of laminate 1 mm
In first floor
In second floor
In third floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. 40mm X 6mm, 125mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: 100 x 63 x 3.2mm.
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 150mm long x 10mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: 125 mm grip x 10 mm dia rod.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.
Door stopper (Anodised aluminium)
Providing and fixing of double shutter door with following specification including cost of shop drawings, materials, transportations, Labour, consumable etc. all complete. a)Main frame of shutter in both direction will be 75mmx38mmx5mm Aluminium box section. Distance between horizontal members will be less than 660mm or as per approved drawing. Vertical section will be three in each shutter. b) 12mm thick BWP ply to be fixed on both side of the Aluminium frame c) 12 mm thick solid teak wood to be fixed on both side over 12mm ply. d)25mm teak wood relief asper approved design to be fixed on both side over 12mm solid teak wood. e) Shutter to be fixed on metal bush in metal box of approved size and specification. 25mm dia tempered rod to be provided to fix the shutter as per approved drawing. If manufacturer wants to change the fixing arrangement prior approval with justification to be accorded. f) Door frame and architrave - Door frame will be with 80mm x 250mm solid seasoned CP teak wood and the Door Frame Architrave will be with solid seasoned CP teak wood of 80mmx 300mm. Length / height and design of frame / Architrave will be as per approved drawing. g) Door frame to be fixed with RCC with 125mm stainless steel fastener of approved manufacturer. h) Entire surface of frame and shutter will be finished with PU laker finish. i) 2 nos Brass ring Handle of 16 mm rod of 250 mm Dia. j) 4 Nos 1 Mtr long Floor and Ceiling mounted tower bolt. ANTAR MANDAP - 4200 X 6000
SHAKTI - 3050 X 4950
JOTIRLINGA - 1800 X 3000
MUSEUM - 3000 X 5000
Providing and fixing of Single shutter door with following specification including cost of shop drawings, materials, transportations, Labour, consumable etc. all complete. a) Main frame of shutter 30mm thik seasoned CP Teak wood finished with CNC Cutting design. b)25mm teak wood relief as per approved design to be fixed on both side over 12mm solid teak wood. c) Door frame and architrave - Door frame will be with 80mm x 250mm solid seasoned CP teak wood and the Door Frame Architrave will be with solid seasoned CP teak wood of 80mmx 300mm. Length / height and design of frame / Architrave will be as per approved drawing. d) Door frame to be fixed with RCC with 125mm stainless steel fastener of approved manufacturer. e) Entire surface of frame and shutter will be finished with PU laker finish. f) Brass Hasp Bolt at each door. g) Brass Tower bolt at inside. ANTAR MANDAP STORE - 1200 X 2450
SHAKTI STORE - 900 X 2450
Providing and fixing of Main Vedi Singhason inside the Main Mandir, complete in all respects as per approved drawings and details. The Singhason shall be fabricated using 1st class teakwood with CNC/machine-cut carving works fixed over 19mm thick plywood on MS structural framework. a) Singhason shall be designed with four posts, with the total carved design fixed above the posts as per architectural drawings. b) MS structure for four posts shall be fabricated using 150x75x5 mm rectangular MS sections. c) Plywood framework shall be fixed over the MS structure as per approved design. d) Flexi ply shall be fixed in curved/required profiles to achieve the desired shape. e) Teakwood decorative beading and moulding shall be fixed in position over the ply surfaces. f) Back side of the Singhason shall be finished with teakwood carving work paneling, as per design. g) Red raw silk fabric with ornamented stitching work and required frills shall be provided and fixed at the designated locations as per drawing and design intent.(Fabric - 6000 Sq.ft included) h) The entire exposed surface of posts and Singhason shall be finished with matte lacquered polish to achieve a smooth and uniform finish. The work shall be executed in a neat, workmanship-like manner and completed in all respects as per drawings, specifications, and instructions of the Architect/Engineer-in-Charge.
ALUMINIUM WORK
Aluminum Sliding Windows:- Supply ,fabrication and installation of DOMAL or Equivalent series 3 Track Sliding windows duly powder coated as per approved shade, with locking system along with fixing of 8 mm thk. Toughened glass. The entire system shall be mounted on S.S make friction stray windows. The cost is inclusive of all materials, labour, silicon, gusket, screw, lock, roller, fitting and fixing as per direction of EIC.
Designing, supplying, fabricating and erecting of suitable frame less structural glazing works as per drawing with out frame fixed on wall with side patch and as per approved manufacturer's specification, including colour anodising and fixing of toughened Laminated glass of Size 13.52(6+1.52 PVB+6) mm th. glass complete in all respects as per direction of Architect/E.I.C. at any level.
ROLLING SHUTTER WORK
(b) Supplying fitting and fixing steel rolling grills link type, shutter with 18 B.G .of approved type steel to the section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
MS WORK
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
M.S. gate works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.
Providing and Painting of structural steel surfaces of bridge members by grit blast cleaning or centrifugal blasting with a suitable abrasive materials like crushed slag in accordance with clause-III of IS 6586 : 1989 immediately before painting , to make the surface free from grease, oil, rust and other foreign materials. The rate includes supply of abrasivesand,fuel, cost of paint including all transportation, lead, lift and labour charges, consumables, tools & plants complete in all respect but exclusive of cost for staging/scaffolding. Painting of approved Zinc-phosphate primer of DFT 65 micron followed by finish coat of Micaceous iron oxide pigmented drying oil type paint of DFT 75 micron.
OTHERS WORK
Solid granite Shiv Ling (special granite imported from Nepal, 7 m height, large scale) – Supply, quarrying, transport from Nepal, rough shaping, detailed carving, polishing, and finishing; including anchoring/embedding on RCC plinth, stainless steel fasteners, scaffolding, handling, and installation as per approved design. Includes all decorative carvings, inscriptions, and smooth surface finishing. Shiv Lingam made of Shaligram / Nepal special stone /Granite
Providing, carving / supplying and fixing Jyotirlinga / Shiv ling as per approved drawings, black granite stone; size as per design (height approx. 1.5 as per architect); includes all polished finish, engravings, inscriptions, and motifs as per require. fixed on RCC plinth as per design; includes all scaffolding, transport, handling, alignment, polishing, and finishing etc.
Providing, carving / supplying and fixing granite stone murti as per approved architectural drawings, high-quality natural granite, hand-carved or machine-finished; size as per design (height and proportions as per drawings); includes all decorative features, motifs, engravings, inscriptions, and polished / machine-finished surface; fixed securely on RCC plinth / base with dowels / adhesive as per design; includes all scaffolding, transport, handling, alignment, polishing, and finishing to provide a complete granite murti ready including installation , all completed. Murti : Vishnu , Ganesh , Kartik & Shakti
Providing, fabricating, and fixing Metal Crown, 8mm thick Ashtadhatu Plate wrapping over the specified member/structure made from stainless steel (as specified), cut, bent, and formed to the required profile and shape, including necessary welding, grinding, edge finishing, and polishing. The crown shall be securely fixed with anchor fasteners / brackets / welding as required, ensuring proper alignment and stability. The work shall include all materials, labour, scaffolding, transportation, tools & tackles, protective coating, and making good of all adjoining surfaces, complete as per drawing, specification, and direction of Engineer-in-Charge. all completed. Vishnu, Ganesh, Kartik, Shakti & Antar Mandap
Nandi
SHIV MURTI
Structural Stainless Steel work built up sections Providing, supply, fabrication, transportation and erection of complete internal structural framework in Stainless Steel 304 grade built-up sections exclusively for construction of 33.00 metre high Shiv Statue with four hands. The work comprises columns, space frame members, trusses, rafters, floor joists, wind bracings, tie beams, gusset plates, base plates, anchor bolts, stainless steel fasteners and all necessary connection elements required for stability, strength and to achieve the desired statue geometry, complete in all respects as per approved structural design, detailed drawings and directions of the Engineer-in-Charge. These structural stainless steel built-up sections shall be manufactured using advanced CNC Plasma / Oxy-Acetylene cutting equipment and H-Beam Welding line. Welding shall be carried out in full depth on both sides of plates/sections adopting relevant Indian Standard Codes for stainless steel welding and fabrication. The item includes all operations such as cutting, grinding, drilling, bending, machining, shop assembly, trial fit-up, transportation to site, lifting, alignment, leveling, bolting, site welding, scaffolding/staging required for erection at 33 m height, safety arrangements, tools and tackles, cranes and skilled manpower, all complete.
Bronze metal CASTING cladding Design, supply, fabrication, taransportion and erection of bronze metal 8 mm thick casting cladding over existing structural stainless steel built-up sections . These sheet cladding shall be manufactured using advanced CNC Plasma/Oxy Acetylene cutter and H Beam Welding line. Welding shall be in full depth on both sides of the plate adopting relevant I.S Code and as per manufacturer specifications and direction of Enginner in charge ,complete with all respect as desired as site. The rate are inclusive of all material, transportation upto site, fabrication, installation and required any tools or machineries and any lifting arrangement during installation.
STONE WORK WITH CURVING WORK
The BANSHI PAHARPUR / MASALPUR / DHOLPUR Sand stone shall be as specified in the description of item. The stone shall be hard, sound, tough, free from cracks, decay & weathering. In case of red sand stone, white patches or streaks shall not be allowed. However scattered spots upto 10 mm diameter will be permitted. Before starting the work the contractor should submitt the SHOP drawing and Sample Stone, now after getting the approval of Shop drawing from EIC and after getting approval of SAMPLE STONE from the Engineer-in-Charge contractor only can start the stone work. i) Size of Stone : Normally stones used should be enough to be lifted and placed by crane or lifter. The length, breadth and height of the stone shall be as per approved SHOP drawing. ii) Dressing : Every stone shall be cut to the required size and shape chisel dressed on all beds and joints so as to be free from waviness and to give truly vertical and horizontal joints. In exposed masonry, the faces that are to remain exposed in the final position and the adjoining faces to a depth of 6 mm shall be the fine chisel dressed so that when checked with 60 cm straight edge, no point varies from it by more than 1 mm. The top and bottom faces that are to form the bed joints shall be chisel dressed so that variation from 60 cm straight edge at no point exceeds 3 mm. Faces which are to form the vertical joints should be chisel dressed so that variation at any point with 60 cm straight edge does not exceed 6 mm. Any vertical face that is to come against backing of masonry shall be dressed such that variation from straight edge does not exceed 10 mm. All angles and edges that are to remain exposed in the final position shall be true, square and free from chippings. A sample of dressed stone shall be prepared for approval of Engineer-in-Charge/Architect/Consultant. It shall be kept at the worksite as a sample after being approved.
iii) Carving : Labour for integrated and ornamental carving/curving works over Banshi Paharpur Sand Stone at any level in-situ for entire Project. Stone Curving work of any diameter and of any design as per approved shop drawing should be done and shall include all cutting and waste and templates. The entire curving work will be done as per approved shop drawing at ground level before fixing or at any level after fixing. The work includes labour charges, all machineries, tools and tackles, lifting arrangment, consumables, grinding wheel required for curving etc. Including the cost for Hydra or any crane for turning, shifting, holding to facilitate the carving work and including cost of all infrastrcuture works to accomodate the skilled gang etc all complete. The work shall be carried out by high skilled well experienced labours and to be executed manually or by engagnig machineries tools and tackles. The work will be executed as per direction of EIC.
iv) Laying : All stones shall be wetted before placing in position. These shall be floated on mortar and bedded properly in position with wooden mallets without the use of chips or under pinning of any sort. interconnect between two adjacent stone properly SS-304 'C' Clamp at any height and level need to be provide. The clamp having total length minimum (3"+12"+3"=)18" and 12mm dia. The 3" side of Clamp should penitrate in cutting hole in Stones. The rate is inclusive of all materials, labours and all others machineries to create holes, groove and anchored etc. The work will be executed as per direction of EIC. The walls and pillars shall be carried up truly plumb or battered as shown in drawings. All courses shall be laid truly horizontal and all vertical joints shall be truly vertical. When necessary, jib crane or other mechanical appliances shall be used to hoist the heavy pieces of stones and place these into correct positions, care being taken that the corners of the stone are not damaged. Stone shall be covered with gunny bags, before tying chain or rope is passed over it, and it shall be handled carefully. No piece shall be used in work which has been damaged. After placing the stone the Stone joint should be filled with mixture of White cement and Pigment to match the Stone colour and the gap between stone and RCC or Stone with stone filled with Sand Cement (1:1) Mortar.
Supplying, fitting and fixing of SS 304 Clamp at any height and level to hold the Stone with RCC Wall. The clamp having 3 side of total length (8"+8"+3"=)19", 4" width and 8mm thick. It is almost looks like a Z. The 2 sides having length 8" and 3" are perpendicularly connected with straight middle side having length 8" and in opposite direction. The 8" side of Clamp should anchored with RCC surface by 2 nos M12x115 Mechanical anchor and the other 3" side will penitrate in cutting groove in Stone. The rate is inclusive of all materials, labours and all others machineries to create holes, groove and anchored etc. The work will be executed as per direction of EIC. The Mechanical anchor Bolt must be HILTI OR EQUIVALENT make. Clamp Size - 19"X4"X8mm
[As per analysis] Labour charges for intricately carving of two dimensional Murti or sculptures or any kind of figure over existing sandstone of all structure at any levels. The entire curving work will be done as per approved shop drawing. The work includes labour charges, all machineries, tools and tackles, scaffolding, consumables, grinding wheel required for curving etc. Including the cost for Hydra or any crane if necessary to facilitate the carving work and including cost of all infrastrcuture works to accomodate the skilled gang etc all complete. The work shall be carried out by high skilled well experienced labours and to be executed manually or by engagnig machineries tools and tackles. The work will be executed as per direction of EIC. SIZE - ANY. [The exact height of the carved murti will be considered as final measurement. The height of the plane on which the murti will be carved will not be considered]
[As per analysis] Labour charges for intricately carving of three dimensional Murti or sculptures or any kind of figure for all structure at any levels. The entire curving work will be done as per approved shop drawing. The work includes labour charges, all machineries, tools and tackles, scaffolding, consumables, grinding wheel required for curving etc. Including the cost for Hydra or any crane if necessary to facilitate the carving work and including cost of all infrastrcuture works to accomodate the skilled gang etc all complete. The work shall be carried out by high skilled well experienced labours and to be executed manually or by engagnig machineries tools and tackles. The work will be executed as per direction of EIC. [The exact length of the carved murti will be considered as final measurement.]
Granite cladding for Surya Stambh (21 m height × 1.5 m dia) and Dhunuchi Stand (2 m x 2 m x 1.35 m height) including decorative motifs / carvings – Supply, cutting, shaping, and machine-polished granite slabs fixed over RCC column and plinth/base; including stainless steel anchors / fasteners, adhesive / cement bedding, pointing, alignment, and finishing as per approved drawings. Surface to be smooth and polished, curved as per column, and motifs aligned properly.
FURNITURE AND BOUGHT OUT ITEMS
Supplying single Bed Wooden Cot (Size 3’6” X 7’0”) and Installation in proper position with required section and as per approved design, made of with Best Indian Teak wood and 19mm ply (IS: 303) Finished with 1.5mm laminated board on one side for resting the mattress used as Chali. The cot finished with Hi-quality polyurethane polish with required colour as approved. The work is inclusive of all material, labour, transportation, hire charges of machinery and all incidental charges complete as per direction of Engineer – in – charge.
Mattress, Pillow, Bed Sheet and Bed Cover For Single Bed supply of 4" thick Sleepwell / Duroflex / Kurlon make Ortho Mattress, High Density Resitec Foam, Medium Firm, Memory Foam, Breathable Fabric including One(1) Pillow with white Cover and one(1) number white Bed sheet and Bed cover.
Supplying Double Bed Wooden Cot (Size 6’0” X 7’0”) and Installation in proper position with required section and as per approved design, made of with Best Indian Teak wood and 19mm ply (IS: 303) Finished with 1.5mm laminated board on one side for resting the mattress used as Chali. The cot finished with Hi-quality polyurethane polish with required colour as approved. The work is inclusive of all material, labour, transportation, hire charges of machinery and all incidental charges complete as per direction of Engineer – in – charge.
Mattress, Pillow, Bed Sheet and Bed Cover For Double Bed supply of 4" thick Sleepwell / Duroflex / Kurlon make Ortho Mattress, High Density Resitec Foam, Medium Firm, Memory Foam, Breathable Fabric including two(2) Pillow with white cover and one(1) number Double white Bed sheet and Bed cover.
Supplying WARDROBE (Size 4’0” x 7’0” x 18”) and Installation in proper position With required section and as per approved design, made of with Best Indian Teak wood and the Wardrobe having 2Nos. shelf full, 2Nos. shelf half and vertical divider upto 4” from top and 1No. drawer. The Wardrobe finished with Hi-quality polyurethane polish with required colour as approved. The work is inclusive of all material, labour, transportation, hire charges of machinery and all incidental charges complete as per direction of Engineer – in – charge.
Supplying Study Table ( Size 3’0” x 2’0” x 2’6”) and Installation in proper position with required section and as per approved design, made of with Best Indian Teak wood and the table having foot rest, 4” above from bottom level the Table finished with Hi-quality polyurethane polish with required colour as approved. The work is inclusive of all material, labour, transportation, hire charges of machinery and all incidental charges complete as per direction of Engineer – in – charge.
Supplying and febrication of wooden chair of standard size as per direction of EIC.
Supplying three seater sofa (Size 6’0” x 2’6”) and Installation in proper position with required section and as per approved design, made of with Best Indian Teak wood and the Sofa finished with Hi-quality polyurethane polish with required colour as approved. The work is inclusive of all material, labour, transportation, hire charges of machinery and all incidental charges complete as per direction of Engineer – in – charge.
Supplying Centre Table ( Size 3’0” x 1’4”) and Installation in proper position with required section and as per approved design, made of with Best Indian Teak wood and the Table finished with Hi-quality polyurethane polish with required colour as approved. The work is inclusive of all material, labour, transportation, hire charges of machinery and all incidental charges complete as per direction of Engineer – in – charge.
Supply and installation of Supreme make chairs Ornate or equivalent, Lacquered Finish Plastic Desk Armchair with Cushion for Office, Weight Bearing - 200 kg, Color will be Red and Black and Dimensions of the product will be 560 X 560 X 815 as per instruction of EIC. The rate is inclusive of transportation, installation at any floor and all others required material and tools.
Supply and installation of Adjustable Set of 7-shelf Metal Shelving Unit Storage Utility Rack, having dimension of 5'(L) X 6'(H) X 18"(W) including all necessary material and tools for installation as per direction of EIC.
Supply and installation of MS Single Bed made by premium quality steel which is Cold rolled corrosion resistance steel assuring a long self life. Additionally, 2mm thick powder coating on top to avoid any corrosion which also adds a premium touch. Having dimension of 4' X 7' including mattress, Pillow and Bed cover of 1 set as per direction of EIC.
Supplying, installing, testing, and commissioning stationary electric scissor lift platform fixed on floor for achieving 8–10 m working height, including manufacture-approved scissor lift unit, base frame, guide mechanism, electric motor, hydraulic system, control panel, safety rails, emergency stop, limit switches, and overload protection; complete with anchoring/bolting to RCC floor, leveling, alignment, electrical connections, trial run, and commissioning; including all materials, labour, tools, handling, and accessories, executed as per vendor specifications and applicable safety standards.
20 passenger automatic lift having following specification : a) Gearless MRL (Machine Room Less) b) no of stop-4 to approx, Two Opening c) Building height 23 mtr. Travel distance 23mtr (approx) d) Speed should be consider 0.63mte/sec. e) Coated steel belt as a traction media. f) All lift car and door will be stainless steel finish. g) ARD (Automatic Rescue Device Required) h) No fire mans drive required. i) Make of lift : OTIS/Kone elevator/Mitshubishi/Schindler. j) Lift door will be ACVF with 1200 mm opening. k) Intercom l) Well size 1800 wide X 2000mm (finish) m) Battery operated emergency alarm & light.
5 passenger automatic lift having following specification : a) Gearless MRL (Machine Room Less) b) no of stop-2, Two Opening c) Building height 9.5mtr. Travel distance 4mtr (approx) d) Speed should be consider 0.63mte/sec. e) Coated steel belt as a traction media. f) All lift car and door will be stainless steel finish. g) ARD (Automatic Rescue Device Required) h) No fire mans drive required. i) Make of lift : OTIS/Kone elevator/Mitshubishi/Schindler. j) Lift door will be ACVF with 750mm opening. k) Intercom l) Well size 1650 wide X 1500mm deep (finish) m) Battery operated emergency alarm & light. Make - Kone / Schindler / Otis
SANITARY AND PLUMBING
SECTION (A) - PLUMBING WORKS (A)-(III) CPVC PIPE WORKS AND FITTINGS Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 15 mm
(b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 15 mm
SECTION (A) - PLUMBING WORKS GI PIPE WORKS AND FITTINGS C.I. sluice valve with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gunmetal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete. (i) 50 mm
(iii) 100 mm
Sluice valve chamber with C.I. heavy cover with locking arrangement,(weight not less than 25 kg) (size of chamber 450 mm X 600 mm inside upto 900 mm depth) 250 mm thick cement brick walls (6:1), 150 mm thick cement concrete (6:3:1) bed with stone chips, 20 mm thick cement plaster (6:1) for inside wall and 15 mm thick cement plaster (4:1) for outer walls including rounding corners.
SECTION (A) - PLUMBING WORKS GI PIPE WORKS AND FITTINGS Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes 15 mm
Supplying, fitting and fixing Wall Mounted water closet of white glazed vitreous china ware of approved make & brand in position complete with necessary bolts, nuts (Equvalent to Code No. 20061 or 92065 & Model Stidio or Rubbic of Hindware or equivalent).
Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete. a)(iv) Bestolite (solid type) white
Supplying, fitting & fixing EWC (Size 710x370x810mm)in white glazed vitreous china ware of approved make supplying , fitting and fixing in position complete with necessaryt nut & bolt.( Model Code No. S10221114 P Trap( CRUSE SET) of CERA or equivalent
Supplying, fitting & fixing 10 litre white glazed vitreous chinaware of approved low down cistern of approved make with either side or bottom inlet,side overflow,brackets complete with all inernal fittings (Model Code No: S1060106 of CERA or equivalent). White
Supplying, fitting and fixing 15mm twin flash fitting ( Model Code No. B1810112 of CERA or equivalent)
Soft close seat cover of approved make with lid and C.P hinges, rubber buffer and brass screws supplying and fixing complete.EWC( Model Code No B1520118 of Cera or equivalent). White
f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand).
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. ii) C. P. Flush Pipe
Providing and fixing concealed cistern of size 380 mm long, 400 mm wide, 100 mm thick alongwith flush plate and flush pipe with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality with all fittings and fixtures complete, including cutting and making good the walls wherever required. (Model: Cento of Hindware or similar brand.) [Note: This work should not be executed without specific permission of Superintending Engineer.]
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting & fixing chrome plated brass battery based infrared sensor oprated pillar cock , having foam flow technology. (Model: Pillar Sensor Faucet of Hindware or similar brand). [Note:This work should not be executed without specific permission of Superintending Engineer.] 15 mm normal bore
Supplying, fitting and fixing pillar cock of approved make. c) CP Pillar Cock - 15 mm. (Code No. 5011 & Model - FLORENTINE of JAQUAR or equivalent).
Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) (a) Chromium plated Bottle trap 32 mm with 190 mm long connecting pipe and wall flange (Equivalent to Code No. 545 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model -Florentine of Jaquar or similar brand).
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long
Supplying, fitting and fixing towel rail with two brackets. CP over brass 25 mm dia. and 600 mm long
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect.
Supplying, fitting & fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610x390x370 mm having pre & post flushing with water (250 ml & 350 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-Charge. (Model: Senso Art of Hindware or similar brand.) [Note: This work should not be executed without specific permission of Superintending Engineer.]
Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one
Provideing & fixing PTMT 15mm. Urinal spreader size 95x65x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 grams.
Supplying, fitting and fixing liquid soap container. (c) Fibre glass
Supplying, fitting and fixing soap holder. (b) Fibre glass
Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary. (i) Roll type size 250 mm X 125 mm
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm
(g) CP Sink Cock with Regular Swinging Spout (Table Mounted Model) (Equivalent to Code No. 5357 of JAQUAR or similar brand).
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iii) 600 mm long
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iv) 1050 mm long
Providing and fixing PTMT Bottle Trap for Wash basin & Sink Bottle Trap 38mm single piece moduled with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 25 . Breadth with 25 mm minimum water seal, weighing not less than 263 grams.
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing shower of approved brand and make (b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
(c) Chromium plated Hand shower 70mm dia Round Shape Single flow with Flexible Tube & fittings(Equivalent to Code No. ESH-5512 & Model -Tropical / Sumthing Special of ESSCO or similar).
(d) Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).).
(e) Chromium plated double coat Hook(Equivalent to Code No. 35761 & Model - KUBIX of Jaquar or similar).
(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing of Chromium plated Turn type single lever concealed Diverter with lever, tip ton knob and flange of approved brand and make. (h) (i) Exposed Part:- (Model Code No.F2004703 of CERA or equivalent)
(h) (ii) Concealed Part:- (Model Code No. F4010105 of CERA or equivalent)
AMBULANT DISABLED TOILET Fittings of Ambulant Disabled Toilet Supplying, fitting and fixing Stainless steel Wall Mounted Grab Bar. Load bearing capacity 150 kg, covered by Nylon surface with contour finish (for better grip) with Anti-bacterial surface complete. (Model Code No. B2210106 of CERA or equivalent.). 600 mm. long
Supplying, fitting and fixing Stainless steel Wall Mounted Hinged hand rail (750X100 mm) covered by Nylon surface with contour finish (for better grip) with two brackets.(Model Code No.B2210108 of CERA or equivalent.) 750 mm. long.
Providing and fixing brass bib cock approved quality 15 mm. nominal bore
WATER SUPPLY BRASS FITTING
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore.
40 mm nominal bore.
50 mm nominal bore.
65 mm nominal bore.
80 mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore.
20 mm nominal bore.
25 mm nominal bore.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore. Vertical
80 mm nominal bore. Vertical
Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm. dia.
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm. dia.
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 : 80 mm. dia.
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for nonpressure underground Drainage, Sewerage & Cross drainage application. 150 mm. internal dia.
200 mm internal dia
250 mm internal dia
300 mm internal dia
400 mm internal dia
500 mm internal dia
600 mm internal dia
SECTION (B) - SANITARY AND DRAINAGE WORKS (B)-(II) SOIL PIPE AND FITTINGS
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (i) Single Socketed 3 Meter Length ( a ) 75 mm.
(B) Fittings (i) Coupler (a) 75 mm
(ii) Plain Tee (a) 75 mm
(iii) Door Tee (a) 75 mm
(v) Plain Y (a) 75 mm
vii) Double Y (a) 75 mm
viii) Double Y with Door (a) 75 mm
(ix) Bend 45º (a) 75 mm
(x) Bend 87.5º (a) 75 mm
xv) Vent Cowl (a) 75 mm
xvi) Pipe Clip (a) 75 mm
(xvii) W.C. Connector (150 mm long) 125 X 110(W/WC Ring)
(xxxiv) Multi Floor Trap without Top tile & Strainer 75 mm.
JALI CISTERN, G.I. TANKS WITH PARTS
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating.
Supply fitting fixing of 125mm dia CP grating
Constructing Inspection pit to a depth of 1.5metre (inside), 250mm thick 1st class brick work (1:4) in all sides over a layer of jhama bricks oling and 150mm thick cement concrete with stone chips(1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete(1:1.5:3)withstone chips,plastering inside and outside(outsideupto300 mmbelowG.L.)with 20mm thick cement plastering(1:4)and neat cement punning, including supplying,fittingand fixingone 560mm. diaR.C.C. manhole cover of approved make with R.C.C.slabof 100mm thick with cement concrete(1:1.5:3)with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that theR.C.C. cover slabrests150mm above adjucent G.L.,cement plaster(1:4)10mm thick on all external surfaces of the topslabas directed complete inall respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (i)900mmX750mm(inside)chamber including fitting and fixing S.W .master trap of 150 mm dia. of approved make A) With Pakur variety. (SAIL/TATA/RINL
1050mm X 750mm (inside) chambe rincluding fitting and fixing S.W.master trap of 300 mm dia. of approved make A) With Pakur variety. (SAIL/TATA/RINL)
HYDROPNEUMTIC SYSTEM FOR Domestic water Type: Vertical Inline type direct coupled diffuser type centrifugal pump. No. Outlets: Single Outlet, Casing: Material of Construction, CI, Impellers: Material of construction: SS Shaft: High tensile 410 AISI Stainless Steel shaft, Type Bearing: Ball bearing Life Lubricated Pump RPM : 2900 RPM, Motor RPM : 2900 RPM Type of Motor : 3 Phase Squirrel cage Induction TEFC Motor . Motor Insulation: High grade PVC suit ambient Temperature.(0 to 35 Deg.C) No. of Poles: 2 Nos. Supply Voltage : 415 + 10% Cycles/Sec. : 50 Hz + 5% Accessories: Foundation bolts, vibration isolators, base plate, 50mm dia. piping with 50mm dia. non return valve, 50mm dia.butterfly valve up to tank top slab with a common header of 50mm dia. with flanged outlet for connection by client Pressure gauges, switches Mounting Frame (HYDROPNEUMTIC SYSTEM Domestic water Type: Vertical Inline type direct coupled diffuser type centrifugal pump. No. Outlets: Single Outlet Casing: Material of Construction, CI Impellers: Material of construction: SS Shaft: High tensile 410 AISI Stainless Steel shaft Type Bearing: Ball bearing Life Lubricated Pump RPM : 2900 RPM Motor RPM : 2900 RPM Type of Motor : 3 Phase Squirrel cage Induction TEFC Motor . Motor Insulation: High grade PVC suit ambient Temperature.(0 to 35 Deg.C) No. of Poles: 2 Nos. Supply Voltage : 415 + 10% Cycles/Sec. : 50 Hz + 5% Accessories: Foundation bolts, vibration isolators, base plate, 50mm dia. piping with 50mm dia. non return valve, 50mm dia.butterfly valve up to tank top slab with a common header of 50mm dia. with flanged outlet for connection by client Pressure gauges, switches Mounting Frame Pump Duty Condition: . 200 LPM at 35 Mt head. Approximate H.P. = 3.0 - 3 Nos. (2 Working + 1 Standby) (All the Pumps shall be on VFD) DIAPHRAGM VESSEL Supplying, installation testing & commissioning of vertically mounted MS/FRP/MS Epoxy coated fabricated diaphragm type pressure vessel 500 litres capacity spherical with dished ends at top & bottom with supports for test Pressure gauge of 10 Kg./sq.cm with high quality water resistant rubber diaphragm with branches for inlet/outlet & drain connection, Pressure Switch, pressure gauges, connections complete with Air filling foot pump. There shall be complete separation between water and air and there should be no contact between water and tank compounds to avoid corrosion. Bladders shall be suitable for sufficient elasticity to permit full expansion inside the tank to ensure better performance and longer working life. CONTROL PANEL MAIN CONTROL PANEL FOR HYDROPNEUMATIC SYSTEMS SPECIFIC REQUIREMENTS MCC Motor control centres shall be of tailor-made design, wall/floor-mounted type manufactured in factory/shop. Enclosure shall be fixed type (modular draw-out design), dust-tight and vermin-proof having IP54 degree of protection. Main bus for phase and neutral shall be of uniform size insulated electrolytic copper. Separate insulated copper earth bus within the board shall be Provided with a link between neutral and earth bus. Board shall be provided with tow distinct and separate earth terminals on opposite side to connect external earth conductor. All accessible live terminals/ portion of components shall be provided with shrouds. Board shall be of sheet steel enclosed free-standing self- supporting indoor type having front and rear doors. Minimum 2.5mm thick cold rolled (CR) sheet steel shall be used for load bearing members and 1.6mm thick CR sheet shall be used for doors and covers. Board shall be provided with 75mm high base channel, with holes drilled for grouting to foundation. Maximum height of panel, including the height of base channel shall be 2450mm. Minimum and maximum operating heights shall be 300mm and 1800mm respectively. Each feeder compartment shall have a separate hinged door with rolled edges with concealed hinges and thumb grip type screws without any sharp corners to doors. Suitably sized thick non-deteriorating, continuous, neoprene sponge rubber gaskets shall be provided all round the perimeter of adjacent cubicles, between cubicles and base frame. Cutouts on front door for mounting lamps, meters, control switches, handle, etc with inscription plate for component shall be provided. Undrilled gland plate of 3mm thick shall be provided on rear TOP of board. Cable termination chamber shall be at the rear of the board Incoming and outgoing connections from switching devices shall be brought to the cable chamber in a staggered manner for cable terminations. These connections shall be supported on DMC/epoxy insulators such that external cables are not required to be connected directly to the terminals of switching devices. Detachable barriers of perforated metal sheet or minimum 4mm thick non-hygroscopic hylam sheet shall be provided to prevent accidental contact with any live parts. Board shall be spray painted after rust removal, cleaning, rinsing, pickling in acid and phosphatising treatment on sheet steel with two coats of zinc rich primer and two coats of epoxy paint of approved shade. Non rusting metallic or PVC engraved label with proper designation shall be fixed on the front cover of each compartment, in addition to the name-plate for entire MCC. The weight and overall dimensions (LxDxH) MUST be furnished along with the offer with the details of shipping sections, if any. Scope of these TWO MCCS Shall comply with all above Requirements. The Contractor shall provide additional spare Contact in his Panel/Starter for Alarm indicating & connection for Building Automation System The Contact shall be Voltage free as required Tenderer shall provide any all suitable cables as required from respective Panels to Pump for complete working of the System at no additional cost. Cables shall be copper conductor PVCA 1.1 KV grade . Fabricating, Supplying and installing in position sheet steel wall/clad floor mounting cubical pattern front opening type control panel all as per specifications Probe level controllers shall be provided including necessary cabling from tanks to pumps wherever necessary at no extra cost. Vendor shall submit shop drawings for electrical panel and wiring diagram for approval. CONTROL PANEL FOR HYDROPNEUMATIC SYSTEM Pump : 3.0 H.P. (2+1 ) Supply installation testing comissioning of above pump set with all accessories, vessel and control panel
HYDROPNEUMTIC SYSTEM for Flushing water Type: Vertical Inline type direct coupled diffuser type centrifugal pump. No. Outlets: Single Outlet Casing: Material of Construction, CI Impellers: Material of construction: SS Shaft: High tensile 410 AISI Stainless Steel shaft Type Bearing: Ball bearing Life Lubricated Pump RPM : 2900 RPM Motor RPM : 2900 RPM Type of Motor : 3 Phase Squirrel cage Induction TEFC Motor . Motor Insulation: High grade PVC suit ambient Temperature.(0 to 35 Deg.C) No. of Poles: 2 Nos. Supply Voltage : 415 + 10% Cycles/Sec. : 50 Hz + 5% Accessories: Foundation bolts, vibration isolators, base plate, 50mm dia. piping with 50mm dia. non return valve, 50mm dia.butterfly valve up to tank top slab with a common header of 50mm dia. with flanged outlet for connection by client Pressure gauges, switches Mounting Frame Pump Duty Condition: . 150 LPM at 35 Mt head. Approximate H.P. = 3.0 - 3 Nos. (2 Working + 1 Standby) (All the Pumps shall be on VFD) DIAPHRAGM VESSEL Supplying, installation testing & commissioning of vertically mounted MS/FRP/MS Epoxy coated fabricated diaphragm type pressure vessel 500 litres capacity spherical with dished ends at top & bottom with supports for test Pressure gauge of 10 Kg./sq.cm with high quality water resistant rubber diaphragm with branches for inlet/outlet & drain connection, Pressure Switch, pressure gauges, connections complete with Air filling foot pump. There shall be complete separation between water and air and there should be no contact between water and tank compounds to avoid corrosion. Bladders shall be suitable for sufficient elasticity to permit full expansion inside the tank to ensure better performance and longer working life. CONTROL PANEL MAIN CONTROL PANEL FOR HYDROPNEUMATIC SYSTEMS SPECIFIC REQUIREMENTS MCC Motor control centres shall be of tailor-made design, wall/floor-mounted type manufactured in factory/shop. Enclosure shall be fixed type (modular draw-out design), dust-tight and vermin-proof having IP54 degree of protection. Main bus for phase and neutral shall be of uniform size insulated electrolytic copper. Separate insulated copper earth bus within the board shall be Provided with a link between neutral and earth bus. Board shall be provided with tow distinct and separate earth terminals on opposite side to connect external earth conductor. All accessible live terminals/ portion of components shall be provided with shrouds. Board shall be of sheet steel enclosed free-standing self- supporting indoor type having front and rear doors. Minimum 2.5mm thick cold rolled (CR) sheet steel shall be used for load bearing members and 1.6mm thick CR sheet shall be used for doors and covers. Board shall be provided with 75mm high base channel, with holes drilled for grouting to foundation. Maximum height of panel, including the height of base channel shall be 2450mm. Minimum and maximum operating heights shall be 300mm and 1800mm respectively. Each feeder compartment shall have a separate hinged door with rolled edges with concealed hinges and thumb grip type screws without any sharp corners to doors. Suitably sized thick non-deteriorating, continuous, neoprene sponge rubber gaskets shall be provided all round the perimeter of adjacent cubicles, between cubicles and base frame. Cutouts on front door for mounting lamps, meters, control switches, handle, etc with inscription plate for component shall be provided. Undrilled gland plate of 3mm thick shall be provided on rear TOP of board. Cable termination chamber shall be at the rear of the board Incoming and outgoing connections from switching devices shall be brought to the cable chamber in a staggered manner for cable terminations. These connections shall be supported on DMC/epoxy insulators such that external cables are not required to be connected directly to the terminals of switching devices. Detachable barriers of perforated metal sheet or minimum 4mm thick non-hygroscopic hylam sheet shall be provided to prevent accidental contact with any live parts. Board shall be spray painted after rust removal, cleaning, rinsing, pickling in acid and phosphatising treatment on sheet steel with two coats of zinc rich primer and two coats of epoxy paint of approved shade. Non rusting metallic or PVC engraved label with proper designation shall be fixed on the front cover of each compartment, in addition to the name-plate for entire MCC. The weight and overall dimensions (LxDxH) MUST be furnished along with the offer with the details of shipping sections, if any. Scope of these TWO MCCS Shall comply with all above Requirements. The Contractor shall provide additional spare Contact in his Panel/Starter for Alarm indicating & connection for Building Automation System The Contact shall be Voltage free as required Tenderer shall provide any all suitable cables as required from respective Panels to Pump for complete working of the System at no additional cost. Cables shall be copper conductor PVCA 1.1 KV grade . Fabricating, Supplying and installing in position sheet steel wall/clad floor mounting cubical pattern front opening type control panel all as per specifications Probe level controllers shall be provided including necessary cabling from tanks to pumps wherever necessary at no extra cost. Vendor shall submit shop drawings for electrical panel and wiring diagram for approval. CONTROL PANEL FOR HYDROPNEUMATIC SYSTEM Pump : 3.0 H.P. (2+1 ) Supply installation testing comissioning of above pump set with all accessories, vessel and control panel
Supply, installation, testing & comissioning of Grease Separator EasyClean Mix Pump M+S Manufactured according to DIN EN 1825 and DIN 4040, with manually controlled disposal and cleaning, no metallic components in chamber. For free standing installation in frost free areas, with integrated sludge trap, polyethylene quick release odor tight covers with integrated sludge trap and sloped walls for quick and efficient disposal, polyethylene quick release odor tight covers, with integrated suction system for disposal of grease and sludge contents,disposal flange DN 65, PN 10 (DIN 2501),Storz-B- coupling 2.5 inch for disposal truck connection, manually controlled disposal, cleaning and refilling system "E+S" with top mounted grease break up water jet(s) and water spray cleaning nozzles, with exterior connected macerating pump and closure valve, includes control unit for pump activation, with water re-fill inlet according to DIN 1988 - R1 connection, inspection window with cleaning lever. The "E+S" cleaning system serves to simultaneously macerate and mix the entire separator contents prior to disposal which eliminates the requirement of a pre-storage tank. The emptying of the separator shall be handled by a disposal pump. System shall be odor free grease separator disposal; No more than 3 liters of sludge remains after disposal. Separator inlet for connection to PE-HD pipe according to DIN 19537 and HT pipe according to DIN 19560 (PP or AS piping). Version: Right (can be changed to left side version by exchanging inlet and outlet). Size: NS 7 Warranty on polyethylene material : 20 years Delivered: Completely assembled. Pump control panesl shall be BMS compatable and intergrated to the BMS system. NS 10 [ 1W + 1S] Fully automatic
ELECTRICAL
CIRCUIT CUM POINT WIRING
Distribution wiring in 2X 22/0.3(1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire( Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make),with 1X22/0.3(1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch ( Brand approved by EIC) fixed on Moudular GI switch board with top cover plate and 2 No suitable size "Ph & N" copper bar & earthing arrangement fixed on wall inclusive mending good damages to original finish. (a) Avarage run 5 meter
(b) Avarage run 6 meter
(c) Avarage run 8 meter
(d) Avarage run 9 meter
(e) Avarage run 10 meter
(f) Avarage run 11 meter
(g) Avarage run 12 meter
Supplying & drawing 1.1 KV single core standard 'FR' PVC insulated & unsheathed single core standard copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. Connection as required. 2 X 1.5 sqmm+1X1.5 sqmm earth wire
2 X 2.5 sqmm+1X2.5 sqmm earth wire
2 X 4.0 sqmm+1X4.0 sqmm earth wire
2 X 6.0 sqmm+1X6.0 sqmm
2 X 10.0 sqmm+1X6.0 sqmm
4 X 2.5 sqmm+2X2.5 sqmm earth wire
4 X 4.0 sqmm+2X4.0 sqmm earth wire
4 X 6.0 sqmm+2X6.0 sqmm earth wire
4 X 10.0 sqmm+2X6.0 sqmm earth wire
4 X 16.0 sqmm+2X6.0 sqmm earth wire
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. 20mm
Supplying and fixing 240V, 6A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 3 Module GI Modular type switch board with 3 Module top cover plate flushed in wall inclusive S & F switchboard and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supplying and fixing 240V, 16A, 3 pin Modular type plug socket(Brand approved by EIC) with 16A Modular type switch,without plug top on 3 Module GI Modular type switch board with top cover plate flushed in wall inclusive S & F switchboard and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supplying and fixing 240V, 2 nos 6A, 3 pin Modular type plug socket (Brand approved by EIC) with 2 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall inclusive S & F switchboard and cover plate and making necessary connections with PVC Cu wire and earth continuity wire etc.
Supply and Fixing 240V, Modular socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate inclusive necessary connections etc.
Supply and Fixing 240V, 25A,3 pin Modular type plug socket with 20/25A Modular switch type MCB (C curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S & F switch board and cover plate and making neceesary connections with PVC Cu wire and earth continuity wire etc.
Supplying and fixing 240V, 6A, Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having Top cover plate and making necessary connections as required.
Supply & Fixing 240V,10A,2(Two) way Modular type switch (approvedmake) on existing GI Modular switch board having top cover plate and making necessary connections as required
Supplying and fixing 240V, 6A, 5 pin Modular type plug socket(Brand approved by EIC) without switch & Plug top on existing GI Modular type switch board with Top cover plate and making necessary connections with PVC Cu wire and earth continuity wire.
Supply and Fixing CRC sheet metal (16SWG) JB cum Switchboard of the following sizes complete with three no suitable size Copper bar with holes (for Ph,N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite /Perspex/colored Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment,painting and mending good damages to building works. 150mm X 100mm X 65mm
200mm X 150mm X 65mm
Supply and Fixing sheet metal inspection box(16SWG)of the following sizes flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 100mm X 100mm X 65mm
150mm X 100mm X 65mm
200mm X 150mm X 65mm
300mm X 200mm X 65mm
Supply and Fixing bakelite/perspex top cover on existing switchboard by Brass screws after making housing for switch by cutting bakelite/perspex cover and making connections as required. 100mm X 100mm X 65mm
150mm X 100mm X 65mm
200mm X 150mm X 65mm
300mm X 200mm X 65mm
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16SWG CRCA sheet with one end duly sealed by cover,properly welded, incl. S & F 12mm dai 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl binding the rod and fan box with reinforcement by 22 SWG steel binding wire,incl. supplying & covering the box with alkathene sheet,placed in order to prevent concrete from entering the box.
Supplying & Fixing G.I Modular Switch board of the following sizes complete with three no. suitable size Copper bar with holes(for Ph,N & E) fixed on bakelite/Hard Rubber insulator over the M.S welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment,paint and mending good damages to building works. 4 Module
6 Module
8 Module
12 Module
2 Row 12 Module
2 Row 18 Module
Supplying & Fixing G.I Modular Switch board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attacment,painting and mending good damages to building works. 2 Module
4 Module
a) Distribution wiring with circuit from DB to for light points with 3 x 2.5 Sq.mm. FRLS Cu wire by supplying and laying 20mm. dia. rigid FRLS PVC conduit with accessories in concealed and control the point by MCB including cutting the wall and mending good the damages,painting etc. as required. (complete the wiring in all respect) MCB controlled Primary Light point (Upto 32 Meter)
MCB controlled Secondary Light point (avg length 7 Mtr.)
b) Distribution wiring with circuit from DB to for light points with 3 x 1.5 Sq.mm. FRLS Cu wire by supplying and laying 20mm. dia. rigid FRLS PVC conduit with accessories in concealed and control the point by MCB including cutting the wall and mending good the damages,painting etc. as required. (complete the wiring in all respect) MCB controlled Primary Light point(Upto 10 mtr )
MCB controlled Seconary Light point (from point to point) (avg length 3.5 mtr)
c) Distribution wiring with circuit from DB to for light points with 3 x 2.5 Sq.mm. FRLS Cu wire by supplying and laying 20mm. dia. rigid FRLS PVC conduit with accessories in concealed and control the point by MCB including cutting the wall and mending good the damages,painting etc. as required. (complete the wiring in all respect) MCB controlled Primary Light point (Upto 40 mtr )
MCB controlled Seconary Light point (from point to point) (upto avg length 10 mtr)
DISTRIBUTION BOARD
Supplying and fixing following way, single pole and nuetral,sheet steel,MCB distribution board,240V,on surface/recess,complete with tinned copper bus bar,nuetral bus bar,earth bar,din bar,innterconnections,powder painted including earthing etc, as required.(But without MCB/RCCB/Isolator) 8 way,Double Door (2+6 way)
6 way,Double Door (2+4 way)
12 way,Double Door (2+12 way)
16 way,Double Door (2+16 way)
Supplying and fixing following way, three pole and nuetral,sheet steel,MCB distribution board,415V,on surface/recess,complete with tinned copper bus bar,nuetral bus bar,earth bar,din bar,innterconnections,powder painted including earthing etc, as required.(But without MCB/RCCB/Isolator) 4 way,(4+12),Double Door
6 way,(4+18),Double Door
8 way,(4+24),Double Door
Supplying and fixing following ways surface/recess mounting,vertical type, 415V,TPN MCB distribution Board of sheet steel,dust protected,duly powder painted ,inclusive of 200A,tinned copper bus bar,common nuetral link,earth bar,din bar for mounting MCBs(but without MCBs and Incomer) as required.(Note-Vertical type MCB TPDB is normally used where 3phase outlets are required) 4 way,(4+12),Double Door
8 way,(4+24),Double Door
12 way,(4+36),Double Door
Supplying and fixing following way, three pole and nuetral,sheet steel,MCB distribution board(DD), 415V,on surface/recess, complete with tinned copper bus bar,nuetral bus bar,earth bar, din bar,innterconnections,powder painted including earthing etc, as required.(But without MCB/RCCB/Isolator) 4 way,(8+12+12),Double Door
8 way,(8+12+24),Double Door
12 way,(8+12+36),Double Door
Supplying and fixing 5A to 32A rating,240/415V,10kA,"C" curve,MCB suitable for inductive load of following pole in the existing MCB DB complete with connections,testing and commissioning etc. as required. Single Pole
Double Pole
Triple Pole
Supplying and fixing following rating,double pole,240/415V,Isolator in the exising MCB DB complete with connections,testing and commisioning etc. as required. 40A
Supplying and fixing following rating,four pole,240/415V,Isolator in the exising MCB DB complete with connections,testing and commisioning etc. as required. 40A
Supplying and fixing following rating,double pole,240V,residual current circuit breaker(RCCB)having sensibilty current 30mA in the existing MCB DB complete with connections,testing and commisioning etc. as required. 25A
Supplying and fixing 415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Four Pole 40 A
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25A/32A,240V "C" curve DP MCB complete with connections,testing and commisioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/recess along with 16A/25A/32A,415V "C" curve TP MCB complete with connections,testing and commisioning etc. as required.
a) Supplying and fixing 20A,240V SPN Industrial type socket outlet,with 2 Pole and earth,metal enclosed plug top along with 20A,"C" curve,SP,MCB,In sheet steel Enclosure(IP 66/67 rated),on surface or in recess,with chained metal cover for the socket outlet and complete wiht connections,testing and commissioning etc. as required.
b) Supplying and fixing 30A,415V TPN Industrial type socket outlet,with 4 Pole and earth,metal enclosed plug top along with 30A,"C" curve,TP,MCB,In sheet steel Enclosure,on surface or in recess,with chained metal cover for the socket outlet and complete wiht connections,testing and commissioning etc. as required.
a) Supplying, installation and testing of 40A / 63A / 100A FP MCB with enclosure.
c) Supplying and fixing IP 68 enclosure with ventilation port.size 100mm x 100mm
d) Supplying and fixing IP 68 enclosure with ventilation port.size 300mm x 300mm
a) Supplying, installation and testing of 40A / 63A / 100A FP MCB with enclosure.
CABLE TRAYS & M.S CONDUITS :
a) Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable Tray (galvanisation thickness not less than 50microns) with perforation not more than 17.5%,in convenient section,joined with connectors,suspended from the ceiling with G.I.suspenders including G.I bolts & nuts, etc as required. 100 mm width x 50mm depth x 1.6mm thickness
150 mm width x 50mm depth x 1.6mm thickness
300 mm width x 62.5mm depth x 2.0mm thickness
450 mm width x 62.5mm depth x 2.0mm thickness
600 mm width x 62.5mm depth x 2.0mm thickness
CABLES
Suppling of following sizes 1.1 KV Grade conductor, XLPE insulated, PVC inner sheathed, PVC type ST-2 outer sheathed and Galvanized wire/flat strip armoured LT Power Cables conform to IS 7098 Part-I (latest edition) 3.5 core 300 sq. mm
3.5 core 150 sq. mm
3.5 core 50 sq. mm
3.5 core 35 sq.mm
4 core 25 sq.mm
4 core 6 sq. mm
4 core 16 sq. mm
3 core 6 sq. mm
Supplying of following 1100 volt grade XLPE insulated PVC sheathed copper conductor Armoured cable as per IS 7098(Part I)1988 including connecting testing and commissioning. 4 core 10 sq.mm armoured
4 core 6 sq.mm armoured
2 core 10sq.mm armoured
2 core 6sq.mm armoured
Compression Glands
Supplying and fixing compression type gland complete with brass gland,brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: i)For 2 core upto 6 sqmm
ii)For 2 core upto 10 sqmm
i)For 3 core upto 6sqmm
i)For 4 core upto 6 sqmm
ii)For 4 core upto 16sqmm
iii)For 4 core upto 25sqmm
i)For 3.5 core upto 35sqmm
ii)For 3.5 core upto 50sqmm
iii)For 3.5 core upto 150sqmm
iv)For 3.5 core upto 300sqmm
Finishing cable ends
Finishing the end of following XLPE/PVC aMeteroured cable by crimping method incl. supplying and fixing solderless socket(Dowel make).tapes,anticorrosive paste & Jointing materials: i)For 2 core upto 6 sqmm
ii)For 2 core upto 10 sqmm
i)For 3 core upto 6sqmm
i)For 4 core upto 6 sqmm
ii)For 4 core upto 16sqmm
iii)For 4 core upto 25sqmm
i)For 3.5 core upto 35sqmm
ii)For 3.5 core upto 50sqmm
iii)For 3.5 core upto 150sqmm
iv)For 3.5 core upto 300sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc , including supplying sockets,tapes etc. i) 2.5 sqmm
ii) 4.0 sqmm
iii) 6.0 sqmm
Laying on wall/Surface with saddles/clamps
Laying of cable upto 2core 25sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10SWG GI(Hot Dip) wire,making holes etc. as necessary mending good damages and painting.
Laying of cable upto 3/4core 25sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10SWG GI(Hot Dip) wire,making holes etc. as necessary mending good damages and painting.
Laying of cable upto 3/3.5 core 35sqmm to 50sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2X10SWG GI(Hot Dip) wire,making holes etc. as necessary mending good damages and painting.
Laying of cable upto 3.5 core 50sqmm to 3.5 core 90sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2X10SWG GI(Hot Dip) wire,making holes etc. as necessary mending good damages and painting.
Laying of cable upto 3/3.5 core 90sqmm to 3.5 core 150sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2X10SWG GI(Hot Dip) wire,making holes etc. as necessary mending good damages and painting.
Laying through RCC/Hume/GI Pipe
Laying only Cable upto 50sqmm through existing RCC/Hume/GI Pipe/Open masonary trench for single, 2,3,3.5 & 4 core
Laying only Cable above 50sqmm but not exceeding 400sqmm through existing RCC/Hume/GI Pipe/Open masonary trench for single, 2,3,3.5 & 4 core
Laying through Underground Trench
Laying of two cables upto 35sqmm and upto 185sqmm in underground trench in single tier formation(horizental),the trench size:680mm wide X 760mm avarage depth,with brick protection on the top of the cable with 8(eight) Nos bricks per metre and 4(four) Nos bricks per metre as separator between the bricks and cables and also the trench with shifted soil,levelling up and restoring surface duly rammed.
Laying of three cables upto 35sqmm in underground trench in single tier formation(horizental),the trench size:915mm wide X 760mm avarage depth,with brick protection on the top of the cable with 8(eight) Nos bricks per metre and 4(four) Nos bricks per metre as separator between the bricks and cables and also the trench with shifted soil,levelling up and restoring surface duly rammed.
Laying of three cables upto 35sqmm and upto 185 sqmm in underground trench in single tier formation(horizental),the trench size:915mm wide X 760mm avarage depth,with brick protection on the top of the cable with 8(eight) Nos bricks per metre and 4(four) Nos bricks per metre as separator between the bricks and cables and also the trench with shifted soil,levelling up and restoring surface duly rammed.
Laying of three cables above 185sqmm in underground trench in single tier formation(horizental),the trench size:915mm wide X 760mm avarage depth,with brick protection on the top of the cable with 8(eight) Nos bricks per metre and 4(four) Nos bricks per metre as separator between the bricks and cables and also the trench with shifted soil,levelling up and restoring surface duly rammed.
Laying through Masonary Trench
Laying of one cable upto 150sqmm through existing covered masonary trench incl. taking out RC covers,setting them in order,mending good the damages filling the trench with fine dry sand incl. supplying sand.
Laying of one cable above 150sqmm and upto 300 sqmm through existing covered masonary trench incl. taking out RC covers,setting them in order,mending good the damages filling the trench with fine dry sand incl. supplying sand.
Laying through Floor/Pavement/Wall
Laying of cable as below,after cutting floor/pavement/wall and making holes incl. embedding the cable at an avarage depth as below and mending good the damages to original finish incl. removing the rubbish. From 2.5sqmm to 35sqmm at an avarage depth of 75mm in floor/Pavement/wall etc.
Above 35sqmm to 95sqmm at an avarage depth of 100mm in floor/Pavement/wall etc.
Above 95sqmm at an avarage depth of 100mm in floor/Pavement/wall etc.
Laying on Cable Tray
Laying of cable as below,on existing Cable Tray and binding with suitable size GI wire. Upto 50 sqmm
From 70 sqmm to 150 sqmm
Above 150 sqmm
Providing,laying and fixing following dia G.I pipe(medium class)in ground complete with G.I fittings including trenching(75cm deep) and refilling etc as required. 150mm. dia.
100 mm. dia.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. This pipes will be used for transferring HV/LV Cables. 63 mm dia (OD-90 mm & ID-76 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
160 mm dia (OD-160 mm & ID-135 mm nominal)
200 mm dia (OD-200 mm & ID-175 mm nominal)
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia
100 mm dia
EARTHING INSTALLATION
Earthing with 50mm dia GI pipe 3.64 mm thick X 3.04Mtrs long and 1 X 4 SWG GI (Hot Dip) wire (4 Meters Long), 13mm dia X 80 mm long GI bolts,double nuts,double washers incl. S & F 15mm GI pipe protection (1 Meters long) to be filled with bitumen partly under the ground level and partly above ground level driven to an avarage depth of 3.65 meters below the ground level as below: a)By TATA Medium GI pipe
Earthing with Copper plate(610 X 610 X 3mm size)having weight of 9.84Kg and 1 no 25 X 5 mm copper strip(3.20 meter long) & 1 nos 6 sqmm PVC insulated stranded copper wire(4 meter long) inclusive S & F 15mm dia GI pipe(ISI medium) protection ( 4 meter long)to be filled with bitumen,partly under the ground level & partly above ground level to an avarage depth of 3.65 meters below the ground level and restoring the surface duly rammed incl. providing 3 meter long ,25mm dia GI pipe(ISI medium) for periodic treatment,incl providing masonary enclosure on the top of the earth electrode of overall size 86.36 X 86.36 X 46 cm deep(below ground level)complete with cemented brick work(1:6) of 25cm width ,duly plastered with cement morter(inside) CI hinged inspection cover of size 36.56 X 35.56cm with locking arrangement,GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode. (for Substation Neutral,UPS earthing)
Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36cm X 86.36cm X 46cm deep (below Ground Level)complete with cemented brick work(1:6) of 25cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56cm X 36.56cm with locking arrangement,GI reducer including drilling 46 Nos 12mm dia holes onthe GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbur of galvanaized (Hot Dip) MS flat 25mm X 6mm on wall having clearence of 6mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts,washers,spacing insulators etc. as required.
Supplying & fixing earth busbur of galvanaized (Hot Dip) MS flat 50mm X 6mm on wall having clearence of 6mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts,washers,spacing insulators etc. as required.
Earth Continuity Conductor
Connecting the equipments to earth busbar including S & F GI(Hot Dip)wire of size as below on wall/floor with staples burried inside wall/floor as required and making connection to equipments with bolts,nuts,washers,cable lugs etc as required and mending good damages. GI wire 8 SWG
Connecting the equipments body to earth busbar including S & F 20 mm X 3mm galvanised (Hot Dip)MS flat on wall/Floor with GI saddles as required and connection to equipments incl. drilling holes,with bolts,nuts,washers etc.
Connecting the equipments body to earth busbar including S & F 25 mm X 6mm galvanised (Hot Dip)MS flat on wall/Floor with GI saddles as required and connection to equipments incl. drilling holes,with bolts,nuts,washers etc.
Connecting the equipments body to earth busbar including S & F 50 mm X 6mm galvanised (Hot Dip)MS flat on wall/Floor with GI saddles as required and connection to equipments incl. drilling holes,with bolts,nuts,washers etc.
Providing and laying earth conductors of copper strip / wire including necessary accessories, clamping to walls, cables etc, as required and interconnection between the lengths as per specifications and as per good installation practice. The rate shall include all supports, accessories and hardware necessary for proper installation. 50 x 6mm copper strip
32 x 6mm copper strip
CABLING,INSTALLATION & TESTING OF LIGHTING FIXTURE FOR EXTERNAL / LANDSCAPE LIGHTING
Wiring for circuit/Submain wiring alonwith earthwire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required. 3 x 4 sq.mm wire in medium class PVC conduit.
3 x 2.5 sq.mm wire in in medium class PVC conduit.
3 x 1.5 sq.mm wire in in medium class PVC conduit.
Supply, Laying, dressing, clamping, testing and commissioning of 1.1 KV Grade, Flat Three Core PVC Insulated & PVC Sheathed Industrial Submersible Cable of 2.5 sq.mm. size. The cable run through on ground / floor / wall etc. The work shall includes supplying and fixing necessary termination of cable and etc. as required.
Supply, installation, testing and commissioning of outdoor typE weather proof (IP-66/69) junction box(130x130x77mm deep) with clamp & terminals as per PWD schedule.
Supply, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in the feeder Pillar/DB for Automatic switching On & Off of Street Light at Sun Set & Sun Rise with manuall override facility with 12/24hour display format etc complete as required. 3 Output(1 Output per phase) and suitable for three phase supply
2 output per phase and suitable for single phase supply
1 output per phase and suitable for single phase supply
SUPPLY & INSTALLATION OF FITTINGS & FIXTURES :
Fixing only all type light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 300mm diameter. 30 cm (12")
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 300mm dia. Exhaust Fan. For 30 cm (12") Exhaust fan
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding odular plate as required.
FITTINGS AND FIXTURES
supply of 1x20 watt LED batten recessed type light fittings (Wipro Type LL20-281-XXX-65AL1 or Equivalent approved make) FTL : DIRECTLY ON WALL/CEILING
Ceiling fan (Bajaj or euivalent make) 1200mm.dia.complete with blades, canopy, fork, rubber, bush etc.
Supply & Installation of exhaust fan 300mm sweep complete with louver,grouting nuts, bolts etc. making suitable size hole to accomodate the fan, plustering and all accessories including supply of PVC copper wire and connection. ( Bajaj or equivalent)
Supply of wall/column mounted air circulator fan (Havells make model or equivalent) Ssize : 450mm dia
supply of 9 watt bulk head type light fittings (Wipro type 9W LW01-101-XXX-60-XX or Equivalent approved make)
supply of medium intensity aviation obstruction light
PANELS & FEDDER PILLAR:
Busbar: 1 Set - 250A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA OUTGOING FEEDERS: 125A MCCB Outgoing : 1 No. Each comprising of 1 no. 125A 4P 25 KA MCCB with O/L, S/C, TM Rel, and complete with 1- Indicating Lamp, Control MCB & accessories as required. 40A MCB Outgoing : 7 Nos. Each comprising of 1 no. 40A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
Busbar: 1 Set - 250A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA. OUTGOING FEEDERS: 40A MCB Outgoing : 21 Nos. Each comprising of 1 no. 40A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
OUTGOING FEEDERS: 40A MCB Outgoing : 14 Nos. Each comprising of 1 no. 40A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
Busbar: 1 Set - 250A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA. OUTGOING FEEDERS: 125A MCCB Outgoing : 1 No. Each comprising of 1 no. 125A 4P 25 KA MCCB with O/L, S/C, TM Rel, and complete with 1- Indicating Lamp, Control MCB & accessories as required. 40A MCB Outgoing : 11 Nos. Each comprising of 1 no. 40A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
Busbar: 1 Set - 250A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA. OUTGOING FEEDERS: 100A MCCB Outgoing : 1 No. Each comprising of 1 no. 100A 4P 25 KA MCCB with O/L, S/C, TM Rel, and complete with 1- Indicating Lamp, Control MCB & accessories as required. 40A MCB Outgoing : 15 Nos. Each comprising of 1 no. 40A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
Busbar: 1 Set - 600A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA. OUTGOING FEEDERS: 100A MCCB Outgoing : 7 Nos. Each comprising of 1 no. 100A 4P 25 KA MCCB with O/L, S/C, TM Rel, and complete with 1- Indicating Lamp, Control MCB & accessories as required. 63A MCB Outgoing : 6 Nos. Each comprising of 1 no. 63A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
Busbar: 1 Set - 200A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA. OUTGOING FEEDERS: 63A MCB Outgoing : 6 Nos. Each comprising of 1 no. 63A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
Busbar: 1 Set - 250A, 415V, 50 Hz, symmetrical continious rated Aluminium Busbars mounted on suitable hylam/ DMC/ SMC insulators/ supports with proper graded colour coded heat shrinkable PVC sleeves. Surge protection device with rated KA. OUTGOING FEEDERS: 125A MCCB Outgoing : 1 No. Each comprising of 1 no. 125A 4P 25 KA MCCB with O/L, S/C, TM Rel, and complete with 1- Indicating Lamp, Control MCB & accessories as required. 63A MCB Outgoing : 8 Nos. Each comprising of 1 no. 63A 4P 10 kA MCB with O/L, S/C, and complete with 1- Indicating Lamp, Control MCB & accessories as required. Complete the above as stated.
1 set - 25mm X 6mm GI Earth Bus Bar running along the base frame covering entire length of the panel with high tensile bolts, nuts, etc. and number of drilled as required for earth connection at both ends. LIGHTING FEEDER PILLAR (Outdoor Type) Supplying,Testing & Commisioning of following Fedder Pillars complete with all respect 1 no. 63A, 4P MCB (10 KA) with O/L & S/C Protection. 1 no. Astronomical time switch of 3 output (1output per phase) and suitable for three phase supply to be mounted in feeder pillars for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. Instrumental Component : 1 no. LED type indicating lamp for incoming with 6A TPN MCB. Busbar component : 1 set. 100A, 415V, 3PH, 4 Wire, 50 HZ. aluminium busbar. 1 no. 25mm x 6mm G.I. earth busbar. Outgoing component : 12 nos. 32A, DP MCB (10 KA) with O/L & S/C Protection.
UPS SYSTEM
Supply, installation, Testing and commissioning of the following rating UPS as per direction of EIC and complete in all respects: 10 KVA UPS with 30 min battery backup of 3 phase input & 3 phase output
6.0 KVA UPS with 30 min battery backup of 1 phase input & 1 phase output
.750 VA UPS with 30 min battery backup of 1 phase input & 1 phase output
LIGHTNING PROTECTION SYSTEM
CONVENTIONAL TYPE S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium ) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar(4:2:1)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: (a) Length upto 0.5 Mtr
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/ Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
S & F of GI (Hot Dip) strips 20mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work 4e damages to building works (excluding hire charges of scaffolding)
Making soldered (welding) joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Supply & fixing of Testing joints by 20mm x 3mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Earthing with 50mm dia GI pipe 3.64 mm thick x 3.04 mts. Long and 1 x 4 SWG GI ( Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level (a) By TATA-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming (a) For Soft soil
Connecting the equipments body to earth busbar including S & F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/ floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.(For Equi- Potential Bonding)
ESE TYPE: Supply, installation, testing and commissioning of CPRI tested 5 Meter Air terminal (ESE Method) with all accessories complete as required. (for 107 meter protection radious)
Supply and installation of 50 mm dia 5 meter long G.I Mast with base plate and adapter. as required
Supply and installation of guy kit suitable for 5 mtr mast with W.R.Grips etc as required complete.
Supply and installation of SS cable ties as required complete.
Supply and installation of 70 sq.mm. insulated copper cable as required complete.
Supply and installation of conductive saddles as required complete.
Supply and installation of fixings for conductive saddles as required complete.
Supply and installation of lightning event counter as required complete.
Supply and installation of 25mm x 6mm copper strip as required complete.
Supply and installation of copper bonded Earth rod 17.2mm dia (3000mm long) as required complete.
Supply and installation of earth rod clamp as required complete.
Supply and installation of Ground Enhancement Material (GEM) Each Bag of 11.3 k.g as required complete.
Supply and installation of lower termination kit as required complete.
SUBSTATION PART
Section I: 11 KV Single Panel VCB Switchboard 11 KV CONSUMER SINGLE PANEL VCB SWITCH BOARD Supply, Installation, Testing & Commisioning of 11 KV, 25 KA for 3 sec, 630A, 3 Ph, 50 Hz, Indoor, sheet steel enclosed, floor mounting, free standing, horizontal isolation & horizontal drawout type 3 Panel VCB 11 KV HT switch board comprising of 1- Incoming feeder breaker (VCB) panel with Line PT to receive power from Supply Authority, 2- Outgoing feeder breaker (VCB) panel for feeding 2 nos. 630 KVA, 11 KV / 415 V, Dry type transformer. The 11 KV VCB board shall be complete with all measuring and protective devices, bus-bar, CT, PT etc. as per specification & drawing and relevant standard. The scope of erection includes earthing of the VCB Switch Board at two points, all alignments, leveling, coupling and assembly of panels & bus bars including assembly of dis-assembled /split up sections, loosely supplied relays, meters, bus-bars etc., grouting, bolting, fabrication and fixing of base channel as per manufacturer's/ client's recommendation and site condition. The Scope also includes checking of closing & tripping mechanism, checking and setting of Relays, minor wiring modification if required, and site testing. The job to be executed to the full satisfaction of engineers of client/consultant and other statutory authority. Checking to be done for insulation resistance by megger. 1.1 MATERIAL: 11KV CONSUMER 3 PANEL VCB SWITCH BOARD SHALL BE ISSUED BY EMPLOYER AS FREE ISSUE ITEM AT SITE.
SUPPLY AND INSTALLATION :: 11 KV/415V DRY TYPE TRANSFORMER Supply and installation of 11kV/415 V, 630 kVA, 3Ph, 50Hz. Delta/Star, copper wound, Dyn11, Resin Cast dry type transformer suitable for indoor installation, (+/-) 10% voltage variation and (+/-) 5% frequency variation. The transformer shall have Off-load tap changing switch in HV side of range (+) 7.5% to (-) 7.5% in five steps @ 2.5% per step, seperate neutral bushing for earthing and all standard accessories including 'Winding Temperature Scanner', Marshalling box, Tap-door Limit Switches etc. as per specificationas and relevant standard/norms. "The transformer shall be complete with all standard accessories including the following: i) HV cable end box with detachable gland plate suitable for end termination of up to 1x3Cx300 Sq. mm. 11 KV (E) Gr. XLPE Al. cable. ii) LV side cable end box with detachable gland plate & link bus-bar suitable for end termination of up to 4 nos. of 3.5C x 400 Sq.mm. 1.1 KV Grade XLPE cable." iii) Lifting lugs for core coil assembly. iv) Lifting lugs for lifting of entire transformer. v) Arrangement for lifting of enclosure only. vi) Perforated sheet at bottom & Louvers with mesh on all sides of enclosure for proper air circulation. vii) Under carriage with jacking pads and haulage holes." viii) Bidirectional rollers with locking arrangement.
ix) Earthing terminals with lugs. x) Winding temperature scanner with potential free contact for alarm, trip and fan operation, duly wired up to marshalling box. xi) Rating and diagram plate. xii) Off circuit tapping link with (+) 7.5% to (-) 7.5% in steps of 2.5% each." xiii) LV side extra neutral bushing (outside LV cable box) for neutral earthing. xiv) Tap-door limit switches (heavy duty type) duly wired up to marshalling box. xv) Marshalling box. xvi) Provision/arrangements shall be kept for fixing/fitting & connection of ‘Air Blowers’ for cooling purpose. ix) Earthing terminals with lugs. x) Winding temperature scanner with potential free contact for alarm, trip and fan operation, duly wired up to marshalling box. xi) Rating and diagram plate. xii) Off circuit tapping link with (+) 7.5% to (-) 7.5% in steps of 2.5% each." xiii) LV side extra neutral bushing (outside LV cable box) for neutral earthing. xiv) Tap-door limit switches (heavy duty type) duly wired up to marshalling box. xv) Marshalling box. xvi) Provision/arrangements shall be kept for fixing/fitting & connection of ‘Air Blowers’ for cooling purpose. ix) Earthing terminals with lugs. x) Winding temperature scanner with potential free contact for alarm, trip and fan operation, duly wired up to marshalling box. xi) Rating and diagram plate. xii) Off circuit tapping link with (+) 7.5% to (-) 7.5% in steps of 2.5% each." xiii) LV side extra neutral bushing (outside LV cable box) for neutral earthing. xiv) Tap-door limit switches (heavy duty type) duly wired up to marshalling box. xv) Marshalling box. xvi) Provision/arrangements shall be kept for fixing/fitting & connection of ‘Air Blowers’ for cooling purpose. xvii) 2 nos. Neutral CTs, 600/1A of suitable VA burden and accuracy Class for stand-by E/F and REF protection (Accuracy Class: ‘5P10’ for E/F & ‘PS’ for REF).
11 KV HT CABLES LAYING AND TERMINATION
11 KV HT CABLE- SUPPLY Suppling of 11 KV earthed Grade, stranded compacted circular Aluminium conductor, conductor screen with extruded semiconducting compound, XLPE insulated, insulation screen, extruded PVC inner sheathed, armoured, PVC type ST-2 outer sheathed cable conforms to IS 7098 (Part-II) of following size in ready concrete/brick trenches on trays/floor as per relevant standered and specification. 3C X 300 Sq.mm.-11KV (E) Grade XLPE
11 KV HT CABLE- LAYING Laying, dressing, clamping, testing and commissioning of 11 KV earthed Grade, stranded compacted circular Aluminium conductor, conductor screen with extruded semiconducting compound, XLPE insulated, insulation screen, extruded PVC inner sheathed, armoured, PVC type ST-2 outer sheathed cable conforms to IS 7098 (Part-II) of following size in ready concrete/brick trenches on trays/floor as per relevant standered and specification. The scope of work for laying includes - i) Laying of cable in 'Masonary Trench' /Hume pipe as per relevant standard and practice /norms. Work includes Minor civil work as required. Testing of insulation resistance before and after laying. 3C X 300 Sq.mm.-11KV (E) Grade XLPE
11 KV HT CABLE- END TERMINATION supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C X 300 Sq.mm. 11 KV (E) Gr. XLPE cable (Indoor)
SUB STATION ACCESSORIES
ACDB Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 8 Way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32A SP
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 100A , 4P, 30kA MCCB
Supply,Installation, testing and commissioning of 2 KVA UPS with 30 minute back up for uninterrupted 230V A.C Aux. power supply for control circuit of LT panels. The UPS shall be complete with suitable battery for fifteen minute back-up and all other accessories as required as per detail below. Nominal Input Voltage: 230 volt A.C. 1 phase ( P + N + E ) Input Voltage Range: 80-280 Volts Nominal Frequency: 50 HZ Input Frequency Range: 50HZ +/- 5 Hz Output Voltage: 230 volt A.C. 1 phase ( P + N + E ) Output Voltage Variation: +/- 2% Output Frequency: 50 HZ Output Frequency Variation: +/- 0.5 HZ. Output Overload Capacity: Overload capacity of 120% for 10 mins and 150% for 1 minute The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge.
1-Auto/Manual switch, 2- Indicating lamps for 'Auto/Manual Status' Indication, 1- APFC Relay (3 CT type- Single source), Set of Control equipments like Aux. Contactors, Timers, Time Switch, Control MCB & accessories as required as per specification & drawing. " "ii) 60 KVAR (2x30 KVAR) Capacitor O/G feeders: 3 Set. Each set. comprising of 1- 125A 35 KA TP MCCB with TM Release, 6- 63A HRC Fuse with 125A Fuse Base, 2- 30 kVAR 480V grade, Delta Connected, 'Super Heavy Duty type' Capacitor suitable for non-linear load up to 25%, 2- Capacitor Duty TP Contactor suitable for above Capacitors, 1- Indicating Lamp for Capacitor 'ON' indication, 2-Push Button Capacitor 'ON' & 'OFF' (Manual Mode), Set of Control equiments Control MCB & accessories as required as per specification & drawing. " "iii) 30 KVAR (1x30 KVAR) Capacitor O/G feeders: 1 Set. Each set. comprising of 1- 63A 35 KA TP MCCB with TM Release, 1- 30 kVAR 480V grade, Delta Connected, 'Super Heavy Duty type' Capacitor suitable for non-linear load up to 25%,
1- Capacitor Duty TP Contactor suitable for above Capacitors, 1- Indicating Lamp for Capacitor 'ON' indication, 2-Push Button Capacitor 'ON' & 'OFF' (Manual Mode), Set of Control equiments Control MCB & accessories as required as per specification & drawing. " "iv) 15 KVAR (1x15 KVAR) Capacitor O/G feeders: 4 Sets. Each set. comprising of 1- 63A 35 KA TP MCCB with TM Release, 1- 15 kVAR 480V grade, Delta Connected, 'Super Heavy Duty type' Capacitor suitable for non-linear load up to 25%, 1- Capacitor Duty TP Contactor suitable for above Capacitors, 1- Indicating Lamp for Capacitor 'ON' indication, 2-Push Button Capacitor 'ON' & 'OFF' (Manual Mode), Set of Control equiments Control MCB & accessories as required as per specification & drawing. "
NOTES FOR AUTO/MANUAL APFCR PANEL: a) The capacitors shall be of 480V Grade, Delta Connected, 'Super Heavy Duty Type' suitable for non-linear load up to 25%. b) Capacitor output as specified is at 480V. c) APFC Relay shall be of 3-CT type (single source). d) Pair of Exhaust fans (9') per capacitor compartment along with 'Time Switch' (24 Hr) to be provided for smooth air circulation inside the panel enclosure and for cooling of capacitors. Time switch to be provided for running of fans alternatively in preset time interval. SITC OF 'AUTO/MANUAL POWER FACTOR CORRECTION PANEL' SHALL BE ISSUED BY EMPLOYER AS FREE ISSUE ITEM AT SITE.
LT POWER & CONTROL CABLE
LT POWER CABLE (SUPPLY) Suppling of following sizes 1.1 KV Grade conductor, XLPE insulated, PVC inner sheathed, PVC type ST-2 outer sheathed and Galvanized wire/flat strip armoured LT Power Cables conform to IS 7098 Part-I (latest edition) i) 3.5C x 35 Sq. mm. Al. Arm.
ii) 3.5C x 300 Sq. mm. Al. Arm.
LT POWER CABLE (LAYING) a) Laying of one cable above 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order,mending good the damages filling the trench with fine dry sand incl. supplying sand i) 3.5C x 300 Sq. mm. Al. Arm.
b) Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire. i) Upto 50 sqmm
ii) Above 150 sqmm
END TERMINATION
Supplying and making end termination with brass compression double gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. i) 3.5C x 35 Sq. mm. Al. Arm.
ii) 3.5C x 300 Sq. mm. Al. Arm.
LT CONTROL CABLE
Supply of following sizes stranded copper conductor, PVC insulated, PVC inner sheathed, PVC outer sheathed 1.1 KV grade Galvanized wire/strip armoured control cable conform to IS 1554 (Part-1). i) 7C x 2.5 Sq. mm.
ii) 2C x 2.5 Sq. mm.
iii) 2C x 4 Sq. mm.
DISTRIBUTION BOARD
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. SPN 2+12 way MCB DB comprising the following : [Enclosure (DHDPSNODRW12)]
Incomer 1 No. 32A DP MCB, 10 KA, C Curve
Outgoing 12 Nos. 6A to 20A SP MCB (As per SLD), 10 KA, C Curve Complete
STEEL CONDUIT :
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. STEEL CONDUIT : 25 MM DIA
STEEL CONDUIT : 20 MM DIA
CIRCUIT WIRING:
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
POINT WIRING
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
POWER SOCKET.
6/16A PLUG SOCKET Supply & Fixing 240 V, 16 A, 3 pin/5 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Installation of Fitting & Fixtures :
Fixing only all type light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of 450mm diameter. 38 cm (15")
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) for 300mm dia. Exhaust Fan. For 38 cm (15") Exhaust fan
FITTINGS AND FIXTURES
SIT&C of surface mounted LED Batten with 34W and >3800 Lumen with a lumen efficacy >110 Lm/Watt. (BN100C LED40S-6500 PSU L120 GR S4 (SMARTBRIGHT XTRA S4) OR SIMILAR APPROVED EQUIVALENT) LIGHT FITTINGS : SRFACE MOUNTED BATTEN
SIT&C of surface mounted LED Batten with 18W and >2000 Lumen with a lumen efficacy >115 Lm/Watt. (BN100C LED20S-6500 PSU L120 GR S4 (SMARTBRIGHT XTRA S4) OR SIMILAR APPROVED EQUIVALENT) LIGHT FITTINGS : SRFACE MOUNTED BATTEN
Supply & Installation of 1200mm Sweep,3-Blade 5-star rating AC ceiling fan. (HAVELLS ES-50 OR SIMILAR APPROVED EQUIVALENT)
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supply of 380mm,1PH,900RPM heavy duty exhaust fan.(HAVELLS TURBO FORCE SP OR SIMILAR APPROVED EQUIVALENT)
EARTH STATION
COPPER PLATE EARTHING Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1no. 6 sqmm PVC insulated stranded Copper wire (4 t long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts.below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode
GI PIPE EARTHING Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode.
EARTHING STRIPS Supplying, laying and connection of earthing strips shall run on wall / cable trench/ Floor/ Wall/Ceiling/Cable tray/ below the earth soil (including excavation) from earth station to equipment Neutral/ equipment body with accessories like earthing clamp, saddle etc fixing/jointing accessories as required. The strip should be laid as per drawing & as per instruction & satisfaction of EIC / Representative of Consultant. i) 75x6 mm. Cu earth strip for Equipotential Bonding & Neutral Earthing of Transformers & DGs.
ii) 50x6 mm. GI strip (for body earthing of DG sets & etc.).
iii) 65x8 mm. GI strip (for body earthing of Transformers.).
MISC EARTHING WORK
Supply, fabrication and erection of earth bus 'test link' by 75 x 6 mm. GI strip, drilling hole, grouting on wall and connection with earth station.
Supply of material and earthing of sub-station doors and windows with braided copper/cu wire as per rule/norms.
SAFETY EQUIPMENTS
Supply and Installation of following safety items i) 11KV Grade Chequered Rubber Mat (2 Mtr. x 1 Mtr.) x 12 mm Thick.
ii) 415V Grade Chequired Rubber Mat (2 Mtr. x 1 Mtr.) x 6 mm. Thick
iii) 4.5 Kg. Carbon Di-oxide type Fire Extinguisher
iv) 3 Nos. Fire bucket with Stand
v) HT & LT Danger Plate/Board
vi) Shock Treatment Chart (in wooden frame)
vii) First Aid Box with Medicine
SERVICE JOBS
High pressure testing of HT equipments like Transformers, HT Cable, HT VCB and submission of test report to the office of the relevant statutory authority and obtaining approval of the same for commissioning of the system.
Preparation of Single line diagram and layout drawing of the proposed 11/0.415KV sub-station, as per Statutory norms and submission and obtaining approval of the same from the relevant Authority.
Commissioning of the 11 KV HT sub-station
Co-ordination and follow-ups with statutory and supply authority for expediting and obtaining approval for the energisation of the HT sub-station
DG BOQ
"SUPPLY & INSTALLATION Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc." The scope includes design, supply, all interconnection, installation of exhaust piping and commissioning of the DG Sets. including obtaining clearance/approval from statutory authority. ambiant temp. 50 degree C 650 KVA ( WITH CANOPY )
Ceilling fan 52″ Antique wooden pattern(brass or aluminnium ) Ceiling Fan A vintage charm fan features dark brown blades, an antique brass/aluminnium finish body, and a remote control or without remote for convenient operation. This beautiful fan boasts a classic design with 5 rich dark brown blades complemented by a stunning antique brass finish. The blade span is ideal for medium to large rooms, providing ample airflow for year-round comfort. size 1400 mm,cfm 9500,db level max 40db
Description of store Electric Ceiling Fan: BLDC type Electric ceiling fan conforming to IS: 374:2019 latest BIS License number must declare. BEE Star Rating of the product 5 Star Rating Plan as per Gazette Notication Number: S.O. 2210 (E) and S.O. 2211 (E) dated. 12th May 2022 Size of ceiling fans (in mm) 1400 Number of blades (in Nos) 3 Type of Regulator Without Regulator Number of running position NA for Without Regulator Speed regulator operation Using remote control Input voltage 1 Phase, 230 V, 50 Hz, AC Power factor, Minimum 0.9 Total Harmonic Distortion (%) < 20 Input power (in Watts) as per star rating label - Must declare Ceiling fans driven by Brushless DC motor Blade Material Aluminum Blade thickness (in mm) :1.1 Type of bearing: Double ball bearing
EXTERNAL LIGHT
SITC 26,000 lumen output via 680W 6,500K light engine, IP65 (IP66 with anti-tamper box installed), CMYC Color Mixing system, Zoom 5.4˚ to 44˚, 1 x Rotating Gobo Wheel delivering 7 all new designs 1 x Static Gobo Wheel delivering 8 all new designs, 1 x Animation wheel (new design), Color Wheel with Spectral Enhancement filter pre-installed (CRI 90) Full curtain framing system, 2 x Prism (Linear and circular), 2 x Frost (heavy and medium),DMX/RDM and Art-Net/sACN via network with bypass Color mixing: CMY, independently variable 0-100% Color wheel: 7 color filters plus open (incl, Spectral Enhancement Filter) Gobo animation: Animation wheel, indexing, continuous rotation with variable speed and direction, shake (flow) Rotating gobo wheel: 7 gobos plus open, wheel rotation, gobo rotation, indexing and shake Static gobo wheel: 8 gobos plus open, wheel indexing, rotation and shake Iris: 0-100% Zoom: Motorized Color temperature control: Variable 6,500 - 2,700 K Framing: Rotatable framing module, +/-60°, with 4 individually controllable full framing blades with variable angle and position. Prism: 2 rotating/indexing prisms (4-facet circular prism and 6-facet linear) Frost: Soft frost effect and heavy frost effect Electronic dimming: 0 - 100%, four dimming curve options Electronic shutter effect: Strobe effect, pulse effects, instant open and blackout Pan: 540°, coarse & fine control and speed Tilt: 270°, coarse & fine control and speed Focus: Motorized` APPROVED MAKE: MARTIN or equivakent
Street lighting luminaire (Double Arm) mounted on 6 mtr high GI pole, IP66, IK 07, - Die-cast aluminium housing, pre-treated before powder coating ensuring high corrosion resistance (fixture color RAL matching with overall landscape colors) - One IP68 connector supplied with 0.5 m of 3x1.0 sqmm outdoor cable, Clear toughened glass, - High-efficiency polycarbonate lens, - Integral control gear - Surge protection 10kV, Material Aluminium Light source 2 x 24 LED, Power 106 W (2X53W), Lumen 12252 - 14054 lm, Efficacy 116 - 133 lm/W, Driver-ON/OFF driver, Input voltage 220-240 V, Optical options- Medium, Wide, Extra wide, T2, T3, T4, ME, CCT - 3000K CRI-80, Operating temperature -20 °C to 50 °C, EPA (m2) 0.286, Cable One IP68 connector supplied with 0.5 m of 3x1.0 sqmm, outdoor cable Through wiring Single cable entry, Lens / Reflector / Optic Clear toughened glass, Highefficiency polycarbonate lens, SDCM ≤ 3 , Lifetime L90B10 (hours) > 90,000. Column to have die casted clamps , GI pole powder coated , colour matching RAL for pole and fixture to gel with landscape areas (luminaires and poles preferably from same OEM). APPROVED MAKE: SIMES/LIGMAN/WEEF or Equivalent
Street lighting luminaire (Single Arm) mounted on 6 mtr high GI pole, IP66, IK 07, - Die-cast aluminium housing, pre-treated before powder coating ensuring high corrosion resistance (fixture color RAL matching with overall landscape colors) - One IP68 connector supplied with 0.5 m of 3x1.0 sqmm outdoor cable, Clear toughened glass, - High-efficiency polycarbonate lens, - Integral control gear - Surge protection 10kV, Material Aluminium Light source 2 x 24 LED, Power 106 W (2X53W), Lumen 12252 - 14054 lm, Efficacy 116 - 133 lm/W, Driver-ON/OFF driver, Input voltage 220-240 V, Optical options- Medium, Wide, Extra wide, T2, T3, T4, ME, CCT - 3000K CRI-80, Operating temperature -20 °C to 50 °C, EPA (m2) 0.286, Cable One IP68 connector supplied with 0.5 m of 3x1.0 sqmm, outdoor cable Through wiring Single cable entry, Lens / Reflector / Optic Clear toughened glass, Highefficiency polycarbonate lens, SDCM ≤ 3 , Lifetime L90B10 (hours) > 90,000. Column to have die casted clamps , GI pole powder coated , colour matching RAL for pole and fixture to gel with landscape areas (luminaires and poles preferably from same OEM). APPROVED MAKE: SIMES/LIGMAN/WEEF or Equivalent
SITC 25 mtr Highmast with rasing & lowering meachanism having 12 nos. of Flood light fixtures each with 113W,IP66, IK08, - Extruded aluminium housing , Pre-treated before powder coating ensuring high corrosion resistance , Galvanized steel arm mounted, Thermal heat dissipation body - Single cable entry, through wiring upon request, One IP68 connector supplied with 0.2 m of 3x1.0 sqmm outdoor cable - Stainless steel fasteners in grade 304 with zinc flake coating (ZFC), Durable silicone rubber gasket - High-efficiency polycarbonate lens, Clear toughened glass, Integral control gear, Surge protection 10kV, Material Aluminium , Light source 2 x 36 LED, Power 113 W, Lumen 10433 - 16865 lm, Efficacy 92 - 149 lm/W, Integral ON/OFF driver suitable for Input voltage 220-240V, Optic options - Narrow, medium, wide, very wide, extra wide, T1, T2, T3, T4, ME, CCT= 3000K CRI=80, Operating temperature -20 °C to 50 °C, EPA (m2) 0.191 Cable One IP68 connector supplied with 0.2 m of 3x1.0 sqmm outdoor cable Through wiring Single cable entry, through wiring upon request Lens / Reflector / Optic High-efficiency polycarbonatelens, Clear toughened glass, SDCM ≤ 3. Approved Make - MEYER/LIGMAN/SIMES/SILL or equivalent
SITC Outdoor In-ground luminaires , 33W, IP68, IK 10, With recessing box / driver - Adjustable: Tilt 25° / Rotation 360°, - Die-cast stainless steel in grade 316 , Body is pre-treated before powder coating ensuring high corrosion resistance - Front ring in grade 316 stainless steel - Externally adjustable: Tilt 25°, Rotation 360°, Single cable entry, through wiring upon request One cable gland supplied with 1 m of 3x1.0 sqmm outdoor cable, Stainless steel fasteners in grade 316, - Durable silicone rubber gasket - High-efficiency PMMA lens , Clear, 15mm thick, toughened glass, - Integral control gear, Recessing box in high-density polyethylene is included, - Suitable for drive-over with a maximum load of 5000 kg, Material Stainless Steel, Lumen 3664 - 4602 lm Efficacy 111 - 139 lm/W, Driver option Integral control gear Driver Constant current (CC), Input voltage 220-240V, Optic M, W, E, CCT = 3000K, CRI=80, On/Off driver, Product colours Stainless Steel, Weight 17.0 kg, Operatingtemperature -20 °C to 50 °C, Cable One cable gland supplied with 1 m of 3x1.0 sqmm outdoor cable Through wiring Single cable entry, through wiring upon request. Dimensions: Diameter: 290mm, height-270mm Approved Make - SIMES/LIGMAN/HOFFMEISTER or equivalent
SITCOutdoor projectors/spot light 6W, IP65, IK 06, - Die-cast aluminium housing, Pre-treated before powder coating ensuring high corrosion resistance , The fixture should be plug and play design for simplifying installation, protecting the system from water infiltration, and ensuring long-lasting performance, anti-corrosion solution, and powder coating with a thickness of 80-100 microns minimum for effective corrosion resistance at coastal area. Fixture color RAL to match with landscape color. Single cable entry, - Stainless steel fasteners in grade 304 with zinc flake coating (ZFC) - Durable silicone rubber gasket - High-efficiency PMMA lens, - Clear toughened glass, - Integral control gear, Material Aluminium Light source 1 LED, Lumen 356 - 374 lm, Efficacy 59 - 62 lm/W, Driver option Integral control gear, Driver Constant current (CC), nput voltage 220-240 V 50/60 Hz, Optic M, Optic value 24°, CCT=3000K CRI=80, On/Off driver, Operating temperature -20 °C to 50 °C Maximum Fixture dimensions Dia:105mm, H:185mm . Approved Make: SIMES/LIGMAN/MEYER or equivalent
INTERNAL LIGHT
Supply of Decorative Chandelier - As per Architect Choice
MUSEUM LIGHT(INTERNAL)
FIRE FIGHTING
(A)Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following,complete in all respects, as required : (Jockey Pump). (B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (C)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure,horizontal foot mounted type with Class-'F' insulation,conforming to IS : 325. (D)M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required . (E)Suitable cement concrete foundation duly plasteredand with anti vibration pads. 180 lpm at 70 m Head (Make- Kirloskar, Mather & Platt)
CONTROL PANEL
CABLING & WIRING Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supply, laying, testing & commissioning of FRLS, PVC outer sheath, steel armoured, aluminium / copper conductor, 1100 Volt Grade power cables with gland etc. The cable shall be laid in tray / hume pipe / in trenches / on walls / floors etc as required. Cables laid out doors shall include the price of earth excavation providing brick and sand protection, refilling and compacting the earth.(Make- Polycab, Mescab) 3.5C x 50 sq.mm YFY for main pump
10C x 1.5 sq.mm YFY for Diesel Pump
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on pump header. (Make- H. GURU / FIEBIG / PRICOL )
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.(Make- INDFOS / SWITZER / DENFOS)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 300 mm dia (wall thickness 7.1 mm) (Make-TATA,JINDAL)
250 mm dia (wall thickness 6.3 mm)
200 mm dia (wall thickness 6.3 mm)
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :(Make-H.SARKAR / KARTAR / KOLEY) 200mm dia
150mm dia
80mm dia
65mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. Size 150 mm NB (Make-H.SARKAR / KARTAR / KOLEY)
Size 65 mm NB
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : (Make-NEWAGE / FIRESHIELD/ SAFEX ) 4 way - 150 mm dia M.S. Pipe
Supply & installation of 150NB GM / SS Fire Brigade Draw out connection with necessary foot valve with strainer. (Make-NEWAGE / FIRESHIELD/ SAFEX )
HYDRANT SYSTEM. Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports,anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (Make-TATA,JINDAL) 150 mm. Dia
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts,gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports,anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (Make-TATA,JINDAL) 100 mm. Dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia (Make-TATA,JINDAL)
80 mm dia
25 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm dia(Make-H.SARKAR / KARTAR / KOLEY)
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :150 mm dia(Make-H.SARKAR / KARTAR / KOLEY)
80 mm dia
Supply and installation of Globe Valves in Bronze Construction to IS: 778 with screwed ends 25 NB size (Make-ITAP / LEADER / ZOLOTO)
Supply, installation of automatic 25 NB Air Release Valve (Make-ITAP / LEADER / ZOLOTO)
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel,ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel (Make-NEWAGE / FIRESHIELD/ SAFEX )
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304) (Make-NEWAGE / FIRESHIELD/ SAFEX )
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304) (Make-NEWAGE / FIRESHIELD/ SAFEX )
Supply & installation of hose box, fabricated from 16 SWG CRCA sheet, double door with lockable arrangements to accommodate 2 RRL hose of 15 m length and one branch pipe painted white inside and red outside with one key. (750x600x250 mm). (Make-NEWAGE / FIRESHIELD/ SAFEX )
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.(Make-NEWAGE / FIRESHIELD/ SAFEX ) 30m
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 3 way - 150 mm dia M.S. Pipe (Make-NEWAGE / FIRESHIELD/ SAFEX )
Supply & installation of dial type Pressure Gauge of suitable pressure range, fitted with dampner arrangement and isolation ball valve as shown in respective drawing. The diameter of dial shall be 150 mm preferably filled up with glyserine. All other necessary fittings to be supplied to erect the gauge on pump header. (Make- H. GURU / FIEBIG / PRICOL )
Supply and installation of 300NB Hume Pipe of NP3 class for underground pipes at road crossings.(Make- REPUTED )
FIRE DETECTION, ALARM SYSTEM AND CCTV
Supply, Installation, Testing & Commissioning of 5MP, STQC Compatible, Full HD, 1/2.8 type CMOS image sensor, fixed lens 2.8mm, H.265 / H.264 & MJPEG, dual stream encoding, 30fps@1080P (1920 ×1080), Max IR LEDs length 30m,Voice Enabled, IP67, IK10 rated, Operating Temp (-)30°C ~ 60°C & Humidity 95% (non-condensing) Vandal Resistant, UL, FCC, CE & ULc approved, Dome Camera complete with all accessories required for mounting on wall or ceiling as mentioned in specs Fixed Dome Camera.
Supply, Installation, Testing & Commissioning of 5MP, STQC Compatible, Full HD, 1/2.8 type CMOS image sensor, fixed lens 2.8mm, H.265 / H.264 & MJPEG dual stream encoding, Max. IR LEDs length 30m,Voice Enabled, IP67 rated, 30fps@1080P (1920 ×1080), Support ICR for day time and night time operation, Operating Temp (-)30°C ~ 60°C & Humidity 95% (non-condensing),UL, FCC, CE & ULc approved, All accessories required for mounting on wall or ceiling as mentioned in specs Fixed Lens Bullet Camera.
Supply, Installation, Testing & Commissioning of 5MP ANPR Camera, STQC Compatible, 1/2.8" - 1/1.8" progressive Scan CMOS,H.2664/H.265/MJPEG compression, IP67 rating for dust & water resistance & IK10 rating for vandal resistance
Supply, Installation, Testing & Commissioning of 5MP, Full HD, 1/2.8 type CMOS image sensor, STQC Compatible, H.265 / H.264 & MJPEG triple-stream encoding,30x optical zoom, 25/30fps@2688×1520/(2650x1440), IR distance up to 150 m ,IP66 rated, with audio Indoor PTZ Camera.
SITC of NVR (HD, OnVIF), 100 Mbps Port, recording capability of 80Mbps, with capacity of 16TB recording sapce divided into 8 SATA interfaces or more / as per OEM recommendation (to be supplied with HDD), ANR, H.265/H.265+/H.264+/H.264 Compressing with 445 × 400 × 75 mm ( 17.5"× 15.7" × 3.0") dimension to be supplied with client software.
SITC Hard Disk Drive with 10 TB storage
SITC of Workstation with monitor for monitoring
Supply , Laying , Testing & Commissioning of 85” LED Display with necessary connectors with HDMI Ports for 24X7 operation, inter linking cords etc. complete as required
SITC of 42U Network Rack for placing CCTV NVRs & Main Switch
SITC of 15U Network Rack for floor
SITC of 9U Network Rack for floor
SITC of Layer 3 switches with high performance switching, high density port configuration, advanced security features, optics support : QSFP28 & SFP28,
SITC of Semi Managed/Full Managed, Layer2, QoS, 24*1000 Mbps + 2 SFT/T , All port support PoE, full switches PoE rating min. 200W
SITC of Un-managed Non-POE 24 Port with 2 SFP ports
SITC of Media Convertor for connecting CCTVs
SITC of LIU and other accessories
SITC of LIU and other accessories
SITC of Pigtails
SITC of LC-LC Connector
SITC of 1 mtr Patch Cord
SITC of 3 mtr Patch Cord
SITC of 24 port Patch Panel
SITC of RJ-45 UTP Cat-6 Socket
SITC of IO Module
SITC of MDF Box with Krone 250 Pair
SITC of 24 port FXS Gateway for analogue intercom connectivity
SITC of high speed wifi access points
Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required Telephone socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required TV Antenna socket outlet
Supply, installation, testing and commissioning of Smart Card Reader with a read range of 2-3 inch as per specifications , complete with mounting box / arrangenet as reqd.
Supply, installation, testing and commissioning of 13.5 MHz Smart Cards as per specifications .
Supply, installation, testing and commissioning of Stainless Steel Push Buttons, complete with mounting box / arrangenet as reqd.
Supply, installation, testing and commissioning of Single Leaf Electromagnetic Locks with 600 lbs holding force as per specifications with all accessories for mounting on the doors etc complete as reqd.
Supply, installation, testing and commissioning of Magnetic Contact as per specifications with all accessories for mounting on the doors etc complete as reqd.
Supply, installation, testing and commissioning of Emergency Door Release Switches as per specifications with all accessories for mounting on the doors etc complete as reqd.
A WLD2400 Main Panel designed to protect facilities from damaging water leaks. It combines superior leak detection technology with a user-friendly interface to establish a reliable leak detection system.
WLD Sensor Cable:WLD Sensor Cable (25m)
Hooter Cum strobe
Supply, installation, testing, commissioning of IP54, 4.5 m wide automatic Boom Barrier with 230 V AC OR 24V DC for actuator, for operation with 1 phase 230 V power supply , 100% duty cycle, Open/Close time 2 to 4 second with dome shaped flashing light, LED strip inside the boom on one side, luminous cord cable, single channel loop detector, photo beam sensor for accident prevention, inbuilt anti collision & crushing feature, IP-66 protection, with Straight aluminum boom of minimum size 100 mm x 50 mm & a set of entry exit push buttons for manual opening and closing of barrier for visitor vehicles etc. complete as required as per specifications & at site of work. ( NorthWest Side main entry , 2 Entry + 2 Exit )
Supply & fixing of padestal with MS PU coated Pole to mount TAG reader with civil work, as approved by Architect.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150mm Width X 50mm depth X 1.6mm thickness
225mm Width X 50mm depth X 1.6mm thickness
300mm Width X 50mm depth X 1.6mm thickness
Supply & fixing following size Under floor pregalvanized junction box with knock outs suitable for metal raceway entry in all the four sides. The box is suitable for screed floors with powder coated trap and frame suitable for tile flooring with 10mm recess.150mm x 150mm x 50-70mm height adjustable Junction Box
Supplying and fixing of "25mm dia" medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required
Supplying & drawing of UTP 4pair CAT 6 LAN Cable in the exixting surface/recessed steel/ PVC conduit as required ( 1run of cable)
SITC of Fiber Optic Cable
SITC of 2C, 1.5 sq mm Cable for AC & accessories
Supplying & drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface/recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair 2-core, 1.5 sqmm
SITC of 8 core 1 Sq mm armoured and shielded copper cable with connection and required accessories at both ends
SITC of 4 core 1 Sq mm armoured and shielded copper cable with connection and required accessories at both ends
SITC of 3 Core, 1sqmm, 230V, 50Hz, 1 Ph AC
SITC of 1.1 KV grade FRLS 3C 2.5 Sq. mm YWY cables
Supplying & drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the exixting surface/recessed steel/PVC conduit as required.
PORTABLE EXTINGUISHERS
Supply & fixing of 6 Kg dry power extinguisher consisting of welded MS cylindrical body with discharge valve, nozzle & CO2 cartage and hanging arrangement complete conforming to IS:2171 (Make-MINIMAX / FIRESHIELD/ SAFEX )
Supply & fixing of 9 Litre Water type CO2 (ISI marked) extinguisher including all accessories with wall bracket & raw plug conforming to IS:940 (Make-MINIMAX / FIRESHIELD/ SAFEX )
Providing & fixing 9 Litre Foam type (ISI marked) extinguisher including all accessories with wall bracket & raw plug confirming to IS:10204 (Make-MINIMAX / FIRESHIELD/ SAFEX )
Supply & fixing of 4.5 Kg carbon-di-oxide fire extinguishers (ISI Marked) consisting of welded MS cylindrical body, squeeze, lever discharge valve, fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, finished externally with red enamel paint and fixed to wall with brackets with rawlplug/ dash fastners complete with internal charge conforming to IS:2878. (Make-MINIMAX / FIRESHIELD/ SAFEX )
SIGNAGES
Supply and installation in position the "FIRE EXIT" Sign with luminicent colour having size 300 x 100 mm.(Make-MINIMAX / FIRESHIELD/ SAFEX )
Supply and fixing in position the signages " FIRE ORDER" contain the following matter on 3 mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of size 1200 x 1000 mm.
ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION.
EVACUATE THE OCCUPANTS BY USING FIRE EXIT AND EMERGENCY EXITS ONLY AND ASSEMBLE AT ASSEMBLY POINTS.
BE CALM AND DO NOT GET PANIC, WALK DO NOT RUN
IF POSSIBLE TRY TO EXTINGUISH FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.(Make-MINIMAX / FIRESHIELD/ SAFEX )
Supply and fixing signage with printed " IN CASE OF FIRE, DO NOT USE LIFT. USE STAIRS ONLY" OF 1.5 cm height letters in red with white background. The size of the board shall be 300 x 250 mm and shaall be fixed at the height of 2 mtrs.from finished floor near Manual Call Point.(Make-MINIMAX / FIRESHIELD/ SAFEX )
PA SYSTEM
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.6-ZONE VOICE ALARM CONTROLLER
Supply, erection, testing & commissioning of 6Watt Ceiling mounted Speakers with all accessories,6W CEILING MOUNTED SPEAKER
Supply, erection, testing & commissioning of 10Watt Wall mounted Speakers with all accessories,10W WALL MOUNTED SPEAKER
Supplying, installation, testing & commissioning of Voice Command Keypad 6 zone, with microphone assembly complete as required,6-ZONE VOICE COMMAND KEYPAD
Supplying, installation, testing & commissioning of 200W Digital Audio Amplifier,200W AMPLIFIER
Supplying, installation, testing & commissioning of 250W Digital Audio Amplifier,250W AMPLIFIER
Supplying, installation, testing & commissioning of 350W Digital Audio Amplifier,350W AMPLIFIER
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.CABLE TRAY 150mm Width X 50mm depth X 1.6mm thickness
225mm Width X 50mm depth X 1.6mm thickness
300mm Width X 50mm depth X 1.6mm thickness
Supply & fixing following size Under floor pregalvanized junction box with knock outs suitable for metal raceway entry in all the four sides. The box is suitable for screed floors with powder coated trap and frame suitable for tile flooring with 10mm recess.JUNCTION BOX 150mm x 150mm x 50-70mm height adjustable Junction Box
Supplying and fixing of "25mm dia" medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required,25DIA PVC CONDUIT
SITC of 2C, 1.5 sq mm Cable for AC & accessories,2CX1.5sqmm CABLE
Supplying & drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface/recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair 2-core, 1.5 sqmm,2CX1.5sqmm CABLE
SITC of 8 core 1 Sq mm armoured and shielded copper cable with connection and required accessories at both ends,8C Cable
SITC of 4 core 1 Sq mm armoured and shielded copper cable with connection and required accessories at both ends,4C Cable
SITC of 3 Core, 1sqmm, 230V, 50Hz, 1 Ph AC,3C Cable
SITC of 1.1 KV grade FRLS 3C 2.5 Sq. mm YWY cables ,3Cx2.5 CABLE
Supplying & drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the exixting surface/recessed steel/PVC conduit as required.RG-6 CABLE
Supplying and laying of 160 dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench,160DIA HDPE PIPE
Supplying and laying of 120 dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench,120DIA HDPE PIPE
Supplying and laying of 63 dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench,63DIA HDPE PIPE
Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual seperate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50HzAC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70, ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building). For Cooling or Heating or Both 6HP
6HP FOR TFA
8HP FOR TFA
Supply, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted hight ductable type Indoor unit eqipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V + 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)High Static Ductable units (minimum 78 pascal external static pressure)6.6 tr
Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /InternationaI Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling onlyHI - Wall Units Split Unit1.0 TR with 5 Star BEE Rating
1.5 TR with 5 Star BEE Rating
2.0 TR with 5 Star BEE Rating
Supply, Installation, Testing & Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs & IDUsIndoor Units
Outdoor Multi Joint
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :41.3mm dia(OD)(Harddrawn) with tube thickness 1.62mm with 19mm thick insulation
38.1mm dia(OD)(Harddrawn) with tube thickness 1.62mm with 19mm thick insulation
34.9mm dia(OD)(Harddrawn)with tube thickness 1.62mm with 19mm thick insulation
31.8mm dia(OD)(Harddrawn)with tube thickness 1.62mm with 19mm thick insulation
28.6mm dia(OD)(Harddrawn) with tube thickness 1.2mm with 19mm thick insulation
25.4mm dia(OD)(Harddrawn)with tube thickness 1.2mm with 19mm thick insulation
22.2mm dia(OD)(Harddrawn)with tube thickness 1.2mm with 19mm thick insulation
19.1mm dia(OD)(Harddrawn)with tube thickness 1.2mm with 19mm thick insulation
15.9mm dia(OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
12.7mm dia(OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
9.5mm dia(OD)(Softdrawn)with tube thickness1.2mm with 19mm thick insulation
6.4mm dia(OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
Supply, Installation, Testing and Commissioning of factory built, VRV/VRF operated double skin type Ceilling Suspended AHU made of 25 mm thick panels consisting of pre plasticized G.I casing of thickness 0.8 outside (pre-painted) and 0.6 inside layer with CFC-FREE P.U. insulation of density 45(+5%) kg/m3 factory injected between them by injection moulding machine, complete with blower suitable for 65 mm WG static pressure , coil section with aluminum finned copper tubes( tube thickness not less than 0.5mm, 10 FPI, Copper header with MS adaptar) of 4/6 row deep, filter section with 50 mm thick washable synthetic type air pre (MERV 8) & fine (MERV 14 up to 3 micron particle size) filters, belt driven Aerofoil design backward curved centrifugal Blower package with IE3 IP55 rated Motor BEE 5 Star rated and suitable to operate at 415 ± 10% volts, 50Hz 3 phase, A.C supply & should be compatible with VFD, drain connection, stainless steel (18G) drain pan with PUF insulation, limit switch, view glass, marine light, hinged door, Binder test points at the inlet and outlet of coil, Descaling valve, auto air purge valve at the inlet and outlet of coils, necessary spring type vibration isolation arrangement, canvas connection with thermal break profile etc., complete as per specifications and of followings capacities. 6300 CFM/18 TR
5500 CFM/15.7 TR
Ductable/Ceiling Suspended Type TFA Unit
Supply of Treated fresh air Units with VRF Coil With consideration of EC fan/ prefilter + finefilter(EU-5) + HEPA filter(H-14) suitable for operation on 220 - 240V, 50 Hz, single phase AC supply complete with cooling coil, electronic expansion valve, multi speed fan motors, dynamically balanced blowers, built in drain pump, synthetic washable plasma media filter including insulation with Cordred remote control oeration capable of varying the air flow automatically as per inside load condition with inverter technology complete as required. Treated Fresh Air Units shall be connected with VRV/VRF System.4.0 TR Treated Fresh Air unit
6.4 TR Treated Fresh Air unit
8 TR Treated Fresh Air unit
Supply of Main Inteligent Central Controller Suitable ror above all Indoor units to Operate, Monitor, On/Off, Temperature Setting etc including all acessories. The system shall be compatible for operating through PC. The System Should Also Have The Software For Necessary For Lenant Billing As Per Consumtion of Idu.
Cordless/Corded Self Diagnostic Type Remote Controllers
Supply of Cordless Remote for Cassatte/ HI - WALL Type Unit
Supply of Corded Remote for Duct Type Unit
Connection Kit Supply of Copper Pipe Connection Kit joint to the veriable outdoor unit with insulation.
AHU Connection Kit Supply, Installation, Testing & Comissioning of AHU Kit including control box & expansion valve kit to connect the AHU with the VRV/VRF ODU
GI Ducting Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Make:SAIL/TATA/JINDAL/ESSARThickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 0.91 mm sheet
Thickness 1.22 mm sheet
DUCT Thermal InsulationSupply and fixing of following thickness Alu foil pasted XLPE Sheet of density 33±10kg/m³ or closed cell nitrile sheet of density 40~60Kg/m³ class (O) insulationon after applying two coats cold setting adhesive.The joint shall sealed with self adhesive 50 x 3 nitrile rubber tape insulation complete as per specification and as Required.19MM
CANVAS CONNECTION Supply Installation testing comissioning of Fire retardent Canvas connection for Air conditioning and ventilation equipment .
Supply Installation, testing and commissioning of rain protection louver for fresh air or exhaust air complete with extruded aluminium constuction with powder coated finish complete in all respect as per drawings.
Supply Installation, testing and commissioning of TOILET EXHAUST GRILL with coller damper complete with extruded aluminium constuction with powder coated finish complete in all respect as per drawings.
Supply Installation, testing and commissioning of Duct/FA Damper of of 16G GI constuction and complete in all respect as per drawings.
Supply ,Fixing,testing and commssiooning of MOTORIZED fire dampers in supply air duct /main branch and reurn air path as and where required with control wiring. The damper shall be motorised and spring return actuator to close the damper in the event of power failure automatically and poen the same incsae of power being restored. The damper shall also be closed in the event of fire signal completeas required and as per specifications and atleast 90 minutes rating as per UL555/1995 TESTED BY CBRI.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. Make: RAVISTER/AIR MASTER/AIR FLOW/Caryaire/Cosmos /Dynacraft/System Air /Mapro /Tristar
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.Make: RAVISTER/AIR MASTER/AIR FLOW/Caryaire/Cosmos /Dynacraft/System Air /Mapro /Tristar
Supplying & fixing of powder coated extruded aluminium Exhaust/Return air Grills with aluminium volume control dampers as per specifications.Make: RAVISTER/AIR MASTER/AIR FLOW/Caryaire/Cosmos /Dynacraft/System Air /Mapro /Tristar
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.Make: RAVISTER/AIR MASTER/AIR FLOW/Caryaire/Cosmos /Dynacraft/System Air /Mapro /Tristar
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.Make: RAVISTER/AIR MASTER/AIR FLOW/Caryaire/Cosmos /Dynacraft/System Air /Mapro /Tristar
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.19 mm Make:Aeroflex /Armacell / A flex / K Flex
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications. Armacell - Armasound / A Flex / K Flex
Providing and fixing UPVC pipes with fittings with solvent cement joints including cuttings the pipes to correct length providing and fixing with hot dipped galvanised brackets, with GI U bolts and fixing the same with anchor fasteners, making good the same, testing, including providing an fixing with all types of CORZON fittings all complete.Make: Supreme / Astral / Ashirbad25 MM DIA (O.D)
32 MM DIA (O.D)
50 MM DIA (O.D)
Supply of Rrefrigerant for the V R F System if needed additionally
Supply Installation, Testing and commissioning of Copper fittings (Refnet / Y-joints ) for networking the refrigerant pipelines Make: Daikin / Carrier / Mitshubishi
Supply, Installation, Testing and Commissioning of powder coated extruded aluminium Exhaust air louvers.Make:RAVISTER/AIR MASTER/AIR FLOW/Caryaire/Cosmos /Dynacraft/System Air /Mapro /Tristar
Supply, Installation, Testing and Commissioning of Ceiling Hung Supply Air Axial flow fans of 15 mm WG static pressure complete with GSS casing , aluminium alloy impellers, directly driven by TEFC induction motor suitable for 3 Phase 50 Hz 415 V ± 10 %, 1400 RPM, supporting frame, backdraft damper, louvers, weld mesh inlet guard, TP isolator with MS enclosure box as required etc. as per drawings and specifications.9600 CFM FOR EXHAUST, 20 mmWG SP
8700 CFM FOR EXHAUST, 20 mmWG SP
6700 CFM FOR EXHAUST, 20 mmWG SP
5700 CFM FOR EXHAUST, 20 mmWG SP
Supply,installation,testing and commissioning of circular / rectengular type Inline type cabinet fans complete with mounting arrangement, power and control wiring etc. of below capacity.The motor shall be suitable for 240V±5%, 1Ph. AC power supply.1500 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
1300 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
1000 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
900 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
800 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
700 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
650 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
600 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
200 CFM, 15 mmwc SP With Noise level 60DB max at 1 Mtr distance
Supply,installation,testing and commissioning of propeller type fans complete with mounting arrangement, power and control wiring etc. of below capacity.The motor shall be suitable for 240V±5%, 1Ph. AC power supply.100 CFM
Supply, installation, testing and commissioning of ELECTROSTATIC PRECIPITATION BASED DRY TYPE SCRUBBER UNIT for Kitchen exhaust. The unit shall be made of 1.0 mm thick galvanized sheet, High bake epoxy powder coated, washable aluminum mesh pre-filter, Stainless steel spiked ionizers to create high voltage DC field. Unit shall have aluminum collector plates with an average efficiency of 90-95% in single pass, collector cell should be removable for cleaning. The unit shall be integrated & connected with Kitchen Exhaust fan including all necessary accessories to complete the installation. Air moving capacities shall be as follows and also unit should be Outdoor application type .7500 CFM DRY SCRUBBER
Supply, Installation, Testing and Commissioning of DIDW (Double Inlet, Double Width) type centrifugal fan of 65 mm WG static pressure complete with GSS casing , aluminium alloy impellers, directly driven by TEFC induction motor suitable for 3 Phase 50 Hz 415 V ± 10 %, 480-1450 RPM, complete with all accessories as per drawing & specifications. 6700 CFM FOR KITCHEN FRESH AIR
Supplying and fixing IP 65 rated TP sheet steel enclosure on surface/ recess along with 63 A 415 V 30mA 4 Pole RCCB complete with connections, testing and commissioning etc. as required.
63A, 300mA, 4P RCCB Enclosure
40A, 300mA, 4P RCCB Enclosure
32A, 300mA, 4P RCCB Enclosure
25A, 300mA, 4P RCCB Enclosure
20A, 300mA, 4P RCCB Enclosure
Supply, Installation & Testing of Starter Panel for Tube Axial Fan for pressurization as follows:DOL Starter|3kW
Wiring for circuit alongwith earth wire with the following sizes of FRLS PVC PVC insulated 1100 V grade stranded copper conductor wire in surface/ recessed medium class 20/25mm(O/D)(1.5mm thick) ISI Marked rigid PVC conduit (including 20/25mm PVC Bends,Coupler,20/25mm iron staples/saddles/screws,20mm PVC 4way junction box) including cost of cutting & filling chases as required. IS Code of Wire: IS:694-2010(Part 4) : PVC insulated cables. Material Make List : Wire Make: POLYCAB/ FINOLEX/HAVELLS’ or Equivalent.3C X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Split Indoor)
3C X 4 sq. mm + 1 X 2.5 sq. mm earth wire (Ductable IDU/TFA)
4C X 06 sq. mm + 2 X 6 sq. mm earth wire (upto 12HP)
4C X 10 sq. mm + 2 X 6 sq. mm earth wire (upto 20HP)
4C X 06 sq. mm + 2 X 6 sq. mm earth wire (AHU 7.0-8.0kW)
4C X 04 sq. mm + 2 X 6 sq. mm earth wire (AHU 5.0-7.0kW)
4C X 2.5 sq. mm + 2 X 6 sq. mm earth wire (AHU upto 5.0kW)
2C X 1.5 sq. mm (for communication btw indoor & outdoor)
Supplying and making end termination with brass compression gland and aluminium/CU lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium /CU conductor cable of 1.1 KV grade as required.3C x 2.5 sq.mm. arm. CU. cable
3C x 4 sq.mm. arm. CU. cable
4C x 2.5 sq.mm. arm. CU. cable
4C x 4 sq.mm. arm. CU. cable
4C x 6 sq.mm. arm. CU. cable
4C x 10 sq.mm. arm. CU. cable
2C x 1.5 sq.mm. arm. CU. cable
Supply, erection,testing, commissioning of AHU Control Starter Panels with VFD control & bypass system. Rate includes for necessary control cable with earthing. Apprx average length is 10m for the cable. The panels should be equipped with fire interlock arrangement.
STARTER PANEL: 8kW
STARTER PANEL: 7.5kW
STARTER PANEL: 7kW
STARTER PANEL: 5kW
STARTER PANEL: 4.5kW (TFA)
STARTER PANEL: 3kW
MS Structure for Catwalk of IDU or ODU placement
LANDSCAPE WORK
SOFTSCAPE PORTION Supplying and stacking of good earth (adequate for horticulture work) at site including royalty (earth measured in stack will be reduced by 20% for payment)
Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
Supplying and Planting of different plant / trees (Supplying well grown plants bushy and healthy, minimum height as specified i.e. exposed height including all leads & lift, carriage, handling, manuring, applying presticide and fertilizer etc. with minimum six months maintenance after planting. Acacia auriculiformis - Auri Tree (10')
Anacardium occidentale - Cashew Tree (4'-5')
Albizia lebbeck - Siris Tree (10')
Areca catechu - Betel Palm (7'-8')
Bruguiera gymnorrhiza - Orange Mangrove (4')
Cassia fistula - Golden Shower (4'-5')
Cassia siamea - Cassod Tree (4'-5')
Cassia senna - Indian Senna (4'-5')
Calliandra haematocephala - Red Powder Puff (1'-2')
Clerodendrum infortunatum - Bhant (4"-6")
Cuphea hyssopifolia 'pink'- Pink Barleria (4"-6")
Cocus nucifera-Coconut (10')
Ficus religiosa- Peepal Tree (10'-15')
Hibiscus rosa sinensis- China rose (1'-2')
Plumeria alba- Frangipani (6'-8')
Azadirachta indica - Neem (10')
IRRIGATION
Providing PC INLINE Drip 16mm 30- 50 CM 2.3 LPH, 4 Bar Pressure Rating, 1.2mm Thickness together with all required accessories.Metzer, Smartflow imported with 17mm Brown Rain Bird Special Barb fittings (Brown Color, DUAL LAYERED)
9" Long Lateral Hold Stake - PVC STAPLE.
Air relief valve 1/2" Inside Valve Box
Disc Filter 18 m3/hr for Drip Irrigation.
12" Valve Box with cover for Disc filter PVBM series
Flush Valve 40mm
Take Off Connection (Clamp Saddle + PVC Riser + Threaded Tee, 17mm elbow, Tee, Barb Connector etc Brown Coloured)
Sprinklers and Accessories Providing of Gear driven Pop-up Sprinkler (5004) 4" (4" Pop Up hight from Bottom to Centre of Discharging Nozzle) from (9.0 to 14.0 Mtr Radius) with Check Valve, Inbuilt pressure regulator & on off feature from top, Slip Clutch Mechanism complete with required nozzle Make : Rain Bird
Providing of Swing Joint 3/4" with & Nitrile Rubber Gasket Make: RainBird
Providing of SPRAY driven Pop-up Sprinkler (4" Pop Up hight from Bottom to Centre of Discharging Nozzle) from (2.0 to 8.0 Mtr Radius) with Check Valve, Inbuilt pressure regulator & on off feature from top, Slip Clutch Mechanism complete with required nozzle Make : Rain Bird
Providing of Swing Joint 1/2" with & Nitrile Rubber Gasket Make: RainBird
PP Service Saddle 3/4", 50mm/ 40mm
PP Service Saddle 1/2", 50mm/ 40mm
3/4" Brass Quick coupling valve
3/4" Brass Quick coupling key
Brass Swivel Hose Elbow 3/4" X 3/4"
PP Saddle Tee 63mm/50mm X 3/4" witth ASTM Pipe SOS with Special Brass fitting
15 mt Spot Hose with multi Jet Gun Nozzle for Plant Washing & domestic maintainence with 6 different pattern
Pressure Gauze (glycerin filled)
Air Release Valve 1"
Pressure Relief valve 2" with bypass outlet
Automation Unit IVM Sensor
Solenoid Valve (2")
Solenoid Valve (1.5")
Solenoid Valve (1")
PRS Dial for Drip Valve
#2.5 sq mm Copper Conductor Direct Burial Double Core Cable
32mm PVC Conduit Pipe
DBY series water proof wire connector with splices
Rain Sensor
IVM Surge Device
Pumping Unit Monoblock Pump having discharge 3.5 lps at 60 meter head with unit, Base Fittings, and fittings etc. (1 working + 1 standby)
Control Panel for the pump with 24 V Special relay FITTINGS OF L&T SCHNIDER ASSEMBELED with GI POWDER COATED suitable BOX ALL THE FITTINGS & FIXTURE eg: water level guard, single phasing preventer, LED lindicator lights, changeover switch etc. All fixtures will be capable of operating for 2 PUMP OPERATION will be One Panel Box for easy and hassel free operation
Pump Header UPVC pipe with fittings including BRASS Gate valve NRV, Pressure gauge etc complete 2"
UPVC pipe work for underground ceeling SCh 40 pipe with Ciling clamps arrangement 3"
2.5 sqmm FLAT CABLE FOR PUMP CONNECTION. FROM PANEL TO PUMP
Y TYPE Strainer FILTER for suction side 4"
CONSULTANCY
CONSULTANCY FEES = i) Master planning, Campus Design and Consultancy ii) Mandir Architecture Design, Coordination and Consultancy iii) Landscape Planning & Design iv) Specialised Vaastu Consultancy v) Structural Design, Detailing and Consultancy (Including IIT/Instutional vetting) vi) Interior Planning, Design, Acoustics and Decoration Consultancy vii) Facade Engineering, Design & Consultancy viii) Illumination Design and Consultancy ix) PHE Design (Including Fountain design intent) And Consultancy x) Fire Detection & Fire Fighting Design (Including Provitional and Final NOC) xi) Electrical And ELV Design and Consultancy xii) HVAC Design & Consultancy xiii) Security, Vigilance & Control Design & Consultancy xiv) Environmental Graphics and Signage Design. xv) Mandir sculptures and Mural design intent. xvi) Coordination & approval of shop drawings of Stone Work. xvii) Coordination & approval of shop drawings of Shiv Murti Work with concerned vendor. xviii) Periodic supervisoin (Once site visit Monthly) including all. xix) Energy Survey, Drone Survey, and Soil Investigation Report xx) NOC or liasoning with any other authority for sanctioing the entire project from the concerned authority.
Add CGST @9% of total amount to Rs.2893070867.75
Add CGST @9% of total amount to Rs.2893070867.75
Add Construction Cess @1% of total amount to Rs.2893070867.75
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.47 MB
DRAWING.pdf
Tender Documents • 21.79 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.59 MB
2911_FORM.pdf
Tender Documents • 0.16 MB
DBR.pdf
Tender Documents • 16.58 MB
BOQ_2413331.xls
BOQ • 1.87 MB
TECHSPEC.pdf
Tender Documents • 5.32 MB
Special_Terms_and_Condition.pdf
Tender Documents • 1.05 MB
Download all tender documents and submit your bid