Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.6 LAccepted-AOC 1 3 183 40 46 PLOT NO 36 VAIKUNTHA SAI NAGAR NEW BAKARAM GANDHI NAGAR HYDERABAD TELANGANA 500080 | HYDERABAD | TELANGANA | 500080 | ₹78.6 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹84.2 L+₹5.6 L (7.14%)Rejected-Finance PLOT NO 112 SHAILI GARDENIA YAPRAL RANGAREDDI TELANGANA 500087 | MEDCHAL MALKAJGIRI | TELANGANA | 500087 | ₹84.2 L+₹5.6 L (7.14%) | L2 | Rejected-Finance Reject |
| 3 | L3₹88.6 L+₹9.9 L (12.6%)Rejected-Finance PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | ₹88.6 L+₹9.9 L (12.6%) | L3 | Rejected-Finance Reject |
| 4 | L4₹92.8 L+₹14.2 L (18.0%)Rejected-Finance | ₹92.8 L+₹14.2 L (18.0%) | L4 | Rejected-Finance Reject |
Tender Value
Refer Docs
Closing Date
8 Mar 2021, 3:00 pmClosed
CCERNDS SECUNDERABAD
Chief Construction Engineer RnDS PB No.1569 Akbar Road Secunderabad-03
OPERATION AND MAINTENANCE OF ENM INSTALLATIONS DG SETS EOT CRANES AIR CONDITIONERS WATER SUPPLY WATER TREATMENT PLANTS SEWAGE TREATMENT PLANTS FIRE ALARM FIRE FIGHTING SYSTEMS WATER COOLERS WITH WATER PURIFIERS AREA AND PERIMETER LIGHT
2021_DRDO_617120_1
83523/ONM/CDURGA/CON
Limited
Support/Maintenance Service
Item Rate
330 days
Chitradurga
As per NIT
2 documents required · 2 mandatory
₹1,000
Yes
CCERNDS SECUNDERABAD
Exempted
27 Mar 2021
17 Feb 2021
9 Mar 2021
17 Feb 2021
8 Mar 2021
1 Mar 2021
Amount
Operation and Maintenance of Internal & External electrification, DG sets, EOT Cranes, Air-Conditioners, water supply System, Fire Fighting, Fire Alarm, Water Treatment Plant, Sewage Treatment Plant Compressed air line and Area, Perimeter Lighting as per the tender conditions, scope of work and schedule of manpower on all days in a week.
Routine Maintenance & Over Time for the above.
Carrying B-Check for following capacity Diesel Engines for Generators and Fire fighting Pumps by the OEM/Authorized Service agency periodically including all required spares/filters/engine oil etc. as per the instructions of Engineer-In-Charge
a) 750 KVA, 11 KV DG sets (Cummins Model: KTA-38-G10)
b) 200 KVA, 440V DG set (Cummins Model: QSB-67-G12)
c) 62.5 KVA, 440V DG set
d) 30 KVA, 440V DG set
e) 85 bhp Diesel Engine driven Fire Pump (Kirloskar 4R1040T)
'C' Checks for DG Set s
a) 750 KVA, 11 KV DG sets (Cummins Model: KTA-38-G10)
b) 200 KVA, 440V DG set (Cummins Model: QSB-67-G12)
Carrying out annual preventive maintenance like oil filteration, insulation check etc for following capacity transformers/AVR/ Regulator by OEM/authorised agency including cost of standard replaceables/ consumbles etc. but excluding topping up of transformer oil
a) 250 KVA tranformer(320 Ltr)
b) AVR HT Unit(600 Ltr)
c) AVR Regulator Unit(300 Ltr)
d) 750 KVA Transformer(940 Ltr)
e) 630 KVA Transformer(1050 Ltr)
f) 160 KVA Transformer(230 Ltr)
g) 100 KVA Transformer(275 Ltr)
h) 63 KVA Transformer(245 Ltr)
Testing of 11KV VCB alongwith carrying out relay calibration by authorized agency of OEM/agency having license issued by state/central electricity authorities etc.
a) 800A VCBs (Siemens)
b) 800A VCBs (Crompton)
c) 440V ACBs (L&T)
Conducting Load Test by governement authorised agency for 5 Ton EOT Crane
Inspection by OEM for 2 Nos o 5Ton capacity Crane which-includes two visits (i.e once in 5 months) one Engineer & one techinican duly carring over inspection of both the cranes i.e all electrical & mechanical items, running the crane and testing the components, preparation of inspection reports and recommendation of necessary spares/repair works. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges.
Inspection by OEM as and when required during the brake down of 1 No 5Ton capacity Crane which-includes one Engineer duly carring over inspection of the crane i.e all electrical & mechanical items, running the crane and testing the components, preparation of inspection report. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges.
Supply of gear oil for 5T cap crane
Supply of brake oil for 5T cap crane
Supply of grease
AMC for Water Coolers 40/80 Ltrs cap including RO Water Purifiers With 50LPS
AMC for Water Coolers 40/80 ltrs cap including RO Water Purifiers With 15LPS
AMC for 20ltrs Storage type Hot & Cold Water cooler with 16LPH RO purifier
AMC of Fire Alaram System
Periodical Servicing by OEM of Fire Alarm System once in 3 (three) months by Engineer and technician for all the Buildings as per invaentory. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges of technicians
Emergency visit by Engineer with technician for attending emergency failure. The cost should include all expenses including travelling, local conveyance, lodging and boarding charges of technicians. Cost for additional days would be needed for completing the work is extra as belows
Additional days on emergency visit
Identification of fault in Optical Fibre Cable by hiring machinery for Cable Fault locator
Identification of FO cable inclduing hiring of machinery for cable fault locator, JCP for earth removal and replacement
Identification of fault in LT Cable of various sizes by hiring machinery for Cable Fault locator
a) First fault
b)Second fault
Identification of fault in HT Cable of various sizes by hiring machinery for Cable Fault locator
a) First fault
b)Second fault
Supply of concentrated Sodium Hypochlorite liquid (as per Indian Standards) for treatment of drinking water including transportation and unloading at pump houses as and when required.
Sand Media mixed
Activated carbon 450IV
Activated carbon 900IV
Strainers
Supply of Transformer oil (mineral) as and when required as per the instruction of Engineer-in-charge
Supply and filling of Refrigerant gas of for all types of air-conditionerrs as per requirement and instructions of Engineer-in-charge
Rewinding of Indoor/Outdoor fan motor for following capacity and type of Air-Conditioners
a) 11.0 TR Ductable AC
1)Indoor Fan Motor
2)Outdoor Fan Motor
b) 8.5 TR Ductable AC
1)Indoor Fan Motor
2)Outdoor Fan Motor
c) 5.5 TR Ductable AC
1)Indoor Fan Motor
2)Outdoor Fan Motor
d) 3.0 TR Casstte AC
1)Indoor Fan Motor
2)Outdoor Fan Motor
e) 1.5/2.0 TR Wall mounted Split AC
1)Indoor Fan Motor
2)Outdoor Fan Motor
Capacitors for 11/8.5/5.5/3/2/1.5 Tr Acs
Contactor 4P 18A
Contactor 4P 32A
Rewinding of following capacity and type of motor
3-Ph, 415V, 1.5 HP monobloc pump set
3-Ph, 415V, 3.0 HP monobloc pump set
3-Ph, 415V, 5.0 HP monobloc pump set
1-Ph, 230V, 1.0 HP submersible sludge pump set
3-ph, 415V, 5.0 HP Submersible Borewell pump set
3-Ph, 415V, 7.5 HP Submersible Borewell pump set
Supply and fixing of e-cell electrode made up of Aluminum alloys of size 400mmx400mmx5mm thick x 10 Nos. plates for Electrolysis tank(e-cell) of Sewage Treatment Palnt of capacity 30 KLD as required.
Distilled Water
Hardness Test kit
PH Buffer Powder 6.86@25C & 4.01@25C(Set of Two)
Supply of following mentioned spare as per the terms & conditions and specifications mentioned in the enquiry. All items shall be as per Indian Standard codes and Specifications followed for Electrical Systems.
Consumables
9/11W CFL 2 Pin
9/11W CFL Electronic Ballast 2 Pin
18W CFL 4 Pin
18W CFL Electronic Ballast 4 Pin
18W CFL 2 Pin
18W CFL Electronic Ballast 2 Pin
Electronic Ballast EBE 228 TL5
Electronic Ballast EB-T 128 TL5
Electronic ballast EB-T 236 TLD
Electronic ballast EB-T 136 TLD
70W SV Lamp Elliptical
70W Copper Wound Ballst Open k) Construction
150W SON-T SV Lamp Tubular
150W Copper Wound Ballst Open Construction
Ignitor for SV lamp 70W/150W/250W/400W
Surge protection device for 150W street Light
90W LED Driver (Philips)
150W LED Electronic Driver (Philips: Xitanium 150W 0.7A
18W CFL Wall bracket Fixture(Philips:FL800/320)
LED driver for RC380BLED-30-6500PSEODWH
LED driver for 40W SODQL-54-700-40W (Crompton)
40W Halogen lamp for QWZ807(Philips)
40W Halogen lamp for QWZ812(Philips)
Foot Lamp with Box & lamp Holder(MK :W26530)
150W Metal Halide lamp for SWF231 1XMHNTD-150W(Philips)
70W Metal Halide lamp for MPF92 1XMHNTD70W(Philips)
2.25Mfd Capacitor for Fan
90W LED Driver (Philips)
63A, 4P C Curve MCB
440V, 40 kA, 4 Pole SPD for installation in MCB DB
25A, 12KV HRC Fuse (With Striker for tripping)
40A, 12KV HRC fuse (With Striker for tripping)
63A,12 KV HRC fuse(With Striker for tripping)
20 W LED Tube light fitting
RCBO Legrand 63A ,4P,100mA
6-32A, 1P C Curve MCB
63A, 3P,C Curve MCB
400W Mercury Vapour lamp, Elliptical, threaded
400W choke Philips
36W, 4Pin CFL
16A , 5Pin socket
6A, 5Pin socket
16A switch
6A Switch
230VAC/12V DC SMPS
Testing charges of drinking water
Testing charges of sewage water
Industrial salt
Rewinding of 60W ceiling fan
Rewinding of 75W Exhaust fan
100W , 5Step regulator
3Cx4 Sqmm Al flexible cable
Rewinding of 90W Exhaust fan
Supply & Fixing of Start/Stop push buttons
Supply & Fixing of LED Indication lamps
Silca Gel
Supply Fixing, testing & commissioning of Multi Sensors detectors
Supply Fixing, testing & commissioning of Manual Call Points
Sediment filter (Kent: Spare part code:20011)
Sediment filter (Kent: Spare part code:20013)
Activated carbon filter(Kent: Spare part code:20012)
Activated carbon filter(Kent: Spare part code:20014)
RO Membrane(Kent: Spare part code:20531)
RO Membrane(Kent: Spare part code:20002)
FRT(Kent: Spare part code:20018)
Solenoid Valve(Kent: Spare part code:20028)
Booster Pump with pump Head (Kent: Spare part code:20006 & 20059)
Booster Pump with pump Head (Kent: Spare part code:20005 & 20059)
SMPS(Kent: Spare part code:20016)
UF Memberane (Kent: Spare part code:20004)
Carbon Block Filter(Kent: Spare part code:20673)
Post Carbon Filter (Kent: Spare part code:20015)
Auto Flash PCB (Kent: Spare part code:20023)
TDS Control valve(Kent: Spare part code:20034)
UV lamp(Kent: Spare part code:20540)
UF Filter(Kent: Spare part code:20003)
Ballast(Choke)(Kent: Spare part code:20021)
Aquaguard RO Kit
MFD Capacitor,240V
3Cx4Sqmm CU flexible cable
3Module surface plate
4Module surface plate
6 Module surface plate
8 Module surface plate
3Module surface Box
4Module surface Box
6 Module surface Box
8 Module surface Box
Supply Fixing, testing & commissioning of LT straight through joints of following sizes:
1)1.1KV, 3.5Cx50sq.mm
2)1.1KV, 3.5Cx120sq.mm
3)1.1KV, 3.5CX240sq.mm
4)1.1KV, 3.5CX300sq.mm
4)1.1KV, 4CX16/4CX10sq.mm
Supply Fixing, testing & commissioning of HT straight through joints of following sizes:
1)11KV, 3CX95sq.mm
2)11KV, 3CX185sq.mm
3)11KV, 3CX240sq.mm
Supply following of HT XLPE 11 KV cable
1)11KV, 3CX240sq.mm
Supply following of HT XLPE 11 KV cable
1)1.1KV, 3.5Cx185sq.mm
1)1.1KV, 3.5CX240sq.mm
Supply of Geyser Heating Element
Supply of Geyser Thermostat
Supply of Geyser Hose Pipes
Analogue addressable type multi sensor (smoke/Heat) photo electric detectors
Response indicators
Analogue addressable Ordinary Manual call points
Provision of 4 Wheel Drive Multi Utility with Maintenance Ladder along with Driver having nexperience/License in Hill Driving on Hours Basis per Maintennace of Street Light at Perimeter Road all along the compund wall.
12V, 160AH Maintenance Free Heavy duty battery (Cummins Pulse Lite)
12V, 65AH Maintenance Free Heavy duty battery(Cummins Pulse Lite)
2 V Cells of 100AH
Credit SMF Battery 12 V , 7Ah
Credit for 2 V Cells of 100AH
Credit for Old Batteries 12 V 150 AH
Millennium Power and Security Solutions
CHARAN ELECTRICALS
Gee Yes & company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .