Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
8 Jun 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager (SR-Purchase)
Hindustan Shipyard Limited, Gandhigram, Visakhapatnam - 530005, 9493792172
Supply of Cooling Coils for INS Sujata
2020_HSL_81490_3
3700000452 / Cooling Coils
Open Tender
Miscellaneous Goods
Supply
14 days
Visakhapatnam
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
Exempted
7 Jul 2020
1 Jun 2020
8 Jun 2020
1 Jun 2020
8 Jun 2020
1 Jun 2020
90 days
Cooling coil for FCU, SPECS: MAKE: Carrier Transicold(i) System air volume : 800 M3/Hr(ii) Total static pressure : 12.7 mm Wg(iii) Cooling coil row : 4(iv) Cooling capacity : 4416 Kcal/ h(v) Entering water temp : 10 Deg C(vi) Leaving water temp : 15 Deg C(vii) Water flow rate : 14.72 LPM(viii) Coil water PD : 0.33 M.WgNecessary accessories like pressure gauges, and end fittings to beprovided.Installation <(>&<)> Commissioning Assistance is required
Cooling coil for FCU, SPECS: MAKE: Carrier Transicold(i) System air volume : 950 M3/Hr(ii) Total static pressure : 12.7 mm Wg(iii) Cooling coil row : 4(iv) Cooling capacity : 6726 Kcal/ h(v) Entering water temp : 10 Deg C(vi) Leaving water temp : 15 Deg C(vii) Water flow rate : 22.44 LPM(viii) Coil water PD : 0.58 M.WgNecessary accessories like pressure gauges, and end fittings to beprovided.Installation <(>&<)> Commissioning Assistance is required
Cooling coil for FCU, SPECS: MAKE: Carrier Transicold(i) System air volume : 400 M3/Hr(ii) Total static pressure : 3.81 mm Wg(iii) Cooling coil row : 4(iv) Cooling capacity : 2592 Kcal/ h(v) Entering water temp : 10 Deg C(vi) Leaving water temp : 15 Deg C(vii) Water flow rate : 8.67 LPM(viii) Coil water PD : 2.9 M.WgNecessary accessories like pressure gauges, and end fittings to beprovided.Installation <(>&<)> Commissioning Assistance is required.
Cooling coil for FCU, SPECS: MAKE: Carrier Transicold(i) System air volume : 700 M3/Hr(ii) Total static pressure : 3.81 mm Wg(iii) Cooling coil row : 4(iv) Cooling capacity : 3864 Kcal/ h(v) Entering water temp : 10 Deg C(vi) Leaving water temp : 15 Deg C(vii) Water flow rate : 12.87 LPM(viii) Coil water PD : 2.5 M.WgNecessary accessories like pressure gauges, and end fittings to beprovided.Installation <(>&<)> Commissioning Assistance is required.
Cooling coil for FCU, SPECS: MAKE: Carrier Transicold(i) System air volume : 900 M3/Hr(ii) Total static pressure : 12.7 mm Wg(iii) Cooling coil row : 4(iv) Cooling capacity : 5832 Kcal/ h(v) Entering water temp : 10 Deg C(vi) Leaving water temp : 15 Deg C(vii) Water flow rate : 19.45 LPM(viii) Coil water PD : 0.33 M.WgNecessary accessories like pressure gauges, and end fittings to beprovided.Installation <(>&<)> Commissioning Assistance is required.
RAO ELECTRICAL ENGINEERING WORKS
SRIKUSUMAHARA MARINE WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .