Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹19.5 L+₹42,959 (2.25%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹19.8 L+₹77,896 (4.08%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹20.7 L+₹1.7 L (8.75%)Rejected-Finance 00 BACHUAPAR RAJESULTANPUR ALAPUR AMBEDKAR NAGAR UTTAR PRADESH 224176 | AMBEDKAR NAGAR | UTTAR PRADESH | 224176 | L4 | Rejected-Finance Rejected being |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE(N)AMB-43/2023-24 PROVN OF MECHANICAL LAUNDRY IN KLP UNDER GE (NORTH) AMBALA CANTT
2023_MES_615478_4
GE(N)/AMB-43/2023-24
Open Tender
Civil Works
Item Rate
90 days
GE (N) AMBALA CANTT
As per tender documents
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹40,000
Yes
1 Apr 2024
16 Feb 2024
11 Mar 2024
16 Feb 2024
9 Mar 2024
23 Feb 2024
16 Feb 2024 - 23 Feb 2024
Amount
Supply, install, testing and commissioning Front loading and unloading washing machine with High-speed extraction, fully suspended soft mount type, Stability – An out of balance switch avoids over vibration wash cycles, Stainless steel construction, Hygeinic wash and option to set the wash temperature upto 90 C, Electro polished stainless steel heater element Quick water intake and discharge for optimal productivity and savings with following specifications: Fully Programmable PLC Large LCD display showing complete information, pause and continue features to be provided in case of power loss Easily modifiiable preset program, with a large, LCD display showing complete information of the program Pause and continue features are provided in case of power outage A single motor with a variable frequency inverter drive renders various speeds for washing, distribution and low, medium and high spin extraction. Safety Features Emergency stop switch Both manual and auto door lock mechanisms ensure the door stays closed during operation Heavy duty bearing housing and pulley construction make for an extremely rugged and resourceful machine Smooth operation with soft start and stop ensures least wear and tear
item No. 01 (contd....) Inverter Drive The inverter enables smooth start/stop/Acceleration/ Deceleartion function of the washer. Avoids the motor’s high starting current, Door Lock Both manual and auto door lock mechanisms, which ensure the door is closed during the operation. An emergency stop switch is provided. The door lock is electric type. Technical Specifications (a) Capacity - 30 Kg (b) Basket Volume - 305 Ltr (Minimum) (c) Basket diameter - 840 mm (Minimum) (d) Basket depth – 550 mm (Minimum) (e) Door opening -400mmx310mm (Minimum) (f) Motor capacity – 7.5 HP (g) Final extraction speed – 865 RPM (h) Steam inlet – 0.5 Inches (i) Water inlet – 1.5-inch PVC spiral ribbed pipe with PP-R gate valve. (j) Drain outlet – 3 Inches PVC spiral ribbed pipe. (k) Heater – 18 kW (l) Steam pressure – 4-5 Bar (m) Steam consumption – 30 Kg/hour (n) Machine Dimensions 1650mmX1360mmX1750mm
Supply, install, testing and commissioning drying tumbler machine with front loading open pockets, Stainless steel inner basket, Auto cool down – Activates at the end of the drying program to reduce wrinkle and untangable cloths, The stainless-steel basket programmable for forward and reverse rotations to prevent garments from entangling with each other, A special radiator / heat exchanger design and efficient blower system ensures perfect drying with following specifications Programmed for Safety Program control system Emergency stop buttons and a safety limit switch SS lint collection mesh Lint Collection Mesh Dryers provided with lint meshes prior to the hot air exhaust. Steam / Electric Radiator Steam – Heat generated by passing steam through a heat exchanger / radiator Electrical – Electrical heating elements are used to heat up the heat exchanger
item No. 03 (contd....) Specifications (a) Capacity - 30 Kg (Minimum) (b) Basket Volume - 613 Ltr (Minimum) (c) Basket diameter - 970 mm (Minimum) (d) Basket depth – 830 mm (Minimum) (e) Door opening diameter - 750 mm (f) Drive Motor capacity – 1 HP (g) Exhaust Motor capacity – 1 HP (h) Steam inlet – 1 Inches (i) Condensate outlet – 1 Inches (j) Hot air outlet size 150 mmX200 mm (k) Heater – 24 KW
Notes :- For item No. 1 & 3. Quoted rates includes the following (a) PCC foundations and grouting arrangements as recommended by the OEM. (b) Complete installation, electrical and mechanical connecting as recommended by OEM, including testing in front of Eng-in-charge and accepting officer. (c) Connection from wall to machine including one PP-R valve for each machine and should make arrangements for drain outlet as per site requirement as directed by the Eng-in-charge. (i) Contractor shall provide one year warranty after completion of work including replacement of defective parts during maintenance period. (ii) Contractor shall also teach operation of machines to the user rep.
Supply and fixing industrial type plug and socket set three, phase and neutral, 05 Pin, 63 Amps, 415 V, including top and 63 Amp,, TPN MCB, 10 KA breaking capacity ‘C’ curve complete all as specified and as directed by the Engr-in-charge. Make : L & T /Seimens/Schneider
S & laying as in repair sub main wiring with four run of 16 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 16 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Five runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron strip earth lead of 25x 4mm thick size by means of bolts, nuts, check nuts and washers of galvanised iron, earth strip protected by GI pipe 32mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . Note :- Cost of GI strip 25x4 mm thick upto 7.5 mtr length shall be includied in the quoted rate.
Supply and fixing sheet metal enclosure Vertical triple pole & neutral(VTPN), 415 volts, 4 way with 200 Amp rated bus bar, IP 54 protection, double door, with and including MCCB 4 Pole, 160 Amp, 415 Volts, breaking capacity 25 KA ,Adjustable Thermal Range as incomer, flush /surface mounting duly grouted in wall or on wooden board with lugs/thimbles duly crimped for connection complete all as specified and as directed by the Engr-in-charge. Make : L&T/Schneider/Seimens
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable 50 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and as directed .
Supply and lay GI tubing light grade with connected fittings 32mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge
Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including stretching the cable, complete all as specified and as directed . Note - Punned thickness of sand layer shall be measured and paid to contractor.
Supply and laying well burnt brick class-B laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M& L for cutting the existing hard standing/PCC/WBM road depth exceeding 45 cm and 30 cm in width for passing of cable through GI pipe and making good the disturbed surface with PCC (1:3:6) type C-1 using 20mm graded stone aggregate complete all as specified and directed.
Lucky Engineering Works
Electromech Engineers
SB ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .