Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC HOSPITAL ROAD TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.2 L+₹1.0 L (2.16%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹70.4 L+₹22.2 L (46.2%)Rejected-Finance JYOTISH ROAD TEZPUR DISTT SONITPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Tender cost neither uploaded online nor received offiline. | |
| 5 | Rejected-Technical C O MR PIR MOHAMMAD KHAN VILL UTTAR RUPAHI PO PATHALIPAM PS BOGINADI DIST NORTH LAKHIMPUR ASSAM 787056 | LAKHIMPUR | ASSAM | 787056 | - | Rejected-Technical Tender cost neither uploaded online nor received offiline. |
| Sl No | Description | Qty | Unit | Singhs Construction L2 | M/S LAKSHMI ENTERPRISES L1 | SHRI D. C. BISWAS L3 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for Carryout periodical routine maintenance consisting of Checking, Inspection, Maintenance and servicing complete including replacement of unserviceable parts of the DG set comprising of (Engine/Alternator/Control Panel), Attending breakdown and testing of DG Set complete, i.e, engine, Alternator, etc for efficient functioning including provision of all consumables items like cotton, waste cloth, kerosine oil etc. Maintenance will be carried out of capacity 40 KVA to 62.5 KVA DG Set, complete all as specefied and directed by Engr-In-Charge.
Note: (i) S&F of Spare parts shall be measured and paid separately under respective items as shown below.
(II) Labour charges for dismantling / Taking down are deemed to be included in unit rate quoted.
(iii) Rates are included for 12 Month (4 visit Quarterly basis in normal condition) and AMC through authorised Dealer /OEM. | 6 | Job | 20,600 ₹1,23,600 | 20,500 ₹1,23,000 Lowest | 20,501 ₹1,23,006 |
| 2.00 | All as per serial item No 1 here-in-before but of capacity 125 KVA. Make : Kirloskar | 1 | Job | 29,000 ₹29,000 Lowest | 29,250 ₹29,250 | 29,250 ₹29,250 |
| 3.00 | All as per serial item No 1 here-in-before but of capacity 320 KVA. Make : Kirloskar | 2 | Job | 45,000 ₹90,000 | 41,000 ₹82,000 Lowest | 41,002 ₹82,004 |
| 3.10QUARTERLY INSPECTION AND PREVENTIVE MAINTENANCE Contractor shall provide qualified trained service engineer from Authorised Company as refered item No 1 above to visit at site with material and labour, testing equipment to check / inspection and routine maintenance of the following: - (a) DG set servicing (B-check, C-check) (b) DG set Maintenance/Health checkup. (c) Control Panel/AMF Panel/Alternator troubleshooting only. (d) Replacement of AVR, water pump, starter motor, charging alternator, Fuel, coolant & lube oil hose, solenoid as per requirement. (e) Check lube oil level and conditioning of lube oil, top up/refill if required. (f) The oil filters shall be replaced whenever oil is changed. (g) The air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required. (h) Check functioning of alternator. (I) Engine safety viz. high water temperature gauge, oil pressure gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/ replaced if required. (J) Coolant level and conditioning of coolant shall be checked and refilled if required. | ||||||
| 3.20(k) Check fan and alternator drive belts and tightened if required. (l) The governor shall be checked and tuned for proper functioning (m) Check for leaks if any and shall be rectified. (n) Checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations (o) Checking of wiring system and repairing/replacement as and when required (p) Checking of battery terminal an de-sulphating (q) Diagnosis of faults in engine and Alternator and its rectification SPECIAL INSPECTION AND MAINTENANCE: During operation if machine become unserviceable for that contractor shall provide qualified trained authorised service Engineer and technicians from kirlosker to visit at site with material & labor, testing equipment to check and attend complaints as and when called and rectify the fault within 24 hours of the DG set by following all the recommendations and instruction given in the mannual and service instruction. Note:- (i) Repair work shall be carried out through specilised firm/agency which is familiar in such work which is familiar in such work. (ii) Unserviceable parts shall be replaced with new parts (spare parts shall be measured and paid under respective items as shown below). | ||||||
| 4.00S&F following spares for replacement against faulty/deffective one for 62.5 KVA Kirloskar make Engine. MES No.- NYA, Location - DM Range | ||||||
| 4.01 | (a) SPIN ON FILTER, Cat No.- 06.436.01.0.00 | 2 | Each | 750 ₹1,500 | 725 ₹1,450 Lowest | 7,26,401 ₹14,52,802 |
| 4.02 | (b) FUEL FILTER KIT, Cat No. - 48.999.20.0.00 | 2 | Each | 450 ₹900 | 400 ₹800 Lowest | 1,111 ₹2,222 |
| 4.03 | (c) PRIMARY FILTER ELEMENT, Cat No.- 06.757.03.0.00 | 1 | Each | 1,000 ₹1,000 | 1,100 ₹1,100 | 550 ₹550 Lowest |
| 4.04 | (d) SECONDARY ELEMENT, Cat No.- 06.757.04.0.00 | 1 | Each | 500 ₹500 Lowest | 550 ₹550 | 28,350 ₹28,350 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
22 Dec 2025, 6:00 pmClosed
GE (AF) Tezpur
Air Force Station, PO - Salonibari, Tezpur - 784104
REPAIR/ MAINT OF DG SET ELECTRIC SIREN, AMF PANEL, STREET LIGHT POLE, LT PANEL, LT CABLE, EARTHING, REWINDING OF PUMP AND MOTOR AND OTHER CONNECTED MISCELLANEOUS WORK AT DM RANGE AND ALG ZIRO UNDER GE (AF) TEZPUR
2025_MES_742445_1
8134/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
ALG Ziro and DM Range
Class D category b(i)
7 documents required · 7 mandatory
₹500
GE (AF) TEZPUR
₹98,000
Yes
19 Feb 2026
2 Dec 2025
24 Dec 2025
2 Dec 2025
22 Dec 2025
16 Dec 2025
3 Dec 2025 - 9 Dec 2025
Amount
M&L for Carryout periodical routine maintenance consisting of Checking, Inspection, Maintenance and servicing complete including replacement of unserviceable parts of the DG set comprising of (Engine/Alternator/Control Panel), Attending breakdown and testing of DG Set complete, i.e, engine, Alternator, etc for efficient functioning including provision of all consumables items like cotton, waste cloth, kerosine oil etc. Maintenance will be carried out of capacity 40 KVA to 62.5 KVA DG Set, complete all as specefied and directed by Engr-In-Charge. Note: (i) S&F of Spare parts shall be measured and paid separately under respective items as shown below. (II) Labour charges for dismantling / Taking down are deemed to be included in unit rate quoted. (iii) Rates are included for 12 Month (4 visit Quarterly basis in normal condition) and AMC through authorised Dealer /OEM.
All as per serial item No 1 here-in-before but of capacity 125 KVA. Make : Kirloskar
All as per serial item No 1 here-in-before but of capacity 320 KVA. Make : Kirloskar
QUARTERLY INSPECTION AND PREVENTIVE MAINTENANCE Contractor shall provide qualified trained service engineer from Authorised Company as refered item No 1 above to visit at site with material and labour, testing equipment to check / inspection and routine maintenance of the following: - (a) DG set servicing (B-check, C-check) (b) DG set Maintenance/Health checkup. (c) Control Panel/AMF Panel/Alternator troubleshooting only. (d) Replacement of AVR, water pump, starter motor, charging alternator, Fuel, coolant & lube oil hose, solenoid as per requirement. (e) Check lube oil level and conditioning of lube oil, top up/refill if required. (f) The oil filters shall be replaced whenever oil is changed. (g) The air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required. (h) Check functioning of alternator. (I) Engine safety viz. high water temperature gauge, oil pressure gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/ replaced if required. (J) Coolant level and conditioning of coolant shall be checked and refilled if required.
(k) Check fan and alternator drive belts and tightened if required. (l) The governor shall be checked and tuned for proper functioning (m) Check for leaks if any and shall be rectified. (n) Checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations (o) Checking of wiring system and repairing/replacement as and when required (p) Checking of battery terminal an de-sulphating (q) Diagnosis of faults in engine and Alternator and its rectification SPECIAL INSPECTION AND MAINTENANCE: During operation if machine become unserviceable for that contractor shall provide qualified trained authorised service Engineer and technicians from kirlosker to visit at site with material & labor, testing equipment to check and attend complaints as and when called and rectify the fault within 24 hours of the DG set by following all the recommendations and instruction given in the mannual and service instruction. Note:- (i) Repair work shall be carried out through specilised firm/agency which is familiar in such work which is familiar in such work. (ii) Unserviceable parts shall be replaced with new parts (spare parts shall be measured and paid under respective items as shown below).
S&F following spares for replacement against faulty/deffective one for 62.5 KVA Kirloskar make Engine. MES No.- NYA, Location - DM Range
(a) SPIN ON FILTER, Cat No.- 06.436.01.0.00
(b) FUEL FILTER KIT, Cat No. - 48.999.20.0.00
(c) PRIMARY FILTER ELEMENT, Cat No.- 06.757.03.0.00
(d) SECONDARY ELEMENT, Cat No.- 06.757.04.0.00
(e) CONTROL UNIT, Cat No.- 02.999.91.0.SP
(f) ENGINE WIRING HARNESS, Cat No.- 4H.905.20.0.00
(g) AVR, Cat No.- 2H.811.32.0.00
(h) DIODE ASSEMBLY
(j) DIODE PLATE
(k) GOVERNOR CARD
(l) FUEL PIPE, Cat No.- 4H.031.04.0.00
(m) FUEL PIPE, Cat No.- 4H.031.05.0.00
(n) Hose Pipe
S&F following spares for replacement against faulty/deffective one for 40 KVA Cummins make Engine. MES No.- NYA, Location :- DM Range
(a) Element Oil Filter, Cat No.- 01220962
(b) Element Fuel Filter, Cat No. - 01492967
(c) Element Air Cleaner, Cat No.- 3814695
(d) Element Air Cleaner, Cat No.- 3814696
(e) CONTROL UNIT, Make; Kirloskar
(k) GOVERNOR CARD
(g) AVR, Cat No.- 2H.811.32.0.00
(f) ENGINE WIRING HARNESS, Cat No.- 4H.905.20.0.00
(l) FUEL PIPE, Cat No.- 4H.031.04.0.00
(m) FUEL PIPE, Cat No.- 4H.031.05.0.00
(n) Hose Pipe
(e) Panel Control, Cat No.- A054G527
S&F following spares for replacement against faulty/deffective one for 40 KVA Crompton Greaves make Engine. MES No.- NYA, Location- DM Range
(a) Lube Oil Filter, Cat No.- 605411880008
(b) Filter Element with O Ring, Cat No. - 001200240911.
(c) Filter insert with O ring, Cat No.- 001200240912.
(d) Air filter element, Cat No.- P21109230031.
(e) Air Pre filter element, Cat No.- P21109230032.
(f) Relay Card, Cat No.- 141100195217.
(g) Governor, Cat No.- 106902090056.
(h) Mag pick up, Cat No.- 105652190001.
S&F following spares for replacement against faulty/deffective one for 320 KVA, Kirloskar make Engine.
(a) LUBE OIL FILTER, Cat No.- DV0.014.11.0.00
(b) LUBE OIL FILTER, Cat No.- DV0.014.27.0.00
(c) FUEL FILTER CARTRIDGE, Cat No.- DV0.020.03.0.00
(d) AIR CLEANER PRIMARY ELEMENT, Cat No.- DV8.505.74.0.00
(e) AIR CLEANER SAFETY ELEMENT, Cat No.- DV8.505.75.0.00
S&F following spares for replacement against faulty/deffective one for 35 KVA Kirloskar make Engine.
(a) SPINON LUBE OIL FILTER, Cat No.- 04.270.01.0.00
(b) FUEL FILTER ELEMENT PRIMARY, Cat No.- 3H.132.01.0.00
(c) FUEL FILTER ELEMENT SECONDARY, Cat No.- 3H.132.02.0.00
(d) PRIMARY AIR CLEANER ELEMENT, Cat No.- 04.586.03.0.00
(e) AIR CLEANER SAFETY ELEMEN, Cat No.- 04.586.04.0.00
(f) OIL BATH AIR CLEANER WITH RUBBER SLEEVE, Cat No.-03.061.70.0.00
S&F following spares for replacement against faulty/deffective one for 15 KVA Kirloskar make Engine.
(a) LUBE OIL FILTER ELEMENT, Cat No.- 03.040.19.0.00
(b) PREFILTER ELEMENT, Cat No.- 34.032.02.0.00
(c) FUEL FILTER ELEMENT, Cat No.- 34.032.12.0.00
(d) PRIMARY AIR CLEANER ELEMENT, Cat No.- 04.586.03.0.00
(e) AIR CLEANER SAFETY ELEMENT, Cat No.- 04.586.04.0.00
Supply fix in repair SMPS battery charger 10 Amps, 24 V suitable for autmatic charging of battery to DG set from AMF panel/LT panel of rating 320 KVA. Make Kirloskar, Cat No.- 6H.849.09.0.00 or equivalent model in Procom/NHP/Cummins
S&F MAGNETIC PICK UP 16X1.5 THREAD for 320 KVA DG Set, Cat No.- F6.741.16.0.00
S&F THERMOSTAT ELEMENT for 320 KVA, Cat No.- KL6.055.34.0.00
S&F LUBE OIL PRESS SENDOR 0.75 +/- 0.15 B for 320 KVA DG Set, Cat No.- 21.279.04.0.00
S&F LUBE OIL TEMP GAUGE for 320 KVA DG Set, Cat No.- 34.183.03.0.00
S&F STOP SOLENOID ASSLY: 24VDC for 320 KVA DG Set, Cat No.-F6.399.10.0.00
S&F FUEL STOP SOLENOID ASSEMBLY (ELECTRAL CONTROL MAKE,INDIGENIOUS, ENERGIZE TO STOP TYPE, 24VDC) WITH SUITABLE LINKAGE & HARDWARE for 320 KVA DG Set, Cat No.-F6.1356.20.0.00
S&F LOW OIL PRESSURE SWITCH 1.7KG/CMSQ for 320 KVA DG Set, Cat No.- 49.156.01.0.00
Disconnection of existing AMF Panel of DG Sets of any capacity/rating (63-750KVA), form all incoming and outgoing electrical connections,checking serviceability of each components viz. capacitors, contactors,relays,timers, MCB's, MCCB's, indicator lights,display meters,controller etc.,replacement of burnt out internal wirings with with suitable size FRLSH PVC insulated multistranded copper conductor wires,replacement of defective lugs,thimbles etc.,replacement of defective parts,through cleaning of panel both internally and externally, re interconnection of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning,complete all as specified and directed. Notes:- (i) The work shall be carried out through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by the Engineer in Charge. (ii) Spare Parts for replacement will be measured and paid seperately under respective items of this BOQ here in after.
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 400, AC-3 rating 400 Amps and AC-1 rating 425 Amps,complete all as specified. [Cat No.CS94144 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 110, AC-3 rating 110 Amps and AC-1 rating 160 Amps,complete all as specified. [Cat No.CS94137 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply Only, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 50, AC-3 rating 50 Amps and AC-1 rating 85 Amps,complete all as specified. [Cat No.CS97075 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply & fix in repair SMPS battery charger 10 Amps, 12 V suitable for autmatic charging of battery to DG set from AMF panel/LT panel of rating 10 KVA to 160 KVA. Make Kirloskar, Cat No.- 02.872.18.0.00 or equivalent model in Procom/NHP/Cummins
S&F KG645 CONTROLLER UNIT WITH 4-20MA for 10 KVA to 160 KVA DG Set, Cat No.-02.026.09.0.00
S&F WIRING HARNESS for KG 645: 4R1040, Cat No.-4H.905.20.0.00
S&F STOP SOLENOID ASSLY-12VDC SINGLE COIL for 10 KVA to 160 KVA DG Set, Cat No.- 4H.150.30.0.00
S&F KIRLOSKAR GREEN AVR (MODEL : TAVR-10/TAVR-20/TAVR-14 for 10 KVA to 82.5 KVA DG Set, Cat No.- 2H.811.32.0.00
S&F ADV LOAD DUMP MODULE 24VDC, Cat No.DV8.858.16.0.00
S&F 24 V DC RELAY BOARD 2CH. (70 AMP.) 1C/O. BATTERY -VE SIGNAL,DIN MOUNTED, Cat NO.- KV8.853.05.0.00
M&L for calibration of fuel injection pump including minor spares and repair and servicing of injector nozzeles of 35 KVA DG Set complete all as specified and directed.
Dismantling the radiator and water pump assembly from DG set of any capacity after removing hose pipe connection, nut, bolts etc and taking out the same to civil workshop (if required) for repair and descaling of radiator using descaling chemical etc as approved by Engr-In-Charge to remove mud/deposit on fins and copper tubes including brazing of copper tubes, replacement of cover etc all as directed by Engr-In-Charge for DG Set of following capacity and re-fixing after replacement of unserviceable hose pipes and clamps of Capacity 320 KVA, complete all as specified and directed.
Disconnecting the self starter (24V) from the engine body, dismantling the same, checking for identification of faulty spares and reassemblig the same after replacement/renewal of the following spares, if required, including refixing to its original position all as specified and directed Note :- spares, required to be replaced, shall be measured and paid under respective items mentioned here in under.
S&F fixing following spares for fixing in repair against the faulty one for the self starter(24V) -
(a) S&F clutch assembly (Make : LUCAS / TVS)
(b) S&F Bendex pinion (Make : LUCAS / TVS)
(c) S&F Solenoid switch (Make : LUCAS / TVS)
(d) S&F Carbon Brush (Make : LUCAS / TVS)
(e) S&F Armature Field Coil (Make : LUCAS / TVS)
(f) S&F Bush (Make : LUCAS / TVS)
(g) Self armature coil (Make : LUCAS / TVS)
M&L for calibration of fuel injection pump including minor spares and repair and servicing of injector nozzeles of 62.5 KVA DG Set complete all as specified and directed.
Supply and filling of engine oil 20W/40 multi grade, to top up / refilling of all DG set of various capacity, model & location here-in-before as per the direction of engr-in-charge. (Make : GULF/SERVO/VALVOLENE)
Supply and pouring of anti corrosive/antifreeze coolent suitable for radiator for Kirloskar/Cummins make engine as per the requirement as directed by Engr-in-charge for various capacities of DG Set (Make : SERVO KOOL/CASTROL/PUROKOOL/K-KOOL)
Supply and pouring distilled water for battery and radiator as directed.
Dismantling the radiator and water pump assembly from DG set of any capacity after removing hose pipe connection, nut, bolts etc and taking out the same to civil workshop (if required) for repair and descaling of radiator using descaling chemical etc as approved by Engr-In-Charge to remove mud/deposit on fins and copper tubes including brazing of copper tubes, replacement of cover etc all as directed by Engr-In-Charge for DG Set of following capacity and re-fixing after replacement of unserviceable hose pipes and clamps of Capacity 40 KVA or 62.5 KVA, complete all as specified and directed.
Disconnecting the self starter (12V) from the engine body, dismantling the same, checking for identification of faulty spares and reassemblig the same after replacement/renewal of the following spares, if required, including refixing to its original position all as specified and directed. Note :- spares, required to be replaced, shall be measured and paid under respective items mentioned here in under.
S&F fixing following spares for fixing in repair against the faulty one for the self starter(12V) -
(a) Clutch assembly (Make : LUCAS / TVS)
(b) Bendex pinion (Make : LUCAS / TVS)
(c) Solenoid switch (Make : LUCAS / TVS)
(d) Carbon Brush (Make : LUCAS / TVS)
(e) Armature Field Coil (Make : LUCAS / TVS)
(f) Bush (Make : LUCAS / TVS)
(g) Self armature coil (Make : LUCAS / TVS)
Supply & fixing indicator lamp LED type, 220 volt AC (RED/YELLOW/BLUE) for each Phase, including taking down old unserviceable one, complete all as specefied and as directed. (Make: L&T/RAAS/SIEMENS)
Supply and connect lead acid batteries of 12 Volts, 100 AH, suitable for DG Set all as specified and as directed. [Model : Xpress (XP1000) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']
Supply and connect lead acid batteries of 12 Volts, 150 AH, suitable for DG Set all as specified and as directed. [Model : Xpress (XP1500) of Make'Exide'or equivalent Model of Make 'Amron'/'Amco']
S&F BATTERY CABLE ASSEMBLY (FOR -VE & +VE) for connection of Battery to Self with copper Lugs, copper cable and copper connector of baterry as per existing size for both terminal, complete all as specified and directed.
Repairing of DG set opening doors by replacing of hing and make serviceable complete all as directed by Engr-in-charge.Note All necessary fabrication work, spare parts complete included in unit rate quated by contractor.
Comprenesive maintenance, rapair and upgradation of software including renewal/replacement of defective parts of all existing fire detection system complete consisting of addressable fire control panel, Remote Terminal Unit panels, smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier, Loud speaker, Loop isolator, Zone monitor module, Modem etc. to make 100 % serviceability of the complete incl checking of fire detector, cleaning of heavy greasy deposit if any, checking the connection of batteries, the alarm function of control and indicating eqpt be checked by the operation of trigger device in each zone as described, the system installed in Fire station every month during first or last week as directed by engineer-in-charge Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" (ii) Contractor's rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the user. Note : "Repair and maintenance of Fire Alarm system should be done through OEM or through the authorized service provider of the OEM or any other agency dealing with the installation and maintenance of FIRE ALARM REMOTE COMMUNICATION SYSTEMS (RTU) and has vast experience in the relevant field as approved by the next higher authority to the Accepting Officer".
Supply only of 12 V, 12 AH battery for back up to all FACP panel. Make: Exide/Amar Raja
Supply and fixing in repair combined scattered light smoke and temperature multisensor detector programmed to detect either smoke or heat, or both depending on the type of system having sensitivity in accordance with existing fire alarm system of including taking down existing unservicable detectors complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repair of electronically addressable intelligent resettable type Manual Call Point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below complete all as specified and directed by the Engineer-in-Charge. :- a)Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key. d) Ingress Protection IP-24 & Material-ABS for existing L & T Electrical & Automation(schrack-seconet) fire alarm system.
Dismantling of steel tubular pole of any size from bottom by demolition of concrete complete all as directed
S&F LT steel tubular swaged poles complete with cast iron base plate,finial taper plug, bolts,nuts & screws as specified type 410 SP-22 (9 mtr long) complete all as specified as directed.Note Excavation & PCC work shall be measured and paid seperately
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
All as per item No 49.00 here in before but Excavation in trenches exc. 1.5m wide and n. exe 3 mtr depth
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
Taking down/out unserviceable or serviceable LT UG Cables of nominal Cross Sectional Area 95 sqmm 3.5 core and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed.
All as per Item No. 60 above, but Nominal Cross-Sectional Area 50 Sqmm 3.5 Core.
All as per Item No. 60 above, but Nominal Cross-Sectional Area 35 Sqmm 3.5 Core.
All as per Item No. 60 above, but Nominal Cross-Sectional Area 25 Sqmm 4 Core.
All as per Item No. 55 above, but Nominal Cross-Sectional Area 16 Sqmm 4 Core. (NOTE for Item No.60 to 64 : Earth Work shall be Measured and Paid for separately under relevant Items).
Supply & Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 95 sqmm 3.5 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.
All as per Item No. 65 above, but Nominal Cross-Sectional Area 50 Sqmm 3.5 Core.
All as per Item No. 65 above, but Nominal Cross-Sectional Area 35 Sqmm 3.5 Core.
All as per Item No. 65 above, but Nominal Cross-Sectional Area 25Sqmm 4 Core.
All as per Item No. 65 above, but Nominal Cross-Sectional Area 16Sqmm 4 Core.
S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Re-laying only old Brick in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before), complete all as directed.
M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 20 graded stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site.
Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and as directed.
S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
S&F Galvanised Iron Pipe 32mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.
Supply fix in repair for MCCB confirming to IEC 60947-2, AC 415 Volt, four pole 100 Amp 25 KA with adjustable overload setting: 0.8 -1.0 x in and adjustable short circuit setting: 6-10 x ln, complete all as specified and directed Make : C&S/Havells/Scnider/ABB/L&T/Legrand.
Supply fix in repair for MCCB confirming to IEC 60947-2, AC 415 Volt, four pole 630 Amp 50 KA with adjustable overload setting: 0.8 -1.0 x in and adjustable short circuit setting: 6-10 x ln, complete all as specified and directed Make : C&S/Havells/Scnider/ABB/L&T/Legrand.
Supply fix in repair for MCCB confirming to IEC 60947-2, AC 415 Volt, three pole 100 Amp 25 KA with adjustable overload setting: 0.8 -1.0 x in and adjustable short circuit setting: 6-10 x ln, complete all as specified and directed Make : C&S/Havells/Scnider/ABB/L&T/Legrand.
Supply fix in repair for MCCB confirming to IEC 60947-2, AC 415 Volt, four pole 63 Amp 16 KA with adjustable overload setting: 0.8 -1.0 x in and adjustable short circuit setting: 6-10 x ln, complete all as specified and directed Make : C&S/Havells/Scnider/ABB/L&T/Legrand.
Repair of Unserviceble LED Light on the pole/building /watch tower/sunshelter by refreshing of connection, changing of connector, changing of Wire, tighting of wire on ACSR conductor, etc complete all asspecified and directed. Note 1. cost of connector and suitable size of Cu/Al wire up to 1.5 mtr shall be measured in quoted rate.2. Supervisor take complain from power house on daily basis.
Supply only LED driver suitable for 45/60 Watt open type complete all as specified as directed. Make Philips/Crompton/Bajaj or as per fitting make.
Supply only LED driver suitable for 70/75 Watt open type complete all as specified as directed. Make Philips/Crompton/Bajaj
Supply and Fixing in replacement street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 70/72 Watts including 10 KV SPD, after taking old unserviceable light fittings all specified and directed by Engr-in-Charge. Make :- Crompton (Cat No.- CRP-409-70-57-SL-GL-NSG) or equiv make in PS.
S & F as in repair for 150 Watt LED ( CCT 5700 - 6500 K ), cradle / surface mounted Flood light made of aluminium die cast housing with power coating, having excellent thermal management along with IP 66 protection with clamp as per site requirment complete all as specified and directed by Engr-in-charge. with efficiency of 110 lm/W and lumen output of >= 11000 lumen. Make :- Crompton /Havells/ Bajaj/ Wipro /HPL
Materials and Labour for maintenance free chemical earthing system using 04 (four) spike 17.2mm dia, 3000mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Under Writers laboratories (UL) 467-2007 or latest with 250mm long copper strips of size 50X3 mm, exothermally welded on top of electrode complete including augering (boring) 100-125mm dia hole as required for electrode in any type of soil and back filling with Earth Enhancing Chemical back filled compound as per IEEE 80 2000 Clause 14.5(c), conforming to IEC 62561-7, min quantity of compound used 40Kg), i.e. total qty 160 Kg per electrode, conforming to IEEE/BS standrads including pit cover light weight made out of high quality polymer with lid made of HDG steel, including nessary testings and commissioning, complete all as specified and as directed. Notes:- (i) The work of earthing shall be carried out by authorised trained rep of OEM. (ii) The acceptable earth resistance at earth busbar/ test point shall be as per users requirement as desired by Engr-in-Charge but it should be below 01 Ohm. At certain locations, it may not be possible to achieve desired earth resistance with one electrode / pit due to higher soil resistivity,in such cases, provision of loop earthing consisting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. (iii) The procedure mentioned here-in-before for one earth pit shall be repeated for other earth pits. (iv) Additional earth electrode pits and loop conductor shall be measured and paid seperately . (v) The quoted rate shall also be included the following elements: (a) Complete earthwork including drilling holes for electrode.(b) Earhing electrode-01(One) No Only (c) Backfilling carbon based ground enhancing compound (GEC). (d) Pit cover light weight made out of high quality polymer with lid made of HDG steel. (e) Soil suitable for agricultural purpose required for each pit. (f) Copper strip as earthing lead of size 50mmx3mm, 250 mm long only, beyond 250mm, other size will be measured and paid for separately under respective item(s) in this BOQ. (g) All Labour and T&P required including testing of earth network.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of galvanised iron steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x 10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion after taking down old earthing complete all complete as specified and directed.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. ( GI strip upto 7.5m including testing consider in this item).
Supply and fixing GI strip 32mmx6 mm complete and buried in ground .
S&F Copper strip 20 x 3.15 mm with saddles and fixing screws etc.on roof/wall/underground and joining the same with New earth test point with brazing complete all as specified and directed by Engr-in-Charge.
M&L cement concrete PCC type C-2 (1 : 3 : 6) 40 mm graded stone aggregate for pole foundation including necessary form work and forming neat finish surfaces complete all as directed.
M&L cement concrete PCC type C-2 (1 : 2 : 4) 12.5mm graded stone aggregate for copping of pole for existing/new pole including necessary form work and forming neat finish surfaces complete all as directed.
Taking up down galvanised steel tubing and connection of size 25mm dia and removal of U/S pipe from site of work complete all as specified and directed.
All as per Item No 93 here-in-before 40mm dia.
All as per Item No 93 here-in-before 50mm dia.
All as per Item No 93 here-in-before 80mm dia.
Material and labour for galvanised steel (Gl) tubing medium grade with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, back- nuts, diminishing pieces, caps, plugs and unions, etc.) and laying in trenches, wall, floor etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good for following pipe bore size.
(a) 25 mm bore
(b) 40 mm bore
(c) 50 mm bore
(d) 80 mm bore
Supply and fixing of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends of size 25 mm dia for iron pipe and fixed
Supply and fixing of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends of size 40 mm dia for iron pipe and fixed
Supply and fixing of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends of size 50 mm dia for iron pipe and fixed
Dismantling of GI pipe connection from the pressure filter plant capacity 10000 gallon, opening the man hole and removal/taking out the old filter medias completely from oxidation chamber, iron removal filter and pre filter and depositing the same to a distance not exceeding 100 mtr and re-fixing the pipes in the original existing position after replacement of unserviceable PVC nozzle (Dom type) including replacement gasket main hole cover and necessary nuts and bolts as required complete all as specified and directed
Supply and fixing PVC nozzle (Dom type) of pre-filter and iron removal filter all as specified and directed
M&L for filling in filteration Media sand effective size 0.35 to 0.50mm hard and resistant, quartz or quartzite, free from clay, fine particals, soft grains and dirt of every description confirming to IS8419, Part-I, inside existing rapid gravity filter and pressure filter, complete all as specified and as directed.
Materials and Labour for filling in, filteration Media Gravel, size 3mm to 6mm, consisting of hard rounded stones with average specific gravity of not less than 2.5 and free from clay, sand, loam and organic impurities of any kind, conforming to IS 8419, Part-I, inside rapid gravity filter & pressure filter, complete all as specified and directed.
Materials and Labour for filling in, filteration Media Gravel, size 6mm to 12mm, consisting of hard rounded stones with average specific gravity of not less than 2.5 and free from clay, sand, loam and organic impurities of any kind, conforming to IS 8419, Part-I, inside rapid gravity filter & pressure filter, complete all as specified and directed.
Materials and Labour for filling in, filteration Media Gravel, size 12mm to 20mm, consisting of hard rounded stones with average specific gravity of not less than 2.5 and free from clay, sand, loam and organic impurities of any kind, conforming to IS 8419, Part-I, inside rapid gravity filter & pressure filter, complete all as specified and directed.
Materials and Labour for filling in, filteration Media Gravel, size 20mm to 40mm, consisting of hard rounded stones with average specific gravity of not less than 2.5 and free from clay, sand, loam and organic impurities of any kind, conforming to IS 8419, Part-I, inside rapid gravity filter & pressure filter, complete all as specified and directed.
Materials and Labour for filling in, Carbofelt compound, in aeration towers/ gravity filters/pressure filters/complete all as specified and directed.
Materials and Labour for filling in Manganese Dioxide (MNO2) media , approximate size 20mm x 24 mm with Mno2 contents minimum 65% in aeration towers / oxidation chambers complete all as specified and directed .
supply and fix in repairs, PP/LDPE, 3/8'' BSP thread strainer suitable for pressure filter, complete all as specified and directed.
Material and Labour for applying two coats of anti corrosive and non toxic black bituminous (Compatible with Drinking water) to internal brick, stone, concrete, asbestos cement or plaster surfaces of existing open type rapid sand gravity filter and sediment tank after complete descaling of surfaces and including preparation of surfaces, complete all as specified and directed.
Material and Labour for applying two coats of anti corrosive and non toxic blue bituminous paint (Compatible with drinking water) over a coat of red oxide Zinc chrome primer to external steel surfaces of existing IRP of capacity 10000 gallons per hour, comprising of pre-filter, pressure filter, oxidation chamber/media chamber etc. after complete descaling of surfaces and including preparation of surfaces (Approx area of painting 45.00 Sqm) complete all as specified all as specified and directed.
Chemical analysis of water collected of one bottle of treated water (filtered water) and one bottle of untreated water (ground water) collected from different pump houses of GE (AF) Tezpur are forwarded herewith as sample for iron contents with standards of quality for drinking water at Defence Research Laboratory (DRL) Tezpur (Assam) and putup the certificates seperately for each sample to Engineer-in-Charge twice in a contract period complete all as specified and as directed.
Singhs Construction (BID ID -3504930)
SHRI D. C. BISWAS (BID ID -3504961)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_831395.xls
BOQ • 0.41 MB
Tender8134.pdf
Tender Documents • 1.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .