| 1 | H1₹29.6 LAdmitted-Finance 118 TIRUPATHI INDUSTRIAL ESTATE SUBASH NAGAR NAHUR WEST BHANDUP WEST MUMBAI MAHARASHTRA 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | H1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Weltech Refrigeration Co. H1 |
|---|---|---|---|---|
| 1.00AIR COOLED WATER CHILLER FOR BFS MACHINE | ||||
| 1.10 | Supply , Installtion , tesing , commissioning and validation of stand alone water chiller as per URS | 1 | No | 18,30,000 ₹18,30,000 Lowest |
| 2.00PIPING WITH ACCESSORIES Supply & installation of SS 304 ERW pipe ( Sch-10) , with required supports, fittings, flanges, etc. for supply and installtion of chilled water from poratble chiller to BFS machine and connection in both end with machines | ||||
| 2.10 | 50 mm diameter pipe | 80 | RMT | 7,60,000 ₹7,60,000 Lowest |
| 2.20 | Ball Valve ( For by pass in between inlet and outlet chilled water pipe) Pipe size : 50 mm | 3 | NOS | 75,000 ₹75,000 Lowest |
| 2.30 | Pressure gauge with probe for measuring the pressure through test port (Range - 1 to 10 bar) | 2 | NOS | 11,800 ₹11,800 Lowest |
| 3.00INSULATION ( For pipes & fitting ) Supply & installation of Physically / Chemically crosslinked polyethylene foam, with factory laminated heavy duty and ultra tough multi-layered composite aluminium foil facing, with puncture resistance of >400N and Class O fire properties as per BS 476 Part BS 476 Part 6 & 7 and density of the foam should be not less than 25 - 30 kg/m3 and maximum thermal conductivity K should be 0.032W/mK@ 23 Deg C & the permeability resistance factor u , shouldn't be less than 97000. | ||||
| 3.10 | Insulation thickness 32 mm thick | 70 | RMT | 1,29,500 ₹1,29,500 Lowest |
| 3.20 | Aluminium cladding | 60 | RMT | 1,29,000 ₹1,29,000 Lowest |
| 3.30 | SS Cladding | 10 | RMT | 27,000 ₹27,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
11 Aug 2025, 11:00 amClosed
MANAGING DIRECTOR KSDP
KSDP LTD,KALAVOOR P.O ALAPPUZHA
SUPPLLY INSTALLATION TESTING COMMISSIONING AND VALIDATION OF AIR COOLED WATER CHILLER FOR BFS MACHINE
2025_ksdp_774868_2
KSDP/PRJ/CHILLER/2025-26/19
Open Tender
Miscellaneous Works
Item Rate
KSDP LTD, KALAVOOR P.O ALAPPUZHA
Please refer Tender documents.
16 documents required · 16 mandatory
₹8,850
Yes
₹30,000
Yes
14 Aug 2025
1 Aug 2025
12 Aug 2025
1 Aug 2025
11 Aug 2025
1 Aug 2025
1 Aug 2025 - 11 Aug 2025
AIR COOLED WATER CHILLER FOR BFS MACHINE
Supply , Installtion , tesing , commissioning and validation of stand alone water chiller as per URS
PIPING WITH ACCESSORIES Supply & installation of SS 304 ERW pipe ( Sch-10) , with required supports, fittings, flanges, etc. for supply and installtion of chilled water from poratble chiller to BFS machine and connection in both end with machines
50 mm diameter pipe
Ball Valve ( For by pass in between inlet and outlet chilled water pipe) Pipe size : 50 mm
Pressure gauge with probe for measuring the pressure through test port (Range - 1 to 10 bar)
INSULATION ( For pipes & fitting ) Supply & installation of Physically / Chemically crosslinked polyethylene foam, with factory laminated heavy duty and ultra tough multi-layered composite aluminium foil facing, with puncture resistance of >400N and Class O fire properties as per BS 476 Part BS 476 Part 6 & 7 and density of the foam should be not less than 25 - 30 kg/m3 and maximum thermal conductivity K should be 0.032W/mK@ 23 Deg C & the permeability resistance factor u , shouldn't be less than 97000.
Insulation thickness 32 mm thick
Aluminium cladding
SS Cladding
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .