| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | ₹1.2 Cr | L1 | Accepted-AOC LOWEST REASONABLE BID |
| 2 | L2₹1.3 Cr+₹7.2 L (5.94%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.3 Cr+₹7.2 L (5.94%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Eligible bidder being two class below the eligible class. |
| Sl No | Description | Qty | Unit | SHRI RAMSONS PROJECTS CORPORATION L2 | Shri Electrical Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Installing testing and commissioning of ISEER certified and minimum 3 Star rated water cooled chiller unit (2W +1S) complete 30 TR or above nearest actual capacity VFD controlled alongwith necessary drive arrangements and lubrication system as per manufacturers design required for smooth and trouble free operation of the chiller package with suitable No of scroll/screw compressors with single/multiple circuit (Hermetic Inverters scroll compressors) having automatic stepless capacity control, water cooled S/T type condencer, S/T horizontal flooded type evaporator with M S Shell and seamless copper tubes with elastomeric insulation, integral refrigerant piping and wiring, valves, fittings, expansion valves and accessoried to interconnect compressor, condenser, chiller and expansion valves. Microprocessor based control panel comprising o f controls including sensors and equipped with keyboard, LCD touch screen, access input system, protection and monitoring devices to perform control functions, vibrations isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly CFC free refrigerant R-410A/407C/134A. All complete as specified and directed by EIC.
Note :-
(a) Required temperatue inside shed = 22°C±3°C when outside shed ambient temperature = 50°C
(b) Required Humidity inside shed = 55%±10%
The chiller shall conform to the following requirements/specifications:- | 3 | Each | 14,21,421 ₹42,64,263 Lowest | 19,00,000 ₹57,00,000 |
| 1.01 | (i) Chilled water inlet/outlet temperature: 12°/7°C | - | - | - | - |
| 1.02 | (ii) Evaporator foliator: factor:0.00010M2K/KW | - | - | - | - |
| 1.03 | (iii) Evaporator side pressure drop :3.5 m of H2O (Maximum) | - | - | - | - |
| 1.04 | (iv) Condenser water inlet/outlet temperature: 32°/36°C | - | - | - | - |
| 1.05 | (v) Condenser fouling factor: 000025 M2/KW | - | - | - | - |
| 1.06 | (vi) Condensor side pressure drop :3.5 m o f H2O (Maximum) | - | - | - | - |
| 1.07 | (vii) Minimum COP @ 100% load : 5.6 a t ISEER conditions. | - | - | - | - |
| 1.08 | (viii) Minimum NPLV : 7.511 KW/KW at ISEER conditions. | - | - | - | - |
| 1.09 | (ix) Refrigerant (Ozone friendly type) : R410A/R407C/R134A | - | - | - | - |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
16 Jun 2026, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULATN LINE ARMY AREA JODHPUR-342010
SPL REPAIR TO CENTRAL AC PLANT AGAINST BER AT CERTAIN UNIT UNDER GE BANAR
2026_MES_766098_1
CWE (A) JODH/BNR- OF 2026-27(82627/16/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE BANAR
₹2.1 L
Yes
7 Sept 2026
18 May 2026
18 Jun 2026
18 May 2026
16 Jun 2026
9 Jun 2026
18 May 2026 - 8 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Installing, testing and commissioning of WATER COOLED CHILLER complete 30 TR OR above nearest actual capacity with twin screw /Scroll compressor with twin circuit, motor(s) starter(s), WATER cooled condenser, insulated chiller, flow switch at chiller, vibration insolators, integral refrigerant piping and wiring, accessories as required and called for automatic and safety controls mounted in central console on a steel frame complete as per specifications. Motor shall be suitable for 415+(-) 10%, 50 cycles, 3 phase AC supply. Refrigerant used shall be R- 407C / R-134a.Chiller should be provided with micro- procesor based control panel for safe and efficient operatoin of chillers. Same should be capable for communicating over Bacnet/ Modbus protocol. Chiller compressor should have displacement power factor of 95% at all load conditions. Deration due to higher ambient shall also be considered in actual capacity calculation. Chiller should not trip at air inlet temperature of 52.0 Deg. C to condenser. complete all as specified and directed b y Engr-in-charges. | 3 | Each | 31,00,000 | ₹93,00,000 |
| - | Chiller | - | - | 31,00,000 | - |
| - | Chiller Water IN 10 Deg C | - | - | 31,00,000 | - |
| - | Chilled water OUT 5 Deg C | - | - | 31,00,000 | - |
| - | Fouling Factor 0.00025 M2/KW | - | - | 31,00,000 | - |
| - | Condenser | - | - | 31,00,000 | - |
| - | Condenser Air IN 32 Deg C | - | - | 31,00,000 | - |
| - | Condenser Air IN 36 Deg C | - | - | 31,00,000 | - |
| - | Fouling Factor 0.0002 FPS | - | - | 31,00,000 | - |
| - | Screw Chiller Capacity Range should be - 100% to 15 % or better at constant design temperature. | - | - | 31,00,000 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
BOQ_857988.xls
BOQ • 1.16 MB
TENDER16.pdf
Tender Documents • 1.26 MB
corrigendumno02-82627-16-E8.pdf
PDF • 0.10 MB
corrigendumno01-82627-16-E8.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .