Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹47.5 L+₹1.5 L (3.30%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
PROVISION OF LBW AND MINOR WORKS UNDER AGE E/M AT AF STN BARODA
2022_MES_557178_2
8749/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹90,000
Yes
21 Jan 2023
10 Nov 2022
9 Dec 2022
10 Nov 2022
7 Dec 2022
24 Nov 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and directed
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep and getting out in hard /dense soil complete all as specified and directed
Returning, filling excavated soil in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and directed Note: - Thickness after punning will be measured for payment.
Supply and fix PCC Cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm LV flat complete all as specified and directed
Supply and fix red clay brick cable cover, class LV, flat size 230mm x 115mm x 75mm complete all as specified and directed
S & F low density polyethylene pipes of pressure rating 6 kgf/Sqcm 50 mm bore with all fittings, fixing on wall /laid in trenches trenches for cable protection complete all as specified and directed
Supply, Install, testing & commissioning of automatic, unbalanced type three phase Oil Cooled Line Servo Voltage Stabilizer of rating 250 KVA , copper wound, efficiency 98-99% , As per IS 9815 Standards, 24 Hrs duty cycle, incl. High & Low Voltage Cut Off ( HLVC ) ,Control through Micro Processor Controller/1C based solid state plug in type glass epoxy control Card, All the three phases controlled individually for better voltage and load management,Suitable for all power factor loads, 98-99% efficiency being achieved by optimum design and by use of high quality CRGO lamination and 99.9% pure copper, Single Phasing Protection ( SPP ) & first filling of transformer oil . The three phase Oil Cooled Line Servo Voltage Stabilizer must have the following features :
a) I/P Voltage Range : 300V - 480 V. (b) Out put range : 400V+ 1%, & Output Adjustment- 380 – 415 V AC c) Type : Suitable for Unbalance/Balanced input and blanced and Unbalanced load Type. d) Response Time : less than 10 ms e) Output Voltage Regulation : 1% of the set value. f) No Load Losses : Less than 1%. g) Effect of PF on O/P Voltage : NIL. h) Waveform distortion on O/P Voltage : NIL. i) Winding Wires : Pure electrolyte grade copper wires. j) Type of Cooling : Oil Cooled. k) Mounting : On Wheels. l) Additional Facilities : Alarm Annunciator & Manual Operation. (m) Metring : Digital display (n) Protection :-Under / Over Voltage Cut off Protection,Overload / Short Circuit Protection, Manual Bypass – Changeover,MCCB of suitable rating,Surge Protection using SPD, Class C,Single Phase Prevention
Supply, Install, testing & commissioning of automatic, unbalanced type three phase Oil Cooled Line Servo Voltage Stabilizer of rating 150 KVA , copper wound, efficiency 98-99% , As per IS 9815 Standards, 24 Hrs duty cycle, incl. High & Low Voltage Cut Off ( HLVC ) ,Control through Micro Processor Controller/1C based solid state plug in type glass epoxy control Card, All the three phases controlled individually for better voltage and load management,Suitable for all power factor loads, 98-99% efficiency being achieved by optimum design and by use of high quality CRGO lamination and 99.9% pure copper, Single Phasing Protection ( SPP ) & first filling of transformer oil . The three phase Oil Cooled Line Servo Voltage Stabilizer must have the following features :
a) I/P Voltage Range : 300V - 480 V. (b) Out put range : 400V+ 1%, & Output Adjustment- 380 – 415 V AC c) Type : Suitable for Unbalance/Balanced input and blanced and Unbalanced load Type. d) Response Time : less than 10 ms e) Output Voltage Regulation : 1% of the set value. f) No Load Losses : Less than 1%. g) Effect of PF on O/P Voltage : NIL. h) Waveform distortion on O/P Voltage : NIL. i) Winding Wires : Pure electrolyte grade copper wires. j) Type of Cooling : Oil Cooled. k) Mounting : On Wheels. l) Additional Facilities : Alarm Annunciator & Manual Operation. (m) Metring : Digital display (n) Protection :-Under / Over Voltage Cut off Protection,Overload / Short Circuit Protection, Manual Bypass – Changeover,MCCB of suitable rating,Surge Protection using SPD, Class C,Single Phase Prevention
Supply and laying XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 150 Sqmm 3.5 core laid in trenches or passing through pipes.ducts or fixed to walls/poles complete all as specified. Note: Earth work, cable protection and sand cushioning shall be measured and paid for separately
Supply and laying XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 240 Sqmm 3.5 core laid in trenches or passing through pipes.ducts or fixed to walls/poles complete all as specified. Note: Earth work, cable protection and sand cushioning shall be measured and paid for separately
S&F MCB SPN DB 12 Way 240 volts, 50 HZ with IP 42 protection, double door with 200 Amp standard bus bar of suitable size complete all as specified and directed
S&F MCB SPN DB 8 Way 240 volts, 50 HZ with IP 42 protection, double door with 200 Amp standard bus bar of suitable size complete all as specified and directed
S & F MCB SP 6 to 32 Amp, 240 volts complete all as specified and directed
S & F MCB SPN 40 to 63 Amp, 240 volts complete all as specified and directed
M&L for earthing complete with copper earth plate 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3.15 mm as earthing lead by means of bolt ,nuts, check nuts and washer of steel besides welding of all joints as shown in drawing and including excavation and earthwork, G.I.pipe light grade 25 mm bore for protection of copper strip from earth electrode to incl the earth test point supplying and laying charcoal dust, common salt PCC 1:2:4 type CI chamber and MS angle iron frame 40x40x3mm RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe medium graded for watering all as shown in drawing and connected to earth test point incl testing complete all as specified and directed
Supply and fix copper strip 20 mm x 3.15 mm complete with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F Epoxy insulator earthing strip insulator with nut bolt in red colour suitable for copper strip 20mm x3.15 mm for fixing on wall / roof for complete all as specified and directed.
Supply and fix test point block of 50mm long copper strip 32x6mm terminal block made of GI Sheet box of size 90x90x90mm made of 1.6mm plain sheet and screwed to wall for protection of test point complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork where required complete all as specified and directed.
Supply and laying & testing 25 sqmm 3.5 core XLPE cable PVC insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable , (heavy duty), 1100 volts grade with stranded aluminium conductor complete all as specified and directed
M&L for cutting into existing steel tubing of dia 80 mm for laying/fixing of new connection of any size complete all as specified and directed
M&L for screwing existing steel tubing of dia 80 mm for laying/fixing of new connection of any size complete all as specified and directed
S & F gun metel gate/globe valve size 50 mm bore with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed . Note. rate of union/socket included in quoted rate.
S & F gun metel gate/globe valve size 25 mm bore with iron wheel head,screwed both ends for iron pipe and fixed complete all as specified and directed . Note. rate of union/socket included in quoted rate.
S & F 50 mm bore Galvanized Steel tubes, medium grade with all fittings such as socket, elbow, bends, tee etc fixing on wall /laid in trenches complete all as specified and directed
S & F 25 mm bore Galvanized Steel tubes, medium grade with all fittings such as sockets, elbow, bends, tee etc fixing on wall /laid in trenches complete all as specified and directed
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including GI pipe light grade of 100 mm dia suitable for road crossing complete all as specified and directed.
Supply laying connecting, jointing and testing of pipe ductile Iron , flanged end, Class “K-9” ,100 mm (4”) dia,IS:8329 specified ,Bituminous Paint Coated in any length, laid in trenches and including Nut Bolts and Flange Rubber Gasket of 3 mm thickness complete all as specified and directed.
M&L for Taking up or down 80mm DI tubing and connections of any size/dia complete all as specified and directed Note: Earth work will be measured and paid saperatly.
M&L for refixing 80mm DI pipe tubing and connections including providing Tyton joint of any size/dia complete all as specified and directed
M&L for cutting existing pipeline of 80 mm dia including providing 80 x 80 x 80 mm dia tee 01 no &, threading for new pipe connection all as specified and directed.
Supply, installation, connecting and testing sluice valve 100 mm dia, cast iron body (long body) class PN- 1.6 with flanged ends drilled, ISI marked having stainless steel spindle with iron wheel at top complete with and including nuts, bolts, washers, rubber gasket etc including taking down old UNSV sluice valve complete all as specified and as directed
Supply, installation, connecting and testing sluice valve 80 mm dia, cast iron body (long body) class PN- 1.6 with flanged ends drilled, ISI marked having stainless steel spindle with iron wheel at top complete with and including nuts, bolts, washers, rubber gasket etc including taking down old UNSV sluice valve complete all as specified and directed
Supply, installation, connecting and testing vertical Bronze check valve/ NRV valve 100 mm dia, cast iron body (long body) class PN- 1.6 with flanged ends drilled, ISI marked having stainless steel spindle with iron wheel at top complete with and including nuts, bolts, washers, rubber gasket etc including taking down old UNSV valve complete all as specified and directed
Supply, installation, connecting and testing NRV valve 100 mm dia, cast iron body (long body) class PN- 1.6 with flanged ends drilled, ISI marked having stainless steel spindle with iron wheel at top complete with and including nuts, bolts, washers, rubber gasket etc including taking down old UNSV valve complete all as specified and directed
Supply, installation, connecting and testing Air Release Valve 80 mm dia, cast iron body (long body) class PN- 1.6 with flanged ends drilled, ISI marked having stainless steel spindle with iron wheel at top complete with and including nuts, bolts, washers, rubber gasket etc complete all as specified and directed
Supply, connecting, jointing of DI special such as bend, tees, collar etc complete all as specified and directed.
M & L for construction of Mild steel Header 350 mm dia and minimum 3 mtr long with provision of 3 nos incoming and 6 nos out going all as directed by Engr-in-chrage by using MS connecting pieces both end flanged and other end reducers/bell mouth pieces, bends, blanking plate, tapers any type and radius and angle, tee pieces, single brach,both end flanged including gas welding machine and electric welding to required length including required size of bends, tees, flanges, nuts, bolts and washers, rubber gasket etc for provision of water pressure head including lathe work finishing and painting with approved paint, all ends socket, all ends flanged of size up to 350 mm made out of MS plate suitable thick conforming to Fe 410-0 or Fe-310-0 complete all as specified and directed painting two coats of enamel paint over a coat of red oxide primer complete all as specified and directed Note. rate of welding/end cape/dismantling of existing header etc any type of arrangement for fixing is included in item rate, no exta payment should be made to contracter.
M & L for construction of new valve pit 1.5 m x 1.5 m x 1.8 mtr with bottom 15 cm thick PCC 1:4:8 D-2 and brick work with sub class B brick in 1:6 cement mortar plastered from in side and out side, angle iron frame of 80 mm x 80 mm x 5mm with GI sheet 3 mm thick double opening gate including locking arrangement and painting two coats of enamel paint over a coat of red oxide primer complete all as specified and directed including dismantling of old valve pit complete all as specified and directed
M & L for pressure switch Range 4-17 Bar and Adjustable Differential : 1.2 to 4 Bar One SPDT microswitch of release/tripping mechanism of starter on pressure7 Bar header including control wire, auxiliary contactor, sensor, contacter etc complete all as specified and directed Note :- The pressure switch is to be installed with existing pump to release/tripping mechanisn/ectro-mechanical device which triggered by pressure to turn an electrical circuit on or off when pressure in pipe line/on pump increase.
S & F 20 mm bore Galvanized Steel tubes, medium grade with all fittings, fixing on wall /laid in trenches complete all as specified and directed . Note rate of union/ tee/bend/socket included in item rate.
M&L for Taking up or down GI tubing and connections of 20 mm dia complete all as specified and directed
M&L for Refixing old steel tubing and connections 20 mm in new or old position (Walls, ceiling, floors, etc Complete all as specified and directed.
S & F DOL starter suitable for 1 HP single phase 240V PUMP SET fixed on wall complete all as specified and directed.
S & F self priming PUMP SET 1 HP single phase 240 v, head 3-42 m, maximum flow rate 2600 LPH suitable for 25 mm bore suction and delivery pipe complete Including MS sheet (thickness 1,6mm) weather proof canopy moveable of suitable size as directed by Eng-in-Charge and PCC foundation made out of PCC 1:2:4 of size 1m x 1m x 0.4 m(H) complete all as specified and directed
Supply & lay submersible cable, flexible, weather proof, stranded copper conductor double insulated PVC insulated and sheathed flat cable 3 core 2.5 sqmm multistranded fixing on wall/roof including flexible pvc pipe complete all as specified and directed.
S & F DOL starter suitable for 1 HP/ .75 KW single phase 230V PUMP SET fixed on wall complete all as specified and directed.
S & F openwell submersible pump set 1 HP single phase head 18-32 Mtr, discharge 2.2 lps- 0.3 lps PUMP SET suitable for 25 mm bore suction and delivery complete all as specified and directed.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including GI PIPE light grade 50 mm dia suitable road crossing complete all as specified and directed
M & L Sub Main wiring along with earth wire Single Core HRFR PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volt Conforming to IS 694 suitable for with 220Volt ,1 Ph 50 Hz wiring of size 2x16 sq mm and 16 sq mm earth wire of connectivity of FRLS PVC insulated copper conductor , single core cable in surface/recessed as required in PVC conduit/caping casing complete all as specified and directed Note- All run of 3 x 16 sqmm PVC wire and 1 run of conduit casing caping shall be measured and paid as 1 mtr length of unit.
Supply and Fixing of sheet metal enclosure with 63 Amp MCB , with 415 V socket, plug top enclousre with four pin and earth plug socket with one single pole 63Amp MCB complete all as specified and directed
Material and Labour for brazing of Earthing copper strips at various locations of size 25mm-50mm width of thick ness 3mm-6mm by using Oxygen and acetylene gas cylinder with copper rod material, Including removing of existing nut, bolts and insulator and refixing after brazing of strip joints except testing point of each earthing complete all as specified and directed Note-: 1. Any damage of building portion during working time will be repaired and made good to match with existing area. cost for making good deemed included in quoted rates of item. 2. Contractor shall be responsible to replace old warnout nut,bolt and insulators with new material.Cost of material also deemed included in quoted rate.
Supply & Fixing of Arial Bunched Cable (ABC) of size 3Core X 16 Sqmm + 25 Sqmm (Insulated) 1.1 KV grade stranded and compacted Aluminium phase conductors, and stranded messanger conductor with All Aluminium Alloy,Phase conductor is insulated with XLPE (Sioplas) compound ,Messanger is insulated with lighting conductor of 16 Sqmm with IS : 14255 -1995 Including cable hanging/fixing on existing LT PCC poles with necessary fixing arrangement suggested by OEM complete all as specified and directed Note -: All fixing accessories used for hanging of cable on PCC pole to be measured and paid seperately.
Supply and fixing of following accessories suitable for hanging and suspension of 3 Core x 16 Sqmm +25 Sqmm (insulated) ABC cable on exisiting LT pole complete all as specified and directed
Dead end clamp
Suspension Clamp with running out Device
Cable protection
Hook Plates
Universal Brackets
Suspension Hook Steel
Insulator & rubber insert
Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed
M&L for sub main wiring using two run single core 6 Sqmm fire retardent PVC insulated and unsheathed cable with copper conductor 1100 vots, grade, ISI mrked complete with PVC casing caping / conduit with accessories like bends tees etc FR PVC insulatd copper cable 4 Sqmm for earth wire and connecting to earth dolly complete all as specified and directed Note: (i) Two runs of 6 sqmm and one run of 4 sqmm cable and one run of PVC conduit / casing caping shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
Supply and fix electronic meters tamper proof LCD display with polycarbonate cover 230 V, 1P LCD Meter 10-60A with Optical Port + BOX , accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. Make CAT Part No WM101BC7DDHBOX of L&T or equivalent in make as specified
Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia unto 7.5 from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. Complete all as specified and directed
Supply and fix GI tubing light grade 50 mm for protection of cable at wall/trench with fixing accessories as directed. Note Unit rate include Cutting on Road or walls making good. The surface with plaster or PCC 1:2:4 as required at site Complete all as specified and directed
Material and labour for boring of roads/ hard cemented surface for insertion of 40 mm GI tubing light grade for laying of cable including the 40 mm dia GI tubing light grade pipe complete all as specified and directed
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including modular metal flush box made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of modular white cover plate over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch Complete all as specified and directed
Supplying & fixing modular switch, single pole one way 6 Amps, 230 volts AC circuit complete all as specified & directed
S&F Ceiling fan 1200 mm sweep 5 Star Rating wirh BLDC technology 32 watt with dust resistant including Remote controlled regulator, connecting wire PVC insulated flexible 0.5 sqmm copper conducter canopy set, down rod, Shackle Kit, and Twisted Wire Complete all as specified and directed
Surface excn n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
M&L for hardcore of broken stone or boulder of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed
M & L for cement concrete 1:4:8 type D 2 using 40 mm .graded aggregate in foundation complete all as specified and directed
M&L for brick work in sub class B bricks straight or curve on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed
M&L for reinforced cement concrete type A1 1:1.5:3 (20mm graded aggregate) in foundation incl raft footing, foundation beams, plinth beams, bases of columns etc all as specified complete all as specified and directed
M&L for reinforced cement concrete type A1 1:1.5:3 (20mm graded aggregate) in columns complete all as specified and directed
M&L for reinforced cement concrete type A1 1:1.5:3 (20mm graded aggregate) in beam, cantilevers, lintels etc and the like complete all as specified and directed
M&L for reinforced cement concrete type A1 1:1.5:3 (20mm graded aggregate) in slabs supported on walls, beams and columns in floor landing and the likecomplete all as specified and directed
M&L for reinforced cement concrete type A1 1:1.5:3 (20mm graded aggregate) in chajjas complete all as specified and directed
M&L for TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for colums, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia complete all as specified and directed
M&L for TMT bars 6mm to 8 mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for colums, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia complete all as specified and directed
Use & waste of form work for rough finished flat surfaces to sides of concrete of foundation, footings, bases of columns and similar work vertical or to batter complete all as specified and directed
Use & waste of form work for rough finished flat surfaces of concrete in beams, lintels incl support etc Complete all as specified and directed
Use & waste of form work for rough finished sides of pillars post, struts piers, columns and stanchions etc. Complete all as specified and directed
Use & waste of form work for rough finished flat surfaces of concrete in chajja/shelves. Complete all as specified and directed
Use & waste of form work for rough finished soffits of suspended slabs, landing & similar works n.exc 200 mm thick etc. Complete all as specified and directed
M&L for shingle filling in floors or pavings, laid in layers n.exc 15 cm thick spread, levelled and blinded with earth and rammed incl watering Complete all as specified and directed
M&L for rendering 15mm thick in two layers, first coat 10mm thick in CM 1:4 and second coat 5mm thick in CM 1:4 mixed with water proofing compound @ 3% by weight of cement on concrete block masonry surfaces finished even and smooth without using extra cement Complete all as specified and directed
M&L for rendering 5mm thick in CM 1:3 on ceiling including water proofing compound Complete all as specified and directed
M&L for 10 mm thick rendering on fair faces of concrete surfaces in CM 1:6 and finished even and smooth without using extra cement Complete all as specified and directed
Preparing new surfaces plastered or unplastered & applying three coats of white wash on wall surfaces Complete all as specified and directed
Preparing new surfaces plastered or unplastered & applying three coats of white wash on ceiling surfaces Complete all as specified and directed
M&L for two coat of cement based paint on newly plastered surface after one coat of primer with alkali resistent priming coat including preparation of surface Complete all as specified and directed
M&L for applying cold bituminous primer @ 0.30 ltr/Sqm conforming to IS 3384 and laying APP polymer modified fiber glass reinforced membrane 3mm thick 3.5Kg/Sqm (modified bituminous water proofing membrane) with plain finish with ploystere base reinforcement sealing all the over laps of 75 mm in length side and 100 mm on the width side of membrane by torching the same all as per manufacturer instruction including one coat of butuminous aluminum paint @ 0.10 ltr/sqm over membrane complete all as specified and directed.
S&F 150mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 100mm Butt hinges medium weight, cold rolled mild steel complete all as specified and directed
S&F 150mm anodised aluminium handle cast type complete all as specified and directed
M&L Powder coated Anodised aluminium Jalli/frame/shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed
S&F, 5mm thick Figured glass, pin head type and glazing with oil putty or wooden beads in squares n exc 0.5 sq. m in each pane Complete all as specified and directed
Excavating in post holes ( or similar holes ) each n.exc 0.5 cum getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface in hard/dence soil. Complete all as specified and directed
M&L for PCC 1:3:6 type C2 as in foundation, filling and mass concrete. Complete all as specified and directed
M&L Plain cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base to flooring 75mm thick finished surfaces even and rough to receive the flooring etc without using extra cement, complete all as specified and directed
M&L Plain cement concrete type B-2 1:2:4 (using 40mm graded crushed stone aggregate) as in 75mm thick flooring finished surfaces even and fair without using extra cement, complete all as specified and as directed
S&F mild steel pipe, beam section etc fixed with base plates, necessary nuts, bolts, plate etc as in posts Complete all as specified and directed
S&F structural steel work as roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat section ) incl distance pieces, cleats etc conforming to grade Fe 410-0 or 310-0 Complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ridges etc, fixed with self tapping screws Complete all as specified and directed
M&L for preparation of new or previously untreated surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide Complete all as specified and directed
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and colour pigment, complete all as specified and directed
M&L for Sand filling under floors or in foundations including watering and consolidation in layers, complete all as specified and directed
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .