Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC PLOT NO 927 SECTOR 47 GURGAON 2022R6406 | GURGAON | ₹1.7 Cr | L1 | Accepted-AOC LOA issued |
| 2 | L2₹1.7 CrRejected-Finance ADJOINING PREET PALACE LUDHIANA HIGHWAY NH 95 MORINDA BYPASS VILLAGE BADDI MADOULI MORINDA RUPNAGAR PUNJAB 140101 | RUPNAGAR | PUNJAB | 140101 | ₹1.7 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹1.7 CrRejected-Finance DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | ₹1.7 Cr | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | INDIAN SECURITY AND FIRE SAFETY L3 | PROMARK TECHSOLUTIONS PRIVATE LIMITED L2 | Kenbrook Automation Private Limited L1 |
|---|---|---|---|---|---|---|
| 1.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 1,550 | Metre | 36 ₹55,800 | 34 ₹52,700 | 32 ₹49,600 |
| 2.00 | `Supply Installation Testing and Commissioning of Wiring for Fire Alarm system with the following sizes 2 x 1.5 sq.mm of FRLS insulated copper conductor Double core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required.
Make Finolex /Polycab / Plaza / Havells` | 13,110 | Metre | 57.5 ₹7.5 L | 56.5 ₹7.4 L | 54 ₹7.1 L |
| 3.00 | `Wiring for PA system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required.
Make Finolex / Polycab / Plaza / Havells.
2 x 1.5 sq.mm` | 2,150 | Metre | 63 ₹1.4 L | 58 ₹1.2 L | 60 ₹1.3 L |
| 4.00 | `Supply Installation Testing and Commissioning Supply, Installation, Testing and Commissioning of of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection.
Make:GST, Honeywell, Edward` | 1 | Each | 4,89,000 ₹4.9 L | 5,25,000 ₹5.3 L | 5,07,500 ₹5.1 L |
| 5.00 | `Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).
Make:GST, Honeywell, Edward` | 527 | Each | 3,400 ₹17.9 L | 3,325 ₹17.5 L | 3,275 ₹17.3 L |
| 6.00 | `Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).
Make:GST, Honeywell, Edward` | 35 | Each | 3,200 ₹1.1 L | 3,075 ₹1.1 L | 3,110 ₹1.1 L |
| 7.00 | `Supply Installation Testing and Commissioning of Analog Addressable type Active Repeater Fire Alarm Panel with Backlit LCD display, having controlls for reset, mute, accept, silence alarms and self test conforming to BS5839 standards with all labour and materials required to complete the job in all respect up to the entire satisfaction fo engineer-in-charge of work.
Make:GST, Honeywell, Edward` | 4 | Each | 94,000 ₹3.8 L | 95,000 ₹3.8 L | 96,500 ₹3.9 L |
| 8.00 | `Supply Installation Testing and Commissioning of Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.
Make:GST, Honeywell, Edward.` | 48 | Each | 4,950 ₹2.4 L | 4,700 ₹2.3 L | 4,570 ₹2.2 L |
| 9.00 | `Supply Installation Testing and Commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work.
Make:GST, Honeywell, Edward.` | 14 | Each | 7,200 ₹1.0 L | 6,850 ₹95,900 | 6,910 ₹96,740 |
| 10.00 | `Supply Installation Testing and Commissioning of minimum 1000 Mtr. Range Siren generator provided at the roof of the building with separate power suppl, relay etc..
Make: National/Kheraj.` | 1 | Each | 10,900 ₹10,900 | 9,500 ₹9,500 | 10,500 ₹10,500 |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
15 Jan 2026, 4:00 pmClosed
VISHWNATH KHICHI
ED - Karnal
Const. of 100 Bedded MCH building in the campus of Civil Hospital in Sonipat (Pdg. Nursing Call, Fire Alarm and PA system only).
2026_HRY_495184_1
2026DFB8C624 A24B 41E4 8293 B33A3473B8CF665BAR
Open Tender
Electrical Works
365 days
Sonepat
2 documents required · 2 mandatory
₹15,000
₹3.2 L
Yes
11 Mar 2026
6 Jan 2026
16 Jan 2026
7 Jan 2026
15 Jan 2026
7 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer Electrical Division PWD B&R Br., Karnal
Name of Work: Const. of 100 Bedded MCH building in the campus of Civil Hospital in Sonipat (Pdg. Nursing Call, Fire Alarm and PA system only)
DNITRs. 161.48 Lakhs
Name of the Bidder/ Bidding Firm / Company :
Sl. No. HSR Items / Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] BI01010001010000000000000515BI0100001113 Metre Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.08 MB
BOQ_573648.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid