| 1 | L1₹83.7 LAccepted-AOC 36MW INDUSTRIAL AREA INDUSTRIAL AREA PHASE 1 160002 CHANDIGARH CHANDIGARH 160002 | CHANDIGARH | CHANDIGARH | 160002 | ₹83.7 L Quoted ₹84.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹85.9 LRejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | ₹85.9 L | L2 | Rejected-AOC Rejected |
| 3 | L3₹91.5 LRejected-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | ₹91.5 L | L3 | Rejected-AOC Rejected |
| 4 | L4₹93.4 LRejected-AOC 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | ₹93.4 L | L4 | Rejected-AOC Rejected |
| 5 | L5₹1.0 CrRejected-AOC 303 GHS 88 SECTOR 20 PANCHKULA 134113 HARYANA | PANCHKULA | HARYANA | 134113 | ₹1.0 Cr | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | anand enterprises L3 | Amit Engineering L8 | Shikhar ji Enterprises L4 | V r traders L1 | PRAGATI ELECTROCOM PVT LTD L6 | R D Bansal L5 | Vijaypower Generators Limited L7 | SAGGI ELECTRIC COMPANY L9 | M/s Kamal Traders L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and shifting of existing pole steel Tubular pole of any size, PCC foundation & cross arms etc. complete all as specified and directed | 16 | Each | 200 ₹3,200 | 850 ₹13,600 | 150 ₹2,400 | 199 ₹3,184 | 775 ₹12,400 | 500 ₹8,000 | 3,000 ₹48,000 | 1,078 ₹17,248 | 500 ₹8,000 |
| 2.00 | Dismantling insulators any type, any size | 200 | Each | 50 ₹10,000 | 5 ₹1,000 | 10 ₹2,000 | 0.9 ₹180 | 8 ₹1,600 | 2 ₹400 | 150 ₹30,000 | 3 ₹600 | 10 ₹2,000 |
| 3.00 | Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use or deposited to mes store yard . all as directed by | 2 | Qtl | 500 ₹1,000 | 800 ₹1,600 | 150 ₹300 | 199 ₹398 | 1,240 ₹2,480 | 200 ₹400 | 6,000 ₹12,000 | 2,310 ₹4,620 | 500 ₹1,000 |
| 4.00 | Dismantling of ACSR or AAC conductors and setting aside for re-use or deposited to mes store yard . all as directed by Engineer in charge. | 13 | Qtl | 200 ₹2,600 | 1,000 ₹13,000 | 150 ₹1,950 | 999 ₹12,987 | 1,240 ₹16,120 | 200 ₹2,600 | 3,600 ₹46,800 | 2,310 ₹30,030 | 100 ₹1,300 |
| 5.00 | Material and labour for laying, jointing and testing HT underground electric power cable 3 core 95 sqmm size, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, (conforming to IS-7098 Part-I), ISI Marked, with aluminium conductor multi stranded, heavy duty,11000 Volts grade ( earthed ), in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc complete . all as directed:
Notes:
(a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc and HT cable end joints/ straight through joints shall be measured and paid separately.
(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.
(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. | 1,000 | RM | 1,000 ₹10 L | 1,050 ₹10.5 L | 920 ₹9.2 L | 999 ₹10.0 L | 1,070 ₹10.7 L | 1,075 ₹10.8 L | 1,035 ₹10.3 L | 1,021 ₹10.2 L | 980 ₹9.8 L |
| 6.00 | Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 50-95 Sqmm | 6 | Each | 7,000 ₹42,000 | 6,000 ₹36,000 | 4,500 ₹27,000 | 2,499 ₹14,994 | 2,325 ₹13,950 | 2,500 ₹15,000 | 6,069 ₹36,414 | 2,911 ₹17,466 | 3,000 ₹18,000 |
| 7.00 | Material and labour for laying, jointing and testing LT underground electric power cable 3.5 core 300 sqmm size, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, ISI Marked, with aluminium conductor multi stranded, heavy duty,1100 Volts grade ( earthed ), in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc complete . all as directed:
Notes:
(a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc and HT cable end joints/ straight through joints shall be measured and paid separately.
(b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses.
(c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor. | 850 | RM | 1,600 ₹13.6 L | 1,800 ₹15.3 L | 1,575 ₹13.4 L | 1,599 ₹13.6 L | 1,635 ₹13.9 L | 1,480 ₹12.6 L | 1,839 ₹15.6 L | 1,819 ₹15.5 L | 1,600 ₹13.6 L |
| 8.00 | All as per Item No 7 but 120 Sq mm, 3.5 core | 695 | RM | 780 ₹5.4 L | 784 ₹5.4 L | 660 ₹4.6 L | 759 ₹5.3 L | 730 ₹5.1 L | 652 ₹4.5 L | 807 ₹5.6 L | 813 ₹5.7 L | 730 ₹5.1 L |
| 9.00 | All as per Item No 7 but 95 Sq mm, 3.5 core | 761 | RM | 620 ₹4.7 L | 920 ₹7.0 L | 540 ₹4.1 L | 599 ₹4.6 L | 595 ₹4.5 L | 553 ₹4.2 L | 660 ₹5.0 L | 656 ₹5.0 L | 650 ₹4.9 L |
| 10.00 | All as per Item No 7 but 70 Sq mm, 3.5 core | 825 | RM | 450 ₹3.7 L | 785 ₹6.5 L | 425 ₹3.5 L | 499 ₹4.1 L | 487 ₹4.0 L | 445 ₹3.7 L | 538 ₹4.4 L | 536 ₹4.4 L | 450 ₹3.7 L |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
13 Nov 2025, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPLACEMENT OF OH LINE TO UG CABLES UNDER GE DEHRADUN
2025_MES_735577_1
0162/DDN/E8
Open Tender
Electrical and Maintenance Works
180 days
Dehradun
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE Dehradun
₹2.0 L
Yes
24 Feb 2026
16 Oct 2025
15 Nov 2025
16 Oct 2025
13 Nov 2025
6 Nov 2025
Amount
Dismantling and shifting of existing pole steel Tubular pole of any size, PCC foundation & cross arms etc. complete all as specified and directed
Dismantling insulators any type, any size
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use or deposited to mes store yard . all as directed by
Dismantling of ACSR or AAC conductors and setting aside for re-use or deposited to mes store yard . all as directed by Engineer in charge.
Material and labour for laying, jointing and testing HT underground electric power cable 3 core 95 sqmm size, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, (conforming to IS-7098 Part-I), ISI Marked, with aluminium conductor multi stranded, heavy duty,11000 Volts grade ( earthed ), in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc complete . all as directed: Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc and HT cable end joints/ straight through joints shall be measured and paid separately. (b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. (c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 50-95 Sqmm
Material and labour for laying, jointing and testing LT underground electric power cable 3.5 core 300 sqmm size, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, ISI Marked, with aluminium conductor multi stranded, heavy duty,1100 Volts grade ( earthed ), in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc complete . all as directed: Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc and HT cable end joints/ straight through joints shall be measured and paid separately. (b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. (c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor.
All as per Item No 7 but 120 Sq mm, 3.5 core
All as per Item No 7 but 95 Sq mm, 3.5 core
All as per Item No 7 but 70 Sq mm, 3.5 core
All as per Item No 7 but 50 Sq mm, 3.5 core
All as per Item No 7 but 25 Sq mm, 4 core
All as per Item No 7 but 25 Sq mm, 2 core
All as per Item No 7 but 16 Sq mm, 4 core
All as per Item No 7 but 16 Sq mm, 2 core
All as per Item No 7 but 10 Sqmm 4 Core
All as per Item No 7 but 10 Sqmm 2 Core
Supply and laying galvanised steel tubing 80 mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed.
All as per Item No 18 but 50 mm bore
Supply and fix HT 11 KV, drop out, out door type,Triple pole, gang operated air-break switch mounted on insulator and steel frame with operating mechanism from ground level, suitable for horizontal or vertical mounting fixed type complete with 12 insulators of rating upto 200 Amps
M & L and installation testing and comissioning of out door type Feeder Pillar box weather vermin proof factory made, front & back openable double door type with locking arrangement (including provn of 65 mm Godrej (Navtal) lock with 2 keys), fabricated out of 3.15mm thick CRCA sheet and 2mm thick inner enclouser CRCA sheet duly as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size complete with IP-54 protection having 433 volts, 3 phase, for 800 Amps rating 4 Nos, including all connections with copper strips, duly drilled holes for connections, RYB insulated with different colour code complete heat shrink insulated enclosed openable front & rear copper bus bar of Panel board shall be provided with danger notice plate with skull & bone sign, effectively PVC gasketed and sealed, glands to be provided at cable entries, including angle iron 50x50x6mm, 90 cm long with base and grouted in PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) complete all as specified and directed and comprising of as under :- (Note:-The cost of the PCC plateform deemed to be included in the qouted rates of above said item). Location - 3/8 GR main panel
Incoming :-(a) Air circuit breaker 415 Volt AC, 50 Hz, 800 Amp four pole breaking capcity 50 KA, manual drawout type, Microprocessor based. Make - c&S, Siemens
(b) Digital 3 lines LCD display panel mounted multifunction energy meter 96x96mm flush mounted accuracy class 1.0 complete with suitable size of CTs and copper control wiring
(c) Phase indicating lamp - 01 Set of three
Out going :-(a) MCCB 200 Amp FP breaking capcity 36 KA 415 Volt AC, 50 Hz, with adjustable type - 03 No
(b) MCCB 415 Volt AC, 50 Hz, 125 Amp FP breaking capcity 16 KA with adjustable type- 06 No
(c) MCCB 415 Volt AC, 50 Hz, 63 Amp FP breaking capcity 16 KA with adjustable type- 03 No
M & L and installation testing and comissioning of outdoor type Feeder Pillar box factory made, front & back openable double door type with locking arrangement (including provn of 65 mm Godrej (Navtal) lock with 2 keys), fabricated out of 3.15mm structure and 2mm enclouser CRCA sheet duly as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size complete with IP-54 protection having 433 volts, 3 phase, insulated bus bar for 600 Amps rating 4Nos, including all connections with aluminium strips, Pillar board shall be provided with danger notice plate with skull & bone sign, effectively PVC gasketed and sealed, glands to be provided at cable entries, including MS channel frame of ISMC 75 at the base of panel only for grouting purpose and grouted in PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) complete all as specified and directed and comprising of as under :- (Location : 14 DOGRA at point 'C' & 3/8 GR at point '2')
Incoming :-(a) MCCB 415 Volt AC, 50 Hz, 160 Amp four pole breaking capcity 36 KA, Adjustable type- 01 No
(b) Digital 3 lines LCD display panel mounted multifunction energy meter 96x96mm flush mounted accuracy class 1.0 complete with suitable size of CTs and copper control wiring - 01 No
(c) Phase indicating lamp - 01 Set of three
Out going :-(a) MCCB 415 Volt AC, 50 Hz, 125 Amp four pole breaking capcity 16 KA, Adjustable type- 01 No
(b) MCCB 415 Volt AC, 50 Hz, 63 Amp four pole breaking capcity 16 KA, thermal setting 70% - 100% - 03 No
M & L and installation testing and comissioning of outdoor type Feeder Pillar box factory made, front & back openable double door type with locking arrangement (including provn of 65 mm Godrej (Navtal) lock with 2 keys), fabricated out of 3.15mm structure and 2mm enclouser CRCA sheet duly as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size complete with IP-54 protection having 433 volts, 3 phase, insulated bus bar for 600 Amps rating 4Nos, including all connections with aluminium strips, Pillar board shall be provided with danger notice plate with skull & bone sign, effectively PVC gasketed and sealed, glands to be provided at cable entries, including MS channel frame of ISMC 75 at the base of panel only for grouting purpose and grouted in PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) complete all as specified and directed and comprising of as under :- (location : Panel No 3 near Qtr Gd 3/8 GR & panel at D for OTM 14 dogra, one for each unit)
Incoming :-(a) MCCB 415 Volt AC, 50 Hz, 160 Amp four pole breaking capcity 36 KA, Adjustable type- 01 No
(b) Digital 3 lines LCD display panel mounted multifunction energy meter 96x96mm flush mounted accuracy class 1.0 complete with suitable size of CTs and copper control wiring- 01 No
(c) Phase indicating lamp - 01 Set of three
Out going :-(a) MCCB 415 Volt AC, 50 Hz, 125 Amp four pole breaking capcity 16 KA, Adjustable type- 02 No
(b) MCCB 415 Volt AC, 50 Hz, 63 Amp four pole breaking capcity 16 KA, adjustable type - 04 No
M & L and installation factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet of size 750x500x400 mm duly painted with powder coating, simens grey/RAL fitted with four Nos aluminium bus bar of capacity 400 Amps duly mounted epoxy insulator , Cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB, 125 Amps, 4 pole, 16 KA, with adjustable type, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level, angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed including taking out old unserviceable bus bar chamber. (Location 3/8 GR- 10 Nos & 14 DOGRA - 18 Nos)
Material and labour in replacement for earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised strip 32x6 mm earth lead by means of bolts, nuts, check nuts and wathers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note: (i) If the desired earth resistance less than 05 Ohm is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI strip 32x6 mm dia earth lead and 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering upto 7.5 mtr is included in the rate quoted for this item.
All as per above item No.25 but in GI wire 4.0 mm Note: (i) If the desired earth resistance less than 05 Ohm is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4.0 mm dia earth lead and 15 mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering upto 7.5 mtr is included in the rate quoted for this item.
Supply & fix Expulsion type lightning arrestor having rated voltage 11 KV and discharge current 65 KA suitable for 11000 Volt complete all as specified and directed.
Supply and fixing PVC (Tharmoplastic) street light junction box 250X200X100mm, heavy duty with locking arrangement, single phase and neutral two Nos copper busbar and one No. MCB Single Pole 240 Volts 6 Amps complete.
Supply and fixing Pole mounted Junction Box as per sintex 250X200X100mm for fixing cable with provision of four Nos copper busbar with MCB SP 6 Amp.
M/L for route indicators made of PCC (1:2:4) type B1 (using 20mm graded aggregates) in rectangular blocks in sizes 60X20X20 cm burried in ground directly up to the depth of 45 cm and written the description details of U/G cable in red paint on top of the PCC block over yellow enamel paint complete all as directed and specified.
M&L for under ground pneumatic horizontal drilling of holes (HDD) under road, pavement, hard standing as required length at site by trenchless technology using ultra sound technique with necessary horizontal direction drilling machine . The contractor shall be conduct under ground scanning to detect existing HT/LT cable line , sewage line, OFC Cable etc to avoid damage. The entry/exist hole must be large enough to fit the drilling tool and the operator in it so they can aim the tool. The hole also must be deep enough that as the tool compacts the ground and the surface to be remain undisturbed. The depth of the starting bore pit depends on the type of the soil that is being worked in and how well it compacts. The operator shall aim the tool to the desire exit point and allow it to perform it function creating a bore hole under the ground without disturbing surfaces. The operator also should monitor the surface to make sure that, it is undisturbed. As the tool near to the exit point it is slowed down and the exit pit should be dug to locate both the tool and the bore. As the tool enters the exit pit the operator should choose either dig up the tool to retrieve it or reverses the tool back into the first bore pit to retrieve it including connected earth work, complete all as specified and directed.
Supply & Laying of High density polyethylene pipes (HDPE) of pressure rating HDPE Pipes PN 6 size 110mm (4") laid in trenches for the protection of HT UG Cable all as specified and directed
M&L for Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in soft/loose soil complete all as specified and directed.
M&L for Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
Supply & laying of un-reinforced precast concrete cable cover type -2 with peak size 450 mmx180 mmX40 mm laid in trenches for the protection of HT UG Cable all as specified and directed
Supply & laying of un-reinforced precast concrete cable cover CLASS LV , type -1 with flat size 250 mmx150 mmX40 mm laid in trenches for the protection of LT UG Cable all as specified and directed
M/s Kamal Traders (BID ID -3471372)
anand enterprises (BID ID -3469519)
Shikhar ji Enterprises (BID ID -3473060)
R D Bansal (BID ID -3473718)
PRAGATI ELECTROCOM PVT LTD (BID ID -3473422)
Vijaypower Generators Limited (BID ID -3473854)
Amit Engineering (BID ID -3472478)
SAGGI ELECTRIC COMPANY (BID ID -3473705)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
0162_Tender.pdf
Tender Documents • 1.53 MB
BOQ_823684.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid