Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹45.0 L+₹4.3 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹47.4 L+₹6.7 L (16.6%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
18 Aug 2021, 6:00 pmClosed
CWE NW KOCHI
KATARIBAGH NAVAL BASE PO KOCHI 682004
PROVISION OF SERVER ROOM NEAR ATC BUILDING AT INS GARUDA
2021_MES_457817_1
CWE(NW)KOCHI/81193
Open Tender
Civil Works
Lump-sum
270 days
KOCHI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE NW KOCHI
₹68,000
Yes
30 Nov 2021
7 Jul 2021
20 Aug 2021
7 Jul 2021
18 Aug 2021
4 Aug 2021
8 Jul 2021 - 16 Jul 2021
Amount
List of Works
Schedule 'A' Part-I to IV
Total amount of Sch 'A' part-I (Building / structures)
Total amount of Sch 'A' part-II (Site Clearance, Excavation and Earthwork)
Total amount of Sch 'A' part-III (External Electric Supply)
Sch 'A' Part- IV ( Miscellaneous Items) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
Boring for 500mm dia cast-in-situ bored piles to 52.50 M depth through any type of soil/strata by DMC method using betonite slurry incl removal of bored materials to places outside MD land complete all as specified and as directed .
M&L for RCC of grade M-40 design mix as per IS-456 (with using 20mm graded stone aggregate) in piles of any length/any section complete all as specified and as directed.
CRS/HCRM TMT bars in reinforcement 10mm dia and over for pile all as shown on drawings incl cutting/hooking end if necessary and welding so as to secure the bar firmly in position/required shape complete all as specified and as showm on drawing
M&L for CRS/HCRM TMT bars in reinforcement 5 mm dia and over, bent to shape required, for pile helical bar and ring of piles including necessary tack welding to pile reinforcement at all points of contracts complete all as specified and shown on drawing
M & L for RCC M-40 Design mix concrete using 20 mm graded stone aggregate as in pile cap and grade beam all as specified. (Note: Reinforcement shall be measured and paid separately)
M&L CRS/HCRM TMT bars 10 mm dia and over as in main re-inforcement conforming to IS-1786 as in pile cap, plinth beam including cutting, bending, welding, tying assembling, placing maintaining the reinforcement cages in position complete all as specified and as directed.
All as per item No 12 above but 5 mm dia & over as in stirrups for pile cap and plinth beam necessary tack welding to pile reinforcement at all points of contacts complete all as specified and as directed.
M&L PCC 1:4:8 type D2 using 40 mm graded aggregates as in sub base for pile cap and plinth beam complete all as specified and as directed.
M & L for form work to concrete pile cap & grade beams, rough finished surface complete all as specified and as directed.
Excavation in trenches n.exc 1.5m deep & n.exc 1.5m wide and n. exc 10 sqm on plan, in soft/loose soil and getting out complete all as specified and as directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exc 50 m and depositing where directed at a level above the starting point complete all as specified and as directed.
Testing of piles (initial load test) all as per IS including removing the testing equipments from site after testing is compacted all as specified and directed for 500 mm dia cast in situ piles complete all as specified and as directed.
Testing of piles ( Routine Load Test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed for 500 mm dia cast in siru piles complete all as specified and as directed.
Supply, installation, testing and commissioning of split air conditioning unit 2 TR capacity Inverter type complete with cordless remote control, minimum 3 star labelled, eco friendly refrigerant gas, 4500 Kcal / Hr, 50 Hz, 240 volts, air cooled copper condenser with all accessories varied speed including fixing the out door unit with suitable stand as site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/ making holes to pass the refrigerant pipes, drain pipes, cables etc and making good to match with existing finishing complete, providing and making interconnection, including suction and discharge copper pipes with refrigerant including with nitrile rubber insulation and control cable from indoor to outdoor as required at site, Power cabling from Isolator/ Enclosure to unit, first charging of refrigerant gas, drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified and as directed. Make: Carrier/Hitachi/Blue Star/ Daikin
Supply and fix 4 KVA capacity Voltage stabilizer, copper wounded suitable for 2 TR inverter type split AC, automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5%, fixed on wall with necessary arrangements complete all as specified and as directed. Make: V Guard/AE/Microtek
M&L for point wiring complete with ISI marked single core PVC insulated unsheathed 1100volt grade FRLS cable with multi strand copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and including provision of pressed steel terminal box powder coated of suitable size fabricated out of 2mm thick MS sheet with 3 mm thick laminated sheet cover for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade FRLS cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified for one light point controlled by one switch complete all as specified and as directed.
All as per item No 23 above but for one 5 pin 5A socket outlet point on independent board complete all as specified and as directed.
All as per item No 23 above but with 2.5 Sqmm (nominal area) cable PVC FRLS insulated but unsheathed one 6 pin16 Amp socket outlet on independent board including 2.5 Sqmm copper conductor green in colour for earth continuity complete all as specified and directed.
All as per item No 23 above but with 4 Sqmm copper conductor including 4 Sqmm copper cable on earthwire for socket outlet independent board complete all as specified and as directed.
S&F Switch piano flush type 5 amps single pole one way complete all as specified and as directed.
S&F ceiling rose surface bakelite 65X50 mm 3 terminals complete all as specified and as directed.
S&F switch socket combination 5 pin 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination 6 pin 16 Amp universal complete all as specified and as directed.
S&F fan regulator suitable capacity electronic type 230V step type complete all as specified and as directed.
S&F Flame proof LED tube light fitting 1X20W with heat resistant tubular glass cover held in two aluminium cups with built in control gear accessories surface mounted CMRI certified IP 65 protection with reflector complete with all accessories including connection complete all as specified and as directed.
S&F 20W tube light fitting wall mounted LED batten extruded aluminium heat sink providedfor efficient heat dissipation and integrated electronic driver complete all as specified and as directed.
S&F ceiling fan 1200 mm sweep,230V SP complete with suitable size down rod which ever be reuired at site complete all as specified and as directed.
S&F independent telephone socket RJ 11 with shutter one module complete all as specified and as directed.
S&F rigid non metallic PVC concealed conduit 20mm dia and chases cutting including junction/terminal box & all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers ,lock nuts,saddles,pipe hooks complete all as specified and as directed.
S&F sheet metal enclosure with a two pin and earth plug and socket comlete with one single pole MCB 20A capacity complete all as specified and as directed.
S&F sheet metal enclosure double door for MCB DB VTPN 4 way with 100 A MCCB TP,16KA as incomer and provn of SP/TP MCBs as outgoing complete all as specified and as directed.
S&F MCB SP 5 to 40A complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electorde 60 cm x 60cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meters below normal gound level, connected to GI wire 4mm dia as earth lead upto length 7.5 mtr by means of bolts, nuts and washeres of galvanised steel all as shown in electrical plate No 5 connected to earthing test point complete all as specified and indicated including testing on completion. Note : The rate is deemed to be inclusive of the cost of complete earth work in any type of soil. PCC 1:3:6 type C-1 for chamber, RCC 1:2:4 type B1 for cover slab 50 mm thick, reinforcement 8 mm CTD bars @ 100 mm c/c both way, necessary form work, handle, charcoal dust 20mm dia GI med grade for watering and 40mm dia GI med grade earth lead protection pipes wtih PGI funnel and wire mesh all complete all as specified and directed.
External Electric Supply Cutting existing road/hard stand of any type by using crown bar chisel etc not exceeding 45cm wide and not exceeding 1.5m depth for laying GI pipe including making good the surface by returning filling watering ramming in layers 150mm thick PCC 1:2:4 over 200mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25cm thick complete all as specified and directed . (Pipe shall be measured seperately).
M&L for replacement of XLPE insulated galvanised steel strip or wire armoured electric power cable with stranded aluminium conductor 1100V grade of size 50 Sqmm 3.5 core complete all as specified and as directed.
M&L for GI tubing in trenches/fixed on walls /poles tubing of medium grade with all fittings of 50mm bore complete all as specified and as directed.
S&F MCCB 100 Amps 16kA 4 pole complete all as specified and as directed.
THOMSONS CONSTRUCTIONS
WELTRONENGINEERINGSERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .