Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Managing Director
IMPACT Kerala Ltd
Pls refer tender documents
2025_IKL_823781_1
IKL/CTM/2025/14
Open Tender
Civil Works - Buildings
Item Rate
365 days
Koorachund GP
Pls refer tender documents
6 documents required · 6 mandatory
₹6,510
₹50,000
1 Jan 2026
1 Jan 2026
24 Jan 2026
1 Jan 2026
22 Jan 2026
1 Jan 2026
Civil Building Works
2.28.1:Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD381891/2025-2026:60.7.8 DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site
OD381914/2025-2026:60.7.9 RR with Departmental. Stone - Random rubble masonry using departmental rubble in foundation and plinth including through and bond stone and levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
OD381962/2025-2026:Modified 60.7.9 RR with Departmental. Stone - Random rubble masonry using departmental rubble above plinth level and upto floor five level including through and bond stone and levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
OD259100/2025-2026:Providing and anchoring 12 mm dia rebar in rock (150mm depth in rock and 200mm depth in concrete ) using chemical anchoring compound (RE100) of approved quality and make, including the cost of all materials, labour, and related charges complete.
OD259111/2025-2026:Providing and anchoring 16 mm dia rebar in rock (150mm depth in rock and 200mm depth in concrete ) using chemical anchoring compound (RE100) of approved quality and make, including the cost of all materials, labour, and related charges complete.
OD340034/2025-2026:Modified 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Excess or less cement used as per design mix will not be payable or recoverable separately)
OD340048/2025-2026:Modified 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Excess or less cement used as per design mix will not be payable or recoverable separately
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
OD259102/2025-2026:Applying Antitermite treatment on flooring using second generation chemicals which is ecofriendly and nil harm ful for human beings and pet animals which control the pests including all cost and labour charges etc complete
4.11: Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
OD259099/2025-2026:Modified Item Code 4.13 -Applying a coat of Inertol Poxitar Coal tar epoxy coating per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
50.6.7.1:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
50.6.7.2:Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.33.1:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
OD259115/2025-2026:Applying two coat of clear coat on random rubble surface and including all cost and conveyance of all materials and labour charges etc . complete.
5.30:Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.
OD259109/2025-2026:Providing and fixing fibre glass mesh of 145 GSM including cost and conveyance of all material and labour charge etc complete.
OD259110/2025-2026:Providing water cutting to bottom edge side of slab/sunshade by 25mm wide and 15mm thick in cement mortar 1:3 including cost and conveyance of all materials, labour charges etc. Complete.
21.1.1.3:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.1.2.3:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micorn)
OD259114/2025-2026:Modified 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With pin headed glass panes of 4.0 mm thickness
OD259107/2025-2026:Providing and fixing 4 mm thick ACP, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.
21.8.1:Filling the gap in between aluminium frame & adjacent RCC/ Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawing and direction of Engineer-in -Charge complete.Upto 5 mm depth and 5 mm width
OD259112/2025-2026:Providing and fixing Aluminium sliding door accessories and fittings of approved quality with necessary stainless steel screws etc.
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
9.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
50.9.1.2:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) using good quality Pincoda wood
50.9.2.2:Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required sized with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer in-charge using Pincoda wood
50.9.4.2:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Pincoda wood
9.7.7.1:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:4 mm thick glass pane (weight not less than 10kg/sqm).
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
50.9.15.5:Providing and fixing iron hooks and eyes: 100 mm
OD259105/2025-2026:Modified 9.74.3 Providing and fixing Seamless tower bolts with necessary screws etc. complete:152x10mm
OD259116/2025-2026:Modified 9.74.4 Providing and fixing Seamless tower bolts with necessary screws etc.complete:102x10 mm
9.76:Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
13.116:Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
9.121:Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.1:Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
OD259104/2025-2026:Modified 11.48.2 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 300x300 mm.
OD259101/2025-2026:Providing and fixing PVC Tile beading in the edges and corners of tile work including cost conveyance labour charges etc complete.
8.2.2.2:Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm
10.26.1:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD259108/2025-2026:Modified 13.52.1 Finishing with Polyurethane paint (One coat) at all locations prepared and applied as per manufacturer's specifications including epoxy based primer (Two Coats), Manual preparation of surface including wire brush and papering, etc. complete. On Steel works.
22.6:Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
OD259113/2025-2026:Modified 12.48 Providing & fixing roof ceramic tile of approved size as per approved pattern on steel frame work complete(steel frame work to be paid separately)
OD259103/2025-2026:Modified 12.49 Providing & laying Ceramic ridge tile of approved pattern on steel frame work complete (steel frame work to be paid separately ).
Civil Yard Works
2.7.3:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD340055/2025-2026:Modified 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Excess or less cement used as per design mix will not be payable or recoverable separately
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
Retaining Wall
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.3:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD340066/2025-2026:Modified 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Excess or less cement used as per design mix will not be payable or recoverable separately
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
OD340475/2025-2026:60.7.8 DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site
OD381985/2025-2026:60.7.9 RR with Departmental. Stone - Random rubble masonry using departmental rubble in foundation and plinth including through and bond stone and levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
OD339649/2025-2026:60.6 PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.
Septic Tank
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD340074/2025-2026:Modified 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Excess or less cement used as per design mix will not be payable or recoverable separately
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineeri-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
22.4.1:Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
OD259136/2025-2026:Supplying and fixing Ductile iron heavy duty (62 Kg) manhole covers of size 600x600mm
Dry Well for Septic Tank (1.6m inner dia, 1.80m height - including freeboard)
OD259135/2025-2026: Modified 23.6 Supplying, filling, spreading & leveling stone aggregate of size range 20 mm to 40 mm, in the pit in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
OD340081/2025-2026:Modified 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All work upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum Note: Excess or less cement used as per design mix will not be payable or recoverable separately
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD259131/2025-2026:Providing and fixing 1600mm dia, 1800mm high and 120mm thick NP3 pipe for the soak pit including all cost of material, labour charges etc. complete.
OD259134/2025-2026:Cutting holes in RCC wall for passing pipe including all cost of labour. machinary etc. complete
50.6.3.1:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
OD259132/2025-2026:Modified 2.27 Supplying and filling in soak pit with broken bricks, including labour charge and material cost etc. complete.
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
OD259133/2025-2026:Supplying and fixing Ductile iron heavy duty (62 Kg) manhole covers of size 600x600mm
Ferrocement Rainwater tank (9500L) Ferrocement (At ground level) - @Rs 13/L
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Borewell (Considering Rock Boring )
OD259119/2025-2026:Borewell (Considering Rock Boring )
Interior
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
OD259168/2025-2026:Signage board:Providing and fixing signage board (Male/ Female/D Toilet) as per design intent. Signage board to be finished with 24 guage SS plate background, black sticker to be fixed on SS plate. Signage board to be fixed on existing wall. Including cost and conveyance charges of all materials, labour charges etc.size 250mm x 200mm/Nearest
OD259169/2025-2026:SS Name Board IProviding and fixing name board as per design intent. Name board to be finished with 24 guage SS plate background, 6 cm height sticker letter (OFFICE) to be fixed on SS plate. Name board to be fixed on existing wall. Including cost and conveyance charges of all materials, labour charges etc. Size; 350x120mm/ nearest
OD259170/2025-2026:SS Name Board IIProviding and fixing name board as per design intent. Name board to be finished with 24 guage SS plate background, 6 cm height sticker letter (NO ADMISSION) to be fixed on SS plate. Name board to be fixed on existing wall. Including cost and conveyance charges of all materials, labour charges etc. Size; 650x120mm/ nearest
PHE Work
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
50.17.1.5:Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
18.74.2:Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, Collar and bush approved quality and colour .15 mm nominal bore with 45 cm length
18.51.1:Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
OD259148/2025-2026:Supplying,fixing & testing of Concealed Stop Cock, CP Over Head Shower & Arm of approved quality Make : Jaquar/Hindware/Parryware/Equivalent
17.23:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
OD259167/2025-2026:Providing and fixing CP Urinal Push Cock including connection pipe of approved quality. Make:Jaquar/Cera/Hindware/Parryware/Viking/Equivalent
OD259157/2025-2026:Providing and fixing Urinal Partition of approved quality. Make:Jaquar/Cera/Hindware/Parryware/Equivalent
17.73.2:Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighting not less than 190 gms
OD259147/2025-2026:OD Derived from 18.22.1 Supplying and Fixing CP Robe Hook of approved Quality Make:Jaquar/Cera/Hindware/Parryware/Equivalent
OD259151/2025-2026:OD Derived from 17.72 Supplying and Fixing CP Towel Ring fixed with SS screws on to the toilet. Make:Jaquar/Cera/Hindware/Parryware/Equivalent
OD259144/2025-2026:Supplying and Fixing CP Soap Dish of approved quality Make:Jaquar/Cera/Hindware/Parryware/Equivalent
OD259153/2025-2026:Providing and fixing of Soap Dispenser of approved quality. Make:Jaquar/Cera/Hindware/Parryware/Equivalent
OD259150/2025-2026:Observed Data Providing and fixing sanitary fixtures of Handicapped Toilet including 1No EWC & Cistern complete fittings & seat cover, 1No Wall Hung Wash Basin, 1 Pair of mounting brackets, 1Nos Elbow Operated Pillar Cock ,CP Waste Coupling, 1Nos Hinged Rail & 4 Nos of Grab Rails etc designed for people with special needs with as per manufactures specification including cutting and making good the walls and floors wherever required as directed by Engineer - in charge.
50.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
50.18.8.8.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
OD259154/2025-2026:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge- Internal work- Exposed on wall 63 mm dia 6kg/cm2
OD259160/2025-2026:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge- Internal work- Exposed on wall 75 mm dia 6kg/cm2
OD259141/2025-2026:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge- Internal work- Exposed on wall 110 mm dia 6kg/cm2
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.17.2:Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall
50.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
50.18.9.8.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
OD259146/2025-2026:Providing , fixing , testing and commissioning PVC Multy Inlet (110x75x50x50x50) Floor Trap of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required
OD259143/2025-2026:Providing , fixing , testing and commissioning pvc "P" trap with multy inlet or single inlet connection of required sizes of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required
OD259137/2025-2026:Providing and fixing PVC Adapter Boss of approved quality 110 x 63 mm
OD259163/2025-2026:Providing and fixing PVC Adapter Boss of approved quality 110 x 50 mm
OD259155/2025-2026:Providing and fixing two piece CP , air tight floor clean out plug of approved quality . 125mm square frame with 100 mm dia openable circular lid .
OD259139/2025-2026:Providing, fixing, testing and commissioning at site C.P. or stainless steel Grating Cover with protection from cockroaches of matching size of multi inlet or "P" trap complete in all respects. 5" Frame with 4" Openable Lid/Grating
OD259159/2025-2026:Providing and fixing GI slotted rail of approved design. projecting 75 mm outside the wall surface and fixed on wall with 2 nos, 6/8 mm dia expansion hold fasteners, including drilling necessary holes in brick wall / CC / RCC surface and the cost of bolts included. The pipes shall be fixed to the already fixed brackets with the help of 8 mm galvanised GI "U" bolts of specified shape and shall be fixed with GI nuts, bolts, & washers of suitable size, one bolts on each side of the pipe.
OD259145/2025-2026:OD Derived Supply and fixing of 600x600mm DI MD (B-125) manhole cover of approved quality.
OD259161/2025-2026:OD Derived from 19.4.1.1 Providing and fixing square-mouth gully trap class complete with 100mm C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg including PVC P Trap of 4" dia as per standard design: 4" x 4" size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
50.18.9.20.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow
50.18.9.20.2:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
50.18.9.20.9:Providing and fixing PVC moulded fitting / accessories for Rigid PVC pipes, including jointing with PVC solvent cement-63 mm dia Socket /coupling
OD259156/2025-2026:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Y
50.18.9.20.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
50.18.9.21:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
50.18.9.21.2:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
50.18.9.21.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
50.18.9.21.9:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.2:Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.8:Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
50.18.9.22.11:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer
OD259158/2025-2026:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Y
18.8.2:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
18.8.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes
18.8.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal dia pipes
18.7.2:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes
18.7.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal dia pipes
18.7.4:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal dia pipes
18.7.5:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal dia pipes
18.9.3:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal dia pipes
18.9.5:Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal dia pipes
OD259152/2025-2026:Providing and fixing Gun Metal / Forged Brass Ball valve of approved quality of following sizes. 20mm dia, Make: Zoloto/SKS/Cim/Equivalent
OD259164/2025-2026:Providing and fixing Gun Metal / Forged Brass Ball valve of approved quality of following sizes. 25mm dia, Make: Zoloto/SKS/Cim/Equivalent
OD259142/2025-2026:Providing and fixing Gun Metal / Forged Brass Ball valve of approved quality of following sizes. 32mm dia, Make: Zoloto/SKS/Cim/Equivalent
OD259140/2025-2026:Providing and fixing Gun Metal / Forged Brass Ball valve of approved quality of following sizes. 40mm dia, Make: Zoloto/SKS/Cim/Equivalent
18.19.3.2:Providing and fixing gun metal non-return valve of approved quality (screwed end): 40 mm nominal boreVertical
OD259138/2025-2026:Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant with necessary form work, staging, tools, etc., ( if required), RCC Slabs (Up to 30 cm Thickness), 50mm - 75 mm
OD259162/2025-2026:Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant with necessary form work, staging, tools, etc., ( if required) RCC Slabs (Up to 30 cm Thickness), 75mm -125mm
OD259165/2025-2026:Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant with necessary form work, staging, tools, etc., ( if required), RCC Beams (Up to 30 cm Thickness), 50mm - 75 mm
OD259166/2025-2026:Drilling/Core Cutting of required dia outlets using low vibration mechanical means. Cost to include closing of core cut using appropriate sealant with necessary form work, staging, tools, etc., ( if required), RCC Beams (Up to 30 cm Thickness), 75mm -125mm
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
OD259149/2025-2026:Supplying, Installation, testing, and commissioning of bore well submersible Pump suitable for 45mtr to 158mtr head. Discharge from 100lpm to 28lpm including starter. Make: Lubi/Kirloskar/KSB/Wilo Equivalent.
Fabrication Works
OD259130/2025-2026:Derived 10.16.1: Steel work in tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position , including welding and bolted with special shaped washers etc. complete. Hot finished welded type tube.
OD259127/2025-2026:Derived 10.20:Providing and fixing Anchor bolts and connection bolts etc. complete.
OD259128/2025-2026:Derived10.25.2: Providing and fixing chequered plate of required thickness, including cutting, hoisting, fixing in position as required., including all cost of materials, labour charges etc, complete. Excluding the cost supports and frames.
OD259121/2025-2026:Derived 10.25.2: Supply, Fabrication and Installation of Steel tubular sections for gates, gratings and frame work etc. including labour part, cartage, cutting, hoisting, fixing in position and welding etc. as required, as suggested by the engineer in charge.
OD259126/2025-2026:Derived 10.25.2: Supply, Fabrication and Installation of Steel built up sections for compound wall frame,louvers etc. including labour part, cartage, cutting, hoisting, fixing in position and welding etc. as required, as suggested by the engineer in charge.
OD259122/2025-2026:Derived 16.70.1: Providing and fixing G.I Perforated sheet 1.6 mm thick including cutting, welding, fixing to steel frames as per the direction of Engineer-in-Charge.
OD259129/2025-2026:Providing and fixing jali works using 5 mm thick MS sheet including CNC cutting as per the drawing fixed to MS frame as directed by engineers incharge. Area : 46.65 sqcm
OD259124/2025-2026:Providing and fixing jali works using 5 mm thick MS sheet including CNC cutting as per the drawing fixed to MS frame as directed by engineers incharge. Area : 204.37 sqcm
OD259120/2025-2026:Derived 12.50: Providing and fixing aluminium plain sheet 1 mm thickness including all cost of conveyance and labour charges etc as specified and as directed by the Engineer-in-Charge. The sheet shall be fixed using self drilling/self tapping screws and excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
OD259123/2025-2026:Providing and fixing 160 mm standard width PVC rain water Gutter Pipe with clamp and all necessary accessories required for supporting to the wall including cost of labour and making necessary connections with rain water pipes as specified and as directed by the Engineer- in-Charge. Make: Aquastar/Equivalent
50.18.9.18.2:Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wall
OD259125/2025-2026:Derived 13.52.1 Finishing with Polyurethane paint (One coat) at all locations prepared and applied as per manufacturer's specifications including epoxy based primer (Two Coat), Manual preparation of surface including wire brush and papering, etc. complete. On Steel works
LPG Crematorium Equipment
OD385084/2025-2026:Constructing MS Chimney foundation of size 2m*2m*2m, in M25 concrete as per technical specification. Rate is inclusive of earth work, P.C.C ,centering shuttering , reinforcement and 25mm dia foundation bolt nut as per requirement including labour charges all complete as per the drawings, and as directed by the Engineer-in-Charge.
OD385090/2025-2026:Providing and laying Gas line using MS pipe including fixing of 50mm and 15mm dia non-return valves, 1/2" Suraksha hose,1/2" hydraulic hose, 1/2" LPG and brass adaptor ,1/2” and 2” regulators ,1/2" pressure gauge , 100KW high pressure burner and 1" LPG mass weighing machine. Safety features such as safety controller PLC based control, that is able to prevent the charging door from being opened unless the temperature in the primary chamber is below the set point or when the burners are in ignited mode. Provision for automatically shutting down the fuel flow to the burner at the end of cremation cycle also need to be provided all complete as per the drawings and as per requirement including painting the gas lines using red and yellow paint and labour charges etc. complete as directed by the Engineer-in-Charge.
OD385100/2025-2026:Providing and fixing MS Chimney total 30m height on RCC Chimney foundation , as per CPCB norms and State PCB norms, using MS flange bottom outer dia 1.5m and inner dia 1m and MS sheet diameter varying from 1m to .8m meters for a height of 6m, from 0.8m to 0.6m meters for a height of 6m , from 0.6m to 0.325m meters for a height of 6m and topmost part with diameter 0.325m for a height of 12m. MS sheet of thickness minimum 8mm for a height of 6m and 6mm for the remaining height to be used with inner lining lagged with high alumina refractory in the conical area . Providing and fixing full length MS ladder using MS pipe and rods -at 11m with platform and remaining 18m ladder to be provided. Fixing connection to chimney using 325 mm dia MS pipe need to be provided and sampling port at 11m from the chimney bottom. Lightning arrestor of 50m capacity using GI strip 25mm x3mm need to be provided and fixed using 32mm PVC pipe at the top of the chimney and should be connected to the earthing pit in the ground. The rate is inclusive of earthing compound but exclusive of charge for construction of earthing pit. Providing and fixing accessories such as nut bolt washers of appropriate sizes ,8mm asbestos rope and BI metal 4" dia (0-300 range) dial thermometer .Rate is inclusive of painting the chimney with black paint including primer and thinner, carriage of materials, cost of installation, erection including labour charges all complete as per the drawings, and as directed by the Engineer-in-Charge.
OD385104/2025-2026:Providing and fixing purification tank using MS sheet of minimum size 2.55 m x 1.26 m x 1.26 m. Providing and fixing ventury scrubber of dia 750 x 1500 (Top Dish - 200 MM), MOC - SS 304, spray header, spray nozzle , CRI valves,MS flanges,1HP Pressure Pump ,1" dia drain Valve and stand for scrubber. Providing and fixing cyclon separator of dia - 800 x 1500 (Top Dish - 200 MM),MOC - SS 304, stand for cyclone seperator and mist eliminator of dia - 300 x 500 (Top Dish - 200 MM ).Providing and fixing centrifugal type 7.5 HP blower with dynamically balanced impeller made of SS 304 and driven by belt and En8 shaft of inlet size of dia 10"flange and outlet size 8" with outlet orientation vertical anticlockwise from the drive end and a motor speed of 2880 RPM . Providing and fixing 200 mm MS pipe and MS bend, 1000 litre water tank of good approved quality with appropriate valves and fittings all complete as per the drawings. Rate is inclusive of painting the tank with black paint including primer and thinner, carriage of materials and labour charges etc complete as specified and as directed by the Engineer-in-Charge.
OD385107/2025-2026:Secondary Chamber Separate secondary chamber of minimum outside dimension 0.8 m x 0.8 m x 0.8 m and inner dimension 0.35 m x 0.35 m x 0.35 m with secondary chamber stand of outside dimension 0.85 m x 0.85 m x 0.9 m made out of MS sheet of minimum plate thickness of 5 mm connected by MS angles and provided with refractory lining with insulation brick and able to withstand 1400 deg C. Separate duct arrangement with MS duct having minumum dimension 4.0 m x 0.45 m x 0.45 m and provided with refractory lining with insulation brick and able to withstand 1400 deg C complete including black colour painting inclusive of primer and thinner including all labour, installation, transportation charges etc complete. as per the direction of Engineer- in-Charge
OD385111/2025-2026: Electrical Items For Gas crematorium with PVC PIPE 25 MM BEND 25 MM 3 WAY JTN BOX 25 MM TEE 25 MM FLEXIBLE HOSE 25 MElectrical Items For Gas crematorium with PVC PIPE 25 MM BEND 25 MM 3 WAY JTN BOX 25 MM TEE 25 MM FLEXIBLE HOSE 25 MM PHASOR CLAMP 25 MM GRIP 6 MM SCREW 25 MM / 1" SCREW DRY WALL 1 1/2" TIE 250 INSULATION TAP R B G Y COPPER 5 KG ANCHOR BOLT 6 MM C PVC PIPE 1 " CPVC ELBOW 1 " CPVC TEE 1 " CPVC 1" 45 UNION CPVC 1" VALVE CPVC 1" MTA CPVC 1" FTA CPVC 1" TUFFLON TAPE CPVC COUPLING 1" PVC FTA 1" VALVE PVC 1" PIPE PVC 1" ELBOW PVC 1" PVC TEE 1" CPVC SOLVENT PVC SOLVENT FOOT VALVE 1" WIRE 2.5 MM WIRE 1.5 MM WIRE 4 KG THERMO COUPLE LABOUR PANEL BOARD --3 PHASE CONTACT - 4 NOS TIMER RELY 25 A CAPASITOR - 3.0 KVAR & 2.7 KVAR NC & NO - 4 POLE - 1 NO AND 2 POLE - 2 NOS 32 A ISOLATOR - 4 POLE MCB CONNECTORS - 10 A - 14 NOS AND 5 A - 14 NOS TEMP INDICATORS - 2 NOS INDICATORS - 7 NOS START SWICH - 2 NOS STOP SWICH - 2 NOS ROTARY SWITCH - 3 NOS M PHASOR CLAMP 25 MM GRIP 6 MM SCREW 25 MM / 1" SCREW DRY WALL 1 1/2" TIE 250 INSULATION TAP R B G Y COPPER 5 KG ANCHOR BOLT 6 MM C PVC PIPE 1 " CPVC ELBOW 1 " CPVC TEE 1 "CPVC 1" 45 UNION CPVC 1" VALVE CPVC 1" MTA CPVC 1" FTA CPVC 1" TUFFLON TAPE CPVC COUPLING 1" PVC FTA 1" VALVE PVC 1" PIPE PVC 1" ELBOW PVC 1" PVC TEE 1" CPVC SOLVENT PVC SOLVENT FOOT VALVE 1" WIRE 2.5 MM WIRE 1.5 MM WIRE 4 KG THERMO COUPLE LABOUR PANEL BOARD --3 PHASE CONTACT - 4 NOS TIMER RELY 25 A CAPASITOR - 3.0 KVAR & 2.7 KVAR NC & NO - 4 POLE - 1 NO AND 2 POLE - 2 NOS 32 A ISOLATOR - 4 POLE MCB CONNECTORS - 10 A - 14 NOS AND 5 A - 14 NOS TEMP INDICATORS - 2 NOS INDICATORS - 7 NOS START SWICH - 2 NOS STOP SWICH - 2 NOS ROTARY SWITCH - 3 NOS
OD385148/2025-2026:SS Bed of 20mm diameter arranged suitably in primary chamber with installation , fixing and transportation charges etc complete
OD385159/2025-2026:Primary Chamber with refractory work Primary Chamber of minimum outside dimension 2.9 m x 1.9 m x 1.5 m and inner dimension 2.7m x 1.1 m x 0.9 m made with MS sheet of minimum plate thickness of 5 mm properly supported and connected using MS channels, MS angles and MS flat with inside refractory brick lining insulation, sidearch, endarch , railbrick 70% STD fixed using fireclay , acooset, castable normal, castable super and insulate 7 withstanding 1400 degree heat, painting with hammerton silverash paint with primer and thinner including all labour, conveyance and installation charges etc complete.
OD385161/2025-2026:Rail and trolley: Rail & Trolley of minimum outside dimension 3.35 m x 0.91 m x 0.61 m:- In two parts to lay body inside the primary chamber using MS angles, MS flat, MS pipe ,MS rods plain and MS square rod polished with proper wheel and wheel bearing mechanism, gearbox (size 850x250x90mm with gear box shaft right hand 2nos and drive pinion shaft) for movement painting with hammerton silverash paint with primer and thinner with all labour, transportation and installation charges etc complete
OD385183/2025-2026:Door of primary chamber:- Front opening, vertical sliding, counter weight balanced with view port using MS sheet supported and connected using MS flat, MS pipe and MS channel of minimum thickness of 6 mm. The door to be operated using steering wheel with bearings and MS Sprocket roller chain of suitable size , door to have ceramic wool, SS mesh 304 grade with finished thickness 6-7cm necessary fittings for proper closure painting with hammertone silverash paint inclusive of primer and thinner including all labour, installation, transportation charges etc complete.
Wiring
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
1.55.2:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
MCCB, MCB and DBs
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
OD265700/2025-2026:2.4.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
OD265715/2025-2026:2.5.1 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (butwithout MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
OD266054/2025-2026:Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four pole
OD266163/2025-2026:Supplying and fixing 40 amps to 63 amps rating, 240/415 V, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD270401/2025-2026:Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD270427/2025-2026:Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD270410/2025-2026:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD266305/2025-2026:Supplying and fixing DP sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc.
OD266350/2025-2026:Supply, installation, testing and commissioning of thermoplastic enclosure (IP65) of size 146x238x111mm on surface/ recess for fixing MCB/RCCB/Isolator complete with connections, testing and commissioning etc. as required. 1row 6 module
OD266365/2025-2026:Supply, installation, testing and commissioning of thermoplastic enclosure (IP65) of size 295x333x129mm on surface/ recess for fixing MCB/RCCB/Isolator complete with connections, testing and commissioning etc. as required. 1row 12 module
Earthing
OD266503/2025-2026:Earthing with G.I. earth pipe 3 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
OD266560/2025-2026:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 3.15 mm copper conductor ( 10 SWG)
OD266609/2025-2026:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required, 25x3mm Cu strip
OD266680/2025-2026:Supply and fixing following size earth bench, fixing on surface of wall/parapet using iron screws, bench having holes for connecting earth strip/wires, making good the damages, colour washing etc as required. 25x3x400 mm Cu earth bench.
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
LT Cable Supply, Laying and Termination
7.3.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD267422/2025-2026:Supply of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes as required. 4 core 25 sqmm
OD267423/2025-2026:Supply of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes as required. 4 core 16 sqmm
OD267424/2025-2026:Supply of one number XLPE insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes as required. 4 core 10 sqmm
OD267425/2025-2026:Supply of one number XLPE insulated and PVC sheathed armored copper power cable of 1.1KV grade of the following sizes as required. 3 core 6 sqmm
OD267430/2025-2026:Supply of one number XLPE insulated and PVC sheathed armored copper power cable of 1.1KV grade of the following sizes as required. 3 core 1.5 sqmm
9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD267431/2025-2026:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3 x 6 sq. mm Cu
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD267433/2025-2026:Supply and fixing of polycarbonate cable junction box (93x93x62mm) IP66/67 in surface/ recess including cutting the wall and making the same in case of recessed installation. The junction box shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive, shockproof with 5 pole terminals suitable to terminate up to 2.5 sqmm cable
OD267435/2025-2026:Supply and fixing thermoplastic polyamide cable gland (IP68) with appropriate size locknut suitable for connecting up to 2.5 sqmm cable including all accessories as required
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
Panel Boards
OD267443/2025-2026:Fabrication, supply, installation, testing and commissioning of cubicle construction made out of 1.6mm thick CRCA sheet, totally enclosed, free standing, wall/floor mounting, dust and vermin proof, powder coated, outdoor with canopy, IP 54 rated, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system, including internal wiring with suitable size wires, 3mm thick gland plate, hinged type door with neoprene gasket etc. including fixing it and making good the damages colour washing etc. as required. Comprising the following: (Specification as per the submitted scheme) Metering Panel: Incomer: 63A Cutout fuse-3 Nos 63A FP 25KA MCCB with shunt trip - 1 No. ELR with CBCT- 1 Set Provision for fixing Three phase energy meter. Provision for fixing 4 nos of -/5A CL-.5 resin cast CT Seiling provision for KSEB (Rate of Energy meters are not included in the estimate)
OD267444/2025-2026:Supply, installation, testing and commissioning of 63A 4pole on load change over switch in 1.6mm thick CRCA sheet enclosure, wall mounting, dust and vermin proof, powder coated, including all connections, etc. as require
OD267447/2025-2026:Supply and installation of 3 phase 4 wire class 0.5 LT TOD meter , tested at Electrical inspectorate/EB approved laboratory and commissioning of LT TOD meter with tested CT units in the metering provision compartments and giving necessary connections etc. as required. (Note: Meter and CT unit testing charges not included)
Light Fixtures and Fans
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
90.4.3:Conveyance installation testing and commissioning ceiling fan of all sizes using standard accessories excluding resistance type regulator wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or extending the original wiring etc. as required.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.9:Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
OD267714/2025-2026:Supply of 18±3W Suspended LED light fixture (IP 20) have CRCA powder coated housing, black finish, 4000K-5700K colour temperature with minimum 100 lumen/Watt, working on 240V AC, suitable for indoor applications etc as required. Make: Wipro-Halo Plus or equivalent
OD267721/2025-2026:Supply of 22±2W surface mounted LED tube light fixture, 6500K colour temperature, minimum 100 lumen/Watt, working on 240V AC etc as required.
OD267735/2025-2026:Supply of 6±2W LED surface mounted square down light fixture (IP20), housing made of fibre reinforced plastic, 6500K colour temperature with minimum 100 lumen/Watt suitable for indoor applications with duly wired up for use on 230 V AC. Make - Philips Sleek or equivalent
OD267740/2025-2026:Supply of 10±2W Surface mounted LED mirror light fixture, 4000K colour temperature, minimum 100 lumen/Watt, working on 240V AC etc as required. Make: Wipro -Trim Neo or equivalent.
OD267750/2025-2026:Supply of 7±2W Surface mounted LED bulkhead light fixture (IP 65), 5700K-6500K colour temperature with minimum 100 lumen/Watt, working on 240V AC, suitable for outdoor applications etc as required. Make: Philips- VistaGlow or equivalent.
OD267787/2025-2026:Supply installation testing and commissioning of 7±2W spike light fixture (IP 65) have aluminium housing, 3000K-4000K colour temperature with minimum 80 lumen/Watt, working on 240V AC, suitable for outdoor applications, including all connections etc as required. Make: Philips Garden Spike or equivalent
OD267811/2025-2026:Supply Conveyance, installation, testing and commissioning of 30±2W LED Flood light output greater than 85lumen/W 4000K-6000K with IP 65 and IK 07 protection, duly wired up for use on 230 V AC supply. Make: Philips Essential Smartbright Flood light BVP102 or equivalent.
OD267820/2025-2026:Supply, installation, testing and commissioning of 35±2W Suspended light fixture (IP65) have pressure die-cast housing, impact resistance IK08, internal surge protection 4kV, inbuilt encapsulated potted driver, efficiency 120 lm/W, 5700K colour temperature, working on 240V AC, suitable for use in harsh Industrial environment, including all connections etc as required. Make: Philips-Dura LED Pro or equivalent.
OD267842/2025-2026:Supply of 40±5W Surface/ wall mounted LED batten( IP65) having Co-Extrusion Polycarbonate housing, 4000K-6500K colour temperature, with minimum 130 lumen/Watt, working on 170-270V AC, etc as required. Make: Philips- SmartBright Waterproof or equivalent
OD267859/2025-2026:Supply of 1200mm sweep single star rated ceiling fan complete with 300mm down rod ,canopies, shackles and blades, excluding resistance type regulator working on 230V/240Vsingle phase AC. Make - Crompton or equivalent
OD267864/2025-2026:Supply of following Exhaust fan in plastic frame working on 230 V AC etc. as required. 250mm light duty exhaust fan. Make - Crompton or equivalent
OD267888/2025-2026:Supply of 380mm heavy duty exhaust fan in metal frame working on 230V/240V single phase AC. Make- Crompton or equivalent
OD267940/2025-2026:Supply and fixing of suitable size S type hook including all connections etc. as required.
OD267942/2025-2026:Supplying and providing steel chain (16 SWG) for suspending light fixtures including all connection etc. as required
DG and Exhaust Works
OD268057/2025-2026:Supply of 20kVA three phase 415V, 0.8pf 50Hz Diesel engine driven generator set with Standard control panel, acoustic enclosure etc. Diesel generating set comprising of diesel engine, alternator fuel tank, control panel etc complete. Diesel engine shall be suitable for continuous operation of generator set inclusive of fly wheel, flexible coupling, air cleaner, corrosion resistor, fan with guard, fuel pump, fuel filter, electrical starting system with starter, 12V battery and battery charger. (Civil foundation not included) Rate arrived for DG sets having emission standard as per CPCB IV.(Including 1 year AMC)
OD268067/2025-2026:Conveyance, loading, unloading, installation, testing and commissioning of 20kVA three phase 415V DG Set including all connections etc. as required
OD268084/2025-2026:Supply, erection, commissioning of 2" dia additional length of exhaust pipes with necessary bends, clamps etc from residential silencer as required excluding the support for the pipe.
OD268098/2025-2026:Supplying and providing thermal insulation with aluminium cladding to 2" dia exhaust pipe as required
UPS and Battery System
OD268182/2025-2026:Supply, installation, testing and commissioning of 2kVA, single phase input, single phase output UPS system along with necessary 12V SMF batteries for 30 minutes back up and powder coated rack including all accessories, cabling etc. as required. Make: Numeric, Socomec or equivalent
Miscellaneous Works
OD268238/2025-2026:Supply and fabrication of necessary MS items to the building/structure using necessary supports such as angle iron, MS clamp etc. The quoted rate shall include two coats of primer and two coats of enamel paint etc as required.
OD268242/2025-2026:Supply and laying 2.00 mm thick, 2x1 m length 3.3 kV, Synthetic elastomeric fire retardant insulating sheet as required.
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD268252/2025-2026:Supply and fixing of 6kg capacity ABC fire extinguisher as required
OD268263/2025-2026:Supply and fixing framed shock treatment chart as required
OD268279/2025-2026:Supply of first aid box as required
Lighting & Miscellaneous
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD385350/2025-2026:Supply of one number XLPE insulated and PVC sheathed armored aluminium power cable of 1.1KV grade of the following sizes as required. 2 core 10 sqmm
OD385357/2025-2026:Supply of one number XLPE insulated and PVC sheathed armored copper power cable of 1.1KV grade of the following sizes as required. 3 core 2.5 sqmm
OD385361/2025-2026:Supply of one number XLPE insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes as required.3 core 1.5 sqmm
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
OD385368/2025-2026:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3 X 2.5 sq. mm Cu
OD385377/2025-2026:Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 3 X 1.5 sq. mm Cu
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
OD385404/2025-2026:Supply and fixing of polycarbonate cable junction box (93x93x62mm) IP66/67 in surface/ recess including cutting the wall and making the same in case of recessed installation. The junction box shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive, shockproof with 5 pole terminals suitable to terminate up to 2.5 sqmm cable
OD385408/2025-2026:Supply and fixing thermoplastic polyamide cable gland (IP68) with appropriate size locknut suitable for connecting up to 2.5 sqmm cable including all accessories as required.
OD385413/2025-2026:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
OD385720/2025-2026:Supply, installation, testing and commissioning of 45W LED street light fixture (IP 66), 5700K colour temperature, in-built electronic driver, duly wired up for use on 240 V AC supply, suitable for outdoor applications including all connections etc. as required. Make: Wipro- Skyline or equivalent
OD385731/2025-2026:Supply, installation, testing and commissioning of 6W LED gate light fixture (IP 54), having aluminium die-cast housing, 3000K colour temperature, matt grey finish, duly wired up for use on 240 V AC supply, suitable for outdoor applications including all connections etc. as required. Make: Jaquar- Irena or equivalent
90.15.3.5:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
OD385742/2025-2026:Supply and fixing of loop in loop out connector in the existing street light poles as required.
OD385748/2025-2026:Supply and fixing of 10cm DIN rail for fixing SP MCB in the existing street light poles asrequired
OD385752/2025-2026:Supply and fixing of 25cmX12cm hylam sheet in the existing street light poles as required
OD385756/2025-2026:Fabrication, supply, installation, testing and commissioning of outdoor wall/floor mounting type Feeder pillar made out of modular polycarbonate thermoplastic/GRP enclosures. The enclosure shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive in accordance with IEC 60439-2. The Degree of Ingress Protection IP 65/66 shall be in accordance with IEC 60529. The gasket material shall be polyurethane; while the gasket shall be internally embedded. The board shall be duly wired as per latest electrical standards including all switch gears as per specifications with canopy (Specification as per the submitted schematic drawing, any changes as per the recommendations from KSEBL/ Electrical inspectorate will be charged extra) Incomer: 25A DP MCB 10kA- 1 no. 25A 30mA DP RCCB- 1 no. Timer- 1 nos, 25A DP contactor -1 nos, Outgoings: 6A to 16A SP MCB 10kA- 5 nos, and all necessary accessories as required.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
KoorachundGPGCSBD.pdf
Tender Documents • 1.56 MB
Koorachunddwg.pdf
Additional Documents • 8.39 MB
PaymentDeclaration.pdf
Other Document • 0.24 MB
BOQ_1380962.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .