Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC THAYYILTHAZHAM KONOTT P O KOZHIKODE 673 571 | KOZHIKODE | KOZHIKODE | KERALA | 673571 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹6.0 L+₹31,900.20 (5.66%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹6.0 L+₹34,349 (6.09%)Rejected-AOC | L3 | Rejected-AOC REJECTED |
| Sl No | Description | Qty | Unit | LUMEN ENGINEERING L3 | K MANOHARAN L1 | MOHANAN T L2 |
|---|---|---|---|---|---|---|
| 1.00Electrification | ||||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 66 | point | 1,050 ₹69,300 Lowest | 1,325.95 ₹87,512.7 | 1,365 ₹90,090 |
| 1.00 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | 10 | each | 450 ₹4,500 | 430.14 ₹4,301.4 Lowest | 445 ₹4,450 |
| 1.00 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 7 | each | 850 ₹5,950 | 527.76 ₹3,694.32 Lowest | 545 ₹3,815 |
| 1.00 | 1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). | 5 | each | 650 ₹3,250 | 612.52 ₹3,062.6 Lowest | 633 ₹3,165 |
| 1.00 | OD117326/2025-2026:Supply and providing the following types and power rated lamps in the existing fittings as required9W LED bulb | 13 | each | 85 ₹1,105 Lowest | 107.61 ₹1,398.93 | 111 ₹1,443 |
| 1.01 | 90.3.20.3:Supply & installation of light fittings on TW round block
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture | 4 | each | 1,150 ₹4,600 | 1,073.98 ₹4,295.92 Lowest | 1,109 ₹4,436 |
| 1.01 | 90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket
Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture | 19 | each | 1,200 ₹22,800 | 1,117.07 ₹21,224.33 Lowest | 1,154 ₹21,926 |
| 1.01 | OD117866/2025-2026:Supply and fixing LED bulk head (Philips WT140W Vistaglow or equivalent) fitting on wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. | 4 | no | 900 ₹3,600 | 789.15 ₹3,156.6 Lowest | 815 ₹3,260 |
| 1.01 | OD117871/2025-2026:Supply, Conveyance, installation, testing and commissioning of led surface mount fitting LED 600*600 mm(2ftx2ft) Luminaire having light output not less than 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) luminaire Housing Shall be made from single piece CRCA body without welding to avoid rusting and Prismatic diffuser to reduce glare. The Luminaire should be having minimum of 50000 burning hours (L70B50) with CRI ≥80, SDCM<5 and Co-related color temperature (CCT) of 6500K.The luminaire must have 4KV surge protection integrated in driver, Ripple<5%,UGR<19, PF≥0.95, Total harmonic distortion THD≤10%, Test certificate and Bis certificate need to be submitted for approvals make PHILIPS, TYPE: RC380B LED36S-6500 G6 L60W60 PSU OD, HSN Code 9405 /equivalent | 4 | each | 9,000 ₹36,000 | 4,424.48 ₹17,697.92 Lowest | 4,572 ₹18,288 |
Tender Value
Refer Docs
EMD Value
₹16,525
Closing Date
26 Aug 2025, 6:00 pmClosed
AEE
PWD ESD KOZHIKODE
GENERAL-Budget 2023-2024-Construction of New Building for Narikkuni Ayurveda Hospital Pannikkottoor Kozhikode District-Electrification-General Electrical Work
2025_PWD_787895_1
PWD/BLDG/TR/14973/2025
Open Tender
Electrical Works
Item Rate
365 days
Narikkuni
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,460
₹16,525
4 Oct 2025
18 Aug 2025
29 Aug 2025
18 Aug 2025
26 Aug 2025
18 Aug 2025
Amount
Electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
OD117326/2025-2026:Supply and providing the following types and power rated lamps in the existing fittings as required9W LED bulb
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
OD117866/2025-2026:Supply and fixing LED bulk head (Philips WT140W Vistaglow or equivalent) fitting on wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
OD117871/2025-2026:Supply, Conveyance, installation, testing and commissioning of led surface mount fitting LED 600*600 mm(2ftx2ft) Luminaire having light output not less than 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) luminaire Housing Shall be made from single piece CRCA body without welding to avoid rusting and Prismatic diffuser to reduce glare. The Luminaire should be having minimum of 50000 burning hours (L70B50) with CRI ≥80, SDCM<5 and Co-related color temperature (CCT) of 6500K.The luminaire must have 4KV surge protection integrated in driver, Ripple<5%,UGR<19, PF≥0.95, Total harmonic distortion THD≤10%, Test certificate and Bis certificate need to be submitted for approvals make PHILIPS, TYPE: RC380B LED36S-6500 G6 L60W60 PSU OD, HSN Code 9405 /equivalent
OD117321/2025-2026:Supply, conveyance, installation, testing and commissioning of 1200 lumen(1x1) round/ square surface mount fitting made of diecast aluminium, having efficacy not less than 100l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea
90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD119498/2025-2026:Supply, fixing, testing & commissioning of LED Out door gate light fitting (LUKER make Helios Black Fixture (Big) - E27 Holder outdoor (Without Lamp ), Model : lgla7e27 bk) and giving connections etc. as required
OD119578/2025-2026: Supply, Conveyance, installation, testing and commissioning of 20W LED, E27 threaded type bulb in the existing gate light fittings having light output not less than 2000 Lumens with System efficacy > 100 Lumen/Watt ,White Bulb and giving connections etc. as required. make PHILIPS/techno commercial equivalent approved by Engineer in charge.
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD117317/2025-2026:Supply and providing every additional length of down rod of suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD117337/2025-2026:Supply, Conveyance, installation , testing and commissioning of 250mm sweep light duty exhaust fans in plastic body with self opening louvers in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
OD117336/2025-2026:Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS. - 300/ 305 mm, single phase light duty exhaust fan in metal frame.
1.22.4:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 150 mm X 60 mm deep
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
90.5.1.4:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Musical bell with bird sound
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.7:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 1.5 sq. mm
1.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.14:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm
OD122796/2025-2026:Supply and drawing following size of FRLS PVC insulated copper conductor ,Single core cable in the existing surface/recessed steel/PVC conduit as required 4*10 sq.mm
90.6.6.2:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.2.50 sq mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD117329/2025-2026:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 40/32 mm or nearest size
OD117348/2025-2026:Supplying and fixing 2P sheet steel enclosure suitable for fixing RCCB/Isolator on surface/ recess complete with all accessories,good the damages,colour washing etc. as required.
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
OD117323/2025-2026:Supplying and fixing 40 A to 63 A, TP MCB (C curve), 10 kA breaking capacity rating, 415 volts in the existing MCB DB complete with connections, testing and commissioning etc. as required.
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD117342/2025-2026:Supply and fixing cable junction box of size 167x125x82 mm IP 66 with metric knock outs, for fixing 3 way 16 A connector and 6A MCB and 32A Neutral link etc. and giving connections as required. Make Hensel / Equivalent
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD117322/2025-2026:Supply and providing 25x6mm brass nut and bolt etc. as required.
OD117320/2025-2026:Supply and providing 12x3mm brass nut and bolt etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD117319/2025-2026:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
OD117318/2025-2026:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD118813/2025-2026:Supply & installation of dust and vermin proof, 3 Phase Syntex Meter Board( GS-MB-6535) and to fix KSEB LT meters, TVM with CTs/DHD and fuse cut out etc as required including fixing it on wall, making good the damages colour washing etc. as required. 650*350*250mm
OD117316/2025-2026:Supply and providing and fixing 100A TPN disconnector fuse switch unit in sheet steel enclosure with ISI marked HRC fuses on wall/angle iron frame including drilling holes in frame, making connections, etc. as required.
OD117324/2025-2026:Supplying and fixing 100, HRC Fuse Base with HRC Fuse link with connections, in existing meter board
OD117325/2025-2026:Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD118814/2025-2026:Supply and providing suitable Iron Hook grouted on wall for binding the service wire as required.
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
OD124407/2025-2026:Supply, installation, Testing and commissioning of 3KVA/2.4KW UPS with isolation transformer, Including Racks, Breakers and Accessories. 3KVA/96V True online double conversion technology (VFI) assures high availability and total load protection, Advanced software for momitoring UPS,Automatic bypass supplies the loads in the event of overloads or faults. Single phase with IGBT based PWM technology and having the following minimum specification. 1.Output power factor-0.99 ,2.Input Voltage-230 V (1ph) 160-300 V up to 110 V @ 60% load 3. Output Voltage 208-240, 4.crest factor-3.1,5.Rating 3 KVA, 4.Noise level at 1 m-< 55 dBA,5. Display - Battery level / Battery status , Back time info , General Alarm d. Buzzer off , Load level /Load status , Input value , UPS mode , etc. Minimum 3 year on site warranty on UPS , having 2 Hours back up.Make-Socomec/Techno commercial equivalent approved by engineer in charge.
OD124413/2025-2026:Supply,Installation, Testing and Commisioning of Tubular Battery ,12V,60AH, for 2 hours backup, Including Dc cables battery inter links and battery racks. WARRANTY 3 YEARS Make: Exide/Quanta/Panasonic/Techno commercial equivalent approved by engineer in charge.
MOHANAN T (BID ID -2307310)
LUMEN ENGINEERING (BID ID -2303365)
Bidder Name
K MANOHARAN
LUMEN ENGINEERING
MOHANAN T
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1296319.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .