| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC aoc | |
| 2 | L2₹7.2 L+₹98,526 (16.0%)Rejected-Finance 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹7.6 L+₹1.4 L (22.8%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹8.0 L+₹1.8 L (29.1%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
3 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I R AND D KOCHI
AGE I R AND D KOCHI, THRIKKAKARA,KAKKANAD, KOCHI 682021
REPAIR MAINTENANCE OF HT LT DISTRIBUTION SYSTEM AT UARF KULAMAVU UNDER AGE I R AND D KOCHI
2023_MES_631419_1
8252E8AGERDK
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KULUMAVU
AS PER TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
Yes
AGE I R AND D KOCHI
₹16,000
Yes
14 May 2025
6 Dec 2023
5 Jan 2024
6 Dec 2023
3 Jan 2024
20 Dec 2023
Amount
M & L for XLPE insulated, armoured, heavy duty electric cable of size 25 Sqmm 4 core with aluminium conductor, 1100 Volts grade, laying in trenches/fixed on wall and pole including taking down old unserviceable one complete all as specified and as directed of following cross-sectional area:
Note (i) Rate include the cost of lugs of proper size, and cable gland. (ii) Necessary Excavation, PCC cover and sand cushioning shall be measured & paid seprately.
Excavation in trenches not exceeding 1.5 mtr deep and 1.5 mtr width as in soft/loose soil complete all as specified.
Returning filling incl leveling watering and well ramming in layer not exceeding 25 cm thick complete all as specified & directed by EIC.
Removal of surface soil to a distance n.exc 50 m and deposited where directed at a level n. exc 1.5 m above the starting point complete all as directed by EIC .
S & L for riddled earth for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete all as directed. ( Note: Punned thickness shall be taken for measurement)
M & L for laying LT cable cover of size 250x150x75mm class LV type 1 flat for protection of cable in trenches complete all as directed by Engineer-in-Charge.
Supply and fix breather for transformer oil conservator tank including filled with silica gel for transformer of ratings 160 KVA complete all as specified and as directed by engineer-in charge
M & L for filtration of transformer oil of different capacity/Rating to remove moisture, sludge, carbon particles and to achieve the dielectric strength / rupturing capacity of oil not less than 50 KV/ minute with 2.5 mm gap and topping up of oil to the required level of transformer indicator level all as specified and directed by engineer-in-Charge. Note: Topping up of transformer oil shall be measured and paid separately (2) Contractor has to make his own arrangement for oil filtration plant.
M & L for topping up/ change oil for transformer of 11KV/433 Volt of different capacity / HT oil switch of 11 KV of different capacity of any rating of dielectric strength /repturing capacity of oil not less than 50 KV ( tested at site with testing kit with 2.5 mm gap ) and test the the dielectric strength of transformer oil before and after the topping up and make oil to the required level of transformer indicator level all as specified and directed by EIC. Note:1) The transformer oil container shall be ISI marked and brought at site in sealed container only. 2).The M & L for necessary T & P for collection of transformer oil samples , testing kit and filtration plant.
Supply, Install, Testing and commissioning LT feeder pillar (in replacement of outdoor Type) suitable size, CPRI Approved factory made, Double door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3.15mm thick CRCA steel sheet, weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items :-
a) 4 Nos Aluminium Busbars of high conductivity (b) 3 Nos for phase (R,Y,B) rating 200 amp and 1No for neutral rating 200 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set (c) Manular chnageover 160A- 1 No (d) MCCB 4P 160 Amps 25 KA 415 V 50 Hz – 1 No (I/C)
M&L in repiars 4 pole, MCCB, 630A, adjustable thermal magnetic , 50KA breaking capacity all as specified and as directed by engg-in-charge. Make: Havells/L&T/Legrand
S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 25 KA. Make: legrand/Havells/L&T all as specified and as directed.
S & F in replacement of MCCB 4 Pole 400 Amps 415V 36 KA. Make: legrand/Havells/L&T all as specified and as directed.
S & F in replacement of MCB TPN 63 Amp, 4 Pole, 10 KA'C' Curve Make: legrand/Havells/L&T all as specified and as directed.
S & F in replacement of MCB DP 32-40 Amp, 'C' Curve Make: legrand/Havells/L&T all as specified and as directed.
S & F in replacement of MCB SP 6 to 32 Amp, 'C' Curve Make: legrand/Havells/L&T all as specified and as directed.
M & L for cutting the tree branches at a distance not exceeding 2.0 Mtrs way from roof top of E/M Installation of G+0 Building of tree branch size up to 50 mm dia as directed and deposited the removing branches at a distance not exceeding 100 Mtrs from Road /Path. Note: Branch cutting around 2.0 Mtrs area to a 3 Nos street light pole is considered as one Job.
M & L for in replacement of galvanised iron strip 32 x 6 mm buried in ground with saddles and fixing screws etc for roof conductors and down conductors including removing and replacement of deteriorated SS bolts, nuts and washers as required at site etc in the existing GI strip of any size from the starting point to upto the end connected points all as specified and directed by Engr-in-Charge.
Dismantling HT/ LT stay assembly complete including MS clamps with bolts, nuts & washers etc along with necessary excavation and earth work, demolition of cement concrete and removing from thr site necessary excavation & earth work complete all as specified and directed.
M&L for stay assembly complete with accessories such as mild steel glavanised flat iron stay clamp, 7/3.15 mild steel galvanised stay strand/wire, one loo[p type porcelain vitreous insulator (white , brown or green) overall dimensions 65X90 mm & clearing hole 16 mm, stay grips, mild steel galvanised stay bow, thimbles, 16 mm dia diameter of stay rod shown in electrical plate No 1 of MES SSR Part- I complete all as specified and as directed. (Note : Excavation & earthwork, cement concrete measured and paid separately relevant items of this schedule).
Dismantling cross arms, MS channel or angle sections etc. complete and unserviceable removing from the site complete all as directed by Engr-in-Charge.
M & L cross arms, bracings, support clamps and back plates fabricated from structural steel section including nut bolts washer, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including two coats of aluminium paint over a coat of read oxide zinc chrome primer including preparation of surfaces complete all as specified and as directed.
M&L in repairs GOD, triple pole , mechanically operated, 11 KV, mounted on insulator and steel frame, with operating mechanism worked from ground level for a current rating up to 200A all as specified and ad directed by Engg in charge.
M&L in repairs to lightning arrestors expulsion type complete with all fittings, transmission class, with discharge capacity 65 Kilo Amps all as specified and as directed.
Supply, Install, Testing and commissioning LT feeder pillar (in replacement of outdoor Type) suitable size, CPRI Approved factory made, Single door, Cubical type, Compartmentalized design, back door, openable, fabricated out of 3.15mm thick CRCA steel sheet, weather / dust / vermin proof, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one no lock with duplicate key duly painted with powder coated paint having danger notice boards and earthing terminals on both sides and including providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, Spreader terminal set, control wiring, panel to be mounted on cable trench if required with base channels as required complete in all respect all as specified & directed by Engineer-in-charge including comprising of following items :-
a) 4 Nos Aluminium Busbars of high conductivity (b) 3 Nos for phase (R,Y,B) rating 300 amp and 1No for neutral rating 300 Amp, Mounted on DMC support with heat shrink sleeve - 1 Set (c) MCCB 4P 160 Amps 25 KA 415 V 50 Hz – 1 No (I/C) (d) MCCB 4P 63 Amps 16/18 KA 415 v 50 Hz - 2 No (e) MCB DP 32 Amps 10 KA 415 v 50 Hz - 4 Nos
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron strip 32x6 mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm GI tubing light grade and necessary fittings for protection of GI strip including laying of charcoal , dust and common slat , PCC 1:2: 4 type B 1 using 320 mm graded aggregate with earth piot with 40 X 40 X 6.0 mm MS angle iron frame RCC cover 40 mm thick (1:2: 4) type C1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75 mm C/C both way with MS handle 20 mm dia plastering 15 mm thick CM ( 1: 6) internally and up to 150 mm below ground level externally . PGI funel with wire mesh 20 mm dia GI pipe for watering complete all as shown on electrical plate No : 03 of SSR part -I 2009 and connected to earth test point including testing completed all specified and directed.
M&L for road cutting /removing the hard Standing/Cutting floor inside the Substation /E/M Installations / Path for laying of cables of any size including making good disturbed surfaces using cement concrete 1:2:4 using 20mm graded stone aggregate complete all as specified. The item shall include cutting of road, and necessary PCC for making good all as specified and directed by Engg in charge.
M&L for load line vertical MCCB DB, 4 Way, Double door with 125 A MCCB incomer and three/single phase oout going. The DB should be fitted with suitably rated bus bar, neutral links, blanking plates etc. Make : Havells/L&T/Legrand
M&L for medium grade GI pipe 40mm dia for cable protection all as specified and directed by engg in charge.Make: Jindal/ tata etc
WELTRONENGINEERINGSERVICES
M/s.Rejoy Constructions
ELSOL ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .