Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹42.9 L+₹1.3 L (3.24%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-AOC Not lowest |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
12 Dec 2020, 6:00 pmClosed
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR TO INTERNAL ELECTRIFICATION FANS GEYSERS AND ASSOCIATED WORKS AT AF STN JODHPUR AND KAILANA
2020_MES_395556_1
8429/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹82,000
Yes
26 Dec 2020
16 Nov 2020
14 Dec 2020
16 Nov 2020
12 Dec 2020
30 Nov 2020
Amount
Taking down carefully old unserviceable copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc Complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable MCB DB with MCBs any type and any capacity all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable Sub main wiring any type any size all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators One light/fan point controlled by one way switch complete all as specified and directed by Engineer in Charge.
All as per item Ser No 4.00 above but for one 3 pin 5 or 6 Amps socket outlet on independent board with other switches.
All as per item No 4.00 above but for one 3 pin 5 or 6 Amps socket outlet on same board.
All as per item Ser No 4.00 above but one bell buzzer controlled by one push button on indipendent board.
All as per item Ser No 4 above but with 2.5 Sqmm cable for one 6 pin 5/15 Amps socket outlet with 1.5 Sqmm PVC insulated copper conductor unsheathed 1100 volt grade FRLS cable for continuous earth wire complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs switch piano 5 amps flush type single pole one way complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs switch piano 16 amps flush type single pole one way complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs socket outlet flush type 5 pin 6 amps complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Switch Bell push flush type, 5 Amps 240 volts complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Call bell ding dong musical type , AC, 230 Volts, Single pole complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs Steped type elecrtonic fan regulator flash type on the existing phenolic laminated sheet etc suitable for 240 volt complete all as specified and directed by the Engineer-in-Charge.
Supplying and fixing/drawing submain wiring with two single core 6 Sqmm FRLS PVC insulated copper cable 1100 vots grade multistrand, unseathed conductor drawn into PVC casing and caping and all necessary fittings including 4 sqmm multistrand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dully complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 32 amp complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 40 to 63 amp complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 6 to 32 amp complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 to 63 amp complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing distribution board TPN, 440 volts, 8 ways, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs LED tube light fitting 20Watt complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Writing MES number (having 16-20 nos letters or figures as one job) (Block, Roman, Italic or Indian) with white acrylic paint on E/M equipments i.e. Transformers, VCB, RMU, Voltage Stablizer etc complete all as specified and directed by the Engineer-in-Charge.
Supply, fixing & testing of Spring charging mechanism assembly with motor, gear box self tripping coil, closing coil, tripping coil etc complete for indoor type 11KV RMU of Make ABB operated on 24volt DC with charging time less than 15 sec of approved rating, the installation and testing of assembly will be done by the representative of OEM including taking down & dismantling the old unserviceable equipment complete all as specified and directed by the Engineer-in-Charge.
Disconnecting HT and earth termination connections from 11KV RMU outdoor type controlled by indoor control panel taking down from the plinth and loading into the vehicle, transporting the same to manufacturer's service engineer/ authorised channel partner for the following checks including dismantling/ replacing the defective parts (cable inlet insulator) for smooth functioning and including testing of RMU for carrying out necessary repairs and back, reconnecting HT connections at site and charging on load, commissioning and testing at site all as directed by the Engineer in Charge :- (i) Cleaning, derusting, lubrication, greasing of mechanism (ii) Replacing of defective components cable inlet insulator (iii) Checking and rectifying the problem the critical setting of mechanism (iv) Checking the critical setting of closing coil & tripping coil (v) Checking of gas leakage (vi) Tightening of control wires connection. (vii) Insulation measurment of main circuit (viii) Contact resistance of main circuit (ix) Check oil leak absorber (x) Topping up of SF6 Gas. Note :- The above work of repair & replacement under this item shall be carried out by the concerned manufacturer OEM at thier workshop/site.
Material & labour for finding out the leakage of SF6 gas from RMU and top up the SF6 gas after rectifying & removal of defects of leakage complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs right angled 11KV boot for HT cable complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs GI pipe bracket, made out of 1.2 metres long, 40 mm dia light grade GI pipe, fabricated into shape and size as required, complete with 02 Nos. MS clamp of MS flat iron 40 x 6 mm with bolts, nuts and washer complete all fixed on poles/walls complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs FRP Junction box for street light central with linked door control with & including 6 Amp MCB SP with aluminium bus bar TPN for controlling the Street Lights complete with pole mounting type size 300x300x150mm complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in repairs Energy saving LED STREET light fitting of 60 Watt capacity with built in control box (IP66) suitable for out door application fixed on PCC Block with all connecting items clamps,nut bolts complete all as specified and directed by the Engineer-in-Charge.
Material & labour for GI pipe medium grade 80mm dia and 04 meter in length for street light pole including excavation & earthwork in any type of soil, returning and filling in, PCC (1:4:8) in foundation , PCC (1:3:6) in coping , with & including dismantling the old PCC pole by breaking the old PCC foundation and removal of all the debries outside MOD land complete all as specified and directed by the Engineer-in-Charge.
Material & labour for excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed by the Engineer-in-Charge.
Material & labour for returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by the Engineer-in-Charge.
Material & labour for removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Sand cusioning to cable with screened & washed sand & punning to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note:- only punned thickness to be measured and paid.
Laying only old retreived stone slab 40 to 50 mm thick Jodhpur stone patties/ slab cover in trenches for protection of cable 25 to 30 cm wide laid dry abutting each other with gap between adjacent slab not exceeding 10 mm complete all as specified and directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, LTcable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminim conductor of size 25 Sqmm 4core including dismantling & taking down the old unserviceable cable complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of PVC insulated copper cable of 2.5 Sqmm 2 core complete all as specified and directed by the Engineer-in-Charge.
Material & labour for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber,precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m, including dismantling & taking down the old unserviceable earthing and removal of debries complete all as specified and directed by the Engineer-in-Charge. Note:- Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply & fixing in replacement of automatic street light timer using nature switch for automatic switching of street light based on LUX level of natural light .The sensor (nature switch) along with suitable power contactor, MCB and support terminal should be enclosed in pole/wall mountable enclosure made of rust proof, electric shock proof ,termite proof and FF grade SMC junction box (sintex make) confirming to IP 54 suitable for three phase phase of 08 KW model -Swadeep -02EC08kW3P of make -Nature switch or equivalent in legrand/siemens.
Material & labour for disconnecting, dismantling , Taking down the heat exchanger of solar water heater from roof of the building and repair the heat exchanger of solar water heater with electric backup of capacity 1000/2000 ltrs per day including striping, flush out the complete system to remove any floating and settled dirt, cleaning of tank etc and make it functional to the entire satisfaction of Engineer in charge , and refixing & connecting the same after repair on the same place complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing replacement of Heating Element of 20KW suitable for elect. backup for solar water heater complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing replacement of Thermostat suitable for 1000/2000 ltrs solar water heater complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Air release valve suitable for 1000/2000 litres solar water heater complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Gate valve suitable for 1000/2000 litres solar water heater complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of Check valve suitable for 1000/2000 litres solar water heater complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement of triple pole and earth enclosure with a three pin and earth plug with socket complete with & including one triple pole MCB 63 Amp complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacemtent PUF insulation fixed on GI pipe of size 25mm dia as outlet of solar water heater ensure that heat generated by the water heater is retained for long time complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing replacement of 25mm bore ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe, minimum weight 455gm complete all as specified and directed by the Engineer-in-Charge.
Surface cleaning/site clearance not exceeding 15 cm in depth in Sub stations area, trenches, sub station rooms, two pole/ four pole structure surrounding, LT panel, fencing to make a over all presentable condition complete all as specified and directed by the Engineer-in-Charge.
Supply, installation, testing and calibration of relay 110V of Microprocessor based three phase relay system to overcurrent, one earth fault protection type for 33 KV breaker, setting range suitable for over current and earth fault with necessary wiring/fitting including dismantling of old IDMT or unserviceable relays.The setting of the relay should be in accordance with the incomer and setting should be maintained such that fault does not carry beyond the affected feeder in case of Overload, 3 phase fault, earth fault etc complete all as specified and directed by the Engineer-in-Charge. Note :- (i) The calibration of relay of Microprocessor based three phase relay system required to carried out at CPH. Make C&S model no. CSENex-I 150 in equivalent Schenider, Siemens. (ii) The calibration of relay of Microprocessor based three phase relay system to be carried out by OEM representative.
Supply, installation, testing and calibration of relay 110V of Microprocessor based three phase relay system to overcurrent, one earth fault protection type for 11 KV breaker, setting range suitable for over current and earth fault with necessary wiring/fitting including dismantling of old IDMT or unserviceable relays.The setting of the relay should be in accordance with the incomer and setting should be maintained such that fault does not carry beyond the affected feeder in case of Overload,3 phase fault, earth fault etc complete all as specified and directed by the Engineer-in-Charge. Note :- The calibration of relay of Microprocessor based three phase relay system required to carried out at CPH. Make C&S model no. CSENex-I 150 in equivalent Schenider, Siemens. (ii) The calibration of relay of Microprocessor based three phase relay system to be carried out by OEM representative.
Trimming/cutting the tree branches/ bushes around the HT over head line and making safe clearance up to 4.00 metre distance from line wire/panel complete all as specified and directed by the Engineer-in-Charge.
Attending day to day street / security light (of any type and make, installed at various locations of domestic area & 33SU site 1A & 1B at AF station jodhpur) complaints received through telephone or in person, identification and rectification of defects by bringing down the fittings on ground or in position including replacement of drivers, Surge Protection Device (SPD), GI Socket, replacement of old unserviceable light fittings, cleaning of glass/acrylic cover for clear reflection of light, jumper fixing, tightening of loose connections, GI bracket tightening, checking the connection of FRP junction box, light alignment, MCB, MCCB, Contactor etc replacement of straight through joint and properly insulating the connections complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Replacement of unserviceable items shall be measured and paid for seperately as 'Supply only' under respective items of schedule 'A'/BoQ . (ii) contractor shall provide/depute sufficient number of electricians and helpers (as directed by Engineer-in-charge) to attend the complaints and rectified the same within 04 hours of receipt of complaints. (iii) contractor manpower shall attend daily to recieve complaints at complaint cell at 9.00 AM from JE E/M and report after completion of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Vehicle, ladder, tools, LT tapes and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. (v) Any complaint/job given on a particular day shall be repaired/rectified within four hours on the same day. The rate of recovery against non attending/completing job on same day shall be Rs. 75/- per complaint per day. (vi) Old retrieved material shall be deposited in AGE E/M yard and shall be given to contractor after completion of contract.
Supply only 6 Sqmm 2 core, LT 1100 volts grade weather proof, PVC insulated and PVC sheathed, multi stranded aluminium conductor cable, flat type, 1100 volt in service connections etc complete all as specified & directed by the Engineer-in-Charge.
Supply only electric driver for 50 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 72 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only electric driver for 90 Watt LED type light fitting complete all as specified and directed by the Engineer-in-Charge.
Supply only surge arrestor of 5KV/10KV for LED type fittings complete all as specified and directed by the Engineer-in-Charge.
Supply only LED street light 72 Watt with IP 65, 230 Volt with all connected acessories required complete all as specified and directed by the Engineer-in-Charge.
Supply only LED street light 90 Watt with IP 65, 230 Volt with all connected acessories required complete all as specified and directed by the Engineer-in-Charge.
Supply only LED flood light 150W with IP66 protection with all necessary accessories required for fitting complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully ceiling/exhaust fan of any sweep with frame cable sealing end and dismantling of blades brackets etc complete Opening dismantling of ceiling fans 1200mm sweep cutting and taking out old burnt/damaged winding/material by any means, & Material and Labour for re-winding the same with supper enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan recommended quality grease/oil, re-assembling including provision of PVC copper twisted conductor three core of size 1.5 Sqmm of required length and testing complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully ceiling/exhaust fan of any sweep with frame cable sealing end and dismantling of baldes brackets etc complete Opening/dismantling of exhaust fan 450mm sweep by any means and taking out old burnt/damaged winding/material by any means, & Material and Labour for rewinding the same with super enamelled copper wire of existing/same SWG including all insulating material all as required as per standard practice, varnishing the same and drying, cleaning fan bearing/bushing and greasing/oiling the same with recommended quality grease/oil, reassembling and testing including provision of PVC copper twisted conductor three core of size 1.5 Sqmm of required length complete all as specified and directed by the Engineer-in-Charge.
All as per item No 65 herein above but exhaust fan 380mm sweep all as specified & directed. Note for Item No-64 to 65 :- Spare parts shall be measured and paid seperately under respective item schedule.
Supply only bearing of ceiling/exhaust fan etc complete all as specified and directed by the Engineer-in-Charge.
Supply only capacitor 415 Volts, 50 Hz 2.5 MFD and connect the same in circuit and testing complete all as specified and directed by Engineer-in-Charge
Supply only capacitor 415 Volts, 50 Hz 4 MFD and connect the same in circuit and testing complete all as specified and directed by Engineer-in-Charge
Supply only bush suitable for ceiling/ exhaust fan any sweep and oiling complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch air break gang operated triple pole mechanically operated horizontal/vertical type mounted on insulator & steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps horizontal type suitable for 11000 V grade including dismantling & taking down old, deteriorated, switch air break and complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing expulsion fuse single pole (drop out fuse) mounted on insulator & steel frame 100 Amps for 11000 V grade, including dismantling & taking down old, deteriorated, expulsion fuse assy and complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing switch air break gang operated triple pole mechanically operated horizontal type mounted on insulator & steel frame, with operating mechanism worked from ground level for current rating upto 400 Amps horizontal type suitable for 33000 Volt grade dismantling & taking down old, deteriorated, switch air break and scomplete all as specified and directed by the Engineer-in-Charge.
Material & labour for disconnecting, taking down the geyser of any capacity including striping, cutting the existing copper inner tank after welding, brazing and tightening the hold fast ,nuts, bolts, washer etc & make it functional to the entire satisfaction of the Engineer in Charge and refixing the same after repair on the same place and including making good to disturbed existing surface with plastering complete all as specified and directed by the Engineer-in-Charge. Note :- Any major spare parts shall be measured and paid seperately as supply only here in after.
Supply only heating element of Geysers of 1.5 KW rating required at site including rubber washers complete all as specified and directed by the Engineer-in-Charge.
Supply only heating element of Geysers of 2 KW ordinary size rating required at site including rubber washers complete all as specified and directed by the Engineer-in-Charge.
Supply only thermostat for the Geyser of 25 Litres capacity ISI marked complete all as specified and directed by the Engineer-in-Charge.
Supply only thermostat for the Geyser of 50 Litres capacity ISI marked complete all as specified and directed by the Engineer-in-Charge.
Supply only base assembly complete with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut and bolts, washer for Geyser of capacity 25 Litre complete all as specified and directed by the Engineer-in-Charge.
Supply only base assembly complete with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut and bolts, washer for Geyser of capacity 50 Litre complete all as specified and directed by the Engineer-in-Charge.
Supply only Gun Metal non return valve 15mm dia for geysers complete ISI marked complete all as specified and directed by the Engineer-in-Charge.
Supply only Gun Metal non return valve 20mm dia for geysers complete ISI marked complete all as specified and directed by the Engineer-in-Charge.
Supply only safety valve/high pressure release valve for Geyser of 25 Litres capacity ISI marked complete all as specified and directed by the Engineer-in-Charge.
Supply only safety valve/high pressure release valve for Geyser of 50 Litres capacity ISI marked complete all as specified and directed by the Engineer-in-Charge.
Supply only PVC heavy duty hot type connecting pieces nylon braided with brass adopters 600 mm long suitable for Geyser of 25/50 Litre capacity complete all as specified and directed by the Engineer-in-Charge.
Supply only PVC heavy duty hot type connecting pieces nylon braided with brass adopters 450 mm long suitable for Geyser of 25/50 Litre capacity complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs for single pole and neutral metal clad enclosures with a two pin and earth plug and socket complete with one single MCB 20 amps ‘C’ curve type and electrical connection complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing in repairs industrial type socket plug top including 3 Core x 2.5 Sqmm copper multi stranded 1.50 m long including necessary connection complete all as specified and directed by the Engineer-in-Charge.
Supply only geyser inlet tank made out of heavy duty copper body of capacity for 25 Litres complete all as specified and directed by the Engineer-in-Charge.
Supply only geyser inlet tank made out of heavy duty copper body of capacity for 50 Litres complete all as specified and directed by the Engineer-in-Charge.
Supply only rubber ring for geyser 9 holes at site complete all as specified and directed by the Engineer-in-Charge.
Supply only rubber ring for geyser round type at site complete all as specified and directed by the Engineer-in-Charge.
Supply only geyser indicator lamp square type/round type complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs pan type humidifer having 6 kw capacity along with hygometer and control through humiditistate, humidifier divided into two chambers from inside one bank is heater is kept ON where the AHU is in operation to maintain the temp of water between 60-70 deg C and the other banks gets 'ON' upon signal from the humidistat for humidification and other necessary controls ,electricals panels etc including dismantling and taking down the old unserviceable humidifer complete all as specified and directed by the Engineer-in-Charge. Make:- Rapid cool/cool air system/Voltas/ Bluestar or equivalent as approved by GE.
Supply and fixing LT panel floor mounted , indoor ,cubicle,& compartmentalized , front access type ,medium voltage electric panel of dust and vermin proof ,fully tropicalised construction ,front openable doors and shutters with locking arrangement, made out of 14 SWG (2.0 mm thick) CRCA sheet steel ,factory fabricated ,powder coated ,suitable for operation on 450 Volts ,3 phase ,4 wire ,50 Hz,AC supply complete with all inter connections and consisting of all accessories like copper Bus Bar ,Indicating Lamps,Push buttons ,CTs ,Digital Ampere ,Voltage ,Frequency & KWH meter ,danger Plate,Lifting Hooks ,feeder Name Plates suitable for the following feeders (Note: the Panel shall be of suitable size to accomodate all the accessories mentioned below ,installed on Pedestal made out of angle iron of size 50mm x50mm 6mm &earth work, PCC foundation ,suitable cable glands for cable entry including dismantling and taking down the old unserviceable LT panel etc :- 1.0 Incomming Feeder : Suitable for 150 KW connected power 2.0 Outgoing Feeder : 2.1 For water cooled chillers -45 KW X 3 Nos, 2.2 For AHUs 7.5 KW X 3 Nos 2.3 For water pumps 5.5KW X 6 Nos. 2.4 Spare Feeders Total 03 Nos. One each for above equipments i.e each for 45 KW, 7.5 KW & 5.5 KW Feeders 2.5 Feeders for 9 Nos SP MCBs for Strip Heaters 2.6 Feeder for 12 Nos SP MCBs for Humidifier ,Fire Dampers & 3 Way valves & Spares.
Material & labour for sealed unit (compressor) 4 ton capacity including new drier filter of size 3/8, three phase, 415 volt of models as existing Tower ACs and replacing the same with new one sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation, pressure , testing, leaking, rectification including gas charging R-22 for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge including dismantling and taking down the old unserviceable compressor complete all as specified and directed by the Engineer-in-Charge.
Material & labour for new packaged type sealed unit (compressor) 12.5 ton capacity including new drier filter of size 5/8, model-SZ185S4RC , three phase, 415 volt including necessary modification of the foundation as required to suit the compressor, flushing the sysytem by nitrogen gas and pressure testing for leakage and rectified (by brazing) and after rectification vacumacation, pressure testing, and including gas charging R-407c for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge icluding dismantling and taking out unserviceable sealed unit (compressor) as existing complete all as specified and directed by the Engineer-in-Charge.
Material and labour for disconnecting, taking down Aqua RO 20-30 litres per hours from existing location , and servicing of the same RO machine including replacement of minor items like nut bolts washers, and refixed on the same place , make RO functional and testing the RO to the entire satisfaction of the Engineer in Charge. Note :- Replacement of defective spare/parts, these parts shall be measured & paid as supply only.
Supply Only Suitable SMPS Adaptor 24 volt DC ,2.5 Amp For convert AC to DC supply of the same make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply Only SLC Solenoid Valve 24V SV complete of the same make as per existing at site all as specified & directed by the Engineer-in-Charge.
Supply Only RO Booster Pump/Motor 100 GPD Suitable For all type of water purifier complete of the same make as per existing at site all as specified & directed by the Engineer-in-Charge.
Supply Only High grade White pipe 1/4" for RO water Purifier complete of the same make as per existing at site all as specified & directed by the Engineer-in-Charge.
Supply Only RO Elbow connector size 1/4" Both side Push suited for all complete of the same make as per existing at site all as specified & directed by the Engineer-in-Charge.
Supply Only filter membrane 1500 TDS of the same make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply only PP sediments filter 5 Micron of the same make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply only carbon block fillter pre filter of the same make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply only carbon block post filter of the same make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply only water level sensor for controlling RO machine of the same make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Material & Labour for Glow Sign Board of rectangle shape of size 15 feet x 2.5 feet, make out with MS frame , white fluorescent lighting and printed on flex "CENTRAL POWER HOUSE" with arrangement of angle iron frame of required size for holding the board and height of board from ground upto 15feet, including excavation & earthwork,return filling & removal PCC (1:4:8) in foundation , PCC (1:3:6) in coping, complete all as specified & directed by the Engineer-in-Charge.
Material & Labour for Glow Sign Board of rectangle shape of size 8 feet x 2.5 feet, make out with MS frame , white fluorescent lighting and printed on flex "MES POWER HOUSE" with arrangement of angle iron frame of required size for holding the board and height of board from ground upto 15feet,including excavation & earthwork, return filling & removal , PCC (1:4:8) in foundation , PCC (1:3:6) in coping, complete all as specified & directed by the Engineer-in-Charge.
Material & labour for precast cable route Indicator made out of cement concrete 1:2:4, type B1, using (20mm graded stone aggregate) having 15cm square shape at top and 30cm square shape at bottom and total height of 100cm fabricated as per direction of Engineer-in-Charge and grouted into PCC 1:2:4, type B-1, as per site requirement including embossed with "HT 11KV Cable and LT cable 1100V" at 50 meters in synthetic enamel Paint red coloured and necessary excavation and earth work in any type of soil as complete all as specified & directed by the Engineer-in-Charge.
Material & labour for cleaning of UG sump of capacity 80000 ltrs with steel wire brush, removing mud sludge and sand up to botton, washing with bleaching powder solution and applying one coat of white wash inside of UG sump including writing date of cleaning white colour over black cover base of sythetic enamel paint including minor repairs to tank where damaged complete all as specified & directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by the Engineer-in-Charge.
Material & labour for cement concrete 1:3:6 type C-0 mix (using 12.5 mm graded stone aggregate) as in padding finishing surface of concrete topping even and fair without using extra cement complete all as specified of average thickness 50 mm in slop 1:40 over roof complete all as specified and directed by the Engineer-in-Charge.
Material & labour for 10mm thick plastering in cement mortar 1:3 on concrete roof surfaces with water proofing compound @ 3% by weight of cement surface finished even and fair without using extra cement complete all as specified and directed by the Engineer-in-Charge. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI marked
Material & labour for 3mm thick APP white (Mineral gravel finished) polymer modified fibre glass reinforced membrane laid by torch application, sealed and surface shall be finished water proof, over and including a coat of bituminous primer @ 0.30 Ltr / Sqm complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Providing cement concrete 1:3:6 Type C0 (using 12.5 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by the Engineer-in-Charge.
Disconnecting existing tanks of any description exceeding 500 ltrs and not exceeding 1000 ltrs capacity and removing from site complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms) complete all as specified and directed by the Engineer-in-Charge.
Taking down existing steel rolling shutter of any size and type and Supply & Fixing new factory made steel rolling shutter with laths of thickness 1.00 mm without ball bearing as specified including top cover anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete, push pull or manual type complete confirming to the requirement of IS 6248-1979 complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully hood and steel rolling shutter of any size for replacement of unserviceable/defective parts and refixing in the same opening after cleaning of guide rails, laths, top cover by kerosene and proper greasing, oiling, replacement of rusted nut, bolts etc, removing of bend, alignment etc to make the system smooth functional & making good the disturbed surfaces all as specified & directed by Engineer-in-Charge. NOTE :- (i) The unserviceable parts shall be measured and paid for separately as "Supply only". (ii) Quoted rate shall be inclusive of providing missing nuts, bolts, greasing, oiling, denting, tension to spring etc.
Supply only MS sheet hood cover of 1.00 mm thick bent to shape match with existing brackets including stiffners of MS angles/flat complete all as specified and directed by the Engineer-in-Charge.
Supply only MS tubing 50 mm bore medium grade with necessary holes for shaft complete all as specified and directed by the Engineer-in-Charge.
Supply only MS tubing 40 mm bore medium grade with necessary holes for shaft complete all as specified and directed.
Supply only gear box of steel rolling shutter including handle rack & pinion system, bearing etc of rolling shutter size 5 Sqm and above but not exceeding 25 Sqm each complete all as specified & directed by Engineer-in-Charge.
Material & labour for taking down gear box for repairs including rack & pinion system bearing including welding teeth and grinding, greasing and refixing etc of rolling shutter size 5 Sqm and above but not exceeding 25 Sqm each to make serviceable including minor repair all as directed by Engineer-in-Charge.
Supply only helical wire rolling spring suitable for rolling shutters not exceeding 5 sqm each complete all as specified and directed by the Engineer-in-Charge.
Supply only helical wire rolling spring suitable for rolling shutters 5 Sqm and above but not exc. 15 sqm each complete all as specified and directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site complete all as specified and directed by the Engineer-in-Charge.
Material & labour for cutting holes in stone walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required, depth of embedded portion of hold fasts or lugs exc. one brick but not exc. two bricks from the face of the jamb in to the wall complete all as specified and directed by the Engineer-in-Charge.
Supply only guide channel of 75 mm for rolling shutters including hold fasts welded to channel complete all as specified and directed by the Engineer-in-Charge.
Material & labour for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by the Engineer-in-Charge.
Material & labour for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by the Engineer-in-Charge.
Supply only MS crank handle 250 mm long suitable for operating rollong shutter complete all as specified and directed by the Engineer-in-Charge.
Supply only ball bearing for rolling shutters complete all as specified and directed by the Engineer-in-Charge.
Material & labour for repair to locking device cleat of rolling shutter complete all as specified and directed by the Engineer-in-Charge.
Material & labour for replacement of 1.00mm thick MS laths of continuous single piece section without any welded joint, of steel rolling shutter, the lath section shall be rolled so as to have inter locking coils at both edges & deep corrugations at the center with average depth of not less than 12mm & each alternate lath section shall be fitted with malleable cast iron or mild steel clips securely riveted at either ends complete including painting with two coats of synthetic enamel paint over one coat of red oxide primer all as directed by Engineer-in-Charge.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off complete all as specified and directed by the Engineer-in-Charge.
Material & labour for rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed by the Engineer-in-Charge.
Material & labour for rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed by the Engineer-in-Charge.
Material & labour for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed by the Engineer-in-Charge.
Material & labour for PCC 1:2:4 type B1 as in fixing of hold fasts complete all as specified and directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins and providing and fixing new ones complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square not exceeding 0.5 SQM in EACH pane complete all as specified and directed by the Engineer-in-Charge.
Taking down chowkhat or frame n'exc 1.50 SQM Each (with out taking of shutters from the frame) complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded as complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing ventilator with top hung shutters including box hinges, steel peg stay and handle complete with glazing bars complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing stainless steel wire cloth ( 8% nickle cotent ) 0.46 mm nominal dia of wire and average width of aperture is 1.40 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed by the Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm complete all as specified and directed by the Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 15 mm Bore GI Steel Tubing medium grade with all fitting and fixed complete in wall and ceiling or laid in floors complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 20 mm Bore GI Steel Tubing medium grade with all fitting and fixed complete in wall and ceiling or laid in floors complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by the Engineer-in-Charge.
Material & labour for Preparing new plastered or unplastered surface and applying two coat of cement base paint all as specified and of shade dark gray or as approved by GE and directed by Engg-in-charge.
Supply & fixing in replacement 100 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, for chemical dosing to water pipeline including pipe required for fixing to existing pipe line complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing in replacement 1.1 litre primary and secondary diesel filter body assembly with diesel filters - 04 nos and all necessary items required for 160 KVA kirloskar DG set complete all as specified and directed by the Engineer-in-Charge.
Shri Electrical Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .