| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC AIR FORCE ROAD NEAR BRIDGE OPP KHETIWADI RAJIV NAGAR JAMNAGAR 361002 | JAMNAGAR | JAMNAGAR | GUJARAT | 361002 | L1 | Accepted-AOC Accepted for acceptance being lowest. | |
| 2 | L2₹21.7 L+₹1.9 L (9.78%)Rejected-Finance 05 AYODHYA NAGAR NEAR RAM MANDIR BEHIND HARIYA COLLEGE GOKUL NAGAR JAMNAGAR 361004 | JAMNAGAR | JAMNAGAR | GUJARAT | 361004 | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹23.5 L+₹3.8 L (19.0%)Rejected-Finance | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹28.0 L+₹8.2 L (41.6%)Rejected-Finance | L4 | Rejected-Finance Not L1. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Jul 2023, 6:00 pmClosed
GE (AF) JAMNAGAR NO 2
AIRFORCE 2 JAMNAGAR
CLEANING AND MAINTENANCE OF SEWAGE LINES, REPAIRS TO DRAINAGE SYSTEM, CULVERT, HARDSTANDING, FLOOR, PATH, FENCING AND OTHER MISC B/R REPAIR WORKS AT AF-II UNDER GE (AF) JAMNAGAR NO.2
2023_MES_607154_1
8456/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
JAMNAGAR
AS PER NIT AND TENDER
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO 2
₹50,000
Yes
1 Jan 2024
30 Jun 2023
29 Jul 2023
30 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
Cleaning of sewage lines 100 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of sewage lines 150 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of sewage lines exc 150 but n exc 300 mm dia from manhole to manhole by manual / mechanical rodding, removing all sludge / waste and making the line functional including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning & desludging manholes/chamber depth not exc 1.0 m, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning & desludging manholes depth exc 1.0 m but not exc 2.0 m, of any size & shape by removing all sludge / waste etc from the manholes and finally cleaning with fresh water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of gully traps by removing all sludge / waste etc including cleaning of connected pipe up to 1st Man Hole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning of floor traps by removing all sludge / waste etc including cleaning of connected pipe up to gully trap to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Removal of blockage from Indian WC / EWC by removing all sludge / waste etc including cleaning of connected pipe up to first manhole to remove blockage, and finally washing with clean water including disposing of all sludge / waste etc (in covered tanks) outside M.O.D land complete all as specified and directed.
Cleaning & desludging septic tank of cap upto 25 users by pumping out sewage & sludge and disposing all waste including liquid in covered tanks outside M.O.D land, burried in ground and finally cleaning & washing with fresh water complete all as specified and directed.
Excavation in trenches or cleaning of drain n.exc 1.50 meter wide & n.exc 1.50 meter depth for foundations etc shafts, well cesspits, manholes, pier holes etc n.exc 10.00 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Demolition and breaking up 150 mm dia bore RCC / salt glazed stone ware drain pipe including PCC packing under hunching against the sides of pipe bed and complete PCC of bed and removal of debris to outside MOD land complete all specified and directed.
Demolition and breaking up 200 mm dia bore RCC / salt glazed stone ware drain pipe including PCC packing under hunching against the sides of pipe bed and complete PCC of bed and removal of debris to outside MOD land complete all specified and directed.
M&L for 150 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed.
M&L for 200 mm bore reinforced concrete hume pipes, class NP2, laid and jointed with collars complete all as specified and directed.
M & L for PCC 1:4:8 type D-1 using 20 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 150 mm bore, after they are laid and tested complete all as specified and directed.
M & L for PCC 1:4:8 type D-1 using 20 mm graded stone aggregate as in bedding including haunching & packing under and against the side of pipe 200 mm bore, after they are laid and tested complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil complete all as specified and directed.
Removing excavated soil/drain waste material to a distance exc 1.5 Km but n.exc 5 Km and depositing at a level not exceeding 1.50m above the starting point complete all as specified and directed.
Cutting into existing manholes in running sewage line for connecting new drains of 150 / 200 mm internal dia of pipe, making good to walling and rendering, cutting out branch channel, and as required complete all as specified and directed.
Demolition of reinforced cement concrete (including cutting of reinforcement as required to facilitate demolition) in any position and of any description complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for manholes/soakage well and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed. Note:- Reinforcement steel will be measured & paid separately.
M & L mild steel TMT bars 10mm dia and over cut into length bend to shape required incld cranking bending spirally for hooping for column, hooking ends and binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with clips.quality conforming to Fe-410-W (Gde,E-250) complete all as specified and directed.
Reinforced cement concreteType B1 1:2:4 (using 20mm graded stone aggregate) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, cover and the like complete all as specified and directed.
Formwork to soffits of suspended slabs such as flat roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, jointed with solvent cement , fixed on walls or floors with clamp incl dismantling of rain water pipes complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, jointed with solvent cement , fixed on walls or floors with clamp incl dismantling of rain water pipes complete all as specified and as directed.
S&F PVC (SWR) bends of 75 mm bore of any radius all as specified and directed
S&F PVC (SWR) bends of 110mm bore of any redius all as specified and directed.
S&F PVC (SWR) cowl of 75 mm bore of any radius all as specified and directed
S&F PVC (SWR) cowl of 110mm bore of any redius all as specified and directed.
S & F PVC (SWR) branch piece. Single (single Y) equal or unequal 75 mm bore fixed complete all as specified and directed.
S & F PVC (SWR) branch piece. Single (single Y) equal or unequal 110mm bore fixed complete all as specified and directed.
S &F PVC (SWR) branch piece, double (double Y) EQUAL OR UNEQUAL 75 mm bore fixed complete all as specified and directed.
S &F PVC (SWR) branch piece, double (double Y) EQUAL OR UNEQUAL 110mm bore fixed complete all as specified and directed.
Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap of Cast iron 100 mm, front or back inlet including all connection and provision of lime concrete base complete all as specified and directed.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover with hinges, white, closed pattern with flat bottom, and cover with aluminised hinging device, 'P' or 'S' trap of 100 mm bore including all connection complete all as specified and directed.
S&F in repairs stainless steel grating with or without hole of size 150 mm x 150 mm fixed with cement complete all as specified and directed.
S&F in repair PVC (SWR) floor trap/Nahani trap, plain with grating including jointing with solvent cement, outlet dia 75 mm, including jointing to waste pipe fixed in cement concrete 1:2:4, Type B1 using 20 mm graded stone aggregate complete all as specified and directed.
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, plain with grating including jointing with solvent cement, including jointing to waste pipe fixed in cement concrete 1:2:4, Type B 1 using 20 mm graded stone aggregate complete all as specified and directed.
Demolition of brick / stone masonry / Block masonry work built in cement n.exc 50m, complete all as specified and directed.
M&L for providing precast cement concrete Type C-1(1:3:6) (using 20mm graded stone aggregate) solid building blocks exc 10 cm in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars complete all as specified and directed.
Demolition Concrete of any description and in any position complete all as specified and directed.
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortat (1:3) using water proofing compound @ 3% by weight of cement finished even and fair as in sunken floor and wall complete all as specified and directed. Note: WPC will be measured and paid separetely.
M&L for applying two coats of water proofing coating by using Super Latex manufacured by pidilite industries Ltd or equivalent product manufactured by Sika/ Fosroc/ Choksey mixed in chemical water and cement ratio as per manufacturer's instructions both on floor as well as on walls of sunken complete all as specified and directed.
Supply only water proofing compound complete all as specified and directed.
M &L for cement concrete type E-2 1:5:10 (using 40 MM graded crushed stone aggregate) as in mass filling in sunken floor of toilets and similar work complete all as specified and directed.
Cutting / drilling hole in brick wall / RCC beam or slab exc 300mm deep of WC/bath by mechanical mean and fixing with and including 40mm GI pipe as spouts pipe of require length at site, complete all as specified and directed.
M & L for Broken stone Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 40mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in flooring laid in panels finished even and smooth with out using extra cement complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8, type D-2, (using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and directed.
Dismantling Stone slabs and tiles laid dry and pointed of any description or thickness in floors, aprons etc complete all as specified and directed.
Material & Labour for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with grey cement and pigment complete all as specified and directed.
M&L for sand filling (25mm thick sand screed bed) under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishing surface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete all as specified and directed. Note : The concrete shall be laid at a stretch n.exc 3.0 m in length and every turning/ corners.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for cement concrete type B-1, 1:2:4 (using 12.5mm graded stone aggregate) 25mm thick as in leveling course of flooring & roof complete all as specified and directed.
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed.
M&L for Non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding exceeding 0.11 sqm but no exceeding 0.18 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed.
M&L for light shade colour vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick screed bed or bedding layer in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per item No 59 but in skerting including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M&L for joint free (edge cut) coloured glazed ceramic tiles 7 mm to 8 mm thick (square / rectangular) polished of size 350x250x7 mm / 450x350x7mm as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed.
S&F in repair Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
M & L for rendering 15mm thick on fair face of concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement all as specified and directed.
Dismantling of wrought iron or mild steel work (i.e. purlin wind tie and similar works etc) or of any description not other wise provided for, complete all as specified and directed.
S&F for mild steel work as trusses (framed), trussesed, purlin, rails and other fastening and heavy brackets framing (beam, Tee, angle, channel or fast section) including distance pieces etc Fe-410-w complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, velley gutter fixed with self tapping screws complete all as specified and directed.
Dismantling fencing wire mesh / chain link fencing, any type all as specified and directed.
S&F PVC coated chain link fencing 50mm x 50mm x 4mm thick mesh secured with MS flats, straining bolts including provision of binding wire complete as specified and directed. Note : Staining bolts, nuts and washers as supply only, flat iron and 10mm dia round bars shall be, measured and paid separately.
S & F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling of concertina coil of any type or size all as per directed by Engr-in-Charge. Note :- Each line wire to be measured.
Dismantling of barbed wire of any type or size all as per directed by Engr-in-Charge. Note :- Each line wire to be measured.
S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165 complete all as specified and directed.
S&F in repairs Galvanised 2 strand steel barbed wire barbed with 2.24 mm dia bars at 75 mm specing and straining & fitting to any type of standard rails straning bolts, including securing or tving at crossing with the provision of galvanized MS wire staples or steel pins etc complete all as specified and directed. Note : Each line of steel barbed wire to be measured.
S&F of mild steel galvanised punched type concertina coil of loop dia 1050 mm dia (dia of coil with unstretched) and fixed to angle iron with and including of 3.15 mm dia GI wire complete all as specified and directed. Note: One coil weighing approxmately 12 to 13 Kg shall not be stretched more than 8 RM span.
Fixing in repairs Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
M&L for preparation of newly or untreated steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
KEVAL ENTERPRISE
EVEREST BUILDERS
J J ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .