Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹19.3 L+₹3.9 L (25.6%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹24.0 L+₹8.6 L (56.1%)Rejected-Finance | L3 | Rejected-Finance Due to L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
28 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAINT, REPAIRS TO COOLING APPLIANCES , LINK AC , REFRIGERATORS, DEEP FREEZERS, WATER AND DESERT COOLERS ALONGWITH OTHER CONNECTED MISC WORKS AT AFS BIDAR
2024_MES_686162_1
8134/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bidar
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Bidar
₹42,000
Yes
17 Feb 2025
30 Nov 2024
1 Jan 2025
30 Nov 2024
28 Dec 2024
14 Dec 2024
Amount
REFRIGERATORS Disconnecting and removing unserviceable Refrigerator of Capacity 190/210 litres from existing position finding out defects replacing unserviceable parts, checking leakages by charging with dry Nitrogen Gas, arresting leakage by Gas welding method, charging of refrigerant Gas and refixing the refrigerator in its original position complete all as specified and as directed. Make of existing Refrigerators :- Godrej/Electrolux Kelvinator/Samsung Note :- Cost of compressor, refrigerant and leak testing with Nitrogen will be measured and paid under respective items as ''Supply only".
Disconnecting and removing unserviceable Refrigerator of Capacity 280/300/308/310/320 litres from existing position finding out defects replacing unserviceable parts, checking leakages by charging with dry Nitrogen Gas, arresting leakage by Gas welding method, charging of refrigerant Gas and refixing the refrigerator in its original position complete all as specified and as directed. Make of existing Refrigerators :- Godrej/Electrolux Kelvinator/Samsung Note :- Cost of compressor, refrigerant and leak testing with Nitrogen will be measured and paid under respective items as ''Supply only".
Supply only hermatically sealed Compressor Unit suitable for refrigerator of Capacity 190/210 litres Single Phase suitable for Refrigerator complete all as specified and as directed. Make : LG/Hitachi/Voltas
Supply only hermatically sealed Compressor Unit suitable for refrigerator of Capacity 280/300/308/310/320 litres Single Phase suitable for Refrigerator complete all as specified and as directed. Make LG/Hitachi/Voltas
Disconnecting and removing unserviceable thermostatic switch and S & F new thermostatic switch suitable for existing 190 to 320 litres refrigerator complete all as specified and as directed.
Disconnecting and removing unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable for existing 190 t0 320 litres refrigerator complete all as specified and as directed.
Disconnecting and removing unserviceable timer switch, and S & F timer switch of same size and capacity suitable for existing 190 t0 320 litres refrigerator of existing make complete all as specified and as directed.
Disconnecting and removing unserviceable broken freezer door plastic, and S&F new door unit of same size and capacity suitable for existing 190/210 litres refrigerator of existing make complete all as specified and as directed.
Disconnecting and removing unserviceable broken freezer door plastic, and S&F new door unit of same size and capacity suitable for existing 280/300/ 308/310 /320 litres refrigerator of existing make. Complete all as specified and as directed.
Disconnecting and removing unserviceable fan with motor, and S&F fan Motor of same size and capacity suitable for 190/210/280/300/308/310/320 litres refrigerator of makes as per existing at site complete all as specified and as directed.
Disconnecting and removing unserviceable Over Load Protector Unit, and S&F Over Load Protector Unit of same size and capacity suitable for 190 to 320 litres refrigerator of existing makes complete all as specified and as directed.
REPAIRS TO WATER COOLER:- Disconnecting and removing electric and water supply connections connected to the water cooler of capacity 40/80 Liters capacity for replacement of Compressor , Fan Motor, Condenser coil or for leak testing by dry Nitrogen gas and charging the Refrigerant as required and fixing back in its original position connecting the electric and water connections testing and commissioning complete to the satisfaction of Engineer-in-Charge. Make :- Usha/Shriram Refrigeration/AC Cooler/Blue Star Notes :- (i) Cost of spares such as Compressor, refrigerant and nitrogen gas test will be measured and paid separately under respective Items as "Supply Only" (ii) Makes & Specifications of spare parts for replacement should be identical equivalent to the spares suitable for existing Water Coolers.
Supply only hermatically sealed Compressor Unit of Capacity suitable for 40 to 80 litres Single Phase for water coolers of existing make complete all as specified and as directed. Make :- Usha/Blue star
Supply only new fan motor unit, Single phase, 230 volts 50 Hz of same size and capacity suitable for 40 t0 80 Liters Water Cooler matching to existing make complete all as specified and as directed.
Supply only condenser Coil suitable for 40 t0 80Ltrs Single Phase for water coolers of existing make complete all as specified and as directed.
Disconnecting and removing unserviceable burnt thermostatic switch and S & F New thermostatic switch suitable for 40 t0 80 Liters Water Cooler of existing make complete all as specified and as directed.
Disconnecting and removing unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable for 40 to 80 Liters Water Cooler as per sample complete all as specified and as directed.
Disconnecting and removing unserviceable timer switch, and S&F new timer switch of same size and capacity suitable for 40 t0 80 Liters Water Cooler as per sample complete all as specified and as directed.
Disconnecting and removing unserviceable Over load protector unit, and S&F Over load protector unit of same size and capacity suitable for 40 t0 80 Liters Water Cooler as per sample complete all as specified and as directed.
Disconnecting and removing unserviceable Chromium plated push cock / lifting cock and S&F Chromium plated push cock / lifting cock of 15 mm dia of same size and capacity suitable for 40 t0 80 Liters Water Cooler as per sample.
Disconnecting and removing unserviceable ball valve of PVC high pressure with polythene float & fly nut and S&F ball valve of PVC high pressure with polythene float & of 15 mm dia and capacity suitable for 40 t0 80 Liters Water Cooler as per sample complete all as specified and as directed.
Disconnecting and removing unserviceable PVC connections connected to water cooler and S&F new PVC connection suitable for water cooler of capacity 40/80 litres water cooler as per sample complete all as specified and as directed.
DESERT COOLERS: Disconnecting and removing unserviceable Desert Cooler fan motor, and S & F fan motor working on 230 Volts, 50 HZ, 1/7 HP 1300 RPM AUE or Khaitan make for desert coolers complete all as specified and as directed
Disconnecting and removing unserviceable Desert Cooler vertical pump and S & F New vertical pump 1/66 HP, 230 Volts, 50 HZ. AUE or Khaitan make for desert coolers complete all as specified and as directed
Disconnecting and removing unserviceable Khas - Khas / wood wool pads and S & F new Khas - Khas / wood wool pads of same size and good thickness for desert cooler to the satisfaction of Engineer-in-Charge.
Taking out old damaged front grill unit and replacing same with new front grill as per sample. Suitable for desert cooler complete all as specified and as directed
Disconnecting and removing unserviceable Desert cooler body and S & F New desert cooler body made of iron of existing size, gauge and weight complete all as specified and as directed
Taking out faulty distributor system consisting of PVC elbow and PVC pipe and Supply and fix new water distributer 3 way consisting 3 Nos of PVC elbow and 1/2 inch heavy duty PVC Pipe of length up to 2 meters suitable for existing desert coolers complete all as specified and as directed
DEEP FREEZER :- Disconnecting and removing unserviceable burnt compressor unit from deep freezer, replacing the same with new hermatically sealed compressor unit along with its connected items, including carrying out leak testing by dry nitrogen gas, charging of refrigerant after ensuring leak proof conditioned, Testing and commissioning of deep freezer of capacity 200/210 litres complete all as specified and as directed. Make :- Blue Star
Disconnecting and removing unserviceable burnt compressor unit from deep freezer, replacing the same with new hermatically sealed compressor unit along with its connected items, including carrying out leak testing by dry nitrogen gas, charging of refrigerant after ensuring leak proof conditioned, Testing and commissioning of deep freezer of capacity 300/310 litres complete all as specified and as directed Make :- Blue Star
Disconnecting and removing unserviceable thermostatic switch and S & F new thermostatic switch suitable for 200 to 310 litres deep freezer complete all as specified and as directed
Disconnecting and removing unserviceable burnt Fan motor unit from the deep freezer and S&F New Fan Motor unit , Single phase, 230 volts 50 Hz of same size and capacity suitable for 200/210 litres deep freezer as per sample complete all as specified and as directed
Disconnecting and removing unserviceable burnt Fan motor unit from the deep freezer and S&F New Fan Motor unit , Single phase, 230 volts 50 Hz of same size and capacity suitable for 300/310 litres deep freezer as per sample complete all as specified and as directed
Disconnecting and removing unserviceable starting relay unit, and S&F New Relay unit of same size and capacity suitable for 200 to 310 litres deep freezer complete all as specified and as directed
Disconnecting and removing unserviceable Timer switch, and S&F Timer switch of same size and capacity suitable for 200 to 310 litres deep freezer complete all as specified and as directed
Disconnecting and removing unserviceable broken freezer door plastic, and S&F New Door unit of same size and capacity suitable for 200 to 310 litres deep freezer complete all as specified and as directed
Disconnecting and removing unserviceable fused electric bulb, and S&F Bulb Unit of same size and capacity suitable for 200 to 310 litres deep freezer complete all as specified and as directed
Disconnecting and removing unserviceable Over Load Protector Unit, and S&F Over Load Protector Unit of same size and capacity suitable for 200 to 310 litres deep freezer complete all as specified and as directed
SPLIT TYPE AC's :- Disconnecting and removing unserviceable Condenser Fan Motor and S & F New Condenser Fan Motor suitable for 1.5 Ton Outdoor Split Type Air Conditioning Unit complete all as specified and as directed.
Description all as per Sl item No 40 here-in-above but of capacity 2.0 Ton
Description all as per Sl item No 40 here-in-above but of capacity 3 Ton
Disconnecting and removing unserviceable Condenser Coil Unit and S&F new Condenser Coil Unit consisting of Copper tubing suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as specified and as directed
Description all as per Sl item No 43 here-in-above but of capacity 2 Ton
Description all as per Sl item No 43 here-in-above but of capacity 3 Ton
Disconnecting and removing unserviceable Suction Valve and S & F new Suction Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as specified and as directed
Description all as per Sl item No 46 here-in-above but of capacity 2.0 Ton
Description all as per Sl item No 46 here-in-above but of capacity 3 Ton
Disconnecting and removing unserviceable discharge Valve and S & F new Discharge Valve made of Brass suitable for 1.5 Ton Outdoor Unit of Split Type Air Conditioning complete all as specified and as directed
Description all as per Sl item No 49 here-in-above but of capacity 2.0 Ton
Description all as per Sl item No 49 here-in-above but of capacity e Ton
Disconnecting and removing unserviceable PCB/ Mother Board Unit and S & F new PCB Mother Board along with Remote Control Unit suitable for 1.5 Ton Split Type Air Conditioner of Make LG / BLUE STAR / VOLTAS / HITACHI complete all as specified and as directed
Description all as per Sl item No 52 here-in-above but of capacity 2.0 Ton
Disconnecting and removing unserviceable PCB and S & F new PCB along with Remote Control Unit suitable for 1.5/2 Ton inverter type split AC of Make LG / BLUE STAR / VOLTAS / HITACHI complete all as specified and as directed
Supply and Charge Refrigerant (R-22)/F-22/R-410A/R-134/R-32 suitable for existing 1.5/2/3 Ton Capacity Split / Window type air conditioning unit complete all as specified and as directed
Disconnecting and removing unserviceable Running/Starting Capacitors from the Outdoor units of Split Type AC Unit 1.5/2/3 Ton Capacity and S&F New Capacitors of capacity 50 MFD 230 Volts, ISI Marked complete all as specified and as directed.
Description all as per Sl item No 56 here-in-above but of capacity 55 MFD.
Disconnecting and removing unserviceable /broken Fan Blade from the Outdoor units of Split AC Unit 1.5 Ton Capacity and S&F New Fan Blade Unit complete suitable for existing AC Unit. complete all as specified and as directed
Description all as per Sl item No 58 here-in-above but of capacity 2 Ton.
Disconnecting and removing unserviceable Electrical Connectors and S&F New Electrical Connectors 3 Pole suitable to connect Single Phase Power Supply between Indoor and Outdoor Unit of Capacity 1.5 / 2/3 Ton complete all as specified and as directed
Disconnecting and removing old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 1/2" dia and connecting along with Insulation Sleeves to the existing position incl leak testing complete all as specified and as directed
Description all as per Sl Item No 61 here-in-above but of capacity 1/4" dia
Description all as per Sl Item No 61 here-in-above but of capacity 5/8" dia
Disconnecting and removing unserviceable compressor from Split AC Outdoor of capacity 1.5 Ton Capacity and Supply and fix New hermatically sealed compressor suitable for LG/Hitachi/Voltas/Blue star Split AC's including Vacuuming, Leak testing & Gas charging and testing complete all as specified and as directed.
Description all as per Sl item No 64 here-in-above but of capacity 2.0 Ton Capacity
Description all as per Sl item No 64 here-in-above but of capacity 3.0 Ton Capacity
Disconnecting and removing old unserviceable Outdoor Stand and S&F New Outdoor Stand made of Iron bracket to accommodate the air conditioner along with fixing materials complete all as specified and as directed
Disconnecting and removing unserviceable / burnt out Copper Cable between Indoor & Outdoor Unit and S&F PVC Insulated, PVC Sheathed, Multi-stranded Copper Cable 3 Core 2.5 Sqmm, ISI Marked, 1100 volts Grade and connecting to the unit along with necessary fixing materials complete all as specified and as directed Make :- Polycab / Finolex / Havells
Description all as per Sl Item No 68 here-in-above but of 3 Core, 4 Sqmm size
Description all as per Sl Item No 68 here-in-above but of 3 Core, 6 Sqmm size
Disconnecting and removing unserviceable Blower Unit of Indoor unit Split type AC Conditioner and S&F Blower Unit of same make, size and capacity suitable for 1.5 Ton for Air Circulation complete all as specified and as directed
Description all as per Sl Item No 71 here-in-above but of capacity 2.0 Ton.
Description all as per Sl Item No 71 here-in-above but of Capacity 3.0 Ton.
Disconnecting and removing damaged Flexible PVC Drain Pipe of dia 25mm and S&F New Standard Flexible PVC Drain Pipe of dia 25mm for capacity 1.5 ton, 2.0 ton & 3 Ton capacity. complete all as specified and as directed
Supply and fixing in replacement, condensed water tray of existing size and make for split AC Indoor unit. complete all as specified and as directed
Disconnecting and removing defective / damaged Industrial Plug & Socket Board and supply & fix Industrial Plug & Socket controlled by 01 No 20 Amp MCB Single Pole ISI Marked in and including sheet metal enclosure suitable for 1.5/2 Ton capacity complete all as specified and as directed
Disconnecting and removing Cable connections by Pump down the refrigerant and removing the Copper Pipe along with all connected items carefully from the existing indoor and out door units and from Outdoor Unit of tonnage 1.5/2/3 Ton including stabilizer from the existing positions and shifting the AC unit at new place and refixing the outdoor and indoor units with necessary copper tubing including topping up of gas and connecting stabilizer etc for its proper functioning complete all as specified and as directed
Carrying out Leak Proof Test for detection of leakage of gas from the cooling unit & Copper Tubing for Indoor/Outdoor Unit of Air conditioner, Refrigerator, Water Cooler with liquid nitrogen gas and arresting by gas welding method complete and charging of refrigerant into the Air conditioner/Refrigerator/Water Cooler complete all as specified and as directed Note :- The cost of refrigerant will be measured and paid separately under the respective item of Schedule A.
S&F in replacement of split type AC indoor unit of capacity 1.5 Ton suitable for existing outdoor unit including remote and other misc items complete all as specified and as directed. Note : The old/unserviceable indoor unit shall be deposited to MES store yard.
Description all as per item No 79 here-in-above but of capacity 2 Ton.
S&F in replacement of split type AC outdoor unit of capacity 1.5 Ton suitable for existing indoor unit including other misc items complete all as specified and as directed. Note : The old/unserviceable outdoor unit shall be deposited to MES store yard.
Description all as per Sl item No 81 here-in-above but of capacity 2 Ton.
VOLTAGE STABILAISER :- Disconnecting and removing defective / burnt control center tapped transformer (12 V - 0 12 V ) connected to PCB; and Supply and fix new Transformer for voltage stabilizer of capacity 5 KVA capacity complete all as specified and as directed
Description all as per Sl item No 83 here-in-above but for capacity up to 4 KVA
Description all as per Sl item No 83 here-in-above but for capacity up to 3 KVA
Disconnection and removing PCB (Printed Circuit Board) complete with components and Supply & Fix new PCB complete with components of 5 KVA Voltage stabilizer complete all as specified and as directed
Description all as per Sl item No 86 here-in-above but for capacity up to 4 KVA
Description all as per Sl item No 86 here-in-above but for capacity up to 3 KVA
Disconnecting and removing faulty relay and Supply and fix new relay for voltage stabilizer 3.0 KVA / 4.0 KVA / 5.0 KVA capacity complete all as specified and as directed
Description all as per Sl item No 89 here-in-above but for capacity 2.5 / 2.0 / 1.0 / 0.5 KVA
Disconnecting and removing unserviceable voltmeter 0 to 300 Volts, Round / Square type. Supply and fix the same type voltmeter 0 to 300 Volts in Voltage stabilizer complete all as specified and as directed
Disconnecting and removing burnt connector and Supply and fix electric connector 20 Amps in Voltage stabilizer complete all as specified and as directed
S&F in replacement of dessert cooler of plastic body, electric fan driven (Single phase) having normal air flow capacity of min 3500 Cum/ hour complete with exhaust fan motor of 1400 RPM and submersible water lifting pump and water tank capacity 70 Litre complete all as specified and directed. Note : The old/unserviceable desert cooler is deposited to MES store yard.
Disconnecting and removing u/s single pole contactor 30 Amps & Supply and fix new single pole contactor 30 Amps, coil voltage 220-230 Volts AC suitable for split AC 1.5/2 Ton capacity complete all as specified and as directed
om sai enterprises (BID ID -3195416)
RASI AND COMPANY (BID ID -3200363)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .