Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹19.6 L+₹3.4 L (21.0%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹20.3 L+₹4.0 L (24.8%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | Not Admitted-PreQual/Technical | - | Not Admitted-PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-PreQual/Technical | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/s Murari Lal Singhal L3 | M/s Ramesh Kumar Bansal L1 | JAI BABA CONSTRUCTION COMPANY L2 |
|---|---|---|---|---|---|---|
| 1.00 | "Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phases input three phase output. Online double conversion VFI-SS-111 technology, with sinusoidal wave
form, architecture (standalone of distributed parallel up to 8 units), having input characteristics i.e. input voltage (380v, 400v, 415v, 3Ph+N+PE), input frequency (45 -65 Hz), input voltage range (Ph - Ph) : (half load 208v -467v/ full load 312v - 467v), total harmonic distortion of input current < 3% (at full linear load), compatibility with diesel generators configurable for synchronization between the input and output frequencies even for high frequency variations, input power factor > 0.99, having output characteristics i.e. output voltage (380v, 400v, 415v, 3Ph+N (adjustable from front panel), efficiency up to 96%, efficiency in ECO mode up to 98.5%, output frequency (nominal) 50 /60 Hz 0.01% free run (adjustable from front panel), crest factor 3 : 1, total harmonic distortion of output voltage < 2 % (at full linear load), output power factor 0.9, output voltage tolerance ± 1%, built in automatic and maintenance bypass, inbuilt isolation transformer, battery type (VRLA - AGM maintenance free). Communication & management i.e. "
30 KVA (3 phase input & 3 phase output)
For 30 minute backup, min. 24000 VAH | 3 | Each | 5,40,000 ₹16,20,000 | 4,10,000 ₹12,30,000 Lowest | 5,28,390 ₹15,85,170 |
| 2.00 | Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications.
EPABX system consists of 64 nos. extensions, 16 nos of junction & upto 128 nos. of expandable eport, with one operating console, 3 Amp max. current | 1 | Each | 2,25,000 ₹2,25,000 | 3,10,000 ₹3,10,000 | 2,20,150 ₹2,20,150 Lowest |
| 3.00 | Supply, installation, testing and commissioning of telephone instrument as approved by architect (Siemens/ Panasonic/ Tata/ BPL) | 72 | Each | 2,500 ₹1,80,000 | 1,150 ₹82,800 Lowest | 2,200 ₹1,58,400 |
Tender Value
₹37 Cr
EMD Value
₹74 L
Closing Date
18 Nov 2025, 6:00 pmClosed
EE M and H Kota
A-1, Reg. Qtr. UCHC Dadabari Kota (Raj.)
Construction of New District Hospital (100 bed) at Jhalrapatan, Distt. Jhalawar. (Including Internal Electrification Work) (State Head 2025-26)
2025_MEDIC_508733_2
CE M and H Jaipur NIT No. 18/2025-26
Open Tender
Civil Works
Percentage
720 days
Kota
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
EE M and H Kota
₹74 L
Yes
18 Dec 2025
20 Oct 2025
19 Nov 2025
20 Oct 2025
18 Nov 2025
20 Oct 2025
Amount
"Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, having three phases input three phase output. Online double conversion VFI-SS-111 technology, with sinusoidal wave form, architecture (standalone of distributed parallel up to 8 units), having input characteristics i.e. input voltage (380v, 400v, 415v, 3Ph+N+PE), input frequency (45 -65 Hz), input voltage range (Ph - Ph) : (half load 208v -467v/ full load 312v - 467v), total harmonic distortion of input current < 3% (at full linear load), compatibility with diesel generators configurable for synchronization between the input and output frequencies even for high frequency variations, input power factor > 0.99, having output characteristics i.e. output voltage (380v, 400v, 415v, 3Ph+N (adjustable from front panel), efficiency up to 96%, efficiency in ECO mode up to 98.5%, output frequency (nominal) 50 /60 Hz 0.01% free run (adjustable from front panel), crest factor 3 : 1, total harmonic distortion of output voltage < 2 % (at full linear load), output power factor 0.9, output voltage tolerance ± 1%, built in automatic and maintenance bypass, inbuilt isolation transformer, battery type (VRLA - AGM maintenance free). Communication & management i.e. " 30 KVA (3 phase input & 3 phase output) For 30 minute backup, min. 24000 VAH
Supply, installation, testing and commissioning of EPABX system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with ISDN compatible of approved make and labor as required as per specifications. EPABX system consists of 64 nos. extensions, 16 nos of junction & upto 128 nos. of expandable eport, with one operating console, 3 Amp max. current
Supply, installation, testing and commissioning of telephone instrument as approved by architect (Siemens/ Panasonic/ Tata/ BPL)
Bidder Name
Amount
M/s Murari Lal Singhal (GSTN-08AAMFM5354R1ZE) BID ID -3365420
M/s Ramesh Kumar Bansal (GSTN-08ABTPB6020F1ZV) BID ID -3368861
JAI BABA CONSTRUCTION COMPANY (GSTN-08AABFJ2456N1Z3) BID ID -3369804
JAI BABA CONSTRUCTION COMPANY (BID ID -3369804)
M/s Murari Lal Singhal (BID ID -3365420)
JAI BABA CONSTRUCTION COMPANY (BID ID -3369804)
M/s Murari Lal Singhal (BID ID -3365420)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.92 MB
Tendernotice_2.pdf
PDF • 5.33 MB
Tendernotice_3.pdf
PDF • 8.61 MB
Tendernotice_4.pdf
PDF • 0.48 MB
Tendernotice_5.pdf
PDF • 1.59 MB
BOQ_906041.xls
BOQ • 0.72 MB
Bid.pdf
Tender Documents • 12.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .