Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 52 VIJAY COLONY NEW CANTT ROAD DEHRADUN UK | L1 | Accepted-AOC Accepted | |
| 2 | L2₹16.4 L+₹70,366 (4.49%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.9 L+₹1.2 L (7.95%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹17.0 L+₹1.3 L (8.56%)Rejected-AOC VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹17.4 L+₹1.7 L (11.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
G E ROORKEE
G E ROORKEE
REPAIR TO ROOF CEILING AND MISC MISC ALLIED WORKS IN AGE B R II UNDER GE ROORKEE
2020_MES_402973_1
8391/980/E8
Open Tender
Civil Works
Item Rate
180 days
ROORKEE CANTT
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹50,000
Yes
23 Feb 2021
12 Dec 2020
11 Jan 2021
12 Dec 2020
9 Jan 2021
26 Dec 2020
60 days
Amount
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coering complete all as specified and directed.
S&F 6 mm thick asbestos cement, corrugated or semi corugated sheets in roof , walls etc fixed with L-type or J-type hook bolts complete all as specified and directed.
S&F 6 mm thick asbestos cement, (except sheets) corrugated or semi corugated sheets in roof , walls etc fixed with L-type or J-type hook bolts complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed
Dismantling wall and ceiling board (fibre, pulp , insulation etc) or insulation boards/ slabs any thickness complete all as specified and directed.
Providing and fixing tiled false ceiling of designer tiles(high pressure steam Cured) of 4mm thickness (as per IS:14862) of size 595x595mm and any one of the design ( Cascade or Electra or equivalent) in true horizontal level, suspended on inner locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grms, both side inclusive and black painted groove on all T webs) consisting of main “T” runner with suitably spaced joints to get required length and 15x32mm made from 0.3mm thick sheet, 1200mm long spaced between main “T” at 600mm C/C to form a grid of 1200x600mm and secondly cross “T” of length 600mm and size 15x32mm made of 0.30mm thick sheet to be interlocked at middle of 1200x600mm panel to form grids of 600x600mm and wall angle 15x20x0.36mm and laying false ceiling tiles in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanized butterfly level clips, spaced at 1200mm c/c along main “T”, bottom exposed width of 15mm of all “T” sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5 mm width, all complete at all heights as per directions of EIC. Make:- Everest / Armstrong / Gypsum India Ltd.
Dismantling wrought iron or mild steel work of any desc not other wise provided for complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section in any position complete all as specified and directed.
Dismantling framed timber fillets, rails, posts, rafters, purlins etc under 40 sq cm complete all as specified and directed.
S&F mild steel plates (plain or chequred) channels, square cut or notched (ordinary or counter sunk) forming holes, with riveted, bolted or welded attachment to Fe-410-W complete all as specified and directed.
S&F steel work in tubular trusses, purlins incl special shaped washer etc complete using ERWor induction butt welded tubes conforming to IS 1161- 1979 grade st -240 complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide paint complete all as specified and directed.
M&L for second class hard wood clean sawn hard wood in scantlings complete all as specified and directed.
M&L for providing cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate ) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Disconnecting existing tank , setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position complete all as specified and directedcapacity exc 250 n exc 500 ltrs complete all as specified and directed.
Taking up or down steel water tubing of 15 mm bore and connections incl cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down steel water tubing of 20 mm bore and connections incl cleaning for refixing or removal to store complete all as specified and directed.
S&F tubes 'medium grade' galvanised 15 mm bore with all fittings and fixed complete to walls and ceiling or laid under floors (open or concealed) complete all as specified and directed.
S&F tubes 'medium grade' galvanised 20 mm bore with all fittings and fixed complete to walls and ceiling or laid under floors (open or concealed) complete all as specified and directed.
Dismantling water tank of capacity exc 250 & n exc 500 ltrs complete all as specified and directed.
S&F rotational moulded polythene water storage tanks 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
S&F in repairs 20 mm bore ball valve high pressure of PTMT epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar or cement lime mortar incl all quoins , arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with old size sub class 'B' bricks , straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed
Taking down cement or cement lime plaster on brick or stone walls etc incl raking out joints, hacking for key , scrubbing down with water etc.
M&L for brick work with old size sub class 'B' bricks , straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed
M&L for rendering 15 mm thick in CM (1:6) on brick or concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on brick or concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick on concrete surface of ceiling in CM 1:4 complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Dismantling brick tiles or terracing tiles, single layer on roofs complete all as specified and directed complete all as specified and directed.
Demolition of mud in roofs andy thickness incl plastering and leeping (wheather full thickness removed or only a part thereof) complete all as specified and directed
M&L for providing cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in padding/ mass concrete using water proofing compound complete all as specified and directed
M&L for screed bed 15 mm thick in CM 1:4 (mixed with WPC) on concrete surface of roof finished fair and even before application of APP of roof treatment complete all as specified and directed
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement woth following: (a) M&L for surface preparation by removal or taking down existing treatment of tar felt/ base of PCC / roof plaster/ loose particle to ensure clean and smooth surface and preparing to receive plaster or PCC (b) Providing and laying a coat of cold applied bitumen 85/25 based primer on entire surface @0.30 ltr/sqm on dry and clean surface. (c) M&L for providing and laying APP based polymeric membrance of 3 mm thickness of weight of 3.0 kg/ sqm with non woven polyster fibre as reinforcement on primed surface by torch application with side laps & joints over laps etc as per manufacturer instruction. (d) M&L for finishing of top surface by two coats of aluminium paint over a coat of blown bitumen 85/25 grade @1.2 kg/ sqm grouted all as specified as per manufacturer instructions. (e) M&L for providing pond test with filling of watyer for continious 48 hours complete alla sspecified and directed
M&L for cutting out cracks 'V' section in existing roofs or terracing cleaning out , wetting grouting with CM 1:3 cement sand slurry on existing roof treatment for repair only complete all as specified and directed
M&L for 40 mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) complete all as specified and directed.
M&L for 40 mm thick brick tiles (except tiles) laid on mud mortar and joints grouted flush in cement mortar (1:3) complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for non skid joint free coloured ceramic tiles 7-8 mm thick (square/ rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, laid in flooring over & including 15mm thick screed bed in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x300x7/ 300x200x7mm thick, laid in vertical surfaces over & including 10 mm thick rendering in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F in repairs water closet vitreous china squatting pan 'Orissa' pattern size 580x440 mm white with integral foot rest (excl flusing cistern and flush pipe)complete incl provision of lime concrete & connection to trap incl trap complete all as specified and directed.
S&F in repairs PVC valveless syphonic action type flushing cistern, low level, coloured with inlet ball valve, float and handle incl bracket and flush pipe of polythene of low or high density of PVC 32 mm dia for low level cistern complete all as specified and directed.
Taking down chowkhat or frame with shutters ( (without taking off shutters from the frame) n.exc 1.5 Sqm complete all as specified and directed.
S&F solid PVC door frame of size 50 mm x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube , supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. Frame for top and bottom rails . M.S. Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, and bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frame at site as per specification & drawing
S&F PTMT butt hinges 100 mm complete all as specified and directed. Make: 'PRAYAG'
S&F PTMT tower bolt 200 mm complete all as specified and directed. Make: "PRAYAG'
S&F PTMT door handles 125 mm complete all as specified and directed. Make: 'PRAYAG'
Demolition or breaking up drain pipe (saltglazed ware, AC or reinforced) of any dia complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints, laid in floors or in trenches or to walls complete all as specified and directed. ISI marked
S&F PVC (SWR) bends of 110 mm bore of any radius complete all as specified and directed. ISI marked
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even & fair with using extra cement complete all as specified and directed.
Demolition of cement concrete above ground floors and pavings exc 15 cm thickness of any description not otherwise described
M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 using integral water proofing compond for both floor and sides of wall in sunken floor complete all as specified and directed. (WPC shall be measured separately)
M&L for Bituminous water proofing treatment by applying bitumen coat @ 3.00 Kg per Sqm for receiving APP Memberane complete all as directed by Engr-in-Charge
M&L for laying APP memberane of 3.5 Kg Per Sqm including overlapping and sealing complete all as specified and directed
M&L Plain cement concrete1:4:8 type D-2 (using 40mm graded brick aggregate) in filling in sunken floors complete all as specified and directed.
M&L for removing plants/herbs grown on wall/junctions/CI pipe tee junctions with roots duly cuttings necessary holes and applying herbicide chemical and making good of the existing brick/concrete surfaces complete all as specified and direced (Note : Necessary scaffolding upto four story buildings deemed to be including in the unit rate)
Alankar Traders
M/S RAJESH ARORA
AMAR NATH SHARMA
M/S A.K GARG
m/s rajesh bros.
RAJENDER CONSTRUCTION CO
VAIBHAV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .