Loading…
Loading…
Tender Value
₹37.3 L
EMD Value
₹37,254
Closing Date
21 Sept 2026, 6:00 pmClosed
Chief Officer
Construction Work of R.C.C Road, Drainage line, LED Street Light and Highmast Pole in Nagarpalika Various Area @ Kheda Nagarpalika, Kheda Dist. Kheda
342439
10/2026-27
Open
Civil Works
Works
Kheda
3 documents required · 3 mandatory
₹1,770
Chief Officer Kheda Nagarpalika
₹37,254
6 Sept 2026
6 Sept 2026
6 Sept 2026
21 Sept 2026
6 Sept 2026
Name of work : Construction Work of R.C.C Road, Drainageline, Streetlight and Highmast Pole in Various
Area @ Kheda Nagar Palika, District: Kheda.
Sr. No. Discription of Work Estimated Amount
Construction Work of C.C Road & Drainage Line from Gitamandir Vakil Shop to Peoples Bank Ward No.06
Supplying & Installing LED Street & Hight Mast Pole from Kheda Bus Station Chokadi to Shantinagar Society
Waterworks Bore to Kheda Nadiad Highway
SB-1 (Construction Work of C.C Road & Drainage Line from Gitamandir Vakil Shop to Peoples Bank Ward
Sr No Qty DESCRIPTION OF ITEM RATE PER AMOUNT
Demolition including stacking of serviceable materilas and disposal of unservice-
able materials with all lead and lift. (i) R.C.C. work
Box cutting the road surface to proper slop and chamber for making a base for
2 40.00 work including removing the excavated stuff and depositing on the road side slop 104.20 Cmt
as directed upto 50 mts. Lead
Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all
with shoring and struting if required as per required gradient and line including
safety provisions using site rails and stacking excavated stuff including up to all
required lead cleaning the site etc. complete for all lifts and strata as specified.
201.00 (A) In all sorts of soil and soft murrum 102.35 Cmt
Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp.
4 67.50 to prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl. 4211.30
consolidation curing etc. complete. Cu.m
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
5 166.00 foundations etc. in layers not exceeding 20 cm. in depth consolidating each 130.39
disposited layer by ramming and watering. Cu.m
Providing and supplying ISI Standard R.C.C. pipes (of Sulphate Resisting Cement) in
standard lengths of following class and diameter suitable for either collar joints or
rubber ring joints including all taxes, insurance, transportation, freight charges,
octroi, inspection charges, loading, unloading, conveyance to departmental stores,
6 100.00 stacking etc. complete. (IS - 458/ 1989 (Class NP3 Test Pressure 0.7 Kg/sq.cm 479.55 Rmt
200mm Dia.) Note : One collar should be supplied with each full length plain ended
RCC pipe, cost included in rates below. One rubber ring should be supplied with
each full length socketed pipe, cost included in rates below.
Lowering, laying and jointing R.C.C. pipes in C. M. 1:1 1/2 of following diameters in
proper position, grade and alignment at all level as directed by Engineer-in-charge
including conveyance from stores to site of work, labour, giving hydraulic testing as
per ISI code (NP-3 225mm Dia. Pipe)
Providing and supplying ISI marked only Standard length Stoneware pipes in
standard lengths of following class and diameter including all taxes, insurance,
8 transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete. (IS - 651 / 1989)11.2
Lowering, laying and jointing Stone Ware pipes of following diameters with cement
joints in C. M. 1:1 proportion in proper position, grade and alignment at all level as
directed by Engineer-in-charge including conveyance from stores to site of work,
Jointing material etc. comp.
Providing and constructing Sewer manholes, scraper manholes and unit house
connection chamber, as per the type design in brick masonry in C. M. 1:5 and inside
and outside 20mm thick plastering in C. M. 1:3 necessary 100 mm coping with
reinforcement in R.C.C.M. 200 fixing C. I. steps and fixing manhole frame and
10 covers (But excluding supply of manhole frame and covers) over manholes and
house connection chambers and fixing Manhole covers (but excluding supplying of
manhole covers) over scraper manhole etc. complete, providing and fixing safety
chain wherever necessary as per the stipulations in the type design complete as per
latest CPHEEO manual. (excl. excavation).
(B) Manhole type "B" circular type having inside diameter of minimum 1500 mm
and for depth from 1.5 M to 4.0 M (for 150 mm to 600 mm dia sewers)
1 5.00 1). Manhole type "B" as above but upto 1.5 M depth. 24283.40 No
2). Extra depth beyond 1.5 M but upto 4.00 M depth for "B" type manhole above.
Providing and constructing rectangular brick masonry chamber for house
connection as per type design in brick masonry in C. M. 1:3 including M-100 in
11 foundation M-150 in benching inside plastering in C. M. 1:3 and outside plastering
in C. M. 1:3 coping in M200 and fixing RCC precast manhole frame and covers, but
Excl. supply of manhole and cover etc. complete excl. excavation.
12.00 Section 2 D, Page No. 102, Item No. 4 1188.30 No
Restoration : Restoration of Infrastructure like Kharkuva, electric line, water supply
line, telephone cables all type, gas line, septic tank etc
(i) 5.00 up to 1.50 m depth 2418.85 No
(ii) 5.00 up to 3.00 m depth 2553.75 No
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store or at site
of work precast RCC M.200 Frame & cover suitable to drainage M.H. and as per
type design & Drawing including cost of reinforcement M.S. Angles or Flat, curing
10.4.A Heavy duty
1 5.00 Frame suitable for 50cm opening of MH 1289.15 No
2 5.00 Cover suitable for 50cm opening of MH 1348.95 No
10.4.C House Connection Chamber light duty
Providing and laying Nominal cement concrete M.200 (1:1.5:3) and curing
complete excluding the cost of formwork and reinforcement for reinforced
concrete work including prepairing sub base by Providing & Laying M.S. Side rail of
road thickness with necessry nut bolt plates, fixing as per width applaying plates
14 vibrator, electric or diesel on channel comp. with V.D. Systems (Trimix) by using the 4964.95 Cu.M
necessary equipments 7 material & Machinery, such as running screed vibrator on
prelaid M.S. channel for leveling vaccum pumps, floating & power trowling etc.
Providing TMT Bar FE 550D reinforcement for R.C.C. work including bending,
1500.00 binding and placing in position complete upto floor two level
Making groove of 5mm wide and 50 mm Deep, Cleaning groove before filling
16 bitumen and filling bitumen with required sand on surface and cleaning site as 70.70 Rmt
80.00 directed by Engineer In Charge.
Add 2.00 % Contigency
SB-2 (Supplying & Installing LED Street & Hight Mast Pole from Kheda Bus Station Chokadi to Shantinagar
Sr. No Qty DESCRIPTION OF ITEM Rate Per Amount
Supplying and erecting LED street light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power
1 24.00 Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire 3345.12 No
efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage protection. (i) above 36 to 48 watts Cat-lll
Supplying and erecting approved make Conical Pole (Medium Duty ) Made from HR sheet
steel. The pole should be made as per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, with required base plate and integral Junction box consist of terminal
plate of min 6mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting,
2 24.00 stud type terminal and arrangement for cable terminations as erected on suitable 10169.69 No
foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given by
manufacturer considering site requirement. The length of poles are as below. (D) 6 Mtr.
Long 70 mm Top X 160 mm bottom dia, 3 mm thickness
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation
for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x
3 24.00 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in 809.01 No
approved manner.
( for 4 & 6 mtr pole)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper
4 756.00 conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe 987.78 Mtr.
at road crossing or floor of following size of cables. (B) 4 core 16 Sq. mm
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner
pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate including value of earth resistance of
installation duly stamped and signed by agency and officer Incharge has to ensure the value
of earthing resistane mentioned in test Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (c) For Electrical Installation covering
Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer
System(like Automation, SCADA) i.e independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Providing and erecting Street Light pole bracket comprising main B Class GI pipe of
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient
6 24.00 fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with 683.77 No
vertical plane & suitable welded stays, reducer and with check nuts complete painted with
one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with
following nos of arms. [A] Single Arm Bracket 1.5 Mtr
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out
approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for
7 24.00 mounting mob & hinged doors as per requirement having locking arrangements with 414.10 No
mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps&
earth bolt of following size of box.(B) 250mm x 200mm x 100mm [deep]
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA
8 24.00 breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 278.76 No
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for
9 600.00 laying any size of cable or locating the fault all over the run and back filling the same and 357.54 Mtr
making the surface as normal ground.
Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. dia. galvanised
10 24.00 iron pipe with coupling and buch buried in specially prepared earth pit complete with 368.65 No
necessary 8 SWG earth wire.
11 24.00 For using salt and charcoal / coke as required for pipe type earthing. 171.70 No
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be
erected as directed of following size. (E) 3 core 2.5 Sq. mm
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of cable. below ground / road
surface for enclosing cable (A)50 mm outer dia
Supplying, erecting, testing, commissioning approved make M.S. Polygonal High
Mast Pole having following general Specification.
(a) Polygonal Section fabricated from M.S. Plate confirms BSEN 10025 & Hot deep
galvanized minimum 65/86 micron (as per IS 2629 /1985) Lantern carriage with
ring and rubber lines for erection of luminaries of suitable site.
(b) Maximum telescopic section not more than four
(c) Double drum gear pipe motorized winch with 6mm dia S.S. Rod (For 16 mtr and
(d) Approved make L.E.D. aviation light = 1 No. Lightening arrestor = 1 No. with
necessary wiring of 2.5 sq.mm 5 core ISI copper cable Unarmoured.
(e) Bottom most section suitable for mounting reversible motor and switchgears
having door not more than 1400mm x 300mm with waterproof gasket & hinges &
locking arrangement.
(f) Pole structure comprises suitable size of reversible motor, cable and necessary
switchgears with control panel.
(g) bottom section shall have suitable size of thickness supports ribs foundation
bolts nuts etc.
(h) Item not comprises the cost of lanterns.
(i) Necessary Cement Concrete foundation as per IS including testing &
2.00 commissioning of the entire structure for following size of High Mast poles 141616.14 Ea.
[1] High Mast 12 Mtr. TOP A/F 105 mm, BOTTOM A/F 360mm, No. of Sec. No. -
Bottom Thickness - 3 mm, Size of Base Plate - Dia 520 mm x 20 mm thick,
Foundation Bolt Size M24 x 850 mm, Qty - 6 Nos., Suitable for mounting Fitting of
Supplying and erecting LED street light / Flood light fittings with High power White
LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast aluminum housing with
smooth finish powder coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges shown.)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC
12.00 line supply with over-voltage protection. (iv) above 90 to 120 watts Cat-iii 7266.95 Ea.
Smart 4G Timer, Supply of IoT based 4G Smart Streetlight Control & Monitoring System
having a Smart Panel comprising of 3 Phase IoT Streetlight Smart 4G Timer with 16x2 LCD to
display RSSI, relay status, RTC time & diagnostics., Controller works on 3-phase & also on any
available 1-Phase., Controller with 8-hour battery backup during external power failure.
External power failure alert immediately to cloud., 110-630 V AC @ 50-60 Hz – 3 phase
operating range., Standby power consumption <3W., Smart 4G Timer with RS232 port for
DLMS Energy meter., Smart 4G Timer must be compatible with any make / brand of DLMS
(RS232) Energy Meter., DI: 4 Nos. (3 Contactor / Latch detection, 1 for Door Sensor.)., DO:
Relays for Independent control each phase (R, Y, B) with 1 extra spare relay., Smart 4G Timer
with dual SIM functionality for connectivity backup., 4G M2M SIM 3-Year communication
included., Local configuration via WiFi / BLE for maintenance or during force majeure., GPS
chip inbuilt of Smart 4G Timer for auto location tracking & astronomic schedule location.,
50 programmable schedules., Astronomic scheduling with monthly offsets., Smart 4G
Timer has inbuilt timer stores schedules locally & also stores schedule execution logs locally,
syncs to cloud whenever connected to cloud., Auto-scheduler overrides manual operations.,
Monitoring & alerts for MCB trips., Over/under voltage, current, overload, power factor &
short circuit protections with alerts via Dashboard, App, SMS, WhatsApp & Email., Contactor
/ Latch chattering protection & alerts., Smart 4G Timer with neutral failure protection and
alert., Bulit-in Watchdog for anti-jamming., Smart 4G Timer must send Regular "heartbeat"
on software for CCMS status.,
Accelerometer for tamper & panel movement detection & alerts., Smart 4G Timer must be
tested from an NABL Lab for Surge Test @ 6 KV (IEC 61000-4-5), ESD Test @ 4 KV (IEC 61000-
4-2), EFT @ 2 KV (IEC 61000-4-4), Conducted Emission @ 150 KHz-30 MHz (CISPR11), Damp
Heat Test (40 Deg C @ 95% RH) 2 cycles of 12+12 hours (IS: 9000 (Part 5/Sec.2):1981 latest)
with all test passing criteria as “Temporary degradation or loss of function or performance
which is self-recoverable”., FOTA functionality required for upgrades., Smart 4G Timer sends
& stores online/offline data of controller & load for lamp burn hours analysis.,
It stores & syncs connectivity logs for configuration of network connections & analytics.,
PANEL & SWITCHGEAR, The panel includes a Class 1 DLMS energy meter NABL approved
with 1-2 months of stored data of daily, hourly, monthly, load survey, instantaneous, events,
tamper data & with power events stored in meter memory for audit purpose., Must monitor
V, I, KWH, KVA, PF, KVAH, etc., Panel made with 2 mm CRCA sheet with ground mountable
stand complete with gland plate, waterproof glands, earthing bolt., IP55, weatherproof
panel with RAL7035 powder-coated., Smart 4G Timer must be fitted on removable terminal
sockets for easy maintenance., Switchgear includes 3 Nos. 3 pole Contactor / Latch having
minimum 50 A Load carrying capacity per phase, all other switchgear & wires: 40 A load
carrying capacity., 1 Nos. 4P MCB 10 kA for Incomer & 6 Nos. 1P MCBs 10 kA for Outgoing.,
Phase-Wise Bypass MCBs required., 4P RCCB 100 mA., door sensor. Also, provide lock & key
facility., Panel mount outdoor antenna for GSM, GPS., Canopy design for draining down
water., CCMS SMART SOFTWARE, OAuth 2.0 APIs for sending data to Government
clouds/software, etc., CCMS Web dashboard with secure password & OTP login., Hosted on
trusted cloud, data security, antivirus & attack protection., HTTPS., AES256-bit encryption.,
Vulnerability Assessment and Penetration Testing (VAPT) certificate for CCMS Software.,
Streetlight management software for load status, live analytics & reports., Energy meter
data tables (kW, kWh, PF, I, V, etc.) available., Utility monthly bill reconciliation & Class
accuracy reports for billing, energy monitoring & auditing for streetlight load., Fault
detection., Light fault 99% analysis on dashboard using energy monitoring., WhatsApp
integration., Hierarchy-wise reporting & alerts., GIS mapping of live connected streetlight
control panels, poles & streetlights., MQTT protocol., Smartphone app with local
configuration & navigation., Monitoring & reporting of lighting parameters., Facility for
media attachments for site photos/videos/work permits/checklists, etc. per Feeder Panel for
remote verification., Asset management module for streetlight infrastructure data.,
Complaint/service task management with history & escalation must be available., Android &
iOS App for dashboard analytics, graphs, energy data, alerts., 3 Years CCMS Web Software &
Cloud Server Hosting subscription included., Customizable, user-friendly dashboard.,
Add 2.00% Contingency Rs.
Add 1.00% Quality Control Rs.
Grand Total Rs.
Grand Total Rs.
Say Total Amount
Say Total Amount
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD.pdf
Schedule-B.pdf
03. ROADWORKSBOOKLET.pdf
04. Electrical Specifications.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .