Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | ₹39.3 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹40.8 L+₹1.5 L (3.88%)Rejected-Finance | ₹40.8 L+₹1.5 L (3.88%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹43.0 L+₹3.7 L (9.42%)Rejected-Finance NIL | NA | NA | 121004 | ₹43.0 L+₹3.7 L (9.42%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹43.0 L+₹3.7 L (9.42%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹43.0 L+₹3.7 L (9.42%) | L4 | Rejected-Finance Other than L1 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
21 Aug 2023, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
SPL REPAIR TO BER CEILING FAN, EXHAUST FAN AND OTHER REV/ MINOR WORKS AT NAA UNDER GE (NORTH) TEZPUR
2023_MES_609790_1
GE(N)/TEZ/2023-2024/8735
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (NORTH) TEZPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹93,000
29 Sept 2023
19 Jul 2023
28 Aug 2023
19 Jul 2023
21 Aug 2023
2 Aug 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M & L for rendering/plastering 15 mm thick in cement mortar 1:6 on faces of brick or concrete surfaces and finished the surface even and smooth without using extra cement complete in all respect as specifified and directed.
M & L for rendering 15mm thick cement plaster in cm 1:4 on fair faces brick or concrete surfaces using water proofing compound of wall (WPC added only 5 mm thick plaster) including finished even and smooth without using extra cement complete all as specified and as directed.(WPC Shall be paid and meassured separately)
Supply only integral water proofing compound complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M & L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M&L for preparation of new plastered or undecorated surfaces of wall using wall care putty to fill the voids and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based trapezoid profile steel sheet 0.50 mm thick of and colour having tensile strengh of 550 Mpa as in ridge, eaves sheet/board covering, valley gutter or of similar type, fixed with self tapping screws with bitumen washer to truss members of any material, complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality "A") complete all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45⁰ angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
S & F 75 mm size butt hinges, extruded aluminium alloy with brass wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 125A22 as per IS 205: 1992 complete all as specified and as directed.
S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. Make Jaquar, cat aprt No AEC 1111, Make Hindware Cat part No F450024
S & F aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F mild steel sliding door bolts, type I (plate type), size 300 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection/paving finish all as specified and as directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed.
M & L for coloured non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement with pigment to match the tile colour complete in all respect as specified and directed.
M&L for coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile colour complete in all respect as specified and directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair without using extra cement including necessary expansion joint and filling compound as in plinth protection all as specified and as directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S&F framed work such as grills, gratings,etc with ends of bars shouldered and /or riveted, or forged into spikes framed guard bars barred iron doors , laddersand similar work conforming to Fe 410-0 or FE310-0 complete all as specified and directed.
S&F of CP two way bib tap with health faucet 15mm dia fancy type with 1.00 mtr tube and hook (braded tube) complete all as specified and directed
S & F wash hand basins, vitreous china of size 550 x400mm(flat back or angle back type), including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32mm dia bore waste fitings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement, PVC waste pipe including 15mm bore dia fancy type CP finish Pillar tap, cast copper alloy with capstan heads, screwed down high presuure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron/CPVC pipe/fittings complete all as specified and directed.
S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed.
S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed.
S & F UPVC (SWR) bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
S & F UPVC (SWR) bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and as directed.
Supplying & laying in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge. (MAKE : PRAYAG, Cat No: 152 or equivalent model in JEXON / POLYTUF / SHAKTI)
S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with brass chromium plated bracket guard and railing 60 cm long complete in all respect as specified and directed.
S & F wash hand basins, vitreous china of size 550 x400mm(flat back or angle back type), including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32mm dia bore waste fitings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement, PVC waste pipe including 15mm bore dia fancy type CP finish Pillar tap, cast copper alloy with capstan heads, screwed down high presuure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron/CPVC pipe/fittings complete all as specified and directed.
S & F PTMT ball valve high pressure 20mm bore with epoxy coated aluminium rod & high density plastic ball screwed for iron/CPVC pipe/fittings complete all as specified and directed.
S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, nickel-chromium plated finished complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F vitreous china wash down water closet Pan (pedestal pattern) white including plastic water closet seat cover, white, closed pattern with flat bottom, and mild steel chromium plated hinging device (exclusive flushing cistern and flush pipe) complete all as specified and directed.
S & F toilet paper holder of vitreous china, box type, white fixed to walls with chromium plated brass screws complete all as specified and as directed.
M & L for liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 105 gms) complete all as specified and as directed.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC Type A-1 1:1.5:3 Mix Baffle walls and Roof Slab including beams etc with Vent shaft,manhole openings with cover connection etc for 05 users capacity all as per Drawing available with sub division complete all as specified and directed.
M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in Type A-1 1:1.5:3 cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia and 3.0m depth complete all as specified and directed.
M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring jointslaying in trenches 150 mm bore complete in all respect as specified and directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M & L for cement concrete in surface channels and drains in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer- in-charge.
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed
S & F PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed.
S & F UPVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed.
Supply and fix energy saving ceiling fan 1200 mm sweep, BEE 5 star rated (BLDC),without remote , minimum air delivery 228 cmm , working voltage 140 volt to 270 volt , minimum rpm 350 , ISI marked , including necessary hanging arrangement , providing three core flexible copper conductor wire of size 23/0.0076 from ceiling rose to fan complete all as directed by Engr-in-Charge.(Make:- Orient I series Hector 500)
Supply and fix energy saving ceiling fan 1200 mm sweep, BEE 5 star rated (BLDC decorative type),with remote , minimum air delivery 228 cmm , working voltage 140 volt to 270 volt , minimum rpm 350 , ISI marked , including necessary hanging arrangement , providing three core flexible copper conductor wire of size 23/0.0076 from ceiling rose to fan complete all as directed by Engr-in-Charge.(Make:- Orient Aero series Aeroquiet)
Supply and fix energy saving ceiling fan 1400 mm sweep, BEE 5 star rated (BLDC),without remote control , ISI marked , including necessary hanging arrangement , providing three core flexible copper conductor wire of size 23/0.0076 from ceiling rose to fan complete all as directed by Engr-in-Charge.(Make:- Orient I series Hector 500)
Supply and fix exhaust fan 300 mm sweep, 1400 rpm ISI marked with metal blade and louver complete fixed in wall with fastener complete all as directed by Engr-in-Charge. (Make:- USHA S.PH Turbo HDEF 1400 RPM ISI)
Supply and fix exhaust fan 450 mm sweep, 1400 rpm ISI marked with metal blade and louver complete fixed in wall with fastener complete all as directed by Engr-in-Charge. (Make:- USHA S.PH Turbo HDEF 1400 RPM ISI)
Supply and fix ventilating fan 250 mm sweep, ISI marked with plastic body fixed in wall with fastener complete all as directed by Engr-in-Charge. (Make:- USHA CRISP AIR)
Supply, installation, testing & commissioning as in replacement of 1 phase, 2 wire, single source, direct connected prepaid key pad based BIS Marked IS-15884 Digital Prepaid Energy Meter, 10-60 Amps, 240 Volts, accuracy class-1.0 alongwith parallel Consumer Interface Unit and Soft Token Transfer Device at houses, with Poly Carbonate meter box with facility of meter to generate ABC Code ( Authenticated Billing Code) for Monthly Energy usage Bill Generation,having LCD type display, calliberation LED, numeric key pad for token entry with RS 232 communication port, LED for credit status indication, push button for scroll and having features for load disconnection in case the credit limit become zero or increase of load than permissible limit, reconnection and disconnection of load, buzzer at Consumer Interface Unit to give alarm in case of low credit and overloading and data download port for last 25 days (min) temper event and load survey for last 45 days with all standard anti temper features including sealing facility all as specified and directed by Engr-in charge. Make- HPL cat part No. PSPB1523111000OC01 or equivalent in (i) L&T (ii) Schnieder Note:- Cost of connecting to existing system and and others connected item including 2 pair, 0.5 mm Annealed Cu connecting wire RJ-11 to connection between meter and consumer interface unit, termination connector for 2 pair wire meter and CIU each set and cost of disconnetion of old existing meters of any size and deposit at E/M store is included in the quoted rate is deemed to be included in the rates quoted.
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 150 mm bore complete all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 70 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supplying & laying 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth strip size of 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion, complete all as specified and directed.
M&L in Thermoplastic Cable Junction Boxes IP66/67 "weather proof", for outdoor installation with knockouts for cable entry with terminals suitable for 10-16sqmm cable of Size 155 x 210 x 92 mm incl busbar mounted on insulator and MCB SP 6 Amps-1 No, including necessary civil works and connecting all incoming and outgoing wires with AL lugs of appropiate sizes and complete all as specified and directed
S&F 1100 volts grade PVC insulated weather proof sheathed copper cable 1.5 sqmm size 3 core fixed with RCC/Steel tubular pole including PVC conduit medium grade 19/20 mm dia complete all as specified and directed.
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness size not less than (1.6x0.6x1.6)m, angle iron of size 40X40X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Cu bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 250 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 160 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 125Amps, 25 kA for out going -01 No MCCB 4 pole, 415 Volts,63 Amps, 25 kA for out going -04 Nos
Supply, install, testing & commissioning of LT busbar chamber of size (0.60x0.60x0.60)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Cu bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos copper 400 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos. NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply, install, testing & commissioning of LT busbar chamber of size (0.60x0.60x0.60)m CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick of length 0.6 m from pcc, frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Cu bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete including PCC foundation comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos copper 200 A rated duly insulated with 1100 V grade standard colour coded PVC sleeves PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INSTRUMENTATION SYSTEM : (a) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set. (b) 3 Ph Digital Voltmeter CI 1.0 - 01 No (c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 - 01 Nos. NOTE : 1) Design / Drawing / BOM of the LT Busbar panel board showing the dimensions incl accessories is to be obtained from panel board manufacturer / supplier & is to be got approved from GE before placing final order to the manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
M & L for point wiring with 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including sunken in cast iron/MS terminal box duly painted with aluminum paint inside and anticorrosive paint out side with 2.8 mm thick backlite hylem sheet cover, ISI for fan/light/exhaust fan/bell point controlled by one switch. Note:- 1. M&L for cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.
All as per item 106 above but for One 3 pin socket outlet 5 Amps on indpendent board complete all as specified and as directed.
All as per item No. 106 here-in- before but for 3 pin 16 Amps switch socket combination on independent board with 4.0 sq mm copper cable.
S & F switch socket combination out let 2 in one/3 pin , 5/6 Amps, flush type 240 volt , AC 50 Hz complete all as specified and directed. (Make :- Havells Cat no/SAP code - AHETOXG202 or equivalent in Legrand / Schneider)”
S & F switch socket combination out let 2 in one/6 pin , 6/16 Amps, flush type 240 volt , AC 50 Hz complete all as specified and directed. (Make :- Havells Cat no/SAP code - AHETOFG202 or equivalent in Legrand / Schneider
S & F switch piano 5/6A one way ,240 volt , AC , 50 Hz flush type complete all as specified and directed.(Make - Havells Cat no/SAP code:- AHESEXW061 of REO or equivalent in Legrand/schneider
S & F lamp holder (Angle Holder), PVC/Polycarbonate type with cord grip cap suitable for pendent fitting complete all as specified.(Make :- Havells Cat no/SAP code – AHEHQMW000 or equivalent in Legrand / Schneider)
S & F LED bulb 10 watt B22 type emergency inverter type rechargable(4 hr backup) with lumen output 950 lm and color temp 6500K suitable for bulb holder complete all as specified and diirected.(Make :- Philips model Stellarbright or equivalent in Wipro / Crompton)
S & F ceiling rose 6A ,240 volt , surface type , intended to support mechanical load by means of flexible coard having provision for the connectionof switch wiring , polycarbonate type three terminals complete all as specified and directed.(Make :- Havells Cat no/SAP code – AHEEUXW002 or equivalent in Legrand / Schneider)
S&F in replacement LED Tube light luminaires, 22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of from connector and ceiling rose, complete all as specified and directed. (Make :- Philips model SmartBright or equivalent in Wipro / Crompton)
Supply and fixing mirror light batten type 1x10 watt , 240 Volt AC . 50 Hz complete all as specified and directed .(Make :- Philips model SmartBright or equivalent in Wipro / Crompton)
Supply & fix exhaust fans AC single phase 230/ 240 V of size 230 mm sweep , metal body , 900 rpm light duty with louve, cutting , making hole complete all as specified and directed.
M&L for sheet metal enclosure MCB DBs SPN , 4 way 240 V, with 100 A rated copper bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. (Make:- Legrand series 5076 10 to 15 or equivalent in L & T / Schnieder)
M & L for MCB SPN 32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4086 17 or equivalent in L & T / Schnieder)
M & L for MCB SP 6-32 Amps, 240 volts , 10 kA ISI marked as per IS/IEC 60898-1 2002 , C -curve , IP 20 complete all as specified and directed.(Make :- Legrand series 4085 87 to 4085 95 or equivalent in L & T / Schnieder)
Supply and draw submain wiring with two single core 4 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in PVC casing capping including 4 sq mm multi-strand FRLSH PVC insulated copper wire for earth continuity conductor connected to common earth dolly including necessary fittings & fixtures and including PVC terminal box and PVC board making good disturbed surface with CM (1:4) to match with the existing surface complete and making good disturbed surface complete. Note:- Cost of PVC conduit and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 15 KVA .
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 30 KVA .
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 kVA complete all as specified and directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 50 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
Supplying & laying in trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Material and labour for fixing GM globe/gate/ball valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS complete all as specified and directed by Engr in charge. Note: Union or long screw have to provided before fixing of gate valve if required.
Material and labour for fixing GM globe/gate/ball valve 25 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS complete all as specified and directed by Engr in charge. Note: Union or long screw have to provided before fixing of gate valve
Cutting and insertion existing GI/DI/CI/PP-R pipe/tubing of size 50-110 mm bore for branch connections including all fittings(CI/DI/PP-R) like Tee , reducer , Tee reducer (any type or any size as required at site) complete all as specified and directed.
M/S JIWA SINGH S GILL
MD. LATIFUL AHMED HUSSAIN
PURBANCHAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .