Tender Value
₹19.6 L
EMD Value
₹39,215
Closing Date
15 May 2023, 5:00 pmClosed
DGM ED-II,Bordowali
O/o DGM,ED-II,Bordowali
Extension of HTLT line by UG Cable ic installation of 2X63 KVA transformer for providing service connection to newly sunk water pump under DTW Scheme at Laxmipur and Duttapara under Belabar GP within the jurisdiction of ESDIII Bordowali
2023_POWER_37973_1
DGM /ED- II/2022-23/34
Open Tender
Electrical Works
Item Rate
60 days
Belabar GP
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,540
TSECL Settlement Centralised Account
₹39,215
O/o AGM , Circle-I
30 Jun 2023
3 May 2023
16 May 2023
8 May 2023
15 May 2023
8 May 2023
3 May 2023 - 6 May 2023
6 May 2023
Amount
(Supply & Erection)
Erection of 8.00 mtr. Length of Steel Tubuler Pole at any kind of soil upto a depth of 1/6th of pole height,i/c excavation of of earth, refilling the pit with soil up to the ground level,ramming and making complete in all respect
Erection of 9.0 mtr. Length of Steel Tubuler Pole at any kind of soil upto a depth of 1/6th of pole height,i/c excavation of of earth, refilling the pit with soil up to the ground level,ramming and making complete in all respect
Erection of "C" type bracket for LT -5 wire of 50x50x6mm (excluding the cost of back Clamp, Nuts & bolts)
Erection of MS Channel cross arm, 0.3 to 1.2 mtr. Long 75x40x40x6mm e(excluding the cost of back Clamp, Nuts & bolts)
Erection of MS Channel cross arm, 1.3 to 2.8 mtr. Long 75x40x40x6mm e(xcluding the cost of back Clamp, Nuts & bolts)
Erection of LT Shakle Insulator
Erection of 11KV Pin Insulator along with pin
Febrication of Cross Arm By MS Channel/MS Angle as per specification
Laying & stringing of 1KM (single Conductor) ACSR 6/1/2.59 mm dia "weasel " including hoisting & binding etc complete as required
Erection of 9KA,5KA Single pole metal oxide gapless type LA including necessary connection complete as per Technical specification.
Erection of 11KV, DOF unit set of Three nos including necessary connection complete as per Technical specification.(excluding the cost of back clamp, Nuts & Bolts)
Erection of 11KV, 200 Amp GOS unit set of Two nos including necessary connection complete as per Technical specification.(excluding the cost of back clamp, Nuts & Bolts)
Installation /positioning of 11/0.430KV, 3-Phase 63 KVA Distribution transformer on pole with necessary connection & fittings fixing of all allied accessories component as required for making complete in all respect for energizing
Carriage of 8.0/9.0 mtrs length of steel tubular pole by mechanical transport from the electrical site store to working site vis-a Vis including loading, unloading andstacking etc required. A)upto the lead range 25KM, i)beyond 8 (eight)pole
Carriage of materials such as cable, AAC,AAAC, ACSR, GI Cross Arm, Stay Set , Insulators etc by mechanical transport from the electrical site store to working site vis-a Vis including loading, unloading andstacking etc required. upto the lead range 25KM & 50 Km
Carriage of 11/.430, 3-phase 63 kVA by mechanical transport from the SITE/STORE/WORKSHOP TO WORKING SITE vis-a Vis including loading, unloading and placing on base as required. upto the lead range 25KM
Earthing with GI Pipe 2.5 mtr. Long nd 40 mm. dia with holes including excavation , Refilling with alternate layer of Salt and Charcoal as per drawing including supply of G.I pipe, Salt &charcoal, GI wire, Nuts &bolts, etc as required.
Manually digging/drilling horizentally or diagonali direction forroad crossing/Water supply line/ Telecomunication line/ Gas Pipe line etc. including laying of 64-200 mm dia GI pipe direct into earth at adepth of minimum1100 mm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineer -In-Charge.
Laying of one number PVC Insulated and PVC sheathed /XLPE Power Cable of 11KV Graded of all size in the GI Pipe /HDPE for riser including tieup of Pipe with pole by the help MS Flat Clamp and coiling of extra cable as direction of Engineer-in-charge(excluding cost of clamp and Nuts& bolts) as required i/c coiling of extra cable at pole top.
Laying of one number PVC Insulated and PVC sheathed /XLPE Power Cable of 11KV Graded of afollowing size direct in ground including excavation , sand cushioning, protective covering and refilling of trench etc as required. Trench size: width- 3500, height-1200mm/ Sand (couhioning)Height-250 mm, Width-350, protection- Double layer bricks- cable size-70sqmm
Laying of one number additional PVC Insulated and PVC sheathed /XLPE Power Cable of 11KV Graded of following size direct in ground in the same trench in one tier horizental formation including excavation , sand cushioning, protective covering and refilling of trench etc as required. Trench size: width- 200, height-1200mm/ Sand (couhioning)Height-250 mm, Width-200, protection- Double layer bricks- cable size-70sqmm
Carraige of Power cable from TSECL store or stack sites by mechanical transfort including loading, unloading and stacking/ positioning by light crane up to work site. Weight of 3-core 6.35/11KV XLPE cable, flat strip(KG/KM):70sqmm(3100Kg)
Providing of Pre-cast cement concretable identification route marker (1 cement: 2 coarse sand: 4 graded stone aggregate 6mm nominal Size) reinforced with 1.6 mm dia mild steel wire incliding centring, and Shuttering, roughening, cleaning, fixing and finishing in cement morter 1:3 (1cement:3 Fine sand) etc complete, excluding the plasteringof jambs, sills and soffits as per design , drawing and specification of TSECL. the marker shall be embossed " DANGERS TSECL, ELECTRIC POWER CABLE" with back coloure letter (both Side), the visible part shall be painted with yellow colour Japan Paint
Providing and executing cement concrete work 1:2:4 ( 1=cement, 2=river sand, 4= jhama bricks aggregate 20mm nominal Size) for grouting of steel pole/ supporting pillars excluding the cost of centering, shuttering inc. centering, shuttering and excavation in foundation trench not exceeding1.4mtr width in 10sq.mm on plan i/c dressing of side and ramming of bottom lift up to1.5mtr. width i/c getting the excavated soil and direct with in alead of 50mtr(0.273x9nos- )
Supply of Digital Earth Resistance Tester with Kit (Multicolour) make WACO DET mid insulation range 0 ohm-10 ohm- 1000 ohm
Supply of (karai) wooden Plank (2'X1'X1.5")
Supply of fabricated bracket clamps of assorted size of MS flat (50 x 6 mm) with double coat of red oxide primer coating
Supply of 1/2" dia polythin pipe
Supply of 110mm dia HDPE Pipe, wall thickness: minimum 6.5mm, maximum- 7.3mm.
Supply & making of Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 70 sq.mm , 3-Core XLPE aluminium conductor cable of 11kv Graded.
Supply of XLPE Power cable 11KV Grade 3-Core, 70sqmm
TAPAN CHOUDHURY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .