| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.0 LAccepted-AOC | ₹79.0 L Quoted ₹79.9 L | L1 | Accepted-AOC L1 AND ACCEPTABLE |
| 2 | L2₹81.0 L+₹1.1 L (1.37%)Rejected-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA GUJARAT 390002 | VADODARA | VADODARA | GUJARAT | 390002 | ₹81.0 L+₹1.1 L (1.37%) | L2 | Rejected-AOC NOT L1 |
| 3 | L3₹95.8 L+₹15.9 L (19.9%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | ₹95.8 L+₹15.9 L (19.9%) | L3 | Rejected-AOC NOT L1 |
Tender Value
₹84.5 L
EMD Value
₹1.5 L
Closing Date
26 Feb 2022, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
UPGRADATION OF MRS/ SUB STATION AT MIL STATION VADODARA
2021_MES_496745_1
87057
Open Tender
Civil Works
Item Rate
240 days
VADODARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE ARMY BARODA
₹1.5 L
Yes
6 May 2022
22 Dec 2021
28 Feb 2022
22 Dec 2021
26 Feb 2022
14 Feb 2022
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nainital or similar pattern roof covering. Complete all as specified and directed.
Dismantling framed trusses n exc 10 m span. Complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for. Complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil. Complete all as specified and directed .
Material & Labour for Cement concrete type D2 (1:4:8) using 40 mm graged stone aggregate in foundations, filling and mass concrete. Complete all as specified and directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for. Complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc. Complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sqm but n.exc 4.00 Sq m each. Complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5 sqm each. Complete all as specified and directed.
Supply & Fixing for pressed steel doors frame (thickness of MS sheet 1.25 mm) with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, stainless steel hinges, lock strike plate, etc., complete, as specified and as directed. Note :- Filling of hollow of frame with plain cement concrete anstainless steel hinges of 100 mm size will be measured and paid saperately under respective items. Complete all as specifed and as directed.
Material & Labour for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate in filling hollow portion of pressed steel/ hold fast of door frame. Complete all as specified and directed.
Material & Labour for 35 mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0 mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6 mm thick or external teak wood lipping fixed with nails, color and pattern as approved by EIC/ GE. Complete all as specifed and as directed.
Material & Labour for 100 mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/ PVC door frame with screw. Complete all as specifed and as directed.
Supply & Fixing 200 mm long Aluminium anodised barrel tower bolt of extruded section and fixed to Door Shutter. Complete all as specifed and as directed.
Supply & Fixing 125 mm size extruded aluminium alloy handles, febricated type anodised. Complete all as specifed and as directed.
Supply & Fixing 250 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12 mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters. Complete all as specifed and as directed.
Material & Labour for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in CM 1:6. Complete all as specifed and as directed.
Supply & Fixing of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.Complete all as specifed and as directed.
Supply & Fixing of Powder coated aluminium window/ventilator shutters, side hung/ sliding type aluminium sections including necessary joining cleats, sash bars, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws and grill etc as per manufactures instruction & trade pactee. Complete all as specifed and as directed.
Supply & Fixing 4.00 mm thick figured glass, pin head type and glazing with rubber beading or with glazing clips. Complete all as specifed and as directed.
Supply & Fixing stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples. Complete all as specifed and as directed.
Material & Labour for 16 to 18 mm thick machine cut green marbel stone as in floor, steps (in single piece), cooking platform etc laid over 15 mm thick cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including cement mortar 1:4. Complete all as specifed and as directed.
Steel rolling shutters 1 mm thick laths, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with chain wheel and hand chain. Complete all as specifed and as directed.
Supply & Fixing Safety lever locks mild steel with 4 levers for rolling shutters. Complete all as specifed and as directed.
Material & Labour for preparing new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer. Complete all as specifed and as directed.
Material & Labour for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specifed and as directed.
Material & Labour for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. Complete all as specifed and as directed.
Material & Labour for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also plays between floors and beams, etc. Complete all as specifed and as directed.
Material & Labour for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter. Complete all as specifed and as directed.
Material & Labour for Providing reinforced cement concrete Type A1 1:1 1/2:3 (using 20 mm graded aggregate) (nominal mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note. (reinforcement shall be measured and paid separately).
Material & Labour for Providing reinforced cement concrete type A0 1:1 1/2:3 (using 12.5 mm graded aggregate) (nominal mix) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and directed. Note. (reinforcement shall be measured and paid separately)
Taking down cement plaster on brick/ concrete surface including racking out joints hacking for key scrubbing down with water etc. Complete all as specifed and as directed.
Material & Labour for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distamper over a coat of (1 mm average thick plaster of paris) putty and one coat of primer. Complete all as specifed and as directed.
Material & Labour for rendering in two layer on fair faces of brick work or concrete sur-faces of wall 5 mm thick in CM 1:4 mixed with WPC @ 3% by weight of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately). Complete all as specifed and as directed.
Rendering 10 mm thick on new fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 for finished even and smooth (without using extra cement). Complete all as specifed and as directed.
Supply & Fixing for Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm. Complete all as specifed and as directed.
Supply only Internal water proofing compound. Complete all as specifed and as directed.
Material & Labour for preparing new plastered surface of walls including primer and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). Complete all as specifed and as directed.
Supply & Fixing in Steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe 410-W (Gde-E-250) quality- 'A'. Complete all as specified and as directed.
Supply & Fixing in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. Complete all as specified and as directed.
Refixing of Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde- E- 250) quality- A. Complete all as specified and as directed.
Supply & Fixing Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. Complete all as specified and as directed.
Material & Labour for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws. Complete all as specifed and as directed.
Supply & Fixing Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles. Complete all as specifed and as directed.
Re-fixing of pre-painted galvalume aluminum zinc coating GI based corrugated or tile pattern steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa, AZ 150 as in roof covering/ cladding to wall, fixed with self tapping screws. Complete all as specifed and as directed.
Supply & Fixing pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa, AZ 150 as in roof covering/ cladding ridge or hips, valley gutter to wall, fixed with self tapping screws. Complete all as specifed and as directed.
Material & Labour for sand filling under floors or in foundations including watering and consolidation. Complete all as specifed and as directed.
Moorum/ red bajri filling in floors or pavings, laid in layers n exc.15 cm thick, spread, levelled and rammed including watering. Complete all as specifed and as directed.
Material & Labour for Hardcore of broken stone of gauge n exc.63 mm, deposited, spread and leveled in layers n exc.15 cm thick, watered and rammed to a true surface. Complete all as specifed and as directed.
Material & Labour for cement concrete 150 mm thk, type D2 1:4:8 (40 mm graded stone aggregate) in sub base of flooring. Complete all as specifed and as directed.
Material & Labour for Granolithic concrete 1:1:2 floor topping 100 mm thick; laid over cement concrete subfloors etc. and finished to an even and fair surface. Complete all as specifed and as directed.
Material & Labour for 100mm thick PCC (1:2:4), type B-1 with using 20 mm graded stone aggregate as in flooring/ ramp etc. Complete all as specifed and as directed..
Material & Labour for Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green. Complete all as specifed and as directed.
Material & Labour for Framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-forming to Fe.290.Gde-E-165. Complete all as specified and directed
Material & Labourfor anodised aluminium snap grid frame work for false ceiling and hangers 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40mm long. Complete all as specifed and as directed.
Material & Labour for 6 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws. Complete all as specifed and as directed.
Material & Labour for forming expansion joint 20mm thick filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ in thickness of slab 150 mm. Complete all as specifed and as directed.
Labour only for Forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound Grage 'A'. Complete all as specifed and as directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5 cm and n exc 30 cm long, 12 mm dia. Complete all as specifed and as directed.
Material & Labour for preparation of new plastered surface of walls and applying two oil bound distemper over 1 mm thick putty including primer on wall. Complete all as specified and as directed
Dismantling of old unserviceable Gang operated device 11 KV of any description. Complete all as specifed and as directed.
Dismantling cross-arms of Mild Steel. channel or angle sections etc. complete and setting aside for re-use with in 50 metre. Complete all as specifed and as directed.
Dismantling old unserviceable lighthing arrestor of any description. Complete all as specifed and as directed.
Dismantling of ACSR or AAC conductors. Complete all as specifed and as directed.
Dismantling of old unserviceable earthings Including Strip and Test Point etc of any description Complete all as specifed and as directed.
Dismantling old unserviceable LT panels with accessories. Complete all as specifed and as directed.
Dismantling old unserviceable APFC panels with accessories. Complete all as specifed and as directed.
Supplying, installing connecting and testing of 11 KV 200 Amps triple pole gang operated air breack switch having 12 Nos post insulator with earthing switch rotating type for horizential/ vertical operation mechanically operated 3 rows type mounted on Polymer type insulator (including insulators) and steel frame with operating mechanism consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length to operated from ground level including locking arrangment with pad lock of godrej) make with three Nos of keys including 11 KV swing out expulsion fuses (drop out type) of 25 Amps. Complete all as specifed and as directed.
Material & Labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. Complete all as specifed and as directed.
Material & Labour for lightning arrestor expulsion type complete with all fittings, transmission class 11000 volts grade, discharge capacity 65 KA. Complete all as specifed and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts Earthed grade, of size 3 core 120 sqmm. Complete all as specifed and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts Earthed grade, of size 3 core 95 sqmm. Complete all as specifed and as directed.
Supply and fix cable jointing kit for 11 KV grade cable for out door termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 50 Sqmm to 95 Sqmm. Complete all as specifed and as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq 3.5 core. Complete all as specifed and as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq 3.5 core. Complete all as specifed and as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq 3.5 core. Complete all as specifed and as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq 3.5 core. Complete all as specifed and as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq 3.5 core. Complete all as specifed and as directed.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq 3.5 core. Complete all as specifed and as directed.
Excavation in trenches nexc 1.5 mtr in depth for taking out cable/ pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/ loose soil. Complete all as specifed and as directed.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm. Complete all as specifed and as directed.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point. Complete all as specifed and as directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading levelling watering and consolidation complete all as specified and directed. Note:- Punned thickness only shall be measured and paid
Material & Labour for reinforced precast concrete cable cover class LV, Type 1, flat as per IS -5280 of size 250 mm X 150 mm X 40 mm laid dry, flat abutting each other width wise. Complete all as specifed and as directed.
Material & Labour for earthing complete with galvanized steel earth plate electrode of size 60 cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 32 X 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20 mm dia protection pipe etc and testing on completion complete all as specified and as directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required Note No 3 :- PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
Material & Labour for earthing complete with Copper earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25 m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to Copper earth strip 20 mm X 3 mm as earth lead by means of bolts, nuts, check nuts and washers of Copper, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (Notes) under sub-heading earthing, specified on Serial Page No 389 of SSR Part –I. Note No 2 :- Earthing strip and GI protection pipe beyond 7.5 m will be measured and paid separately if required (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself. (Transformer neutral earthing)
Material & Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover with handle of 8 mm dia bar, charcoal/ salt, funnel with wire mesh etc. Complete all as specifed and as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1 using 20 mm graded stone aggregate, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself. (NOTE- 04 nos Eathing for Internal Electification and 02 nos for External Electrification)
Material & Labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 mm x 6 mm galvanised iron strip. Complete all as specifed and as directed.
Material & Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 mm x 3 mm copper strip. Complete all as specifed and as directed.
Material & Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire. Complete all as specifed and as directed.
Material & Labour for Test point terminal block made of gun metal or phosphorusbronze size 75 mm x 75 mm x 25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex. head screw. Complete all as specifed and as directed.
Material & Labour for replacement of cable jointing kit for 11 KV grade (Earthed) HT cable for indoor termination Cold shrinkable type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes Complete all as specifed and as directed. by EIC. Make: Birla 3M, Denson, Raychem.
(a) 50 sqmm to 95 sqmm
(b) 120 sqmm to 185 sqmm
Supply, installing, testing and commissioning factory made and tested LT feeder pillar box (KIOSK) outdoor type (with canopy) CPRI approved platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having Aluminum Bus Bar of minimum size 50 mm x 10 mm installed on DMC/ Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement, powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D2 using with 40 mm crushed stone aggregate 20 cm thick in foundation and of height 0.9 mtr above the nearest road level. Size of Panel must not be less than 1.6 Mtr x 1.2 Mtr x 0.35 Mtr. The TPN aluminium bus bar of rating not less than the 1.5 times (500 Amps capacity) the rated capacity of the incomer Microprocessor based MCCB with ICU = 100% ICS with following ratings:- Complete all as specifed and as directed. (i) Incoming MCCB 4P 315 Amps, 35 KA - 01 No (ii) Outgoing MCCB 3P 100 Amps, 25 KA - 02 Nos (iii) Outgoing MCCB 3P 63 Amps, 16 KA - 02 Nos (iv) Multi-functional meter with appropriate CT ratings and accuracy class. (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm (vi) Phase indicating LED lamps (R-Y-B) -01 set (vii) Spare chamber for MCCBs - 02 Nos Note : Pre-dispatch factory inspection shall be carried out by rep of Accepting Officer and expenditure for the same shall be deemed to be included in the quoted rates.
Supply, installing, testing and commissioning factory made and tested LT feeder pillar box (KIOSK) outdoor type (with canopy) CPRI approved platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having Aluminium Bus Bar of minimum size 40 mm x 10 mm installed on DMC/ Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement, powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D2 using with 40 mm crushed stone aggregate 20 cm thick in foundation and of height 0.9 mtr above the nearest road level. Size of Panel must not be less than 1.6 Mtr x 1.2 Mtr x 0.35 Mtr. The TPN aluminium bus bar of rating not less than the 1.5 times (400 Amps capacity) the rated capacity of the incomer Microprocessor based MCCB with ICU = 100% ICS with following ratings:- Complete all as specifed and as directed. (i) Incoming MCCB 4P 250 Amps, 36 KA -01 No (ii) Outgoing MCCB 3P 100 Amps, 25 KA -02 Nos (iii) Outgoing MCCB 3P 40 Amps, 16 KA -02 Nos (iv) Multi-Functional meter with appropriate CT rating and accuracy class (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm (vi) Phase indicating LED lamps (R-Y-B) -01 set (vii) Spare chamber for MCCBs - 02 Nos Note : Pre-dispatch factory inspection shall be carried out by rep of Accepting Officer and expenditure for the same shall be deemed to be included in the quoted rates.
Supply, installing, testing and commissioning factory made and tested LT feeder pillar box (KIOSK) outdoor type (with canopy) CPRI approved platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having Aluminium Bus Bar of minimum size 30 mm x 10 mm installed on DMC/ Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement, powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D2 using with 40 mm crushed stone aggregate 20 cm thick in foundation and of height 0.9 mtr above the nearest road level. Size of Panel must not be less than 1.6 Mtr x 1.2 Mtr x 0.35 Mtr. The TPN aluminium bus bar of rating not less than the 1.5 times (315 Amps capacity) the rated capacity of the incomer Microprocessor base MCCB with ICU = 100% ICS with following ratings :- Complete all as specifed and as directed. (i) Incoming MCCB 4P 200 Amps, 35 KA -01 No (ii) Outgoing MCCB 3P 63 Amps, 25 KA -02 Nos (iii) Outgoing MCCB 3P 40 Amps, 16 KA -02 Nos (iv) Multi-functional meter with appropriate CT ratings and accuracy class. (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm (vi) Phase indicating LED lamps (R-Y-B) -01 set (vii) Spare chamber for MCCBs - 02 Nos Note : Pre-dispatch factory inspection shall be carried out by rep of Accepting Officer and expenditure for the same shall be deemed to be included in the quoted rates.
Supply, installing, testing and commissioning factory made and tested LT feeder pillar box (KIOSK) outdoor type (with canopy) CPRI approved platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having Aluminium Bus Bar of min size 25 mm x 10 mm installed on DMC/ Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement, powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D2 using with 40mm crushed stone aggregate 20cm thick in foundation and of height 0.9 mtr above the nearest road level. Size of Panel must not be less than 1.6 Mtr x 1.2 Mtr x 0.35 Mtr. The TPN aluminium bus bar of rating not less than the 1.5 times (250 Amps capacity) the rated capacity of the incomer Microprocessor base MCCB with ICU = 100% ICS with following ratings :- Complete all as specifed and as directed. (i) Incoming MCCB 4P 160 Amps, 35 KA -01 No (ii) Outgoing MCCB 3P 40 Amps, 16 KA -04 Nos (iii) Multi-functional meter with appropriate CT ratings and accuracy class. (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of approriate size but not less than 2.5 sqmm (v) Phase indicating LED lamps (R-Y-B) -01 set (vi) Spare chamber for MCCBs - 02 Nos Note : Pre-dispatch factory inspection shall be carried out by rep of Accepting Officer and expenditure for the same shall be deemed to be included in the quoted rates.
Supply & Fixing in replacement of electrical Mat (Electromat) Class C, BIS + CPRI + ERDA approved, as per 15652 : 2006 Size 1 Mtr x 5 Mtr thickness 3 mm for system voltage 11 KV Min Colour Blue, Finish one side plain/ one side patterned (antiskid design having tensile strength of 15 N/mm for Temprature range of - 10 degree to 55 degree centigrade insulation resistance with water 1000000 mohm (Min) Leakage current 10 uA (Max) flame retardant No effect of Transformer Oil, Acid, Diesel Alkali. Complete all as specified and as directed by Engineer in Charge.
City Light
Dagli Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .