Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC 17 1305 ARIAKATTU PALLURUTHY KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹34.4 L+₹1.0 L (3.06%)Rejected-Finance 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.6 L+₹2.2 L (6.48%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.7 L+₹5.3 L (15.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹48.7 L+₹15.3 L (45.8%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2023_MES_621753_1
8293_GE_NW
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹90,000
Yes
15 Feb 2024
5 Oct 2023
2 Nov 2023
5 Oct 2023
31 Oct 2023
19 Oct 2023
5 Oct 2023 - 24 Oct 2023
Amount
Taking down Copper/ aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light and making good the surface to match with existing surface complete all as specified and directed
M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade including PVC casing and capping and connected accessories ISI marked with concealed sunken boxes with modular cover plate, PVC boxes, hylam sheet, including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for one light point controlled by one switch complete all as specified and directed
All as per item No. 2 here-in-before but for one fan point controlled by one push button on independent board.
All as per item No. 2 here-in-before but for one bell point controlled by one push button on independent board.
All as per item No. 2 here-in-before but for 5 pin 5 Amps socket outlet point on independent board.
All as per item No. 2 here-in-before but for 5 pin 5 Amps socket outlet point on same board.
All as per item No. 2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed
M&L for point wiring for one light with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and directed
All as per item No. 8 here-in-before but for one fan point controlled by one push button on independent board.
All as per item No. 8 here in before but for one bell point controlled by one 5 Amp bell push on independent board.
All as per item No. 8 here in before but for one 5 pin 5 Amp socket outlet point on independent board.
All as per item No. 8 here in before but for one 5 pin 5 Amp socket outlet point on the same board.
All as per item No. 8 here in before but using with 2.5 Sqmm copper conductor cables multistranded (FRLSH) PVC insulated, unsheathed cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheathed cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board.
S&F in repair Bell push flush type 6A, 1module, complete all as specified and directed. Make:- Anchor Model No. 38091 or equivalent model of other manufacturers from the manufactures list.
S&F in repair electric bell, AC 230 Volt single pole complete all as specified and as directed. Make:- Cona Cat Part No. 9486 or equivalent model of other manufacturers from the manufactures list.
S&F in repair switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed. Make:- Anchor Model 38069 or equivalent model of other manufacturers from the manufactures list.
S&F in repair switch piano flush type single pole one way 15 Amp complete all as specified and as directed . Make:- Anchor Model 39989 or equivalent model of other manufacturers from the manufactures list.
S&F in repair switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified and as directed. Make:- Anchor Model 38841 or equivalent model of other manufacturers from the manufactures list.
S&F in repair socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed. Make:- Anchor Model 39993 or equivalent model of other manufacturers from the manufactures list.
S&F in repair fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed. Make:- Anchor Model 38284 or equivalent model of other manufacturers from the manufactures list.
S&F in repair ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed. Make:- Anchor Model 39040 or equivalent model of other manufacturers from the manufactures list.
S&F in replacement bell push flush type 5 Amps single pole complete all as specified and as directed. Make:- Anchor Model 38091 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs electric bell, AC 230 Volt single pole complete all as specified and as directed. Make:- Cona Cat Part No. 9486 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed. Make:- Anchor Model 38069 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, switch piano flush type single pole one way 15 Amp complete all as specified and as directed. Make:- Anchor Model 39989 or equivalent model of other manufacturers from the manufactures list.
S&F in replacement, socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed. Make:- Anchor Model 38364 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed. Make:- Anchor Model 39993 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, switch socket combination 5 Amps, 5 pin 2 in 1, complete all as specified and as directed. Make:- Anchor Model 38841 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, switch socket combination multipurpose 5 &15 Amps, 5 pin, 2 in 1 complete all as specified and directed. Make:- Anchor Model 39593 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed. Make:- Anchor Model 38284 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, capacitor for ceiling fans, 230 volts, 2.5 MFD including necessary soldering complete all as specified and as directed. Make:- Havells Cat Part No. QHPCWC5002X2 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, capacitor for any type of exhaust fan/ pedestal fan/ air circulator fan 230 volts AC including necessary soldering of capacity 4 MFD complete all as specified and directed. Make:- Havells Cat Part No. QHPCWC5004X0 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings, all as specified and directed. Make:- Anchor Model 39797 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, Ceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed. Make:- Anchor Model 39040 or equivalent model of other manufacturers from the manufactures list.
M&L in replacement sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper/ Emulsions matching to the existing colour/ quality of walls/ floors/ ceiling etc. complete all as specified and directed. Note- Five run of cable and one run of PVC casing and capping shall be measured as one unit.
All as per item No. 35 here-in-before but 2 runs of 4 sqmm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing complete all as specified and directed. Note- Three run of cable and one run of PVC casing and capping shall be measured as one unit.
All as per item No. 35 here-in-before but 2 runs of 6 sqmm single core FRLSH copper conductor and 1 run of 6 sqmm conductor for earthing complete all as specified and directed. Note- Three run of cable and one run of PVC casing and capping shall be measured as one unit.
M&L in replacement sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC conduits and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper/ Emulsions matching to the existing colour/ quality of walls/ floors/ ceiling complete all as specified and directed. Note- Five run of cable and one run of PVC conduits shall be measured as one unit.
All as per item No. 38 here-in-before but 4 runs of 16 sqmm single core FRLSH copper conductor and 1 run of 16 sqmm conductor for earthing complete all as specified and directed. Note- Five run of cable and one run of PVC conduits shall be measured as one unit.
All as per item No. 38 here-in-before but 2 runs of 4 sqmm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing. Note- Three run of cable and one run of PVC conduits shall be measured as one unit.
All as per item No. 38 here-in-before but 2 runs of 6 sqmm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing complete all as specified and directed. Note- Three run of cable and one run of PVC conduits shall be measured as one unit.
S&F in repairs, Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed. Make:- Legrand Cat Part No. 5076 70 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.. Make:- Legrand Cat Part No. 5076 72 or equivalent model of other manufacturers from the manufactures list. '
S&F in repairs, Sheet Metal Enclosure for MCB DB, TPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed. Make:- Legrand Cat Part No. 5076 73 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.. Make Legrand Cat Part No. 5076 10 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed. Make- Legrand Cat Part No. 5076 11 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, Sheet Metal Enclosure for MCB DB, SPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed. Make:- Legrand Cat Part No. 5076 12 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, MCB TPN 63 Amps, 415 Volt, complete all as specified and directed. Make:- Legrand Cat Part No. 4086 83 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, MCB TPN 32 Amps, 415 Volt, complete all as specified and directed. Make:- Legrand Cat Part No. 4086 80 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, MCB SPN 63 Amps, 415 Volt, complete all as specified and directed. Make:- Legrand Cat Part No. 4086 20 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, MCB SPN 6 to 32 Amps, 415 Volt, complete all as specified and directed. Make:- Legrand Cat Part No. 4086 17 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs, MCB SP 6 to 32 Amps, 415 Volt, complete all as specified and directed. Make:- Legrand Cat Part No. 4085 87 to 4085 95 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED glass T8 tube 20 Watt, 220 Volt, 50Hz, LED tube rod, double side connection, inbuilt driver, complete all as specified. Make:- CAT Part No. CRYSTALT81213SSTL20WLED865SGLASS ( Tube) of Havells or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED light fitting 20 W, high performance batten, 220 volt, 50 Hz, 6000 k surface mounted high quality extruded polycarbonate, environmental friendly, energy efficient, with all connecting accessories, with suitable connection complete all as specified and directed. Make:- Crompton, Cat Part No. CCS-100-20-65-HL2-DP-NWH or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED light fitting 10 W, high performance batten, 220 volt, 50Hz, surface mounted high quality aluminium extruded with all connecting accessories, with suitable connection complete all as specified and directed. Make:- Crompton, Cat Part No. LDL-10-CDL or equivalent model of other manufacturers from the manufactures list.
S&F in repairs ceiling light driver up to 5 Watt with all accessories and connection to the electric circuit complete all as specified and directed. Make:- Crompton, Cat Part No. SRPS-5K-440 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs ceiling light driver 10 Watt with all accessories and connection to the electric circuit complete all as specified. Make:- Crompton, Cat Part No. SRPSQ-10KV/5KA-440 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs ceiling light driver 20 Watt with all accessories and connection to the electric circuit complete all as specified. Make:- Crompton, Cat Part No. S0DVES-24-700-20W or equivalent model of other manufacturers from the manufactures list.
S&F in repairs 15 Watt Square recessed mounted down lighter with high luminous LED for indoor application, 230 Volt, 50Hz, min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified. Make: Crompton, Cat Part No. LSDEP-15-CDL or equivalent model of other manufacturers from the manufactures list.
S&F in replacement 12 Watt Square recessed mounted down lighter with high luminous LED for indoor application, 230 Volt, 50Hz, min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified. Make:- Crompton, Cat Part No. LSDEP-12-CDL or equivalent model of other manufacturers from the manufactures list.
S&F in repairs 15 Watt recessed round down lighter with high luminous LED for indoor application, 230 Volt, 50Hz, min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified. Make:- Crompton, Cat Part No. LCDEP-15-CDL or equivalent model of other manufacturers from the manufactures list.
S&F in repairs 12 Watt recessed round down lighter with high luminous LED for indoor application, 230 Volt, 50Hz, min 100 lm/ watt with all accessories and connection to the electric circuit complete all as specified. Make:- Crompton, Cat Part No. LCDEP-12-CDL or equivalent model of other manufacturers from the manufactures list.
S&F in replacement dimmable cob light 12 Watt, 50Hz, 230 Volt with all accessories and connection to the electric circuit complete all as specified. Make:- Luker, Cat Part No. LCOBD12 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs Ceiling light in Dome series 18 watt, round, 50Hz, 230 Volt with all accessories and connection to the electric circuit complete all as specified. Make:- Luker, Cat Part No. LCL18R or equivalent model of other manufacturers from the manufactures list.
S&F in repairs indoor wall mounted light 12 watt, 140 Volt to 265 Volt, IP-20, 50 Hz, aluminium housing with all accessories and connection to the electric circuit complete all as specified and directed. Make:- Luker, Cat Part No. LWL105 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs mirror light 12 watt 50 Hz, 230 volts with all accessories and connection to the electric circuit complete all as specified. Make:- Luker, Cat Part No. LMCL12 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 2' long, suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 3' long, suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 5' long, suitable for ceiling fans any type, any make, any size all as directed.
S& F replacement copper conductor multistranded cable flexible 03 core PVC insulated of size 40/ 0.076 at site/ MES store yard complete all as specified and directed.
S&F in repairs Fan canopy with tightening screw/ check nut, made out of PVC, suitable for ceiling fans any type, any make, any size all as directed.
S&F in repairs Rubber reel insulator, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
M&L in replacement for hanging hook square/ round shape for ceiling fan with nuts bolts and washer min thickness 5 mm complete all as specified and directed.
Taking down unserviceable ceiling fan of 1200mm/ 1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking/ heating up the motor to achieve the proper insulation resistance and re-hanging/ refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No. complete all as specified.
All as per item No. 75 here-in-before but exhaust fan of 450/ 300/ 250 mm sweep.
All as per item No. 75 here-in-before but wall mounted fan of 400/ 450 mm sweep.
All as per item No. 75 here-in-before but pedestal fans 600/ 400 mm sweep.
All as per item No. 75 here-in-before but industrial air circulator fans of any sizes.
M&L in replacement earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit, RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c, 20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc. including testing on completion complete all as specified and directed. Note- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
M&L in replacement earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete including provision of necessary excavation and earth work in any type of soil, PCC pit, RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c, 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc. including testing on completion complete all as specified and directed. Note- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S&F in repairs Modular Bell push 6A, 1module, complete all as specified and directed. Make Cona Model 9261 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs Fan Regulator, modular electronic rotary, 0-4 steps step type 100Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed. Make Cona Model 9376 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs switch modular 6 Amps 240 Volts one way switch complete all as specified and directed. Make Cona Model 9251 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified and directed. Make Cona Model 9316 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs Socket 6A/ 16 Amps 2/3 pin combined AC 240 Volt modular type complete all as specified and directed. Make Cona Model 9416 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs Switch modular type AC 240 volts 16 Amps one way complete all as specified and directed. Make Cona Model 9386 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs sunken box with Modular white cover plate 2 module with removing old type sunken boxes/ wooden board and match with existing surfaces, complete all as specified and directed
S&F in repairs sunken box with Modular white cover plate 3 module with removing old type sunken boxes/ wooden board and match with existing surfaces, complete all as specified and directed
S&F in repairs sunken box with Modular white cover plate 4 module with removing old type sunken boxes/ wooden board and match with existing surfaces, complete all as specified and directed
S&F in repairs sunken box with Modular white cover plate 6 module with removing old type sunken boxes/ wooden board and match with existing surfaces, complete all as specified.
S&F in repairs SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed. Make:- Indoasian Cat Part No 811956 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified. Make:- IndoAsian Cat Part No. 811957 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 32 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed. Make:-Indo Asian Cat Part No. 811958 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 63 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified and directed
S&F in repairs XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm 2 core including taking down old unserviceable cable complete all as specified and directed
S&F in repairs XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 core including taking down old unserviceable cable complete all as specified and directed
S&F in repairs XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core including taking down old unserviceable cable complete all as specified and directed
S&F in repairs circular high bay LED light 80 Watt, 240 volt, min lumens 110 Lm/w, IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make:- Crompton, Cat Part No. LHB11-80-CDL/60-M or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED circular Flood Light 30 Watt, 50 Hz, 220 Volt having IP-66 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified. Make:- Luker, Cat Part No. LFLR30 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED Flood Light 50 Watt, 50 Hz, 220 Volt having IP-66 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed. Make- Luker, Cat Part No. LFLR50 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED building security light 45 watts, 50 Hz, 220 Volt having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed. Make:- Havells, Cat Part No. ENDURASUNDOWNSL40WLED 765PASYBOPC or equivalent model of other manufacturers from the manufactures list.
S&F in repairs LED building security light 60 watts, 50 Hz, 220 Volt having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified and directed Make:- Havells, Cat Part No. ENDURASUNDOWNSL60WLED765 PASYBOTG or equivalent model of other manufacturers from the manufactures list.
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at 'E' area at Naval Base during off hours (1700 hrs evening to 0900 Hrs morning ) on all working days all as specified and directed by Engineer-in-Charge. (Refer Notes)
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc. carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at 'E' area at Naval base during off days including Sunday and holidays all as specified and directed by Engineer-in-Charge. (Refer Notes)
NOTE for item no. 104 & 105:- (i) The material and labour cost required for taking down existing fitting / fixture and fixing of new item shall be measured and paid separately under relevant item. Additional labour charge required for immediate attendance of complaint only shall be quoted under this item. (ii)The technician employed by the contractor shall available on all working days. The quoted rate shall inclusive of all labour, transportation of material and tools. (iii) The contractor shall display contact number of technicians in 'E' area at Naval Base to register users complaint. (iv) A penal recovery of Rs. 800/hour/complaint shall be effected on contractor beyond 3 hrs. A register shall be maintained by contractor duly countersigned by Concerned JE & AGE with time of occurrence of defect and time of rectification and submitted for claiming payment.. (v) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly including all aspects like labours ,tool, transportation etc.
M&L for checking of ceiling fan stability / tightness with fan hook for complete 'E' area of Naval Base as directed and make good, re-tightening of split pin / nut, bolt etc., ,loose connection in distribution boards, MCBs all as per site requirement complete all as specified and directed. Note:- (i) The cost of accessories like split pin, nuts, bolts, washers etc. if any required shall be included in the quoted rate. The quoted rate shall inclusive of all labour and plants like ladder etc. complete. (ii) The contractor shall maintain a register showing the location of fan duly signed by the users for the service carried out. This register shall be produced while claiming payment. (iii) The checking of fans shall be carried out once in 6 months. (iv) Checking of 7 fans and 2 DBs of any type at a time is shall be considered as one job.
M&L in replacement aluminium strip 25x3.15 mm with porcelain insulators, saddles and fixing screws etc. for roof conductor and down conductor above ground complete all as specified and directed
M&L in replacement air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed
M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws and taking down old ones complete all as specified and directed
M&L for Checking of earthing resistance and E-N voltage with calibrated earth tester meter and multimeter including recharging of conventional earthing of lightening arrestor of building /workshop/hanger /OTM etc. at 'E' area Naval Base Kochi complete with chemical, maintaining the earth testing record, rectification of earthing related fault complete all as specified and directed. Note:- A record for checking and recharging shall be maintained duly signed by user and JE E/M and verified by Engineer in charge. .
M&L in repairs galvanised steel strip 32mmx6mm complete with, protection sleeves, saddles, separator and fixing screws at surrounding inside and outside the bldg. complete all as specified and directed
M&L in repairs galvanised steel strip 25mmx4mm complete with, protection sleeves, saddles, separator and fixing screws at surrounding inside and outside the bldg. complete all as specified and directed
S&F Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 1x20 watt with glass & connector suitable for LED tube light with all accessories prewired, product in aluminium die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR Dhanbad & CCOE (PESO) Nagpur along with ISI marking including testing complete all as specified and directed including taking down of existing fitting. Make:- Crompton, Cat Part No. EXTN1LT8-16/20 or equivalent model of other manufacturers from the manufactures list.
S&F Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 2x20 Watt with glass & connector suitable for LED tube light with all accessories prewired, product in aluminium die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR Dhanbad & CCOE (PESO) Nagpur along with ISI marking including testing complete all as specified and directed including taking down of existing fitting. Make:- Crompton, Cat Part No. EXTN2LT8-16/20 or equivalent model of other manufacturers from the manufactures list.
S&F FLP rotary switch single pole 16 Amps and fixing arrangement including taking down of existing FLP switch complete all as specified and directed. Make:- Sudhir, Cat Part No. RI/OA/1010-2A or equivalent model of other manufacturers from the manufactures list.
S&F in repairs 4mm dia galvanised iron or steel wire buried in ground fixed on walls and connected to main earth strip including excavation and earth work, refilling etc. compete all as specified and as directed.
S&F in repairs rigid non metallic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends, fixing accessories such as couplers, lock Nuts, saddle pipe hook etc. for 25 mm dia ISI Marked. complete all as specified and directed
S&F in repairs recess mounted/ surface mounted commercial luminaire 36 watt, 50 Hz, 220 volts, 5700 K LED down lighter 2'x2', complete all as specified and directed. Make:- Havells, Cat Part No. VENUSNEOHE2X2R36WLED857PIRSENSOR or equivalent model of other manufacturers from the manufactures list.
S&F in repairs SS enclosure suitable for MCCB 100-200 amp complete all as specified and directed. Make:- Legrand Cat Part No. 5078 06 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs MCCBs FP 100 Amps thermal magnetic 25 KA complete all as specified and directed. Make:- Legrand Cat Part No. 4200 55 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs MCCBs FP 160 Amps thermal magnetic 25 KA complete all as specified and directed Make:- Legrand Cat Part No. 4200 57 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs MCCBs FP 200 Amps thermal magnetic 25 kA complete all as specified and directed, Make:- Legrand Cat Part No. 4202 18 or equivalent model of other manufacturers from the manufactures list.
S&F in repairs energy efficient ceiling fan BLDC of 1200mm sweep (5 star rated) 230 Volt, 50 Hz including all electrical connection all as specified and as directed and taking down old one and deposited with MES store yard. Make : Havells Cat Part No. Efficiencia Neo (BLDC 26W) or equivalent model of other manufacturers from the manufactures list. Note:- Old Ceiling fans shall be deposited to AGE E/M (NW) store yard
S&F in repairs exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed. Make:- Havells Cat Part No. Turbo Force SP or equivalent model of other manufacturers from the manufactures list. Note:- Old Exhaust fans shall be deposited to AGE E/M (NW) store yard.
S&F in repairs exhaust fan heavy duty with louvers complete of sweep size 450mm, 900 RPM, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified. Make:- Havells Cat Part No. Turbo Force SP or equivalent model of other manufacturers from the manufactures list. Note : Old Exhaust fans shall be deposited to AGE E/M (NW) store yard
S&F exhaust fan heavy made of PVC body complete with louvers shutter, 230 Volt, 50Hz, 1200 RPM copper winding of sweep size 250mm, single phase, with bolts, nuts and washers of suitable size embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed. Make : Havells Cat Part No. Ventil Air-DX white or equivalent model of other manufacturers from the manufactures list. Note : Old Exhaust fans shall be deposited to AGE E/M (NW) store yard
S&F in repairs PVC body exhaust fan motor suitable for 250/300 mm of any make as per site requirement complete all as specified and directed
S&F in repairs exhaust fan motor suitable for metallic body exhaust fan of any make as per site requirement complete all as specified and directed
Supply & fix PVC body wall fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed Make : Havells Cat Part No. Girik or equivalent model of other manufacturers from the manufactures list. Note : Old Wall fans shall be deposited to AGE E/M (NW) store yard
S&F in repairs Suspended LED lighting solution with 52 mm width and 75 mm height 24 watt 230V,50 Hz, including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make:- Crompton, Cat Part No. CCP-121-24-40-SL-NWH or equivalent model of other manufacturers from the manufactures list.
WELTRONENGINEERINGSERVICES
ANIE JOHN CONTRACTORS
K A ANTONY & SONS
MS BUILDERS
Jack Electrolinks Private Limited
St George Engineering Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .