| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST AMOUNT QUOTED BY JOSEPH V J | |
| 2 | L2₹2.5 L+₹377.90 (0.15%)Rejected-AOC VARAMBATHUKUDIYIL BLDG NELLIKUZHY P O KOTHAMANGALAM 686 691 | KOTHAMANGALAM | ERNAKULAM | KERALA | 686691 | L2 | Rejected-AOC LOWEST AMOUNT QUOTED BY JOSEPH V J | |
| 3 | L3₹2.5 L+₹1,482.75 (0.60%)Rejected-AOC KADAVOOR | L3 | Rejected-AOC LOWEST AMOUNT QUOTED BY JOSEPH V J | |
| 4 | L4₹2.5 L+₹8,304.90 (3.38%)Rejected-AOC | L4 | Rejected-AOC LOWEST AMOUNT QUOTED BY JOSEPH V J |
Tender Value
₹2.5 L
EMD Value
₹6,179
Closing Date
3 Apr 2025, 6:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
OFFICE OF THE ASSISTANT EXECUTIVE ENGINEER, LIDEW DIVISION, DISTRICT PANCHAYATH PAINAV IDUKKI
GENERAL-IDP Works 2023-24 Kodikkulam GP, Project Number - SOO402/25-Ezhalloor S C Colony DWSS Complection - Providing Motor Pump Set-General Electrical Work-TENDER
2025_LSGD_753909_3
12/T/AEE/LIDEW/IDK/2024-2025
Open Tender
Electrical Works
Item Rate
KODIKULAM
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹6,179
Yes
28 Jun 2025
22 Mar 2025
5 Apr 2025
22 Mar 2025
3 Apr 2025
22 Mar 2025
22 Mar 2025 - 3 Apr 2025
Amount
Electrification
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD509512/2024-2025:Supply, conveyance, erection, testing and commissioning of 15 HP ,Vertical type open well submersible pump set working on 3 phase 415 V, with head range 123-314 and discharge range 275-75(LPM) (DECAN ) Delivery Size:3"etc. as required
OD509505/2024-2025:Supply and providing BCH SPS SD-PREM 3PS13.2-20A CPSDPYK with protection against overload, single phasing, phase reversal & severe unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1 specifications suitable for 15 HP submersible motor pump set complete duly internally connected
OD509520/2024-2025:Supply and fitting L&T module for mobile starter M power pro etc, as required.
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
1.17.32:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mm
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.6.4.53:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 3 Run
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
OD509460/2024-2025:Supply, conveying & fixing 80 mm dia medium GI pipe cutting in to required length, facing the cutting edges and supply and providing MS flanges having 12 mm thickness and minimum 63 mm depth on both ends of every 2 mtr or nearest long , including conveyance charges to pumphouse and labor charges for loading, unloading, fixing on alignment for suction/delivery side pipe using suitable rubber packing etc.
OD509447/2024-2025:Supply, conveyance and erection of 80 mm ISI marked Cast Iron flanged type Check Valve / Non Return valve as per IS: 5312 PN 1.6 with CI body , CI door with SS hinge pin, bronze seating ring , natural rubber door face and gaskets etc. and fixing the same in position using necessary rubber packing ,bolt nut and washer etc.
OD509457/2024-2025:Supply, conveyance and erection of 80 mm ISI marked Cast Iron flanged type Rising spindle Sluice valve as per IS: 14846 PN 1.6 with CI body and SS spindle and fixing the same in position using necessary rubber packing ,bolt nut and washer etc.
OD509472/2024-2025:Supply and providing 75 mm 8 Kg/cm2 PVC Pipe including suitable coupler etc.
OD509532/2024-2025:Supply and providing CLAMP SET CI 80MM HEAVY
OD509533/2024-2025:Supply and fitting 80 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
OD509534/2024-2025:Supply and providing NYLON ROPE MAXIMA LG14MM
OD509535/2024-2025:Earthing with pipe earth using 40 mm GI pipe and required accessories including labor charges etc. as required.
OD509536/2024-2025:Supply and providing Cable Joint Tape etc. as required.
OD509537/2024-2025:Supply and providing Cotton waste etc. as required.
OD509538/2024-2025:Supply and providing Shellac 50 ml etc. as required.
OD509546/2024-2025:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
OD509451/2024-2025:Supply and fixing 63 A 2 way neutral link on SMC or DMC base and giving connections
OD509461/2024-2025:Supply and fixing 25x6 mm brass bolt, nut and washer
SK ELECTRICAL (BID ID -2181527)
SATHYAN D (BID ID -2184146)
Mahesh KR (BID ID -2185729)
Bidder Name
Mahesh KR
JOSEPH V J
SATHYAN D
SK ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1223811.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .