| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-Finance 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | L1 | Accepted-Finance Admitted Found Reasonable for Acceptance | |
| 2 | L2₹34.7 L+₹2.4 L (7.42%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Rejected L1 being accepted | |
| 3 | L3₹35.1 L+₹2.9 L (8.89%)Rejected-Finance 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L3 | Rejected-Finance Rejected L1 being accepted | |
| 4 | L4₹38.4 L+₹6.1 L (18.9%)Rejected-Finance 2ND FLOOR PAPPOOTTY COMPLEX VAZHAKULAM MUVATTUPUZHA KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L4 | Rejected-Finance Rejected L1 being accepted |
Tender Value
₹35.6 L
EMD Value
₹71,240
Closing Date
4 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2022_MES_549816_1
GE (ARMY) TVM 9479/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹71,240
Yes
31 Oct 2022
3 Sept 2022
11 Oct 2022
5 Sept 2022
4 Oct 2022
20 Sept 2022
Amount
Supply, Installation, testing & commissioning of silent/containerised diesel engine driven generating set complete to give an output of 320 KVA, at 415 volts, 50 Hz, 3 phase, 4 wire supply with power factor 0.8 (Lagging), 1500 rpm, engine and alternator as per standered IS complete with relay panel and switch gears for automatic starting on main failure, mounted on common base plate, anti vibration rubber mounting pad complete in all respect with and including accessories and components as specified below including supply & fixing aesthetically designed weather and sound proof acqoustic enclosure with insulation conforming class for flammability for 320 KVA Generator sets ECO friendly and as per Ministery of Environment, forests notification 17 May 2002 complete including, Graphical LCD display, Microprocessor based Controller, Integrable with AMF, synchronization & communication configurations, emergency stop button, illumination inside canopy.
Meeting Emission and noise compliaint CPCB developing 400 Bhp, closed coupled with KOEL Green make 320 KVA (256 KW) 3 Phase, 415V, 1500 RPM, Micro Processor based engine controller with remote monitoring facility., Std. Control Panel with 3 Pole MCCB, 500 Amps (Adjustable Type) with Auto Start/Stop panel with battery charger Base Frame, Fuel Tank, Battery with leads and other accessories with type approved intergral KOEL GREEN Canopy as a complete set. Including First fill of lub oil and engine safeties- LLOP, HWT alongwith KOEL, complete including taking down old DG set from the location and depositing to MES store yard as directed. Make: Kirloskar Model No : KGI-320 WS DG Set with KOEL make engine model No DV8TAG1 (Meeting Emission & Noise compliant CPCB-II). or Equivalent as per make listed under P S Clause as approved by GE.
Supply, Installation, testing and commissioning of Auto Main Failure Panel suitable for 320 KVA Gen Set complete all as specified and directed
Supply and fix 500 Amp On load Changeover Switch complete all as specified and directed.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard/dense soil and in road cutting all as specified and as directed
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in hard/dense soil all as specified and directed NOTE: Reddled earth upto 20cm depth around cable for protection to be filled including spreading, levelling etc & punned down
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point
Supply and laying unreinforced precast concrete cable cover class LV type 1, flat, size 250x150x40mm complete all as specified and directed by Engr-in Charge
Supply, Laying & testing of XLPE insulated screened PVC bedded steel wire /strip armoured heavy duty (Electric power cable), 1100 Volt grade, multistranded aluminium conductor cable n.exc 100mtr, stacking laid into trench, passing through pipe, ducts, making electrical connection over pole/panel at one end and into the MCB DB's/Main switch/Change over switch through proper lugs/thimbles at the another end, having 240 sqmm, 3½ core nominal cross sectional area complete all as specified and directed
M&L for Earthing complete in replacement with copper earth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to glavanised earth lead of copper strip of size 20mm x 3mm by means of GI Bolts, Nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia from earth plate to Panel and DG set and water pipe 20mm dia GI medium grade raised upto a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with two handles, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance not of MES Schedule Part-I of SSR-2009 exceeding 50 mtr testing complete all as shown in electrical plate No-3 complete all as specified and directed. NOTE: (a) Earthing shall be provided as per IS:3043-1987. (b) Earthing shall be carried out 7.5 mtr apart from the building. (c) Rate for copper strip upto test point included in the quoted rate.
Shree Ayyappa Engineering
MONA GENERATOR SEVICES PVT. LTD.
Linsta Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .