| 1 | L1₹6.1 LAccepted-AOC | ₹6.1 L | L1 | Accepted-AOC Work Awarded |
Tender Value
₹6.4 L
EMD Value
₹16,808
Closing Date
5 Feb 2026, 3:00 pmClosed
Ex. Engineer (Pr.) CSPZ
Room No. 300, 3rd Floor, Old Hindu College Bldg. Kashmere Gate, Delhi-110006
Improvement of Union Office and Construction of one room for Security Guard at Kasturba Hospital / City SP Zone
2026_MCD_264637_1
EE(Pr.)CSPZ/TC/2025-26/27_01
Open Tender
Civil Works
90 days
Kasturba Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹16,808
16 Apr 2026
29 Jan 2026
5 Feb 2026
29 Jan 2026
5 Feb 2026
29 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size)derived from natural sources.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access plateform.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete in small lintels not exceeding 1.5 m clear span upto floor five level including the cost of required centering shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement: 3 fine sand ) on exposed surfaces but excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more.
Grading roof for water proofing treatment with : cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size)
Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/15 conforming to IS: 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-1 (hessian based self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or pea-sized gravel spread at 6 cubic diametre per square metre including preparation of surface but excluding grading complete with : Bitumen felt (hessian base)type 3 grade conforming to IS: 1322.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required . In gratings, frames, guard bar, ladders, railings, brackets, gates and similar works.
Providing and fixing 1 mm thick M.S.sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S.gusset plates at the junction and corners,all necessary fittings complete,including applying a priming coat of approved steel primer. Using M.S. angels 40 x40x 6 mm for diagonal braces
6 mm cement plaster to ceiling of mix : 1:3 (1 cement :3 fine sand)
12 mm cement plaster of mix : 1:4 (1 cement :4 coarse sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including priming coat with cement primer
Painting with synthetic enamle paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with gery cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with Base of cement mortar 1:4 (1 cement :4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps,skirting,dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing and polishing complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete; Size of Tile 60x60 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m .
Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand including finishing smooth etc. complete as per direction of Engineer-in-charge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work upto plinth level: 1:2:4 (1 Cement: 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size.
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement :4 coarse sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicon additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including base coat of water proofing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10sqm)
Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion: (i) Single socketed pipes; 110 mm diameter
Providing and fixing on wall face unplasticised -PVC moulded fittings/accessories for unplasticised -Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion: Bend 87.5o; 110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs,screwed with M.S.screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement :4 coarse sand) and making good the wall etc. complete: 110 mm
Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sectios/ appropriate Z secions and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips,or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/neoprene gasket etc. etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/penelling, C.P.brass/stainless steel screws, all complete as per architectual drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately): For fixed portion; Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sectios/ appropriate Z secions and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips,or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/penelling, C.P.brass/stainless steel screws, all complete as per architectual drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately): For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately); Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door,windows,ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc.complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness.
Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade) particle board Grade I,Type II conforming to IS :12823 in panelling fixed in alluminium doors,windows shutters and partition frames with C.P.brass/stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge: Pre-laminated particle board with decorative lamination on one side and balancing laminatioin on other side.
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with necessary screws etc.complete : 100 mm
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 per IS :1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200 x 10 mm
Providing and fixing ISI marked aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x 16 mm
Providing and fixing IS :3563 marked Aluminium die cast body tubular type universal hydraulic door closer necessary accessories and screws etc.complete.
Demolishing cement concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-Charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished welded type tubes.
Providing and fixing of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ± 5% total coated thickness (TCT), Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws f size (5.5 x 55 mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trussed and including cutting to size and shape wherever required
Constructing brick masonry road gully chamber 50 x 45 x 60 cm with bricks of class designation 75 in cement mortar 1:5 (1 cement :5 Coarse sand) including 500 x 450 mm precast R.C.C.horizontal grating with frame completes as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Carriage of material by mechanical transport including loading, unloading and stacking complete; Lime, moorum, building rubbish, earth, manure or sludge and excaveted rock : Lime, moorum, building rubbish ;18 km lead
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_307084.pdf
BOQ Comparative Chart
xlsx
finsummary_307084.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Tendernotice_2.pdf
PDF • 28.52 MB
BOQ_307084.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid