GE (AF) NO 2 JODHPUR
GE (AF) NO 2 JODHPUR
REPAIR AND MAINT OF HEATING AND COOLING APPLIANCES AT AFS MOUNT ABU AND GURUSHIKHAR UNDER AGE E/M, GE(AF) NO 2 JODHPUR
2021_MES_464943_1
8267/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) NO 2 JODHPUR
AS PER TENDER
6 documents required · 6 mandatory
₹500
GE (AF) NO 2 JODHPUR
₹25,060
Yes
9 Nov 2021
3 Aug 2021
1 Sept 2021
3 Aug 2021
30 Aug 2021
17 Aug 2021
60 days
Amount
M&Lfor Maintenance, servicing cleaning of the following air conditioner at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switchs condesor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items. (ii) After servicing the said ACs will be fixed to its original position. (a) 2 ton split type
(b) 1.5 ton split type
(c) 2 Ton window type
Supply and charging refrigerant F-22/R-22 (Mefron/Refron) gas at site after detection and rectification of any leackage in the system by sing CO2 gas and flushing the complete system thoroughly with nitrogen gas complete all as specified & directed.
Description all as per Srl item No. 4.00 here-in-before but R-134 complete all as specified & directed. Note for Srl item No. 4.00 & 5.00 of BOQ/Sch of works : - The cost of nitrogen and CO2 gas used for leakage test and pressure test prior to filling charging gas shall be deemed to be included in this item rate
Disconnecting, cutting and taking out u/s sealed unit (Hermitically sealed) of any capacity and make and model against item Nos 7.00 to 13.00 here in after and removing materials for taking credit. complete all as specified & directed. Note:- Unserviceable compressor may be given with more than one cut
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for window type AC of 2 ton Cap complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for for split type AC of 2 ton Cap complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for for split type AC of 1.5 ton Cap.of any make complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for refrigerator of 165 Ltrs capacity complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for refrigerator of 180 Ltrs capacity complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load for refrigerator of 310 Ltrs capacity complete all as specified & directed.
M & L for installing , testing , commissioning hermitically sealed compressor of the existing make and model incl soldering, welding, brazing and testing on load all as spd and directed for water dispanser complete all as specified & directed. Note for Srl item No. 7.00 to 13.00 of BOQ/Sch of works : - (a) Cost of gas shall be measured and paid separately. (b) Compressor shall match with size, make and modal of existing compressor. (c ) Unit rate include transporation to site of work and back as applicable
Taking down old u/s capacitor of any size
Supply & replace starting capacitor 100-120 mfd for window type room air conditoner 2.0 ton capacity Make Apcos/Natraj/Tesla/Spark complete all as specified & directed.
Supply and replace running capacitor 36 mfd Make Apcos/Natraj/Tesla/Spark complete all as specified & directed.
Description all as per Srl item No 15.00 here-in-before but 45 mfd complete all as specified & directed.
Taking down of old u/s starting relay of 2.00 ton window AC
S& F starting relay for 2 Ton window type room air conditioner Make Renutrol/Indfoss complete all as specified & directed.
Taking down old u/s over load relay of any size
M&L for replacement of over load relay for split type AC 1.5 ton capacity complete all as specified & directed.
S&F replacement of over load relay for split type AC 2 ton capacity. Make-Indofoss Runutrol, shree Ram complete all as specified & directed.
Taking down old u/s thermostat swich of any size
S&F thermostat switch for 2 Ton window type room air conditioner complete all as specified & directed.
Taking down old u/s blower motor of AC any size
S&F blower motor for window type room air conditioner 2 Ton complete all as specified & directed.
S & F Blower motor suitable for out door unit of split type AC 1.5 Ton complete all as specified & directed.
S& F Blower motor suitable for out door unit of split type AC 2Ton complete all as specified & directed.
S & F Blower motor suitable for in door unit of split type AC 1.5Ton complete all as specified & directed.
S & F Blower motor suitable for in door unit of split type AC 2 Ton complete all as specified & directed.
Taking down of old u/s blower fan of AC any size
S& F blower fan as existing make and model / shape for window type room air conditioner 2 Ton capacity complete all as specified & directed.
S & F Blower fan suitable for outdoor unit of split type AC 1.5 Ton complete all as specified & directed.
S & F Blower fan suitable for outdoor unit of split type AC 2 Ton complete all as specified & directed.
S & F Blower fan suitable for indoor unit of split type AC 1.5 Ton complete all as specified & directed.
S & F Blower fan suitable for indoor unit of split type AC 2 Ton complete all as specified & directed.
taking out old u/s condensing coil of window AC 2 TON
S & F condensing coil of window type room air conditioner 2 ton capacity and replacement with new condesing unit of appropriate size and modal including welding brazing etc and testing on load complete all as specified & directed.
taking out old u/s evaporator coil of 2 ton window AC
S & F evaporator coil of window type 2.0 ton AC complete all as specified & directed.
Taking out old u/s Air filter of AC any size
S & F air filter suitable for window type AC 2 Ton capacity as per samples complete all as specified & directed.
S & F air filter suitable for split type AC 1.5 Ton capacity as per samples complete all as specified & directed.
Taking out u/s Power circuit board of AC's 1.2/2 Ton
S&F power circuit board (IC, relay, transformer) of 2 ton AC split type complete all as specified & directed.
S & F power circuit board (IC, relay, transformer) of 1.5 ton AC split type complete all as specified & directed..
Taking down old u/s copper pipe of AC
M& L 12.5mm dia copper pipe for AC 1.5 Ton split type AC complete all as specified & directed.
Maintenance, servicing & repair of refrigerator 165 ltrs capacity any make & modal cleaning the various components and replacement of following spare complete all as specified & directed.: (a) Chill tray - 01 Nos (b) Shelves - 02 Nos (c) Freezer door - 01 No (d) Door gesket - 01 No (e) Door lock - 01 No (f) Bulb holder & bulb - 01 No (g) Bimetal relay (h) Defrost heater. (j) PTC relay (k) Fan motor (l) Thermostat switch
Description all as per Srl item No. 49.00 here-in-before but 310 Ltrs capacity complete all as specified & directed : (a) Chill tray - 01 Nos (b) Shelves - 02 Nos (c) Freezer door - 01 No (d) Door gesket - 01 No (e) Door lock - 01 No (f) Bulb holder & bulb - 01 No (g) Bimetal relay (h) Defrost heater. (j) PTC relay (k) Fan motor (l) Thermostat switch
Taking down, servicing, and refixing of Geyser 25 Ltrs by unscrewing of , MS clamps, inlet , outlet connections , any leakage & alike complete all as specified & directed. Note :- Spare parts will be measured & paid separately
Taking down of pld u/s heating element of 1.5/2 KW
S & F Heating element -1.5 KW complete all as specified & directed.
S & F Heating element -2 KW complete all as specified & directed.
Taking down of old u/s thermostat swich for water heater of any size and any shape
S & F Thermostat switch of capacity 1.5/2.0KW complete all as specified & directed.
Taking down of old u/s PVC connection
M& L for PVC connection 15mm x 60 cm long complete all as specified & directed.
Taking down and refixing ceiling fan, ceiling cable end , dismantling blades and removing fan and blades to store for repair complete all as specified & directed.
Taking down of old u/s condenser 2.5 MFD
S& F condensor 2.5 MFD complete all as specified & directed.
Taking down of old u/s MS clamp ,nuts and bolts set
S& F set of MS clamp with MS nuts, bolts, quarter pin complete all as specified & directed.
Taking down of old u/s down rod for ceiling fan rod of any size
S& F for down rod for ceiling fan of size 40 cm complete all as specified & directed.
M&L for rewinding of ceiling fan with existing gauge copper winding wire with insulation material complete for 1200 mm sweep complete all as specified & directed.
M&L for rewinding of wall mounted fan with existing gauge copper winding wire with insulation material complete for 400 mm sweep complete all as specified & directed.
M&L for painting of ceiling fans complete , in situ with synthetic enamel paint by spraying including filling cavaties with filler , one coat after cleaning all dust etc complete all as specified & directed. Note :- Taking down and fixing of exhaust fan shall be deemed in this item rate
Taking down & refixing, greasing, cleaning servicing of exhaust fan 230 V SP 300 mm to 450mm sweep by unscrewing of blades, capacitor, winding cable, ball bearing cleaning alike & alike complete all as specified & directed.
Taking down old U/S Exhaust fan Arms and S & F for arm of 300 mm sweep to 450mm Sweep exhaust fan (Set of 4) complete all as specified & directed.
S&F blade for 300 mm sweep exhaust fan complete all as specified & directed.Including Taking down of the same.
S&F blade for 450 mm sweep exhaust fan complete all as specified & directed.Including Taking down of the same.
M& L for ball bearing of existing size for exhaust fan 300 mm sweep complete all as specified & directed. Including taking down for the same.
M& L for ball bearing of existing size for exhaust fan 450 mm sweep complete all as specified & directed. Including taking down for the same.
M& L for ball bearing of existing size for ceiling fan 1200 mm sweep complete all as specified & directed.
Supply and fix capacitor 4 MFD complete all as specified & directed.
M&L for rewinding of exhaust fan of size 300 mm with existing gauge copper winding wire with insulation material complete all as specified & directed.
M&L for rewinding of exhaust fan of size 450 mm with existing gauge copper winding wire with insulation material complete all as specified & directed.
M & L for painting of exhaust fan of any size complete by using synthetic enamel paint by spraying & applying one coat after cleaning/scraping etc complete all as specified & directed. Note :- Taking down and fixing of exhaust fan shall be deemed in this item rate
Taking down of old u/s rusted sheet metal enclosure complete
S&F Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Metallic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete Make Havells/MDS/Legrand complete all as specified & directed.
Taking down old u/s PVC cable of size 3 core 70/.0076, Supply And fix the same.
Shifting and refixing of Geyser of any Capacity.
boon construction company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .