SE ETC I, Lucknow
Pareshan Bahwan, Vibhuti Khand, Lucknow
Work
2023_UPTCL_777982_2
Short term e-tender 84/2022-23
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹236
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹2,000
26 May 2023
18 Mar 2023
25 Mar 2023
18 Mar 2023
24 Mar 2023
18 Mar 2023
Amount
Following detailed Work against Construction of 33 K.V. Bus Sectionalizer between 63 MVA Transformer-II & III in 33 K.V. Main Bus including Dismantling & Erection of Lttice type Main & Auxiliary Structures, Erection of 33 KV Bus Isolator, Dismantling, Splitting & Re-Stringing of Existing 33 KV Main Bus of Twin ACSR 'Moose' Conductor including opening of jumpers & Re-Jumpering and other associated works at 132 / 33 KV Sub Station Martinpurwa, Lucknow under E.T.D. - I, Lucknow with all cost of men and T&P for satisfactory completion of the work is to be done :
Safe Loading, Carriage of following euipments from 132 K.V S/S SGPGI, 220 K.V S/S Hardoi Road and 220 KV S/S Satrikh Road, Lucknow to 132 K.V S/S Martinpurwa, Lucknow and Unloading at storage place as per direction of Supervising Engineer including cost of Hydra, Carriage vehicle, Men, Misc. consumables, T&P, making coil of cables before loading etc. required for satisfactory completion of Job:- (01 Job for all items) i) 33 K.V. ABL Structure for BI: 01 Set ii) 33 K.V. Post Insulator: 03 No. iii) Hardware Fitting: 06 No. iv) 70 KN Disc Insulator: 30 No. v) Isolator Clamp for Twin Moose: 06 No. vi) Isolator Operating Mechanism & Junction Box: 01 Set vii) Post Insulator Clamp for Twin Moose: 03 No.
Safe Dismantling of Lattice type Main Structure including opening of jumpers, clamps, de-hoisting of insulators & fitting and their shifting from site to storage place at the sub station.
Erection of following Structures / Equipments including their shifting from storage place to erection site with all other associated works as per technical specifications :
Lattice type Main & Auxiliary Structures (33 K.V. as per Layout Plan)
36 K.V. Bus Isolator with Post Insulators (without E/S)
Cutting, Straightening, Laying 700 mm below inside ground & above ground of 75 mm x 10 mm, 50 mm x 6 mm & 25 mm x 5 mm size M.S. Flats to be provided by Department as per requirement for Earthing of Aux. Structures, Equipments, C&R Panel & Cable Trenches including welding with main Earthmat and with the object to be earthed, excavation of Trenches, its back filling, Painting of Earthmat above ground level in Bus Green colour including all other associated works to complete the Earthing work satisfactorily, as per Technical Specifications :
Earthing of Main & Aux. Structures and Equipments with 50 mm x 6 mm size M.S. Flat
Opening of existing Jumpers of Twin ACSR 'Panther' / 'Moose' Conductor between existing 33 KV Main Bus Bar to 33 KV Bus Isolator of 33 KV Feeders Bays / 33 KV Section Isolator / 63 MVA T/F-I & II / 250 KVA Station Transformer. (01 Job for each Isolator)
Opening of existing Jumpers of Single ACSR Panther Conductor between existing 33 KV Main Bus Bar to 33 KV PT / LA. (01 Job for each PT / LA)
De-stringing of existing 33 KV Main Bus Bar of Twin ACSR 'Moose' Conductor including De-hoisting of Disc Insulator Tension String with Tension fitting from Gantry alongwith shifting of the old conductors etc. from Switchyard to Store at the sub station. (01 Job per phase per section)
Re-Stringing of 33 KV Main Bus Bar of Twin ACSR 'Moose'Conductor after cutting of Main Bus conductor at suitable place for adding one number section isolator in Main Bus including Hoisting of Disc Insulator Tension String with Tension Fitting from Gantry, , spacers, PG- clamps etc. alongwith shifting, cutting, bending of the new conductor, Tension Fittings etc. from switchyard to stores at the sub station.(01 Job per phase per section)
Re-Jumpering of 33 KV Bus Isolators of 08 No. Bays from 33 KV Main Bus Bar by using existing Jumpers of Twin ACSR 'Panther' / 'Moose' Conductor (01 Job for each isolator)
Re-Jumpering of 33 KV PT / LA with 33 KV Main Bus Bar by using Single ACSR Panther Conductor.
Jumpering of 33 KV Bus Isolator with 33 KV Main Bus Bar by using Twin ACSR 'Moose' Conductor.
Fixing of Support Structure by using cement, concrete mixture of 1:1.5:3 in LV Side of 63 MVA Transformer-II (Make- Aditya) including Fabrication of structure from old & used tower parts to be provided by the department with all cost of welding, cutting and men, misc. consumables, T&P etc. reuired for completion of job.
Opening of Twin ACSR 'Moose' Conductor Jumpers of 63 MVA Transformer-II LV Side.
Installation of 33 K.V. Post Insulator on Support Structure including making holes in the support structure.
Jumpering of 33 KV Post Insulator with 33 KV C.T. of 63 MVA Transformer-II by using Twin ACSR 'Moose' Conductor.
HARE KRISHNA ENERGY PROJECTS
JAI BHART ENGG WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .