Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | ₹18.9 L Quoted ₹19.4 L | L1 | Accepted-AOC Accepted for acceptance being lowest. |
| 2 | L2₹20.9 LRejected-Finance | ₹20.9 L | L2 | Rejected-Finance Not L1. |
| 3 | L3₹24.8 LRejected-Finance NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | ₹24.8 L | L3 | Rejected-Finance Not L1. |
| 4 | L4₹24.9 LRejected-Finance | ₹24.9 L | L4 | Rejected-Finance Not L1. |
| 5 | L5₹25.9 LRejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹25.9 L | L5 | Rejected-Finance Not L1. |
| Sl No | Description | Qty | Unit | M/s Prakash Enterprises L1 | SURESH ELECTRICALS L5 | Sukhi Electricals L4 | M/s. Ambabhai K patel L3 | Pooja Enterprise L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point, socket point or power point including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed. | 597 | Point | 5 ₹2,985 | 15 ₹8,955 | 25 ₹14,925 | 50 ₹29,850 | 10 ₹5,970 |
| 2.00 | Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc complete all as specified and directed. | 16 | Each | 5 ₹80 | 150 ₹2,400 | 50 ₹800 | 20 ₹320 | 25 ₹400 |
| 3.00 | Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings, bulk head fittings, tube light fittings, street light, flood LED lights etc complete all as specified and directed. | 765 | Each | 10 ₹7,650 | 50 ₹38,250 | 25 ₹19,125 | 20 ₹15,300 | 10 ₹7,650 |
| 4.00M&L for point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for PVC type fitment including provision for fixing of PVC boxes of suitable size as per site reqmt complete alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 1.5sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. | ||||||||
| 4.10 | (a) One Light point / Fan point controlled by one switch | 100 | Point | 350 ₹35,000 | 750 ₹75,000 | 750 ₹75,000 | 650 ₹65,000 | 400 ₹40,000 |
| 4.20 | (b) One 3 pin socket outlet 5Amps on the same board with other switches | 40 | Point | 350 ₹14,000 | 450 ₹18,000 | 200 ₹8,000 | 150 ₹6,000 | 150 ₹6,000 |
| 4.30 | (c) One 3 pin 5 Amp socket out let controlled by one switch on independent board | 80 | Point | 350 ₹28,000 | 850 ₹68,000 | 750 ₹60,000 | 650 ₹52,000 | 400 ₹32,000 |
| 4.40 | (d) One bell /Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent | 20 | Point | 350 ₹7,000 | 650 ₹13,000 | 750 ₹15,000 | 650 ₹13,000 | 400 ₹8,000 |
| 4.50 | (e) One light point controlled by two 2-way switch with cable 1.5 sqmm | 12 | Point | 350 ₹4,200 | 650 ₹7,800 | 850 ₹10,200 | 850 ₹10,200 | 500 ₹6,000 |
| 5.00 | M&L for point wiring for power point with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for PVC type fitment including provision for fixing of PVC boxes of suitable size as per site requirement and thickness as per IS complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 2.5 sqmm as continous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper / white washing/colour washing to match with the existing surface complete all as specified and directed. | 30 | Point | 350 ₹10,500 | 950 ₹28,500 | 950 ₹28,500 | 750 ₹22,500 | 600 ₹18,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Sept 2025, 6:00 pmClosed
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
REPAIR / MAINT OF INTERNAL ELECTRIFICATION IN MAP AND BILLETS AREAS AT AF-I UNDER GE (AF) JAMNAGAR NO.2
2025_MES_724930_1
8597/E8
Open Tender
Electrical and Maintenance Works
270 days
Jamnagar
Please refer tender documents and NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹50,000
Yes
7 Feb 2026
7 Aug 2025
6 Sept 2025
7 Aug 2025
4 Sept 2025
21 Aug 2025
Amount
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point, socket point or power point including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed.
Taking down carefully by unscrewing from main switch boards/cut out boxes/MCB DBs / complete sealing the cable end and making good disturbed surface by walls etc complete all as specified and directed.
Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings, bulk head fittings, tube light fittings, street light, flood LED lights etc complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for PVC type fitment including provision for fixing of PVC boxes of suitable size as per site reqmt complete alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 1.5sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
(a) One Light point / Fan point controlled by one switch
(b) One 3 pin socket outlet 5Amps on the same board with other switches
(c) One 3 pin 5 Amp socket out let controlled by one switch on independent board
(d) One bell /Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent
(e) One light point controlled by two 2-way switch with cable 1.5 sqmm
M&L for point wiring for power point with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for PVC type fitment including provision for fixing of PVC boxes of suitable size as per site requirement and thickness as per IS complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 2.5 sqmm as continous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper / white washing/colour washing to match with the existing surface complete all as specified and directed.
All as per item No 5 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M & L for switch piano flush type single pole, one way 5 Amp 230 V complete all as specified and directed.
M & L for socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed.
M & L for switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and directed.
M & L for switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
Supply and fix in repair stepped type electronic fan refulator flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
M&L for ceiling rose, 2 to 3 terminal PVC/ polycarbonate, isolated body type suitable for AC 230volts complete all as specified and directed.
M & L for switch piano type 2 way 5 amp 230 volts complete all as specified and directed.
M & L for bell push 5 Amp 230 volts complete all as specified and directed.
M & L for bell AC 230 Volts, single pole complete all as specified and directed.
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 20 Amp MCB SP complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for modular type fitment of suitable size and thickness as per IS, complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 1.5sqmm as continous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
(a) One Light point /Fan point controlled by one switch
(b) One 3 pin socket outlet 5Amps on the same board with other switches
(c) One 3 pin 5 Amp socket out let controlled by one switch on independent board
(d) One bell / Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent
(e) One light point controlled by two 2-way switch with cable 1.5 sqmm
M&L for point wiring for power point with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for modular type fitment of suitable size and thickness as per IS complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 2.5 sqmm as continous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
All as per item No 18 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in existing concealed conduit with all accessories including providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet (HYLUM BRAND) top cover alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 1.5sqmm as continous earth wire connected to common earth and erth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or froof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
(a) One Light/Fan point controlled by one switch
(b) One 3 pin socket outlet 5Amps on the same board with other switches
(c) One 3 pin 5 Amp socket out let controlled by one 5 amp switch on independent board
(d) One bell /Buzzer point controlled by one bell push 5 amp
(e) One light point controlled by two 2-way switch with cable 1.5 sqmm
M&L for point wiring with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in existing concealed conduit with all accessories including providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet (HYLUM BRAND) top cover alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 2.5sqmm as continous earth wire connected to common earth and earth dolly complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or froof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M & L for module cover plate with frame as per site requirement for following module complete all as specified and directed.
(a) 1 module
(b) 2 module
(c) 3 module
(d) 4 module
(e) 6 module
(f) 8 module
M & L for Modular metal Flush box as per site requirement.
(a) 1/2 module
(b) 3 module
(c) 4 module
(d) 6/8 module
M & L for modular switch 1 way 6 Amp 1 module complete all as specified and directed.
M & L for modular switch 2 way 6A, 1 module complete all as specified and directed.
M & L for modular switch 1 way 16/20 Amp 1 module complete all as specified and directed.
M & L for modular socket 6A 2/3 Pin universal 2 module complete all as specified and directed.
M & L for modular socket 16A/ 6A 2/3 Pin combined 2 module complete all as specified and directed.
M & L for modular fan step regulator 100 watt 2 module complete all as specified and directed.
M & L for modular bell push 6A1 way, 1 module complete all as specified and directed.
Supply and fix in repair of lamp holder, white polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete all as specified and directed.
Supply and fix in repair of bell musical type AC 230 volts, as directed including connecting complete all as specified and directed.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 10 watt, channel housing & diffuser of length 600mm (approx) with all accessories, fixing arrangement internally pre-wired fixed in position & connecting complete all as specified and directed.
Supply and fix in repair LED 12 W Porch light along with necessary fixing arragement complete all as specified and directed.
Supply and fixing in repair recess mounted LED luminaire with full diffuser 36 watt of 2x2 grid for new age work space, powder coated luminaire with minimum 100lm/watt efficiency, 25000 to 50000 working hours and 6500CCT complete all as specified and directed.
S & F bulkhead fitting 10watt made die cast aluminium housing with complete assembly and PC opal diffuser suitable for surface/wall mounted dust and water resistant complete all as specified and directed.
Taking down carefully (copper / aluminium) submain wiring complete of any type (batten/surface conduit or concealed) for socket point or power point complete with all fittings such as swiches sockets pendants etc complete and making good distuebed surface of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed of the following sizes of cables:-
Using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 4sqmm copper cable & 1 run of 4.0sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit
Using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire Note :2runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
Using two single core PVC insulated FRLS cable 10 sqmm copper conductor multi stranded and 10.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 10sqmm copper cable & 1 run of 10 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit
Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43, single pole and neutral 250 Volts, flush to wall complete with IP 43 protection complete all as specified and directed.
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for for IP 43, single pole and neutral 250 Volts, flush to wall complete with IP 43 protection complete all as specified and directed.
M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for for IP 43, single pole and neutral 250 Volts, flush to wall complete with IP 43 protection complete all as specified and directed.
M&L for distribution board (DB), double door type as per IEC 61439-3 made out of sheet metal enclosure (CRCA Sheet) dust and vermin proof MCB DB, TPN 4 way with 250 Amps rated copper busbar, 415 Volts with in built MCCB 160 Amps, 10KA 01 No 2neutral bar and 2 earth bar IP 43 protection cable ties for cable management (fully insulated busbar and shrouded neutral bars) reversible door for IP 43 , flush mounting to wall, including provision of MCB SP 6 to 32 amp 10KA 12 nos complete all as specified and directed.
M&L for MCB single pole & neutral 240 volt C curve 10 KA (32 to 63) Amps capacity IP 20 complete all as specified and directed.
M&L for MCB single pole, 5 to 30 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed.
M&L for MCB TP (25 to 63 Amp) 240 volt C curve 10 KA (32 to 63) Amps capacity IP 20 complete all as specified and directed.
M&L for earthing comple with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire mm as 4.0mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate no.3 including earth pit in PCC concrete 1:2:4 type B-1,Cast iron cover 10 MM THICK HINGED to CI frame ,excavation and earth work in any type of soil and including protection pipe 15mm dia and water pipe GI tubing 20mm light grade with funnel and wire mesh connected to earthing test point complete all as specified and directed. Note: (i) Rates are inclusive of 7.5m long GI earth wire 4.0mm dia (ii) Rates of CI frame, RCC Pit cover, funnel and wire mesh included in the cost of item.
Supply and fix in repair 35W LED building security light luminaire complete with pressure die cast aluminium housing and primatic polycarbonate cover to ensure better unformity of light distribution fixed on bldg wall surface including provision of GI pipe bracket complete with clamp nuts bolts and washers and making good the disturbed surface of wall complete all as specified and directed.
Supply and fix in repair 25W LED building security light luminaire complete with pressure die cast aluminium housing and primatic poly carbonate cover to ensure better unformity of light distribution fixed on bldg wall surface including provision of GI pipe bracket complete with clamp nuts bolts and washers and making good the disturbed surface of wall complete all as specified and directed.
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 40watt post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.
Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, complete all as specified and directed.
Supply and fix single phase two wire direct connected meter type SARAL, 230/240 V (L-N), Rating 5-30 A, CL.1, 50 Hz ± 5%, IP 54, Protective class II, with advanced anti-tamper capability-prevention, detection and deterrence, complete with protection cover Meter must comply following points : Standards IS 13779, IEC 62052-11, IEC 62053-21, IS 15959, DLMS Indian Companion Standard Dimensions (W x H x D) 95 x 130 x 60mm (approx.) Data storage :Midnight energy 35 days for 2 parameters Load survey More than 150 days (30min. IP) upto 5 parameters,Events Up to 300 events, compartment wise History 12 billing periods. Communication: IEC 62056-21 physical port for local communication, Optional RS 232 port over micro USB for remote communication. Note: Rates are inclusive of polycarbonate Protection cover.
S & F decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base cool day light LED ball lamp complete with fixing arrangement duly internally pre-wired, fixed in position & connecting complete all as specified and directed.
Supply & fixing bracket made out of GI light grade pipe of 40/35 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50x6mm and 04 sets of nuts,bolts and washers including painting with two coats of synthetic enamel paint over a red oxide primer including dismanting existing old and unservicess security light complete all as specified and directed.
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping including taking down old complete all as specified and directed.
Supply and fix in repair round recess mounted LED luminaire with full diffuser 15/16 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6500CCT complete all as specified and directed.
Supply and fix in repair square recess mounted LED luminaire with full diffuser 15/16 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6500CCT complete all as specified and directed.
Supply and fix in repair round recess mounted LED luminaire with full diffuser 24 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6500CCT complete all as specified and directed.
S &F in repair LED bulb 9 watt,230 volts complete all as specified and directed.
S&F in repairs laminated hylam sheet cover, ISI marked with CM/L no., cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed of following sizes:-
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
Supply and fix in repair LED reading light 3watt suitable for 220 -240volts, 50hz supply dust and water resistant, minimum 100lm/watt efficacy, 25000 to 50000 working hours and minimum 5000 to 5700CCT, including taking out old/unsv complete all as specified and directed.
S&F in repair PVC Conduits of min 25 mm dia exclusive of boxes (junction / terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables / wires and relaying after fixing of new casing capping including taking down old u/s complete all as specified and directed.
Taking down unserviceable wall mounting fan with replacement of Supply and fixing of 400 mm sweep, wall mounted cabin fan Make - Orient, Usha or Havells, 1350 RPM, single phase, 230 volts AC, 50 Hz, complete with pull cord control for speed and oscillating mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete all as specified and directed. Note :- Unserviceable fan shall be deposited in MES Store yard.
Supply only PVC extension junction box with combined switch and socket, 6A, 6 module, 3/5 Pin socket 230V for multiple electrical appliances alongwith connection of twin core PVC cable of 1.5 Sqmm upto the length of 5 Mtr complete all as specified and directed.
Supply only PVC extension junction box with combined switch and socket, 16A, 4 module, 3/5 Pin socket 230V for multiple electrical appliances alongwith connection of twin core PVC cable of 2.5 Sqmm upto the length of 5 mtr complete all as specified and directed.
Supply only in repair surface plastic PVC box 4 Module of size 85 x 145 x 42mm all side covered complete all as specified and directed.
Supply only in repair surface plastic PVC box 6 Module of size 85 x 219 x 42mm all side covered complete all as specified and directed.
Supply only in repair surface plastic PVC box 3 Module of size 85 x 85 x 40mm all side covered complete all as specified and directed.
Supply only in repair cable (FRLS) PVC insulated, PVC sheathed, multi-stranded copper conductor single core 1.5 Sqmm size complete all as specified and directed.
Supply only in repair cable (FRLS) PVC insulated, PVC sheathed, multi-stranded copper conductor single core 2.5 Sqmm size complete all as specified and directed.
Supply only in repair Cable (FRLS) PVC insulated, PVC sheathed, multi-stranded copper conductor single core 4 Sqmm size complete all as specified and directed.
Supply only in repair Cable (FRLS) PVC insulated, PVC sheathed, multi-stranded copper conductor single core 6 Sqmm size complete all as specified and directed.
Supply only in repair of PVC three core flexible wire with copper conductor of size 23/0.0076 confirming to IS-434 from connector of ceiling, exhaust fan to the mains including taking out the PVC flexible wire complete all as specified and directed.
Attending electrical complaints of domestic area deploying experienced electrician and helper and rectification of complaints to the entire satisfaction of Engineer-In-Charge and users. Note:-(i) For rectification of complaints if any electric items required to be replaced the same shall be measured and paid seperately under "supply and fixing" items. (ii) Electrician engaged by contractor for attending complaints and rectification of electrification complaints.
Note : (i) For item to be replaced under repair (day to day complaint) contactors trade man should report to complaint cell daily and take complaint from concren JE and after attending complaint he should give feedback and return the complaint slip to concern JE in the evening at 17.30 Hrs on same day. (ii) Electrical complaint to be attend within 24 Hrs from the receiving of complaint, other wise panalty of Rs.500 per complaint per day will be imposed on contractor. In this regard decision of EIC and GE will full, final and binding to contractor. (iii) Being a maintenance contract site will be handover to contractor as per complaint received from user and as per site requirement. (iv) Rates for above shall be inclusive of rates quoted by contractor against BoQ/Sch 'A'. No extra payment in this regards be made to the contractor.
Pooja Enterprise (BID ID -3416032)
M/s. Ambabhai K patel (BID ID -3409485)
Sukhi Electricals (BID ID -3408211)
SURESH ELECTRICALS (BID ID -3407536)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid