Providing electric connection to newly purchased XRD machine at Physics department
2023_NITC_757910_1
Engg/EMU/AE/197/XRD-Physics
Open Tender
Electrical Works
Item Rate
14 days
Calicut
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
Director
₹6,100
Yes
25 Jul 2023
15 Jun 2023
5 Jul 2023
15 Jun 2023
3 Jul 2023
15 Jun 2023
Amount
Supplying and fixing of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing 3 numbers 2.5 sq mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in existing surface / recessed PVC conduit as required.
Supplying and drawing 3 numbers 6 sq mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in existing surface / recessed PVC conduit as required.
Wiring for circuit/ submain with 2 X 10 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable with surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain with 2 X 10 sq. mm FRLS PVC insulated copper conductor, single core cable with in existing surface / recessed PVC conduit as required.
Wiring for circuit/ submain with 2 X 16 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable with surface/ recessed medium class PVC conduit as required.
Wiring for circuit/ submain with 4 X 16 sq. mm + 2 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable with surface/ recessed medium class PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 6 - 32 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 16 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing three phase 4 way ( 8+12 ),Vertical type, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 3 phase 4 way, double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB)
Supplying and fixing 100A, 16kA, 4 pole (Three pole and Neutral), 415 V, Moulded casing circuit breaker (MCCB) with Thermal magnetic protection in the existing MCCB enclosure , complete with connections, testing and commissioning etc, as required.
Supplying and fixing 40 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB/ enclosure, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB/ enclosure, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing metal enclosure, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 2 pole metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required.
Supplying and fixing 4 pole metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required.
Supply of 1.1 kV grade 3.5C x 50 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable as required.
Laying and fixing of one number 1.1 kV grade Aluminium conductor XLPE insulated PVC sheathed armoured power cable of 3.5C x 50 sq.mm size, clamping on wall using suitable metal clamps spacing not exeed 50 cm etc. as required.
Supply and making end termination with brass compression gland and aluminium legs for 3.5C x 50 sq.mm (32 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.
Supply and laying of one number 8 SWG good quality bare copper conductor for loop earthing along with existing XLPE insulated PVC sheathed armoured power cable as required.
Providing and fixing 125 A capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply and providing plate earthing (As per IS 3043 : 1966) with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 25 mm dia and 2.7 meter long with funnel etc. (but without charcoal / coke and salt) as required.
Supplying and laying 25 mm x 5 mm copper strip, from the bottom of the earth plate to the test joint, including connection / terminating with nut, bolt, spring washer etc, as required.(Jointing shall be done with 3 sets of GI nut, bolt & spring washer)
Supplying and laying 25 mm x 3 mm copper strip at 0.50 meter below ground/ clamping on wall as strip earth electrode , including connection / terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 meter below ground / clamping on wall as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and providing "Excel" Earthing compound including mixing with excavated fine soil and water to make it as slurry and filling around the earth plate etc. as required.
Charges for removing the existing wiring with switchboard and fiiting's, making good the damages of the wall and conveyance of the materials to the godown without any damage etc, as required.
DIAMOND ENGINEERING WORKS
Sivaprathapan KB
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .