Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹5.3 LAccepted-AOC NELLIMOOTTIL THOTTUVA MANAKKALA P O ADOOR | l1 | Accepted-AOC l1 | |
| 2 | l2₹5.5 L+₹22,820.56 (4.29%)Rejected-AOC ORIYARA HOUSE MAVILAKADAPURAM KASARAGOD PIN 671312 | KASARAGOD | KERALA | 671312 | l2 | Rejected-AOC l2 |
Tender Value
₹5.3 L
EMD Value
₹13,320
Closing Date
28 Nov 2019, 6:00 pmClosed
Assistant Engineer
O/o of the Assistant Engineer , LSGD Engineering Wing Adoor Municipality.
Construction of Culvert in Kochu Kaleekkal Road Ward 6 Project # 165 in Adoor Municipality multiyear project
2019_LSGD_322056_4
P1/4561/19 sec
Open Tender
Civil Works - Roads
Item Rate
600 days
adoor
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,066
Yes
online
₹13,320
Yes
29 Jan 2020
20 Nov 2019
30 Nov 2019
20 Nov 2019
28 Nov 2019
20 Nov 2019
Amount
box culvert
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
od293409/2019_2020 : Engaging man coolie
od293221/2019_2020 : DRY RUBBLE MASONARY - Dry Rubble without Concrete levelling course masonary with good quality<br>blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials<br>, Labour charges etc complete asper direction of Departmental officers at site.<br>
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
od293320/2019_2020 : Filling with contractor own earth ( excluding Rock ) in open areas in layers not exceeding 20cm in depth consolidating layer by ramming and watering lead uptp 50 m and lift upto 1.5m as per direction of site Engineer in charge
od293277/2019_2020 : Fiilling with Quarry muck . Filling up Low lying and water logged areas with local<br>material / quarry muck spreading in layers levelling the top at site and consolidation by ramming etc .<br>
od293279/2019_2020 : Construction of un-reinforced plain cement concrete pavement ,thickness as per<br>design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 30<br>(grade),coarse and fine aggregates conforming to IS 383,maximum size of coarse aggregate not exceeding<br>25 mm,mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using<br>approved mix design,laid in approved fixed side formwork,spreading the concrete with<br>showels,rakes,compacted using needle vibrators and finished in continuous operation including provision<br>of contraction and expansion ,construction joints,curing of concrete slabs for 14 days, and water finishing to<br>lines and grade as per drawing and Technical Specifications clause 1501
od293347/2019_2020 : Surface dressing of the ground including removing vegetation and in equalities not<br>exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m, All kinds of soil<br>
od293318/2019_2020 : Irish Drain - Construction of plain cement concrete pavement thickness asper design<br>over a prepared sub base with 43 grade cement or any other type asper clause 1501.2.2 M30 ( Grade ) Coarse<br>and fine aggregates confirming to IS 383 maximun size coarse aggregate not exceeding 25 mm mixed in a<br>concrete mixer of not less than 0.2 m3 capacity and appropriate weight batcher using approved mix design<br>laid in approved fixed side form work wedges steel plates including levelling the form work spreding the<br>concrete compacted using needle vibrators and finished in continuous operation including provision of<br>curing of concrete slabs for 14 days and water finishing to lines and grade asper drawing and Technical<br>specification Clause 1501 without form Work.
12.3 : Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
od278412/2019_2020 : Supplying and fixing nameboard of size 75x60cm installed in appropriate place visible to public made of brick wall with granite plaque should be inserted and engraving letters etc complete as direction of deptl officers at site<br>
10.15 : Tubular Steel Railing on Precast RCC posts, 1.2 m high above Ground LevelProviding, fencing and erecting 50 mm dia painted steel pipe railing in 3 rows on precast M-20 grade RCC vertical posts 175 mm x 175 mm x 1.8 m high (1.2 m above Gl) with 3 holes 50 mm dia for pipe, fixed 2 m centre-to- centre complete as per approved drawings Clause 1706
Rajesh K
Bidder Name
RAY THOMAS
Rajesh K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .