Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | ₹29.6 L Quoted ₹30.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹30.9 LRejected-Finance 17 1305 ARIAKATTU PALLURUTHY KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | ₹30.9 L | L2 | Rejected-Finance Rejected due to not being L1 |
| 3 | L3₹31.9 LRejected-Finance NO 9 82 IB CHAKKALAKAL SOUTH CHITTOOR P O ERNAKULAM DIST KOCHI 682 027 | KOCHI | ERNAKULAM | KERALA | 682027 | ₹31.9 L | L3 | Rejected-Finance Rejected due to not being L1 |
| 4 | L4₹32.1 LRejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | ₹32.1 L | L4 | Rejected-Finance Rejected due to not being L1 |
| 5 | L5₹32.7 LRejected-Finance | ₹32.7 L | L5 | Rejected-Finance Rejected due to not being L1 |
| Sl No | Description | Qty | Unit | Oriental Constructions L1 | ANIE JOHN CONTRACTORS L4 | SUKU CONSTRUCTIONS L6 | kanjirathingal builders L5 | AS ENTERPRISES L7 | HEAVEN ENGINEERS AND CONTRACTORS L2 | S&C ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Opening/Lifting of man hole cover and taking out waste soil, sludge, other sediments, solid waste, and liquid waste from manhole, up to depth of manhole 1.5m in any condition and refix the man hole cover on completion of work, complete all as specified and as directed by Engineer In Charge.
Note:- (a) The night soil, other sediments and liquid waste in any condition removed from manholes shall be taken away from respective vicinities and Premises on closed containers/conveyance and disposed off out of defence land
(b) Disposal of the same shall be the responsibility of the contractor without any extra expenditure to the government. Disposal of waste shall be made in accordance with the regulations of the municipal authorities concerned. | 235 | Each | 110 ₹25,850 | 30 ₹7,050 | 250 ₹58,750 | 50 ₹11,750 | 130 ₹30,550 | 90 ₹21,150 | 80 ₹18,800 |
| 2.00 | All as per Item No 1 above but for manhole of depth exc 1.50m not exc 3.00m and any width complete all as specified and as directed. | 80 | Each | 140 ₹11,200 | 30 ₹2,400 | 250 ₹20,000 | 60 ₹4,800 | 185 ₹14,800 | 103 ₹8,240 | 100 ₹8,000 |
| 3.00 | Cleaning by roding or with bamboo and taking out waste soil , silt, sludge and other foregin materials from sewage lines/effluent drains below /above GL of 100 dia of pipe ,removed all waste in sealed container as mentioned in item No 1 above including taking precautionary and safety measures complete all as specified and as directed. | 440 | RM | 30 ₹13,200 | 10 ₹4,400 | 15 ₹6,600 | 20 ₹8,800 | 35 ₹15,400 | 9.9 ₹4,356 | 30 ₹13,200 |
| 4.00 | All as per Item No 3 above but cleaning of sewage lines/effluent drains 150 mm dia below/above GL complete all as specified and as directed. | 410 | RM | 35 ₹14,350 | 12 ₹4,920 | 20 ₹8,200 | 25 ₹10,250 | 35 ₹14,350 | 10 ₹4,100 | 40 ₹16,400 |
| 5.00 | M&L pumping out sludge water from septic tanks and sumls by mechanical means for cleaning and removing the sludge and burying the waste material in borrow pits complete all as specified and as directed by Engr-in-Chrge. Note:- (Cost of the borrow pit shall be deemed to be included in the quoted rates of this item) | 103 | Cum | 240 ₹24,720 | 200 ₹20,600 | 1,200 ₹1.2 L | 250 ₹25,750 | 285 ₹29,355 | 325 ₹33,475 | 200 ₹20,600 |
| 6.00 | Removing the choked WC/bathroom/kitchen traps/drain pipes etc up to Ist manholes including cleaning of gully traps in single storied and including multistoried bldgs complete all as specified and as directed. | 1,019 | Per choke | 60 ₹61,140 | 30 ₹30,570 | 80 ₹81,520 | 50 ₹50,950 | 55 ₹56,045 | 50 ₹50,950 | 60 ₹61,140 |
| 7.00 | Cleaning of covered drain and removal of silt and disposed off inclcomplete all as specified and as directed by Engr-in-Charge.
Note : Including Removal and refixing of drain RCC drain covers complete as per original position no extra payment on this account Cleaning of covered drains of any depth/width after removal of RCC cover slab and refixing the same in position after cleaning and removal of silt to a distance exceeding 100m and not exceeding 1500m complete all as specified and directed
Note:
1.Cleaning to be done pre monsoon and post monsoon as per site requirement and shall be measured seperatly all as specified and as directed by Engineer In Charge.
2.Removing and refixing of drain cover and setting in CM 1:4 shall be inclusive of the quoted rate | 543 | RM | 90 ₹48,870 | 20 ₹10,860 | 200 ₹1.1 L | 50 ₹27,150 | 180 ₹97,740 | 20 ₹10,860 | 70 ₹38,010 |
| 8.00 | Cleaning of PVC/CI rain pipe/soil waste pipe of any dia by rodding or with bamboo split including taking down inspection eye door cover and refixing inspection eye cover in existing position etc complete all as specified and as directed. | 130 | Rm | 18 ₹2,340 | 30 ₹3,900 | 30 ₹3,900 | 25 ₹3,250 | 18 ₹2,340 | 9 ₹1,170 | 20 ₹2,600 |
| 9.00 | Pumping out sewage water from the man holes / septic tank / soakage well at different locations by means of sewage tanker fitted with pump (5000 ltr capacity) and disposing off out of MD land as directed by Engr-in-charge .
Note:-(For ser item No.1 to 8 above)
(i) Contractor's supervisor has to collect complaint slip from AGE B/R-I office on all working days. The complaints has to be attended and submit the slip duly signed by the user on the same dayby 1700 hrs to the Office.
(ii) If the contractor fail to attend the complaint, recovery @ Rs. 500 per day per complaint shall be effected from the amount due to the contractor.
(iii) If there is any major blockage in sewage line/Septic tank or any emergency situation immediate service has to be provided by the Contractor even in holidays without any extra cost. | 15 | Each tank of 5000 ltr | 2,500 ₹37,500 | 2,000 ₹30,000 | 6,500 ₹97,500 | 1,500 ₹22,500 | 3,000 ₹45,000 | 950 ₹14,250 | 2,000 ₹30,000 |
| 10.00 | M&L for On site 20 users Hume Pipe septic tank designed to carry sewage and sullage water, including excavation in any type of soil, 150mm thick PCC 1:4:8 below foundation bed, vent shaft, connection etc of inlet and outlet, complete all as specified and as directed by Engineer-in-charge. | 1 | Each | 20,000 ₹20,000 | 20,000 ₹20,000 | 22,000 ₹22,000 | 20,000 ₹20,000 | 45,000 ₹45,000 | 18,000 ₹18,000 | 21,000 ₹21,000 |
Updated dates
Tender Value
₹48.9 L
EMD Value
₹97,800
Closing Date
13 Nov 2025, 6:00 pmClosed
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2025_MES_735495_1
8513_GE_NW
Open Tender
Civil Works
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹97,800
4 Apr 2026
16 Oct 2025
17 Nov 2025
16 Oct 2025
13 Nov 2025
31 Oct 2025
16 Oct 2025 - 31 Oct 2025
Amount
Opening/Lifting of man hole cover and taking out waste soil, sludge, other sediments, solid waste, and liquid waste from manhole, up to depth of manhole 1.5m in any condition and refix the man hole cover on completion of work, complete all as specified and as directed by Engineer In Charge. Note:- (a) The night soil, other sediments and liquid waste in any condition removed from manholes shall be taken away from respective vicinities and Premises on closed containers/conveyance and disposed off out of defence land (b) Disposal of the same shall be the responsibility of the contractor without any extra expenditure to the government. Disposal of waste shall be made in accordance with the regulations of the municipal authorities concerned.
All as per Item No 1 above but for manhole of depth exc 1.50m not exc 3.00m and any width complete all as specified and as directed.
Cleaning by roding or with bamboo and taking out waste soil , silt, sludge and other foregin materials from sewage lines/effluent drains below /above GL of 100 dia of pipe ,removed all waste in sealed container as mentioned in item No 1 above including taking precautionary and safety measures complete all as specified and as directed.
All as per Item No 3 above but cleaning of sewage lines/effluent drains 150 mm dia below/above GL complete all as specified and as directed.
Removing the choked WC/bathroom/kitchen traps/drain pipes etc up to Ist manholes including cleaning of gully traps in single storied and including multistoried bldgs complete all as specified and as directed.
Cleaning of PVC/CI rain pipe/soil waste pipe of any dia by rodding or with bamboo split including taking down inspection eye door cover and refixing inspection eye cover in existing position etc complete all as specified and as directed.
Pumping out sewage water from the man holes / septic tank / soakage well at different locations by means of sewage tanker fitted with pump (5000 ltr capacity) and disposing off out of MD land as directed by Engr-in-charge . Note:-(For ser item No.1 to 8 above) (i) Contractor's supervisor has to collect complaint slip from AGE B/R-I office on all working days. The complaints has to be attended and submit the slip duly signed by the user on the same dayby 1700 hrs to the Office. (ii) If the contractor fail to attend the complaint, recovery @ Rs. 500 per day per complaint shall be effected from the amount due to the contractor. (iii) If there is any major blockage in sewage line/Septic tank or any emergency situation immediate service has to be provided by the Contractor even in holidays without any extra cost.
M&L for On site 20 users Hume Pipe septic tank designed to carry sewage and sullage water, including excavation in any type of soil, 150mm thick PCC 1:4:8 below foundation bed, vent shaft, connection etc of inlet and outlet, complete all as specified and as directed by Engineer-in-charge.
S&F EURO GUARD PRO SQUARE UPVC RAINWATER GUTTER (220 MM), with all necessary fittings, clamp, joints, end cap, corner drop, centre drop, etc joining compounds, nut, bolts or screws etc and fixing in position, at any height including taking down eaves gutters and rain water pipes complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls (jointing to be done with solvent cement) including taking down pipes complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bend any radius complete all as specified and as directed.
Demolition of block masonary built in cement mortar including all quoins, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, Type C1, 1:3:6 (using 20mm graded stone aggregate), complete all as specified and directed.
M&L for rendering 15mm thick on brick or concrete wall surfaces with cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and as directed.
Ditto all as per item No 17 above but using extra cement as in manholes, etc complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water any description, etc. complete all as specified and directed.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 100mm thick PCC type B 2 1:2:4 (using 40mm graded aggregate ) as in pavement,sub base and flooring etc.finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 40mm thick PCC type B1 1:2:4 (using 20mm graded aggregate ) as in repair top surface of pavement and flooring etc. and surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 75mm thick cement concrete type C2 1:3:6 (40mm graded aggregate) as in plinth protection complete all as specified and as directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work of concrete complete all as specified and directed.
M&L for cement concrete ( 1:3:6 ) type C1 (using 20 mm graded stone aggregate) as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement and necessary form work complete all as specified and as directed. (Note : Forming fair finished channel for drain using extra cement will be measured and paid for separately.)
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
Dismantling fencing wire mesh, any type including mild steel deformed bars in any size complete all as specified and as directed.
Dismantling post or sturt (wood, steel or RCC any section) including taking out embedded portion in concrete, brick work etc complete all as specified and as directed.
S&F MS post and struts in fencing including cutting tops to shape as directed drilling holes, notching for wire etc. Flat iron fillets (for securing wire mesh etc) incl all necessary drilling bolting or revetting etxc and similar work confirm complete all as specified and as directed.
M&L for cement concrete in post holes foundation fillings and mass concreting PCC 1:3:6 type C2 (using 40mm graded stone aggregate) complete all as specified and as directed.
S&F in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
S&F MS galvanised chain link fencing of grid size 50x50x3.10mm dia wire (Weight not less than 3.25 Kg/Sqm including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
M&L for mild steel round bars 10mm dia and over cut to length, bent to shap required including cranking, bending spirally for hooping for as in line wire for straining fencing and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips incl removal of old one complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete qulity A complete all as specified and as directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for welding in repairs exc 2.5cm but n.exc 5cm in length of welding and n.exc 6mm thickness of metal including cleaning and preparing the steel surfaces to be welded together, holding the members like windows, railings, guard bars etc. in true position while welding and bevelling of edges, as required complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of anti corrosive paint over a coat of appropriate primer complete all as specified and as directed.
M&L for complete removal of existing treatment on old plastered wall surfaces and application of two coats of cement based paint over a coat of chalk whiting all as specified and directed.
M&L for preparation of old plastered wall surfaces and application of one coats of cement based paint complete all as specified and as directed.
M&L for 20mm thick screed bed or bedding layer in cement 1:6 on floors for laying floor finish complete all as specified and as directed.
M&L for 300x300x10mm thick parking tiles, set and jointed and pointed in neat cement slurry with grey cement and pigment in floors complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floor with grey cement and filling joints with colour pigment over and including 20 mm thick screed bed in cement mortar 1:6 including dismantling of old tiles complete all as specified and as directed.
M&L for coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm spreading and levelling in layers complete all as specified and as directed.
Dismantling stone slabs laid dry or laid dry and pointed and tiles of any description or thickness in floors, aprons etc. complete all as specified and as directed.
Material and labour for machine pressed precast concrete interlocking paver block any shape and size as approved confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed.
All as per item No 46 here-in-before but except machine pressed precast interlocking paver block complete all as specified and as directed. Note: The paver block obtained vide item No.46 above shall be re-used.
M&L for mild steel TMT bars 5mm to 10mm dia cut to length, bent to shap required including cranking, bending spirally, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 5mm dia and over and including 10mm dia in stirrups, spacers and binders etc , cut to length, bent to shape required, including cranking bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for providing precast cement concrete Type B1 1:2:4 (20mm graded stone aggregate) in drain/manhole cover slabs and similar articles with plain faces and setting in cement mortar 1:4 with joints to match complete including necessary form work complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling, mass concrete, sub base or leveling coarse of floor etc. complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth for foundation, man holes etc and getting out in soft/loose soil complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) set in cement mortar 150 mm internal dia complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) set in cement mortar 100 mm internal dia complete all as specified and directed.
M&L for 150 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for concrete bed to drain pipes 150 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 Type C-2 complete all as specified and directed.
M&L for concrete bed to drain pipes 100 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 Type C-2 complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25cm thick (Soft/loose soil) complete all as specified and as directed.
Removing excavated material exc. 50m and n.exc 100m depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting any gauge, thickness including nainital or similar pattern roof covering complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F roof trusses (framed) confirming to Fe 410W, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
Opening/Lifting of man hole cover and taking out waste soil, sludge, other sediments, solid waste, and liquid waste from septic tank/soak well/manhole in connection with septic tank in any condition and refix the man hole cover on completion of work, complete all as specified and as directed by Engineer-in-Charge. Note:- (a) The night soil, other sediments, solid waste, and liquid waste in any condition removed from manholes shall be taken away from respective vicinities and premises on closed containers/conveyance and disposed off out of defence land. (b) Disposal of the same shall be the responsibility of the contractor without any extra expenditure to the government. Disposal of waste shall be made in accordance with the regulations of the municipal authorities concerned. c) The unit rate quoted shall be deemed to be inclusive of cleaning the neared MH & sewage line from that MH to septic tank.
M&L for destruction of growth of weed plants with roots on the roof of bldgs and on the wall of bldgs at any height with 2.40 'D' oil mixed veedicides or mixed with veedol chemical solution and sprayed in and around roots and at places of possible growth of weeds all as directed by the Engineer-in-charge. Note:-(i) In case of plants that has trees like growth, the plant should be cut to avoid damages to roof/wall and rest to be treated with chemical solution (ii) The area after treatment shall be cleaned off all debris branches dead plant, (iii) Rate incl Height upto 12 storey building ,incl necessary scafolding seafty arragements etc.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete as specified as directed.
M&L for brickwork built in cement mortar (1:4) with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius complete as specified and directed.
S&F in repair 100 mm dia cast iron branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with cement joints upto 4th storey complete as specified and directed.
S&F in repair 75 mm dia cast iron branch piece single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches upto 4th storey building complete as specified and directed.
S&F in repair cast iron 100 mm dia soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed on wall complete as specified and directed.
S&F in repair cast iron 75 mm dia soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed on wall complete as specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls complete all as specified and directed.
S&F 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls complete all as specified and directed.
S&F in repair PVC (SWR) floor trap 75 mm dia plain with grating including jointining with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) junction single (single T ) equal or unequal provided with access door for 75 mm dia pipe including jointining with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) junction single (single T ) equal or unequal provided with access door for 110 mm dia pipe including jointining with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 75 mm dia including jointining with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 110 mm dia including jointining with solvent cement complete all as specified and directed.
S&F in repair bends cast iron any radius 100 mm bore diminshing pieces or tapers (large bore measured) including jointining with solvent cement complete all as specified and directed.
S&F in repair bends cast iron any radius 75 mm bore diminshing pieces or tapers (large bore measured) including jointining with solvent cement complete all as specified and directed.
S&F in repair cover of CI oval access door with bolts and rubber gasket to make it water tight for 100 mm bore CI bends complete all as specified and directed.
S&F in repair cover of CI oval access door with bolts and rubber gasket to make it water tight for 75 mm bore CI bends complete all as specified and directed.
S&F in repair cast iron 100 mm dia soil, waste and vent pipes, in any length with or without ears, with cement joints , laid in trenches or in floor complete all as specified and directed.
S&F in repair cast iron 75 mm dia soil, waste and vent pipes, in any length with or without ears, with cement joints , laid in trenches or in floor complete all as specified and directed.
S&F in repair 110 mm dia PVC (SWR) branch piece single (single Y ) (equal or unequal) ordinary or inverted (spigot or socket type ) or with parallel branch up to 4 th storey complete all as specified and directed.
S&F in repairs 75 mm dia PVC (SWR) branch piece , single (single Y) (equal or unequal ) ordinary or inverted (Spigot or socket type ) or with parallel branches up to 4th storey complete all as specified and directed.
M&L for cutting into the manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete (1:2:4) type B1 smooth finished , and reforming benching as required of 150 mm bore complete all as specified and directed.
M&L for plain cement concrete 75mm thick type D -2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for coarse aggregate nominal size 6.3mm and below as in paving under floor spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required complete all as specified and directed.
Material and labour for machine pressed precast concrete interlocking paver block any shape and size as approved confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and as directed.
M&L for rough formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
M&L for rough formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for RCC 1:1.5:3 nominal mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC 1:1.5:3 nominal mix as in beams, cantilevers, bressummers, lintels complete all as specified and as directed.
M&L for RCC 1:1.5:3 nominal mix as in columns, pillars, piers, posts and struts complete all as specified and as directed.
HEAVEN ENGINEERS AND CONTRACTORS (BID ID -3467878)
S&C ENTERPRISES (BID ID -3468634)
ANIE JOHN CONTRACTORS (BID ID -3467979)
kanjirathingal builders (BID ID -3467445)
SUKU CONSTRUCTIONS (BID ID -3472622)
AS ENTERPRISES (BID ID -3468397)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.34 MB
PS8513.pdf
Additional Documents • 0.34 MB
Testing.pdf
Additional Documents • 0.40 MB
BOQ_823597.xls
BOQ • 0.35 MB
Tender8513.pdf
Tender Documents • 0.64 MB
Download all tender documents and submit your bid