Tender Value
₹13.3 L
EMD Value
₹26,700
Closing Date
19 Aug 2020, 6:00 pmClosed
AGM(E-E)- III, AAI, SVPI Airport, Ahmedabad.382475
AGM(E-E)- III, AAI, SVPI Airport, Ahmedabad.382475
Servicing Testing and Calibration of Breakers Relays Transformers and other Electrical Works for T 1 Power House and Other Areas at SVPI Airport Ahmedabad Year 2020 21
2020_AAI_54038_1
AAI/AH/ELECT/AGME3/eNIT2/20-21
Open Tender
Electrical Works
Item Rate
120 days
SVPI Airport, AAI, Ahmedabad
As per NIT
13 documents required · 13 mandatory
₹1,180
Yes
Airports Authority of India
₹26,700
Yes
25 Sept 2020
7 Aug 2020
25 Aug 2020
8 Aug 2020
19 Aug 2020
8 Aug 2020
8 Aug 2020 - 14 Aug 2020
Amount
Servicing, Testing and checking of Breakers Servicing, Checking and testing of 3 Ph 11KV 800A HT Vacuum Circuit Breaker (VCB) including testing of wiring of breaker and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of OEM/agency approved by Engineer-In-Charge) followed with submission of test report to AAI.
Servicing, Testing and checking of Breakers Servicing, Checking and Testing of the LT air circuit breakers up to 3200 Amp rating including testing of wiring of breaker and minor repairing works complete as required including documenting the testing as per recommended standards (through authorised agency of OEM/agency approved by Engineer-In-Charge) followed with submission of test report to AAI.
Servicing, Testing and Calibration of the following relays as per recommended standard and submission of calibration report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. a) IDMT relays for 11 KV Panel/ AMF Panel/ LT Panel (Set of 2 over current plus 1 earth fault).
Servicing, Testing and Calibration of the following relays as per recommended standard and submission of calibration report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. b) Auxiliary and Tripping relays including (Type: VAA / VAG).
Servicing, Testing and Calibration of the following relays as per recommended standard and submission of calibration report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. c) CTs in 11 KV HT and LT panel (set of 3 CTs, - RYB).
Servicing, Testing and Calibration of the following relays as per recommended standard and submission of calibration report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. d) PT, 3 phase, 11 KV Voltage Transformers.
Servicing and Testing of the following Transformer of 11 KV/ 430 V including as per recommended standard and submission of report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. Testing should include Insulation Resistance test, Voltage Ratio & Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. a) 2000 KVA Transformer.
Servicing and Testing of the following Transformer of 11 KV/ 430 V including as per recommended standard and submission of report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. Testing should include Insulation Resistance test, Voltage Ratio & Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. b) 1500 KVA Transformer.
Servicing and Testing of the following Transformer of 11 KV/ 430 V including as per recommended standard and submission of report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. Testing should include Insulation Resistance test, Voltage Ratio & Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. c) 315 KVA Transformer.
Servicing and Testing of the following Transformer of 11 KV/ 430 V including as per recommended standard and submission of report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. Testing should include Insulation Resistance test, Voltage Ratio & Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. d) 630 KVA Transformer
Servicing and Testing of the following Transformer of 11 KV/ 430 V including as per recommended standard and submission of report complete as required through authorised service agency of OEM/ agency approved by engineer -in - charge. Testing should include Insulation Resistance test, Voltage Ratio & Tap Continuity test, Magnetic Balance Test, Vector Group Test, Accessories working etc. e) 400 KVA Transformer
Dehydration and filtration of transformer oil of Transformers of following capacity at different Sites and submission of BDV(before and after) & acidity Testing report for each equipment. a) 2000 KVA Transformer.
Dehydration and filtration of transformer oil of Transformers of following capacity at different Sites and submission of BDV(before and after) & acidity Testing report for each equipment. b) 1500 KVA Transformer.
Dehydration and filtration of transformer oil of Transformers of following capacity at different Sites and submission of BDV(before and after) & acidity Testing report for each equipment. c) 315 KVA Transformer.
Dehydration and filtration of transformer oil of Transformers of following capacity at different Sites and submission of BDV(before and after) & acidity Testing report for each equipment. d) 630 KVA Transformer
Dehydration and filtration of transformer oil of Transformers of following capacity at different Sites and submission of BDV(before and after) & acidity Testing report for each equipment. e) 400 KVA Transformer
Inspection, Cleaning, Servicing, Testing and overhauling of the following as per recommended standard i/c labour and tools & plant job includes supply and replacement of gear oil SAE-140 grade, testing and checking of System Raising & Lowing Mechanism, Winch, Trailing Cable, Wire Rope, motor etc. complete as required i/c submission of inspection report but excluding replacement of electrical fixtures like ballast, igniter, capacitor lamps etc. Job to be carried through authorised service agency of OEM/ agency approved by engineer -in - charge. a) 30 Mtrs Height Apron Flood Light Tower's
Inspection, Cleaning, Servicing, Testing and overhauling of the following as per recommended standard i/c labour and tools & plant job includes supply and replacement of gear oil SAE-140 grade, testing and checking of System Raising & Lowing Mechanism, Winch, Trailing Cable, Wire Rope, motor etc. complete as required i/c submission of inspection report but excluding replacement of electrical fixtures like ballast, igniter, capacitor lamps etc. Job to be carried through authorised service agency of OEM/ agency approved by engineer -in - charge. b) 20 Mtrs Height Apron Flood Light Tower's
Inspection, Cleaning, Servicing, Testing and overhauling of the following as per recommended standard i/c labour and tools & plant job includes supply and replacement of gear oil SAE-140 grade, testing and checking of System Raising & Lowing Mechanism, Winch, Trailing Cable, Wire Rope, motor etc. complete as required i/c submission of inspection report but excluding replacement of electrical fixtures like ballast, igniter, capacitor lamps etc. Job to be carried through authorised service agency of OEM/ agency approved by engineer -in - charge. c) 30 Mtrs Height National Flag Mast
Supply of battery 12V, 100AH Tubular battery suitable LED street lighting, Solar charging with buyback of old batteries.
Supply of battery 12V, 100AH SMF suitable for GenSet cranking with buyback of old batteries.
Supply of battery 12V having capacity 100AH, SMF - VRLA suitable for UPS use.
Supply of battery charger suitable for 100 AH 24 Volt( 2X12, two battery in series ) . AC in put 230-250 volt and DC out 24 Volt. Charger should have suitable fuse with indication of charge, full charge, main on etc.
Supply of semi-conductor: Fuse 125A, type VSB125 make GE size 00, 500V ac
Supply of Volt meter range 0-750 VAC Aux supply 230 VAC, Model type 96R350IAC
Supply of 800Amp sensor plug, make Schneider electric, suitable for breaker type NW08H1
Supply of 1000Amp sensor plug, make Schneider electric, suitable for breaker type NW10H1
Supply of MECO ‘C’ digital Amps meter or equivalent, 0-20 Amp AC, Model Type- 96R350IAC, Aux supply 220 VAC
Supply of 0-5 Amps meter ,AC, model R3501 AC Aux – 230 volt.
Supply of Contactor make GE type CL 10A 300M with 3NO & 3NC contact
Supply of Contactor C&S make Model Type LCI-D323 – AC 32A CTS
Supply of Capacitor CLMD 63 or equivalent, ABB make 120 KVAR switch
Supply of Capacitor 50 KVAR suitable for 440 volt APFC panel application
Supply of TNC switch Kaycee make 25A / 660V type (BCC02P016K17)
Supply of GE make spectronic ACB spares for 800amp to 1600amp. a) Pole Assembly
Supply of GE make spectronic ACB spares for 800amp to 1600amp. b) Cluster Contact
Supply of GE make spectronic ACB spares for 800amp to 1600amp. c) Closing Coil
Supply of GE make spectronic ACB spares for 800amp to 1600amp. d) Isolating Contact
Supply of GE make spectronic ACB spares for 800amp to 1600amp. e) Shunt Trip Coil
Supply of GE make spectronic ACB spares for 800amp to 1600amp. f) Spring Charging Motor
Supply of GE make spectronic ACB spares for 800amp to 1600amp. g) Moving Arcing
Supply of GE make spectronic ACB spares for 800amp to 1600amp. h) Fix Arcing
Supply of GE make spectronic ACB spares for 800amp to 1600amp. i) UDC Assembly
Supply of GE make spectronic ACB spares for 2500amp. a) Pole Assembly
Supply of GE make spectronic ACB spares for 2500amp. b) Cluster Contact
Supply of GE make spectronic ACB spares for 2500amp. c) Closing Coil
Supply of GE make spectronic ACB spares for 2500amp. d) Isolating Contact
Supply of GE make spectronic ACB spares for 2500amp. e) Shunt Trip Coil
Supply of GE make spectronic ACB spares for 2500amp. f) Front Fascia
Supply of GE make spectronic ACB spares for 2500amp. g) Mechanical Lock 30mm
Supply of 3200/5 Amps rectangular current transformer having rating of 15VA, with protection class:1.0 and window size of 7'' x 14" and overall dimension 13" x 20". (Note- All dimensions are in inch).
Supply of Thermoplastic (Polycarbonate) Box having ingress protection rating of IP65 or higher with provision of Plug & Socket rated for 63Amp, 5 pin (3P+N+E) for ingress protection rating of IP67 along with terminals of 16 sq mm - 12 Nos, having dimension of 360mm x 350mm x 309mm.
Supply of Insulated Coupler rated for 63 Amp, 415 Volt or higher having 5 pin comprises of 3Pole, one neutral and one earth with ingress protection rating of IP67 complete with all accessories as required.
Supply of Insulated Plug rated for 63 Amp, 415 Volt or higher having 5 pin comprises of 3Pole, one neutral and one earth with ingress protection rating of IP67 complete with all accessories as required.
To carry out the complete items of works of CPWD schedule of rates (Electrical) DSR-2018 as per CPWD specifications as required for an amount of Rs. 50000/-.
Adarsh electric works
System Protection
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .