Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAdmitted-Finance AMBAGAN TEZPUR TOWN PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L1 | Admitted-Finance | |
| 2 | L2₹34.8 L+₹6,961 (0.20%)Admitted-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Admitted-Finance | |
| 3 | L3₹37.0 L+₹2.2 L (6.36%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹39.6 L+₹4.8 L (13.9%)Admitted-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L4 | Admitted-Finance | |
| 5 | L5₹42.0 L+₹7.2 L (20.7%)Admitted-Finance CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S RANA ENGINEERING ENTERPRISE L4 | M/S S.S.Corporation L1 | shree kamakhya traders L6 | Saraswati Auto Works L5 | PURBANCHAL BUILDERS L2 | Shree Krishna Traders L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to GI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion complete all as specified and as directed
NOTES : The unit rate includes for protection pipe and GI Earth strip from top of earth plate up to 7.00 meter above ground level. | 6 | Each | 4,600 ₹27,600 | 4,400 ₹26,400 Lowest | 5,400 ₹32,400 | 4,750 ₹28,500 | 6,999 ₹41,994 | 8,000 ₹48,000 |
| 2.00 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed. | 229 | Cum | 230 ₹52,670 | 385 ₹88,165 | 250 ₹57,250 | 220 ₹50,380 Lowest | 229 ₹52,441 | 250 ₹57,250 |
| 3.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed. | 133 | Cum | 120 ₹15,960 | 160 ₹21,280 | 150 ₹19,950 | 125 ₹16,625 | 89 ₹11,837 Lowest | 200 ₹26,600 |
| 4.00 | Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed. | 81 | Cum | 170 ₹13,770 | 120 ₹9,720 Lowest | 120 ₹9,720 Lowest | 125 ₹10,125 | 189 ₹15,309 | 200 ₹16,200 |
| 5.00 | M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed.
Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for. | 68 | Cum | 380 ₹25,840 | 820 ₹55,760 | 45 ₹3,060 Lowest | 425 ₹28,900 | 699 ₹47,532 | 800 ₹54,400 |
| 6.00 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed. | 6,800 | Each | 11 ₹74,800 | 12 ₹81,600 | 13 ₹88,400 | 10 ₹68,000 Lowest | 12.99 ₹88,332 | 12 ₹81,600 |
| 7.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. | 966 | RM | 1,960 ₹18,93,360 | 698 ₹6,74,268 Lowest | 2,000 ₹19,32,000 | 2,120 ₹20,47,920 | 1,859 ₹17,95,794 | 1,500 ₹14,49,000 |
| 8.00 | S&F GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed. | 18 | RM | 700 ₹12,600 | 980 ₹17,640 | 650 ₹11,700 | 640 ₹11,520 Lowest | 799 ₹14,382 | 1,200 ₹21,600 |
| 9.00 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm GI strip complete all as specified and directed. | 64 | RM | 170 ₹10,880 Lowest | 320 ₹20,480 | 180 ₹11,520 | 260 ₹16,640 | 229 ₹14,656 | 650 ₹41,600 |
| 10.00 | S&F Automatic Power Factor Correction (APFC) Panel with MD-XL Capacitor and MCCB 400 Amps, 4 Pole, 35KA as incommer for 3 Phase, 415 V & 50 Hz system of capacity 250 KVAR with 6 steps (2x25 + 4x50) complete all as specified and directed. | 1 | Each | 6,06,000 ₹6,06,000 | 8,00,000 ₹8,00,000 | 7,30,000 ₹7,30,000 | 6,49,000 ₹6,49,000 | 3,59,999 ₹3,59,999 Lowest | 4,50,000 ₹4,50,000 |
Tender Value
Refer Docs
EMD Value
₹84,480
Closing Date
25 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
WORK SERVICES FOR STANDARISATION OF POWER SUPPLY INFRASTRUCTURE FOR CRITICAL EQUIPMENT AT SU AF UNDER GE MISSAMARI
2026_MES_750944_1
8612/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MISSAMARI
₹84,480
Yes
3 Mar 2026
2 Feb 2026
27 Feb 2026
2 Feb 2026
25 Feb 2026
11 Feb 2026
2 Feb 2026 - 8 Feb 2026
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6 mm thick, buried directly in ground vertically to a depth not less than 2.25 METRE below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 METRE below normal ground level, connected to GI Earth Strip 32 x 6 mm drawn through and including GI Pipe 40 mm bore (dia) ‘light grade’ for protection upto 1.00 METRE above the Floor Level of the Building where Main Switch/DB situated, by means of Bolts, Nuts, Check Nuts and Washers etc., Earth Plate surrounded by a packed thickness of Char Coal or coke dust mixed with common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20 mm graded aggregate) and Pre-cast RCC 1:2:4 (20mm graded aggregate) Cover Slab 350x350 x50mm, reinforced with and including 8.0 mm dia TMT Bars @ 100 mm centre to centre both ways, GI wire mesh, Funnel with GI Watering Pipe 20mm bore (dia) ‘medium grade’, necessary excavation in soft/loose soil, returning, filling in and removal of Surplus Spoil upto a distance of 50 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion complete all as specified and as directed NOTES : The unit rate includes for protection pipe and copper strip from top of earth plate up to 7.00 meter above ground level.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
S&F GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over insulators or any other indicated situation for loop earthing etc as required with 32 x 6mm GI strip complete all as specified and directed.
S&F Automatic Power Factor Correction (APFC) Panel with MD-XL Capacitor and MCCB as incommer for 3 Phase, 415 V & 50 Hz system of capacity 250 KVAR with 6 steps (2x25 + 4x50) complete all as specified and directed.
S&F Servo Controlled Voltage Stablizer of capacity 250KVA (Conforming as per BIS 9815, Part I 1994, Reaffrimed 2019), 3 Phase, 50Hz,, naturally oil cooled, indoor, unbalanced type,, copper wound, digital display type, relay free smooth and silent operation with first filling of transformer oil (IS 335 : 2018) having the following specifications complete all as specified and directed. (a) Input Voltage: 300 Volts -480 Volts (b) Output Voltage: 415 Volts + 1% (Adjustable) (c) Rated Frequency : 50Hz (d) No distoration in wave form (e) Responde time not to excced 10 mili second (g) Rate of correction more than 6 Volts/Second for per phase (h) Class Insulation A (j) No load losses less than 0.5% (k) Full load losses less than 2.5% (l) Duty cycle continuous 24x7 (m) Efficency more than 95% (n) Type of load 3 phase, unbalanced type (o) Digital Display Voltage cut off PROTECTION (a) Overload/Short Circuit protection (b) High/Low Voltage cut off (c) By pass arrangement in case of emergency (d) Single phase sequence change protection
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
Tender8612.rar
Tender Documents • 0.58 MB
BOQ_841052.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .