| Sl No | Description | Qty | Unit | S P thomas L2 | WILSON THOMAS L1 |
|---|---|---|---|---|---|
| 1.00Appendix A Pipe line extension of Palupuzha LIS | |||||
| 1.00 | 15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road | 34.8 | sqm | 360.93 ₹12,560.36 | 359.09 ₹12,496.33 |
| 1.00 | 2.10.1.2:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia | 460 | metre | 428.72 ₹2.0 L | 426.53 ₹2.0 L |
| 1.00 | OD31960/2023-2024:Fencing one side of trenches, 1.5 meter height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15 cm to 24cm) fixed at 2m intervals ( KW 8.1) Details cost for 10 m | 460 | metre | 22.51 ₹10,354.60 | 22.4 ₹10,304 |
| 1.00 | 18.31.3.1:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately):
150 mm diameterClass I | 3 | no | 6,870.28 ₹20,610.84 | 6,835.24 ₹20,505.72 |
| 1.00 | OD31966/2023-2024:Supplying and fixing 110mm PVC ball valve | 15 | each | 935.01 ₹14,025.15 | 930.24 ₹13,953.60 |
| 1.01 | 50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 | 350 | metre | 722.9 ₹2.5 L | 719.21 ₹2.5 L |
| 1.01 | OD31967/2023-2024:Providing and fixing 50mm dia double acting air valve including all accessories etc
complete as per CPWD specifications and direction of Engineers in charge at site. | 1 | each | 3,899.2 ₹3,899.20 | 3,879.31 ₹3,879.31 |
| 1.01 | 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 5.22 | cum | 7,990.85 ₹41,712.24 | 7,950.1 ₹41,499.52 |
| 1.01 | 50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend | 38 | no | 161.06 ₹6,120.28 | 160.24 ₹6,089.12 |
Tender Value
₹21.2 L
EMD Value
₹50,000
Closing Date
22 Apr 2025, 2:00 pmClosed
Executive Engineer
Minor Irrigation Division, 4th Floor,Civil Station, Kakkanad, Ernakulam
Pipe line extension work of LIS
2025_Irrig_760171_1
EE/MIDVN/EKM/01/ET/2025-26
Open Tender
Civil Works - Others
60 days
Parakkadavu
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
26 Dec 2025
15 Apr 2025
23 Apr 2025
15 Apr 2025
22 Apr 2025
15 Apr 2025
Amount
Appendix A Pipe line extension of Palupuzha LIS
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
2.10.1.2:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
OD31960/2023-2024:Fencing one side of trenches, 1.5 meter height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15 cm to 24cm) fixed at 2m intervals ( KW 8.1) Details cost for 10 m
18.31.3.1:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 150 mm diameterClass I
OD31966/2023-2024:Supplying and fixing 110mm PVC ball valve
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
OD31967/2023-2024:Providing and fixing 50mm dia double acting air valve including all accessories etc complete as per CPWD specifications and direction of Engineers in charge at site.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
OD26649/2024-2025:supplying and fixing 160 mm dia PVC bend including fitting charges, solvent cement etc complete.
OD26658/2024-2025: Supplying and fixing 200mmx160mm dia reducer (PVC) including fitting charges, labor etc complete as per the directions of departmental officers at site.
OD2141/2025-2026:Supplying and laying 160mm dia PVC pipes (6kg/cm2)and specials, solvent cement from the stacking places of work site, lowering in to trenches already made, placing in position aligning the pipe to lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure including hire charges for all tools testing equipments cost and conveyance of water etc complete.
Appendix B Pipe line extension of Daivathanpady LIS
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
2.10.1.2:Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
OD26644/2024-2025:Fencing one side of trenches, 1.5 meter height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15 cm to 24cm) fixed at 2m intervals ( KW 8.1) Details cost for 10 m
OD2145/2025-2026:Supplying and laying 160mm dia PVC pipes (6kg/cm2)and specials, solvent cement from the stacking places of work site, lowering in to trenches already made, placing in position aligning the pipe to lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure including hire charges for all tools testing equipments cost and conveyance of water etc complete.
OD26641/2024-2025: Supplying and fixing 160mmx110mm dia reducer (PVC) including fitting charges, labor etc complete as per the directions of departmental officers at site.
50.18.8.9.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
OD26642/2024-2025:Supplying and fixing 110mm PVC ball valve
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
OD27649/2024-2025:Supplying and fixing 160 mm dia tee (PVC) including fitting charges, solvent cement etc complete as per the directions of departmental officers at site.
OD27650/2024-2025:supplying and fixing 160 mm dia PVC bend including fitting charges, solvent cement etc complete.
18.31.3.2:Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately): 150 mm diameterClass II
S P thomas (BID ID -2200210)
Bidder Name
WILSON THOMAS
S P thomas
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1235702.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid