Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹11.8 L+₹74,090 (6.72%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹14.1 L+₹3.1 L (27.8%)Rejected-AOC 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | Rejected-Technical | - | Rejected-Technical VERIFIED BUT NOT ENLISTED IN REQUISITE CATEGORY |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
14 Oct 2021, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
CERTAIN REPAIR/ REPLACEMENT OF AC, REFRIGERATION, WATER COOLER AND GEYSERS AT DEAL AND IRDE UNDER GE (I) R N D DEHRADUN
2021_MES_477164_1
GE(I)RND/9059/E8/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEHRADUN
Class E Category c (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹32,000
Yes
18 Nov 2021
23 Sept 2021
16 Oct 2021
23 Sept 2021
14 Oct 2021
30 Sept 2021
23 Sept 2021 - 30 Sept 2021
Amount
Disconnecting, dismantling and taking out the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, checking serviceability of wiring & parts, painting the bottom with one coat of black synthetic enameled paint, brazing, reassembling and testing of the AC complete, all as specified and directed by Engr-in-Charge.
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed by Engr-in-Charge.
Note: (Applicable for Sch ‘A’ Item No.1& 2). (i) Window/Split type AC's shall be taken from department on "as and where installed" basis. (ii) Window/Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1&2). (iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Window/Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (v) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only repaired compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 1.5 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new Rotory type compressor sealed unit of suitable capasity/ model in the unit properly for 2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for window type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for Window type AC 1.5 ton/2.0 ton capacity 1/5 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge.
Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge.
Supply only cooling coil unit for window type AC of any type/ any capacity complet, all as specified and directed by Engr-in-charge.
M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).
M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 V AC for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed by Engr-in-charge.. (Make : Universal/Sarda )
M&L for replacement of unserviceable running capacitor 36/45/50 MFD 230 V for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed by Engr-in-charge.. (Make : Universal/Sarda )
M&L for replacement of unserviceable overload protection coil (1622) 230 Volts for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable Relay (1622) suitable for window/Split type AC 1.5 Ton/2.0 Ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable thermostat suitable for window type Ac 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge. (Make : Indofoss or equivalent as approved).
M&L for replacement of unserviceable capillary tube and stainer for window/Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable operation knob fro window type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable PVC air filter for window type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable PVC air filter for Split type AC of 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable capacitor for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable fan blade for blower motor suitable for window /Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable swinging motor with louvers as per existing make for Split type AC 1.5 ton/2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .(Make : Carrier/Hitachi/LG )
M&L for replacement of unserviceable LCD / LED display unit for Window/split type AC 1.5 / 2.0 ton capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed by Engr-in-charge.
M&L for replacement unserviceable wiring for AC window type /split type 1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete, all as specified and directed by Engr-in-charge.
Supply and fixing in replacing refrigerant copper tubing 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply and fixing in replacment foam type insulation sleeve for copper tubing 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable reverse cycle valve in window/Split type AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed. Make : Renutrol/Pacific
M&L for replacement of unserviceable PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed by Engr-in-charge. (Make : KDK/Nicco/Finolex/Havells)
M&L for replacement of unserviceablePVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed by Engr-in-charge. (Make : KDK/Nicco/Finolex/Havells)
M&L for dismantling of storage type water cooler of 40/80/150 ltrs capacity of existing model in various location, shifting to MES Yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and sticking a sticker mentioning the “No, Date of overhauling, Due date, CA No., Contractor’s name, user’s signature’ reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts ( ie compressor, blower motor) measured & paid separately as supply only rates. Rates for fixing of spares parts under the unit rate quoted by the contractor for this item.
Supply only new compressor sealed unit of 40/80 ltrs capacity of existing model in the unit properly for storage type water cooler of any type complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only new compressor sealed unit of 150 ltrs capacity of existing model in the unit properly for storage type water cooler of any type complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )
Supply only blower motor including fan blade, capacitor complete suitable for 40/80 ltrs capacity, 220 volts, single phase complete, all as specified and directed by Engr-in-charge.
Supply only blower motor including fan blade, capacitor complete suitable for 150 ltrs capacity, 220 volts, single phase all as specified and directed by Engr-in-charge.
Supply only new condensing coil unit suitable for 40/80 ltrs capacity, 220 volts, single phase complete, all as specified and directed by Engr-in-charge.
Supply only new condensing coil unit suitable for 150 ltrs capacity, 220 volts, single phase complete, all as specified and directed by Engr-in-charge.
M&L for charging refrigerant gas in the system of water cooler of any capacity complete, all as directed by Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as supply only).
M&L for replacement of unserviceable capillary tube and stainer for storage type water cooler of 40/60/150 ltrs capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable overload protection coil 230 volts for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable relay suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed by Engr-in-charge. ( Make : Indfoss / Usha / Arvind)
M&L for replacement of unserviceable thermostat suitable for water cooler of 40/60/150 ltrs capacity icomplete, all as specified and directed by Engr-in-charge. (Make : Indfoss/Asian).
M&L for replacement of unserviceable starting capacitor 80/100 MFD 230 Volts AC for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed by Engr-in-charge. (Make : Indfoss/Sarda )
M&L for replacement of unserviceable starting capacitor 1.5/2.0 MFD 230 Volts AC for spilt AC 1.5 Ton/2.0Ton capacity indoor fan blower motor complete, all as specified and directed by Engr-in-charge. (Make : Universal/Sarda )
M&L for replacement of unserviceable running capacitor suitable for water cooler of capacity 40/60/150 ltrs complete, all as specified and directed by Engr-in-charge. (Make : Indfoss/Sarda).
M&L for replacement of unserviceable fan blade for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable capacitor for blower motor suitable for water cooler of 40/60/150 ltrs capacity complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable internal wiring of AC, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable incl testing checking etc complete.
M&L for replacement of head cover gasket for water cooler of 40/60/150 ltrs capacitycomplete, all as specified and directed by Engr-in-charge.
M&L for dismantling of storage type refrigerator/freezers of 165/212/310 ltrs capacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet with new one) by spraying enamel paint and eassembling, testing, checking and shifted to existing location including masonry work all as directed & specified by Engineer-in-Charge. (NOTE: The spare parts ( ie compressor, cooling unit ) measured and paid separately as supply only rate. Rates for fixing of spare parts under the unit rate quoted by the contractor for this item.
Supply only Thermostat bellow type with setting range 00°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply only Thermostat cut out bellow type with setting range 00°C to 100°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply only new compressor seal unit of 165/212 ltrs capacity of existing model in the unit properly for domestic refrigerator/freezers of any type all as specified and directed by Engr-in-charge.
Supply only new compressor seal unit of 310 ltrs capacity of existing model in the unit properly for domestic refrigerator/freezers of any type all as specified and directed by Engr-in-charge.
Supply only freezer coil unit for domestic refrigerator of any type/ any capacity complet, all as specified and directed by Engr-in-charge.
M&L for charging refrigerant gas in the system of domestic refrigerator of any type/ any capacity complete, all as directed by Engr-in-charge. (Note : the refrigerant gas measured and paid separately under relevent items as applicable as supply only ).
M&L for replacement of unserviceable capillary tube and stainer for any type and capacity complete for domestic refrigerator/freezer,all as specified and directed by Engr-in-Charge.
M&L for replacement of unserviceable timer/bimetallic relay of existing type for domestic refrigerator/freezer, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable over load relay for domestic refrigerator/freezer of any type/ any capacity complete, all as specified ans directed by Engr-in-Charge.
M&L for replacement of unserviceable thermostat for domestic refrigerator/freezer of any type/any capacity complete, all as specified ans directed by Engr-in-Charge.
Supply only refrigerant gas R-22.
Supply only refrigerant gas 134A.
Supply only refrigerant gas R-407/R-410 (HYDRO CARBON)
M&L for replacement of angular valve of size 1/2" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
M&L for replacement of angular valve of size ¼" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
M&L for replacement of angular valve of size 5/8" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
M&L for replacement of angular valve of size 3/8" suitable for split type AC complete. all as specified & directed by Engineer-in-Charge
Supply only Remote control for split/ Window type AC of LG/Samsung/existing make of 1.5 TR/2 TR with battery complete,all as specified & directed by Engineer-in-Charge.
M & L for dismantling of unserviceable voltage stablizer of capacity 3 KVA/4 KVA/5 KVA in various location for repair/replacement of unserviceable parts, cleaning, servicing, checking, reassembling, testing and handed over to MES in serviceable condition all as specified and directed by Engr-in-Charge (Note :- The spare parts measured and paid separately as supply only rates. Rates for fixing of spare parts under relevant items shall be included in item)
Supply only transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 3/4/5 KVA of approved make complete all as specified and directed. .
Supply only relay 12/24 volts suitable for 3/4/5 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make complete all as specified and directed.
Supply only electromechanical type voltmeter 0 to 300 volts Single Phase , AC, 65 mm square/round for stabilizer as per requirement complete all as specified & directed. Make – AE or equivalent approved.
Supply only DC electronic circuit for relay of capacity 24/12 volts stabilizer for 3 to 5 KVA of approved make complete all as specified & directed.
Supply only 3 way connector 230 volts 50 Hz AC, 32 Amp of approved make & existing shape and size complete all as specified and directed.
Supply only toggle switch 20/30 Amp two way of approved make complete all as specified and directed.
Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item No.2 at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete. all as directed by Engineer-in-Charge.
Supply &Fixing in replacement of unserviceable Oudoor unit body complete with out compressor unit suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed by Engr-in-Charge.
Supply &Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity, all as specified and directed by Engr-in-Charge.
Supply &Fixing in replacement of unserviceable mild steel work as split type AC outdoor/water cooler wheel stand /supporting /protection cage etc. of suitable size of flat iron/Angle iron etc.,cut to shape, including bending and welding as necessary, etc.conforming to Fe.290.Gde-E-165, with and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete, all as specified and directed by Engr-in-charge.
M & L for preparation of the steel surfaces of desert cooler and applying one coat of synthetic enameled paint on all exterior surfaces and applying one coat of black bituminous paint on all interior surfaces including bottom surfaces and writing MES No of the desert cooler in the pattern as approved by the Engineer-in-Charge with different tint / colour complete all as specified and directed.
Supply &Fixing in replacement of unserviceable PVC distributor 3 way, suitable for 15mm dia water distribution complete all as specified and directed.
Supply &Fixing in replacement of unserviceable wood wool pads best quality of required size as approved (three in each on desert cooler) complete all as specified and directed.
Supply &Fixing in replacement of unserviceable Water circulating pump 1/ 70 H P capacity single phase 230 volts, 1340 RPM, 1.5 Mtr head suitable fot any make any capacity of Desert cooler Make : AUE / CG/ Kaithan
Supply &Fixing in replacement of unserviceable plug top 3 pin, 15/16 Amp capacity complete all as specified and directed. Make : Anchor (Penta deluxe) or equivalent as approved by GE.
Supply &Fixing in replacement of unserviceable Fan motor double speed 230 volts, 50 HZ 1/13 HP complete suiable for any make and any capacity of Desert cooler make Cool Home/AUE.
Supply &Fixing in replacement of unserviceable Capacitor suitable for any type any capacity of desert cooler fan motor complete
Supply &Fixing in replacement of unserviceable Regulator for any type any make of Desert cooler
Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any make and taking out the same in any position from the existing location.Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered including re-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing and checking of all the functioning of water inlet outlet valves connected with geysers.all as specified and directed by Engr-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately.
Disconnecting and taking down the existing Geyser of any description and any capacity (25 / 50 Ltrs) and any position from the existing location and Dismantling the Geyser of any capacity and of any description material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , base assembly etc. with brush, cleaning rod, and using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately
Supply only Rubber PVC gasket to ensure water tightness for 25/50 liters capacity complete, all as specified and as directed by Engr-in-charge.
Supply only MS base plate cup any type with screws of suitable size as per requirement complete, all as specified and as directed by Engr-in-charge.
Supply only Heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
Supply only Steel inner tank of 25 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified and as directed by Engr-in-charge.
Supply only Steel inner tank of 50 litre capacity geyser tank by made out of steel sheets appropriate thickness complete, all as specified and as directed by Engr-in-charge.
Supply only Insulating material (glass wool for Geyser) complete, all as specified and as directed by Engr-in-charge.
Supply only Thermostat with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply only Base assay complete with inlet, out let and pipes with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut, bolt and washers fsuitable for 25 Liters cap to 50 Liters cap complete, all as specified and as directed by Engr-in-charge.
Supply only Non return valve 15 mm dia cast copper alloy ISI mark complete, all as specified and as directed by Engr-in-charge.
Supply only Safety valve/Fusible plug 15mm complete, all as specified and as directed by Engr-in-charge.
Supply only Chromium plate copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete, all as specified and as directed by Engr-in-charge.
Supply only PVC connecting tube 450 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
M&L in replacement of unserviceable bottom plate of geysers 25/50 liters capacity, same sizes and shape complete all as specified & directed.
M&L in replacement of unserviceable air release valve 15 mm bore for geyser as per existing type complete all as specified and directed.
M&L in replacement of unserviceable Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed
M&L for Painting of geysers size 25/50 liter any make with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/rust and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2 mm width letter on geyser body with black enameled paint complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed.
Supply only assembly type round heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
Supply only PVC hot and cold connecting tube 600 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
Supply and fixing sheet metal box with MCB 20A and with 3 pin socket and top etc complete all as specified superior quality as approved by Engineer-in-charge.
Supply only Thermostat bellow type with setting range 00°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply only Thermostat cut out bellow type with setting range 00°C to 100°C suitable for 230 volts AC, electric supply complete all as specified and directed, Make – Recold / Bajaj,/ Daspass
Supply and fixing fastener of size 3" /4" fixing of geyser complete all as specified and directed.
Supply and fixing 'U' assembly coppper 9 hole for 25 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly coppper 9 hole for 50 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly coppper 6 hole for 25 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly coppper 9 hole for 50 ltr geyser complete all as specified and directed.
M&L for point wiring for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete. Make of cable and conduit: Havells/ Plaza/ Kalinga.
S&F Modular switch piano single pole one way 16 amp complete. Make - Legrand / Anchor Penta / Crabtree as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / Anchor Penta / Crabtree as approved.
MAHADEV ELECTRICALS
Dheer Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .