Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Quotation Hence Approved | |
| 2 | L2₹4.5 L+₹11,756.77 (2.69%)Rejected-AOC | L2 | Rejected-AOC Higher Rate Hence Rejected | |
| 3 | L3₹4.6 L+₹21,235.14 (4.85%)Rejected-AOC CHAITHRAM PENSION BHAVAN ROAD MALAPPURAM POST 676505 | MALAPPURAM | KERALA | 676505 | L3 | Rejected-AOC Higher Rate Hence Rejected | |
| 4 | L4₹4.7 L+₹33,411.92 (7.63%)Rejected-AOC PANACHIKKAL H PULLARA VALLUVAMBRAM MALAPPURAM | L4 | Rejected-AOC Higher Rate Hence Rejected | |
| 5 | L5₹5.0 L+₹61,262.09 (14.0%)Rejected-AOC | L5 | Rejected-AOC Higher Rate Hence Rejected |
Tender Value
₹5.6 L
EMD Value
₹14,048
Closing Date
14 Oct 2024, 1:00 pmClosed
Assistant Executive Engineer
Office of the Assistant Executive Engineer, PH Sub Division Perinthalmanna
DEPOSIT-District Panchayath Deposit works-Pipe line extension from vadakkanpaloor puramboke to karimbankunnu area for life mission houses in ward No 11 in Pulamanthole Grama Panjayath-Pipeline Work
2024_KWA_694906_1
WRD/KWA-CEP/TR/201/2022_26_1
Open Tender
Civil Works - Water Works
Item Rate
90 days
Pulamanthole
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,240
₹14,048
20 Dec 2024
7 Oct 2024
15 Oct 2024
7 Oct 2024
14 Oct 2024
7 Oct 2024
7 Oct 2024 - 14 Oct 2024
Amount
1- APPX-A-Laying Distribution Lines (Cost Index:36.44 %)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.12.8:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 80mm diameter nominal bore.
100.12.7:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 65mm diameter nominal bore.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD97362/2023-2024:Interconnection of 90mm PVC to 75mm PVC pipes
OD110722/2023-2024:Interconnection of 75mmPVC to 75mm PVC Pipe
18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
18.17.6:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
2- APPX-B-Cost of Pipe and specials (Cost Index:36.44 %)
100.98.213:Supply of PVC Pipe, 6kg/cm2, 90mm Dia.
100.98.212:Supply of PVC Pipe, 6kg/cm2, 75mm Dia.
OD97357/2023-2024:Supply of 80 mm GI pipe-medium
OD110834/2023-2024:Supply of 65mm GI pipes medium
MUNEER K
ARUN SEKHAR
NISHAD P
AMEERSHA.P
Bidder Name
MUNEER K
NISHAD P
ARUN SEKHAR
AMEERSHA.P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .