Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC | ₹3.2 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.0 Cr+₹86.7 L (27.5%)Rejected-AOC HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | ₹4.0 Cr+₹86.7 L (27.5%) | L2 | Rejected-AOC Not Being Lowest |
| 3 | L3₹4.5 Cr+₹1.4 Cr (44.0%)Rejected-AOC | ₹4.5 Cr+₹1.4 Cr (44.0%) | L3 | Rejected-AOC Not Being Lowest |
Tender Value
₹3.2 Cr
EMD Value
₹3.9 L
Closing Date
6 Sept 2022, 6:00 pmClosed
Chief Engineer Chennai Zone Chennai
CHIEF ENGINEER, CHENNAI ZONE, ISLAND GROUNDS, CHENNAI-600 009
CONSTRUCTION OF GIRLS HOSTEL AND ALLIED INFRASTRUCTURE FOR GIRL CADETS IN SAINIK SCHOOL KAZHAKOTTAM AT TRIVANDRUM
2022_MES_540344_1
85168/E8
Open Tender
Civil Works
Lump-sum
360 days
Trivandrum
As per NIT
7 documents required · 7 mandatory
₹2,000
Yes
GE Trivandrum
₹3.9 L
Yes
26 Sept 2022
23 Jul 2022
8 Sept 2022
23 Jul 2022
6 Sept 2022
25 Aug 2022
24 Jul 2022 - 12 Aug 2022
Amount
Lumpsum price worked out by the tenderer for BUILDINGS/ STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VII
SCHEDULE 'A' PART VIII (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES.
INTERNAL WATER SUPPLY
S & F Hand Shower 15mm Bore( health Faucet) incl ABS body with 8mm dia,1.20 mtr long flexiable tube and wall hook etc all as specified and directed
INTERNAL ELECTRIC SUPPLY
S&F ceiling fans complete with blades, down rods, and accessories, 230V, 900mm sweep min air delivery 210 cfm with suitable service value, five star rated connecting up including provn of three core flexible copper wire of size 23/0.0076 from ceiling rose to ceiling fan all as directed.
S&F 20W (1X4') LED Stout plus surface & wall mounted LED fitting, environment friendly energy efficient with electronic driver complete with all fixing arrangement all as specified and as directed.
S&F 10W (1X2')LED basic all purpose surface and wall mounting LED baten with polycarbonate housing & integrated electronic driver Light fittings with all attachment & fixing arrangement all as specified and as directed.
S&F bed side reading lamp LED 3 watts, with control switch adjustable lamp 230 volts duly fixed on wall al as directed.
S&F LED security light fitting 25 watt 230V AC made up of pressure die cast aluminium housing with high efficiency LED light as lighting source and lens with toughened glass having bottom opening separate driver compartment with IP 66 protection and impact resistance IK07 including bracket alongwith GI medium grade tube of 40mm dia, 1.5 metre long bend to shape 120 degree and 2 Nos of MS clamp 25 x 4mm of required length/size including nuts nd bolts with one coat of red oxide & two coats of silver mtallic paint fixed complete with impact and corrosion resistant all as directed.
S&F VTPN DB 4 way, double door having IP 43 protection with isolated neutral bar, insulated busbar assembly with door earthing, mechanical impact strength IK 08 suitable for MCCBs upto 125A as incomer complete all as directed.
S&F MCCB 63 Amps 4 Pole with adjustable thermal setting, conforms to IEC-60947-II suitable for isolation fixed short circuit setting with adjustable over load setting Ir = (0.8 to 1.0)xIn all as specified and as directed.
S&F MCB DB SPN 8 way, having degree of protection as per IP 43 with metal door (double door) 415 Volts complete with 200 Amps rated copper bus bar with neutral link with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 2 + 6 with blanking plates etc, complete all as specified and as directed .
Suppy and fix MCB TPN 63 Amps,415 Volts,10 KA, "C" series all as directed.
Suppy and fix MCB SPN 32 Amps,240 Volts,10 KA, "B" series all as directed.
Suppy and fix MCB SP 6-32 Amps,240 Volts,10 KA, "B" series all as directed.
EXTERNAL WATER SUPPLY
M&L Cutting the existing 150 mm CI pipe and inserting the TEE (150X150X100 mm) and necessary threading, union etc complete all as specified and as directed..
Supply and fix Sluice Valve Class PN 1.0 of 100 mm bore with stainless steel spindle bronze gate & seating rings both sides flanged & drilled type ISI Marked including suitable rubber gasket joints with bolts & nuts etc, complete all as specified and as directed. complete.
Supply and fix Sluice Valve Class PN 1.0 of 80 mm bore with stainless steel spindle bronze gate & seating rings both sides flanged & drilled type ISI Marked including suitable rubber gasket joints with bolts & nuts etc, complete all as specified and as directed.
M&L for construction of valve chamber of internal size 600x600x600 mm with necessary PCC for foundation,brick wall including MS sheet cover 3 mm thick complete all as specified and as directed.
Supply & Fixing Valve Stop, screwed both ends for iron pipes of size 50 (2") mm bore complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY
S&F cable route indicator made of 15 x 15 x 6mm thick MS plate welded with 10mm x 30cm long MS rod grouted in PCC block of size 0.2 x 0.2 x 0.3 m and writing LT cable complete all as directed.
Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT feeder pillar box (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 HZ AC supply system, having bus bar chamber with insulated aluminium bus bars 200 Amps. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, powder coated finish , front opening type, with aprons for cable entry, with double door shutter and locking arrangementS (including provn of 65mm Godrej (Freedom) lock with 2 keys , internal wiring with PVC insulated, copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. Panel should be above ground level .The scope of work includes the following:-
Note : All out going feeders shall be connected by cable through suitable size gland plate / glands.
Supply and fix 6 Sqmm aluminium conductor weather proof flat twin core cable with PVC conduit of size 25mm from junction box to security light all as per specification .
Supply and fixing SMC terminal box of size 230 x 170 x 105 mm(internal diamensions) made of impact resistance plastic & heat resistant materials including MCB SP 6A with DIN bar and 4 way terminal block, and fixing the box to street light pole made of 25x 3mm flat iron with clamps, nuts and bolts all as specified.
WATER COOLER
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase , 230 volt, 50 hz having approx storage capacity 80 ltrs and and nominal cooling capacity 40 Ltr/Hr incl provision of suitable fixing arrangements complete all as directed by Engineer-in-Charge. Make: ,voltas,bluestar,godrej
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with surge protection complete all as specified and directed by Engineer-in-Charge.
DJ GROUP
AKASH CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .