Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.7 L+₹1.2 L (3.73%)Rejected-Finance | L2 | Rejected-Finance Rejected due to high rate from L1 | |
| 3 | L3₹34.3 L+₹1.9 L (5.75%)Rejected-Finance 71 A LOOTERY MAHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Rejected due to high rate from L1 | |
| 4 | L4₹35.3 L+₹2.8 L (8.76%)Rejected-Finance 32 LOOTERY MOHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L4 | Rejected-Finance Rejected due to high rate from L1 | |
| 5 | L5₹35.9 L+₹3.4 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Rejected due to high rate from L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Jul 2023, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / MAINT / REPLACEMENT OF LT DISTRIBUTION SYSTEM, APFC PANEL AND CONNECTED WORKS INCLUDING IMPROVEMENT TO SUB-STATION ACCESSORIES AT BARRACKPORE UNDER GE (AF) BARRACKPORE
2023_MES_603065_1
8459/BKP/AF OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Barrackpore
Class-D,
Category-b(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹60,000
Yes
21 Aug 2023
13 Jun 2023
19 Jul 2023
13 Jun 2023
17 Jul 2023
27 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth and getting out in soft/loose soil for laying of under ground cable complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed.
Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Materials and labour for boring for passing GI protection pipe up to 80 mm bore (dia) under road / footpath without disturbing the top surface complete all as specified and directed Note-Necessary infrastructure required for boring shall by arranged by the contractor and cost of the same included in quoted rates.
Taking down / out un-serviceable or serviceable LT UG Cables of size 185 sqmm 3.5 core and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and / or fixing with walls / poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc. and keep in safe custody for re-use, complete all as specified and as directed. Note:- Earth work shall be measured and paid separately under respective items.
All as per Item No. 5.00 above, but of size 120 sqmm 3.5 core and -ditto-.
All as per Item No. 5.00 above, but of size 95 sqmm 3.5 core and -ditto-.
All as per Item No. 5.00 above, but of size 70 Sqmm 3.5 core and -ditto-.
All as per Item No. 5.00 above, but of size 50 Sqmm 3.5 core and -ditto-.
All as per item No 5.00 above but of size 16 smm 4 core and -ditto-.
Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 185 Sqmm, 3.5 core, 1100 Volts (earthed) grade, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trenches etc. with brass compression cable gland, terminal lugs, etc complete all as specified and directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
All as per Item No. 11.00 above, but of size 120 sqmm 3.5 core and -ditto-.
All as per Item No. 11.00 above, but of size 95 sqmm 3.5 core and -ditto-.
All as per Item No. 11.00 above, but of size 70 sqmm 3.5 core and -ditto-.
All as per Item No. 11.00 above, but of size 50 sqmm 3.5 core and -ditto-.
All as per Item No. 11.00 above, but of size 16 sqmm 4 core and -ditto-.
Re-laying, connecting and testing XLPE insulated, armoured, electric power UG cable (heavy duty) with aluminium conductor, 1100 Volt grade of size 185 Sqmm 3.5 core core including brass compression cable gland, terminal lugs, etc. complete all as specified and directed. Note : (i) Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. (ii) Servciable cables obtained from item No. 5.00 shall be reused under this item.
All as per Item No. 17.00 above, but of size 120 Sqmm 3.5 core and -ditto-. Note : (i) Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. (ii) Servciable cables obtained from item No. 6.00 shall be reused under this item.
All as per Item No. 17.00 above, but of size 95 Sqmm 3.5 core and -ditto-. Note : (i) Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. (ii) Servciable cables obtained from item No. 7.00 shall be reused under this item.
All as per Item No. 17.00 above, but of size 70Sqmm 3.5 core and -ditto-. Note : (i) Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. (ii) Servciable cables obtained from item No. 8.00 shall be reused under this item.
All as per Item No. 17.00 above, but of size 50Sqmm 3.5 core and -ditto-. Note : (i) Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. (ii) Servciable cables obtained from item No. 9.00 shall be reused under this item.
All as per Item No. 17.00 above, but of size 16 Sqmm 4 core and -ditto-. Note : (i) Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item. (ii) Servciable cables obtained from item No. 10.00 shall be reused under this item.
MMaterial and labour for sand cushioning with clean and dry river sand for protection of XLPE UG cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and directed. Note:- Punned down thickness shall be measured for payment.
Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
Labour only for re-laying old brick in trenches for protection of under ground cable complete all as specified and directed. Notes:- Serviceable bricks obtained from item No 5.00 to 10.00 shall be reused under this items.
Supply and fix in repair steel tubing of size 80 mm dia (light grade) with all fittings, laid in trenches / road crossing / fixed on wall / pole with mild steel clamps, nuts, bolts, etc. for protection of cables complete all as specified and directed.
Supply and fix in repair steel tubing of size 50 mm dia (light grade) with all fittings, laid in trenches / road crossing / fixed on wall / pole with mild steel clamps, nuts, bolts, etc. for protection of cables complete all as specified and directed.
Material and labour for repair of LT feeder pillar box complete including dismantling of burnt-out cable connections, bus-bars, MCCBs etc and preperation of external surfaces and apllying one coat of synthetic enamel paint, refixing of bus-bars, serviceable MCCBs, all cable connection from busbar to terminals at both ends and replacement of epoxy cast busbar, insulators etc. including patch repair with electric welding for replacement of hinges, refixing of broken doors, replacement of locking arrangement with sliding bolts including PCC for reconstruction of foundation/coping etc. complete all as specified and directed. NOTE : Cable connector required for replacement & required PCC for reconstruction of foundation / coping will be measured and paid separately under respective items.
Supply and fix in repair cable connector of length 0.5 m, made out of 25sqmm multi-stranded copper conductor single core PVC inner sheathed un-armoured cable including copper lugs, copper nut bolts etc.complete all as specified and directed.
Supply and fix in repair cable connector of length 0.5 m, made out of 35sqmm multi-stranded copper conductor single core PVC inner sheathed un-armoured cable including copper lugs, copper nut bolts etc. complete all as specified and directed.
Supply and fix in repair cable connector of length 0.5 m, made out of 50sqmm multi-stranded copper conductor single core PVC inner sheathed un-armoured cable including copper lugs, copper nut bolts etc.complete all as specified and directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) including demolition of brickwork or stone/boulder masonary built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-1 (using 20 mm grade stone aggregate) for kerbs, coping etc chamfered edges including form work including demolition of existing cement concrete (unreinforced) of any spaecififcation and removal of rubbish from the site complete all as specified and directed
Supply and fix in repair straight through (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC / XLPE insulated aluminium stranded conductor of size exc16 sqmm but not exc. 50 sqmm, 3.5 / 4 Core and testing complete all as specified and directed.
Supply and fix in repair straight through (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC / XLPE insulated aluminium stranded conductor of size exc 70 sqmm but not exc. 95 sqmm, 3.5 core and testing complete all as specified and directed.
Supply and fix in repair straight through (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC / XLPE insulated aluminium stranded conductor of size exc 120 sqmm but not exc. 185 Sqmm, 3.5 core and testing complete all as specified and directed.
Supply and fix in repair end termination (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC / XLPE insulated aluminium stranded conductor of size exc. 185 sqmm but not exc. 300 sqmm, 3.5 core and testing complete all as specified and directed.
Supply and fix in repair end termination (epoxy) cable joint kit including jointing materials for making joints of UG electric cable 1100 Volt grade heavy duty with PVC / XLPE insulated aluminium stranded conductor of size exc. 400 sqmm but not exc. 500 sqmm, 3.5 core and testing complete all as specified and directed.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT feeder pannel board (CPRI Approved), outdoor type, double door, factory made out of 3.15 mm thick CRCA sheet of size 1.2 m x 1.00 m x 0.5 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland and gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc including necessary excavation work for taking out cable loop, foundation of panel board and refilling and comprising of the following accessories:- (a) Anodized Copper bus bar of capacity 600 Amp -04 Nos (b) MCCB 320 Amp fixed thermal and magnetic release type, 415 Volts 4 pole, 36 KA - 01 Nos ( In coming). (c) MCCB 160 Amp fixed thermal and magnetic release type, 415 Volts 4 pole, 25 KA - 02 Nos (Out going). (d) MCCB 125 Amp fixed thermal and magnetic release type, 415 Volts 4 pole, 16 KA - 02 Nos (Out going). (e) Indicator lamp LED type (set of three Red,Yellow,Blue)- 1 Nos. Including taking down old unserviciable panel board complete all as specified and directed.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT feeder pannel board (CPRI Approved), outdoor type, double door,factory made out of 3.15 mm thick CRCA sheet of size 0.60 m x 0.60 m x 0.5 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc including necessary excavation work for taking out cable loop, foundation of panel board and refilling and comprising of the following accessories:- (a) Anodized Copper bus bar of capacity 400 Amp -04 Nos. Including taking down old unserviciable panel board complete all as specified and directed.
Material and labour for preperation of old painted surface of panel board and applying one coat of synthetic enamel paint by spray painting complete all as specified and directed.
Material and labour for disconnecting of APFC panel from all incomming / outgoing connection of any capacity, checking the serviceability of all components i.e. existing capacitors, contactors, MCB, MCCB, indicator lights, power factor controller, replacement of burnt out PVC insulated copper wire of existing size, copper thimble, MCB SPN 'C' Series (6-32Amp) 10KA, re-connect the same after throughly clean, and fixed the spare parts and testing complete all as specified and as directed. Note:- Spare parts as required shall be measured & paid separately under respective items as supply only.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 5 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 7.5 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 10 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 12.5 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 15 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 20 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 25 KVAR complete all as specified and as directed.
Supply only capacitor duty contactors of capacity 5 KVAR rating @ 415 Volt 3 phase (including 1 NO + 1 NC) complete all as specified and as directed.
Supply only capacitor duty contactors of capacity 8.5 KVAR rating @ 415 Volt 3 phase (including 1 NO + 1 NC) complete all as specified and as directed.
Supply only capacitor duty contactors of capacity for 12.5 KVAR rating @ 415 Volt 3 phase (including 1 NO + 1 NC) complete all as specified and as directed.
Supply only indicator lamp LED type colour (Red/Yellow/Blue/Green of any) complete all as specified and as directed.
Supply only power factor controller of capacity 8 step 440 volt, 3 phase 50 Hz complete all as specified and as directed.
Suplly and fix in repair MCCB, 630 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 50 KA, fixed thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 400 Amps, 4 pole, 415 Volt, 50 Hz, Breaking capacity 36 KA, fixed thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair MCCB, 320 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, fixed thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair MCCB, 250 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, fixed thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair MCCB, 160 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, fixed thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair MCCB, 4 pole, 125 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair MCCB, 4 pole, 100 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair MCCB, 4 pole, 63 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic setting type complete all as specified and directed.
Suplly and fix in repair ACB 4 Pole, 415 V, 630 Amp, 50KA with thermal magnetic release (manual fixed type) complete all as specified and directed.
Suplly and fix in repair switch disconnector fuse unit complete with HRC fuse of capacity 250 Amp, 415 Volt, 4 pole, 50 Hz in open execution type with fuse complete all as specified and directed.
Suplly and fix in repair switch disconnector fuse unit complete with HRC fuse of capacity 200 Amp, 415 Volt, 4 pole, 50 Hz in open execution type with fuse complete all as specified and directed.
Suplly and fix in repair switch disconnector fuse unit complete with HRC fuse of capacity 160 Amp, 415 Volt, 4 pole, 50 Hz in open execution type with fuse complete all as specified and directed.
Suplly and fix in repair on load change over switch (open execution) complete with of capacity 200 Amp, 415 Volt, 4 pole, 50 HZ complete all as specified and directed.
Suplly and fix in repair on load change over switch (SS enclousure) complete with of capacity 100 Amp, 415 Volt, 4 pole, 50 HZ complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 50 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 70 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 95 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 120 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 185 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 240 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 400 sqmm x 4 core with E-bolt hole complete all as specified and directed.
Material and labour for shifting of indoor / outdoor type LT panel board of any size with all accessories after disconection of outgoing and incomming cables, earth strips etc. and taking away from existing location and re-installation on the P.C.C./ brick platform duly grouted in the new platform constructed within 15 mtr from the existing location including reconnection of all outgoing and incomming cables, complete all as specified and directed. Note:PCC/brick work to be measured and paid under respective items.
Material and labour for 100mm thick cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in paving / footpath / sub stn) and finished the surface fair and even including making the surface clean by cutting any type of vegetation including demolition of old damaged existing PCC surface complete all as specified and directed.
CHANDRA CONSTRUCTION AND CO
KUMAR ENTERPRISE
Das and Brothers
TAPAS ENGINEERING CO
R K CONSTRUCTION
PIONEER
SARKAR AND COM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .