Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹6.6 Cr
EMD Value
₹6.6 L
Closing Date
5 Mar 2026, 6:05 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Mahisagar (R&B) Division, Lunawada
Construction of Children home for Girls building at Lunawada Dist. Mahisagar
278864
05 of 2025-26
Open
Civil Works - Buildings
Works
Mahisagar
2 documents required · 2 mandatory
₹12,000
Yes
Executive Engineer, Mahisagar (R&B) Division, Lunawada
₹6.6 L
Yes
20 Feb 2026
20 Feb 2026
20 Feb 2026
5 Mar 2026
20 Feb 2026
No. Figure Amount
1 Excavation for foundation upto 1.50 mt depth including sorting out and 2165.24 Cum 278.06
stacking of useful materials and disposing the excavated stuff within all lead
and lift for soft rock not requiring blasting.
2 Excavation for foundation from 1.50 mt to 3.00 mt. depth including sorting out 1074.50 Cum 651.26
and stacking of useful materials and disposing the excavated stuff within all
lead and lift for Hard rock.
3 Filling in foundation and plinth with sand in layers of 20 cm thickness 254.85 Cum 479.80
including watering, ramming and consolidating etc. complete.
thickness including watering, ramming and consolidation etc. complete.
5 Anti Termite System : P/L of Permanent piping technology Anti Termite 1250.95 Sq.m. 63.63
treatment before flooring work by installing LLDP (Low linear density
Polyethylene) tube of 8 mm O.D.& 6.4 mm I.D. with in Built Pressure
Compensation chip every 30 cm interval in the tube, having working pressure
of 2 kg/cm 2 and release rate of 1.9 ltr/Hour fixed by P-Clip and nails. The
LLDP pipe shall be installed at the entire periphery of the building and at
internal network of building depth of 20 to 200 mm under floor every 2 to
mtr. c/c distance (adjustable as per building layout) & ends of loop pass
through a PVC Elbow of minimum 32 mm ID at junction box of wall and floor
level, entering into a steel reinforced grooved flexible pipe mini. 22 mm LD
leading into junction box and during injecting chemicals for termite control
treatment.
The anti-termite chemical Lmidcloprid 30.5% SC mix as per IS 6313 (part-III)
shall be injected by the pressure pump diluted with water @ 10.5 ml/5ltr of
water at the rate of 2 kg/sq.cm. @ 5 ltr /Smt. the contractor shall submit
approved line plan for piping system and junction boxes dully approved by
Engineer-in-charge with bond of 5 years warranty. (II) Anti Termite chemical
injected area (Chemical injecting including labour cost)
6 Providing and laying controlled cement concrete M-150 and curing complete 289.60 Cum 4383.43
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Foundations and plinth for PCC.
7 Providing and laying controlled cement concrete M-250 and curing complete 513.08 Cum 4734.10
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Foundations, footings & mass concrete.
8 Providing and laying controlled cement concrete M-250 and curing complete 29.64 Cum 8053.45
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns upto plinth level.
9 Providing and laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 274.35 Cum 3092.22
machine cut stone aggregate 40 mm nominal size) and curing complete
including cost of form work in foundation and plinth.
10 Providing and laying controlled cement concrete M-200 and curing complete 67.10 Cum 8038.23
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns for Ground floor.
11 Providing and laying controlled cement concrete M-200 and curing complete 48.60 Cum 8079.77
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns for First floor.
12 Providing and laying controlled cement concrete M-200 and curing complete 24.10 Cum 8121.31
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns for Terrace floor.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
13 Providing and laying controlled cement concrete M-250 and curing complete 140.56 Cum 6398.17
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Ground beam and plinth beam.
14 Providing and laying controlled cement concrete M-150 and curing complete 189.40 Cum 4662.62
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Plinth Slab.
15 Providing and laying controlled cement concrete M-200 and curing complete 122.31 Cum 6364.82
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Beam for Ground floor.
16 Providing and laying controlled cement concrete M-200 and curing complete 112.40 Cum 6406.36
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Beam for First floor.
17 Providing and laying controlled cement concrete M-200 and curing complete 6.50 Cum 6447.90
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Beam for Terrace floor.
18 Providing and laying controlled cement concrete M-200 and curing complete 6.38 Cum 6934.10
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Chhajja for Ground floor.
19 Providing and laying controlled cement concrete M-200 and curing complete 6.10 Cum 6975.65
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Chhajja for First floor.
20 Providing and laying controlled cement concrete M-200 and curing complete 0.40 Cum 7017.19
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Chhajja for Terrace floor.
21 Providing and laying controlled cement concrete M-200 and curing complete 5.39 Cum 9021.71
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Lintel for Ground floor.
22 Providing and laying controlled cement concrete M-200 and curing complete 4.50 Cum 9063.26
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Lintel for First floor.
23 Providing and laying controlled cement concrete M-200 and curing complete 0.30 Cum 9104.80
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Lintel for Terrace floor.
24 Providing and laying controlled cement concrete M-200 and curing complete 186.87 Cum 6776.77
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Ground floor slab.
25 Providing and laying controlled cement concrete M-200 and curing complete 149.60 Cum 6818.31
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in First floor slab.
26 Providing and laying controlled cement concrete M-200 and curing complete 8.80 Cum 6859.85
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Terrace floor slab.
27 Providing and laying controlled cement concrete M-200 and curing complete 11.70 Cum 7942.27
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Staircases upto floor two level for Ground floor to
First floor.
28 Providing and laying controlled cement concrete M-200 and curing complete 6.50 Cum 7983.81
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Staircases upto floor two level for First floor to
Terrace floor.
29 Providing and laying controlled cement concrete M-200 and curing complete 22.90 Cum 5451.20
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Walls from top of foundation level upto floor two
level for Ground floor.
30 Providing and laying controlled cement concrete M-200 and curing complete 6.40 Cum 5492.74
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Walls at First floor.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
31 Providing and laying controlled cement concrete M-200 and curing complete 37.60 Cum 5534.28
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Walls at Terrace floor.
32 Providing and fixing 90 cm high Stainless steel railing made from anti 72.00 Rmt. 3719.83
corrosive 304 grade S.S. pipe of 50 mm dia. (16 gauge) as hand rail with S.S.
304 grade baluster of 38 mm dia. (16 gauge) as a vertical support fixed in
RCC slab at 1.2m c/c including three horizontal S.S. pipes of 25 mm dia. (16
gauge) at equal distance fixed by 18.75 mm dia (16 gauge) S.S. pipe with
baluster including accessories as per detailed drawing as directed etc.
33 Providing I.S.I. Mark T.M.T. bar Fe-500D reinforcement with fusion bonded 136243.55 Kg. 77.29
epoxy coating not less than 175 micron thickness and upto 300 micron to
reinforcement bars as per IS-13620-1993/ASTM-775M (including testing of
coating at plant and all taxes) for R.C.C. work including bending, binding and
placing in position complete upto floor two level for Ground floor.
34 Providing I.S.I. Mark T.M.T. bar Fe-500D reinforcement with fusion bonded 29617.00 Kg. 78.34
epoxy coating not less than 175 micron thickness and upto 300 micron to
reinforcement bars as per IS-13620-1993/ASTM-775M (including testing of
coating at plant and all taxes) for R.C.C. work including bending, binding and
placing in position complete upto floor two level for First floor level.
35 Providing I.S.I. Mark T.M.T. bar Fe-500D reinforcement with fusion bonded 14950.50 Kg. 79.39
epoxy coating not less than 175 micron thickness and upto 300 micron to
reinforcement bars as per IS-13620-1993/ASTM-775M (including testing of
coating at plant and all taxes) for R.C.C. work including bending, binding and
placing in position complete upto floor two level for Terrace floor level.
36 Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles 975.85 Sq.m. 1674.15
having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for
extra strength. The Light weight calcium silicate ceiling tiles shall have, light
reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity
resistance and also having thermal conductivity 0.043° w/m KC.for the best
thermal Insulation. The Light weight calcium Silicate tile shall be of approved
texture Fine fissured/ Spintone/ Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent of size 595 x 595 mm to be laid
on true horizontal level suspended inter locking metal grid of hot dipped
galvanized steel sections (galvanizing @120 grams per sqm including both
side) consisting of main ‘T’ runner suitably spaced at joints to get required
length and size of 24 x 38mm made from 0.30 mm thick (minimum) sheet,
1200mm centre to centre, and cross ‘T’ of size 24 x 28mm made out of
0.33mm (Minimum) sheet spaced 1200mm along spaced between main 'T' at
600mm centre to centre to form a grid of 1200 x 600mm and size 24 x 48mm made of
0.30mm thick (Minimum) sheet to be interlocked at middle of the 1200 x
600mm panel to form grid of size 600 x 600mm resting on periphery
walls/partitions on a perimeter wall angle pre-coated steel of size (24 x 24 x
3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs
at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval
and laying 15mm thick densified edges light weight calcium silicate ceiling
tiles of approved texture (Fine fissured / Cosmos / Spintone) in the grid
including cutting / making opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc., whenever required, Main 'T' runners to
be suspended from ceiling using G.I. slotted cleats of size 25 x 35 x 1.6mm
fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I.
adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8mm,
spaced at 1200mm center to centre long main 'T' bottom exposed with 24mm
of all T-sections and also provide additional frame work and
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
suspended G.I. support as required height shall be pre-painted with polyester
baked paint, for all heights, as per specifications, drawings and as directed by
engineer-in-charge. Note:- Only calcium silicate false ceiling area will be
measured from wall to wall. No deducation shall be made for exposed
frames/opening (cut outs) having area less than 0.30sqm. The calcium silicate
ceiling tiles shall fissured / Spintone / Cosmos and 0.75 NRC for Globe, light
reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity
resistance and also having thermal conductivity. 0.043 w/m KC for the best
thermal Insulation.
37 Providing and laying brick work using common burnt clay building 217.15 Cum 4214.33
conventional type bricks having crushing strength not less than 35 Kg./Sq.cm.
in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand)
including the cost of all materials and labour charges etc. complete.
38 Providing and laying brick work using common burnt clay building 527.81 Cum 4496.05
conventional type bricks having crushing strength not less than 35 Kg/sq.cm.
in super structure above plinth level upto floor two level in cement mortar 1:6
(1 cement : 6 fine sand) for Ground Floor including the cost of all materials
and labour charges etc. complete.
39 Providing and laying brick work using common burnt clay building 192.15 Cum 4538.16
conventional type bricks having crushing strength not less than 35 Kg/sq.cm.
in super structure above plinth level upto floor two level in cement mortar 1:6
(1 cement : 6 fine sand) for First Floor including the cost of all materials and
labour charges etc. complete.
40 Providing and laying brick work using common burnt clay building 37.10 Cum 4580.28
conventional type bricks having crushing strength not less than 35 Kg/sq.cm.
in super structure above plinth level upto floor two level in cement mortar 1:6
(1 cement : 6 fine sand) for Terrace Floor including the cost of all materials
and labour charges etc. complete.
41 Providing and laying half brick work using common burnt clay building 301.80 Sq.m. 681.56
conventional type bricks having crushing strength not less than 35 Kg/Sq.cm
in cement mortar 1:4 (1 cement : 4 coarse sand) in cement mortar in super
structure for Ground floor including the cost of all materials and labour
charges etc. complete.
42 Providing and laying half brick work using common burnt clay building 289.20 Sq.m. 690.57
conventional type bricks having crushing strength not less than 35 Kg/Sq.cm
in cement mortar 1:4 (1 cement : 4 coarse sand) in cement mortar in super
structure for First floor including the cost of all materials and labour charges
etc. complete.
43 Providing and fixing 150 mm wide, approved quality chicken wire mesh at 4722.20 Sq.m. 6.00
junction of brick work and RCC work or two dissimilar surfaces, at all heights
fixed by nails, rowal plugs or tag by cement mortar 1:3 before applying the
plaster, including curing etc. complete
44 Providing 15mm thick cement plaster in single coat on rough (similar) side of 2806.10 Sq.m. 226.01
single or half brick walls / concrete wall for interior plastering and finished
even and smooth along with floating coat of neat cement slurry etc. complete
in Cement mortar 1:4 (1-cement : 4 sand) at Ground floor.
45 Providing 15mm thick cement plaster in single coat on rough (similar) side of 2545.20 Sq.m. 249.90
single or half brick walls / concrete wall for interior plastering and finished
even and smooth along with floating coat of neat cement slurry etc. complete
in Cement mortar 1:4 (1-cement : 4 sand) at First floor.
46 Providing 15mm thick cement plaster in single coat on rough (similar) side of 139.85 Sq.m. 273.80
single or half brick walls / concrete wall for interior plastering and finished
even and smooth along with floating coat of neat cement slurry etc. complete
in Cement mortar 1:4 (1-cement : 4 sand) at Terrace floor.
47 Providing 10 mm. thick smooth cement plaster in single coat for plastering on 1351.65 Sq.m. 208.97
ceiling and soffits of stairs and finished even and smooth along floating coat
of neat cement slurry in cement mortar 1:4 (1 cement : 4 sand) (1) Plaster at
Ground floor.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
48 Providing 10 mm. thick smooth cement plaster in single coat for plastering on 1182.10 Sq.m. 230.86
ceiling and soffits of stairs and finished even and smooth along floating coat
of neat cement slurry in cement mortar 1:4 (1 cement : 4 sand) (1) Plaster at
First floor.
49 Providing 10 mm. thick smooth cement plaster in single coat for plastering on 28.00 Sq.m. 252.74
ceiling and soffits of stairs and finished even and smooth along floating coat
of neat cement slurry in cement mortar 1:4 (1 cement : 4 sand) (1) Plaster at
Terrace floor.
50 Providing 20mm thick double coat sand faced cement gutka plaster on walls 4315.01 Sq.m. 345.75
with 1 x 1 cm grooves consisting of 12 mm thick backing coat of C.M. 1:3 (1
cement : 3 sand) and 8 mm thick finishing coat of C.M. 1:1 (1 cement :
sand) including 1 cm x 1 cm grooves etc. complete as directed by Engineer-in-
51 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 167.65 Rmt. 43.05
52 Applying two coats of acrylic lappy - putty & two coats of primer of approved 7895.28 Sq.m. 40.59
brand and manufacture on new wall surface to give an even shade including
thoroughly brushing the surface free from mortar dropping and other foreign
matter and sand papered smooth for all floors.
53 Wall painting (two coats) with plastic emulsion paint of approved brand and 5419.53 Sq.m. 82.85
manufacture on undecorated wall surfaces to give an even shade including
thoroughly brushing the surface free from mortar droppings and other foreign
matter and sand papered smooth for all floors.
54 Wall painting (two coats) with plastic emulsion paint of approved brand and 2475.75 Sq.m. 88.38
manufacture on undecorated ceiling surface to give an even shade including
thoroughly brushing the surface free from mortar droppings and other foreign
matter and sand papered smooth for all floors.
55 Finishing wall with weather proof exterior 100% acrylic emulsion paint with 5061.01 Sq.m. 120.26
one coat of primer on wall surface to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, dust and remains of loose
powdered materials etc. complete for all floors.
56 Providing and filling with good quality sinder (steam coal) as directed by 39.15 Cum 572.06
engineer in charge in sunks in layers of 15 cm thick including watering,
placing, ramming well etc. as directed for all floors.
57 Providing and laying controlled cement concrete M-200 for R.C.C. work and 19.15 Cum 5970.26
curing complete including the cost of form work but excluding cost of
reinforcement for reinforced concrete work in coping on Ground floor.
58 Providing and laying controlled cement concrete M-200 for R.C.C. work and 8.70 Cum 6011.80
curing complete including the cost of form work but excluding cost of
reinforcement for reinforced concrete work in coping on First floor.
59 Providing and laying controlled cement concrete M-200 for R.C.C. work and 6.30 Cum 6053.34
curing complete including the cost of form work but excluding cost of
reinforcement for reinforced concrete work in coping on Second floor.
60 Providing and fixing 35mm thick solid core wooden flush double shutter 58.80 Sq.m. 3681.81
confirming to IS:2202 & ISI approved manufacturer, finished with 1mm thick
laminates on both sides of shutter, machine glued PVC beading on periphery,
S. S. handles and S. S. fixtures & locking arrangement of standard make of
kich or equivalent, on each shutter, fixed with minimum 4 Nos. 150mm high
S.S. hinges. Sample & shade to be approved by the Architect. Door: D1, D3 &
61 Providing and fixing 35mm thick solid core wooden flush shutter confirming to 122.15 Sq.m. 4848.84
IS:2202 & ISI approved manufacturer, finished with 1mm thick laminates on
both sides of shutter, machine glued PVC beading on periphery, S. S.
handles and S. S. fixtures & locking arrangement of standard make of kich or
equivalent, on each shutter, fixed with minimum 4 Nos. 150mm high S.S.
hinges. Sample & shade to be approved by the Architect. Door: D2 & D5.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
62 Providing and fixing window having two shutter glass section and one shutter 143.45 Sq.m. 2597.98
mosquito net extruded colour anodized aluminum section equivalent to Jindal
series E(30 mm) with sections numbered : frame bottom with weep holes-
20737, frame top & side - 20738; shutter top & bottom- 20993, shutter-inter
lock - 20550, shutter side (handle) - 20549, with 5 mm thick transparent tinted
float glass, with rubber gasket, air lock strip and finishing joints with
transparent silicon sealant, with standard extruded colour anodized aluminum
fittings. Window W1, W2 & W3.
63 Providing and fixing standard extruded colour anodized aluminum sections, 68.50 Sq.m. 683.12
with 5mm thick transparent tinted float glass, with rubber gasket, finishing
joints with transparent silicon sealant on both sides. For Fixed Glass.
64 Providing & fixing in position standard extruded approved colour anodized 11.25 Sq.m. 3944.65
Alluminum Ventilator with 3mm thick Bajari figure adjustable tinted louvers
glass fixed to alluminium strip blade including fixtures, fastening, labours and
equipments as per detailed drawing as directed. For Ventilators V1, V2.
65 Providing and laying Machine cut, free edges, mirror polished Granite Slab 112.75 Sq.m. 2368.24
flooring over 18mm (Average) thick base of cement mortar 1:6 (1-cement : 6-
coarse sand) laid over and jointed with grey cement slurry mixed with pigment
to match the shade of slab including rubbing and polishing etc. complete. (A)
18mm thick.
66 Providing and laying machine cut, free edges, mirror polished Granite Slab 33.95 Sq.m. 2338.22
18mm thick in risers of steps, skirting, dedo and pillars laid on 10mm thick
cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement
slury mixed with pigment to match the shade of slab including rubbing and
polishing etc. complete.
67 Providing and laying 24" x 24" Vitrified 8 mm thick tiles flooring over 20mm 392.30 Sq.m. 1467.72
(average) base of cement mortar 1:6 (1 cement : 6 coarse sand) on new
surface or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement slurry including
finished with flush pointing & cleaning the surface etc. complete for Anti skid.
68 Providing and laying Vitrified tiles 8 to 10 mm thick, 24'' x 24'' in skirting, risers 32.90 Sq.m. 1592.40
of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse
sand) and jointed with white cement slurry.
69 Providing and laying Vitrified tiles 8 to 10mm thick, 24" x 24'' in flooring treads 943.00 Sq.m. 1120.36
of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3 coarse sand) finishing with flush pointing in white cement. Pattern,
Colour & Shade approved by Architect or Engineer in charge.
70 Providing and laying Soluble Salt Vitrified tiles 8 to 10mm thick, 24" x 24'' in 181.75 Sq.m. 1195.02
flooring treads of steps and landing laid on a bed of 12mm thick cement
mortar 1:3 (1-cement : 3 coarse sand) finishing with flush pointing in white
cement. Pattern, Colour & Shade approved by Architect or Engineer in
71 Providing and laying Anti skid Ceramic tiles 8mm to 10mm thick, 30cm x 149.40 Sq.m. 1195.54
30cm in flooring treads of steps and landing laid on a bed of 12 mm thick
cement mortar 1:3 (1 cement : 3 coarse sand) finishing with flush pointing in
white cement. Pattern, Colour & Shade approved by Architect or Engineer in
72 Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and 731.55 Sq.m. 1045.60
landing laid on a bed of 12 mm thick cement mortar 1:3 (1 cement : 3 coarse
sand) finishing with flush pointing in white cement.
73 Providing and laying machine cut Kota stone slab flooring over 20mm 242.60 Sq.m. 1019.39
(average) thick base of cement mortar 1:6 (1-cement : 6 coarse sand) or L.M.
1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement
slurry mixed with pigment to match the shade of slab including rubbing and
polishing etc. complete. (A) 25mm thick.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
74 Providing Plinth Protection to building including excavation and laying cement 323.05 Sq.m. 2520.98
concrete 1:3:6 using stone aggregates of 40mm nominal size in foundation
layer 150 mm thick+ 125mm thick sand layer below pre-cast rubber dye inter
locking concrete block 60mm thick with grade of concrete M-300 pneumatic
compressed by mechanically pressed and as per approved design including
75mm sand layer for levelling and filling the joint with sand in proper line and
level etc. complete including providing and fixing precast concrete kerb stone
of grey cement based concrete block 30cm length, 30cm height and 15cm
thick made of M-250 grade concrete as per approved design and including
excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1
cement : 3 fine sand) etc. complete.
75 Providing and laying broken china mosaic flooring for terrace using 12 mm to 1198.75 Sq.m. 779.70
20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain
or slope and to be tempered to bring mortar creme out upto surface using
white cement including rounding off junctions and extending them upto 15 cm
along the wall, clearing with water and oxalic acid etc. as directed.
76 Providing and laying cement concrete flooring 1:2:4 (1 cement : 2 coarse 1198.75 Sq.m. 347.42
sand : 4 graded stone aggregate 20mm nominal size) laid in one layer and
finished with a floating coat of neat cement. (B) 50 mm thick.
77 Providing and fixing mirror polished 18mm thick Granite with full round edge 310.90 Sq.m. 2553.90
and polished of approved quality in cladding on sill and around the doors /
windows / ventilation with 20 mm thick cement plaster CM (1:4) and fixing with
cement slurry & adhesive including moulding of exposed edges as directed by
engineering in charge etc. complete.
78 Providing and fixing M.S. Grills of required pattern to frames of windows etc. 265.95 Sq.m. 3095.77
with M. S. flats at required spacings and frame alround having min. weight of
grill 25 kg/sq.m, square or round bars with round headed bolts and nuts or by
screws including priming coat of approved quality and two coats of enamel
paint, as directed by engineer in charge (A) Plain grill.
79 Providing, erecting and fixing double coated I.S.I. Mark P.V.C. water tank of 25000.00 Litre 3.95
required capacity each with all necessary fittings and connection etc.
complete on terrace as directed.
80 Providing, laying and jointing in true line and level I.S.I. mark 110mm dia. 870.50 Rmt. 876.90
U.P.V.C. pipe (Type B) confirming to IS 13592-1992 with one end plain and
other end socketed with rubbering & fitting conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of
the size 110 mm diameter x 149 mm length x 145 mm height at every
mm center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
81 Providing, laying and jointing in true line and level I.S.I. mark 160mm dia. 390.00 Rmt. 834.38
U.P.V.C. pipe (Type B) confirming to IS 13592-1992 with one end plain and
other end socketed with rubbering & fitting conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of
the size 160 mm diameter x 210 mm length x 196 mm height at every
mm center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
82 Providing, laying and jointing in true line and level I.S.I. mark 50mm dia. 520.00 Rmt. 195.67
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
83 Providing, laying and jointing in true line and level I.S.I. mark 40mm dia. 258.00 Rmt. 148.12
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
84 Providing, laying and jointing in true line and level I.S.I. mark 25mm dia. 226.00 Rmt. 91.84
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
85 Providing, laying and jointing in true line and level I.S.I. mark 15mm dia. 190.00 Rmt. 72.65
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
86 Providing and fixing concealed center point to wall ceiling & floor I.S.I. mark 240.00 Rmt. 447.72
C.P.V.C. (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal
for potable water of following dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and floor etc. complete. (E) 40mm dia.
87 Providing and fixing concealed center point to wall ceiling & floor I.S.I. mark 270.00 Rmt. 253.82
C.P.V.C. (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal
for potable water of following dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and floor etc. complete. (C) 25mm dia.
88 Providing and fixing concealed center point to wall ceiling & floor I.S.I. mark 217.00 Rmt. 170.36
C.P.V.C. (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal
for potable water of following dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and floor etc. complete. (A) 15mm dia.
89 Providing and laying (to level or slopes) and jointing reinforced concrete light 325.00 Rmt. 678.02
duty non pressure pipes I.S. Class NP-2 of the following internal diameter with
collars and butt ends prepared for collar joints including testing of joints
complete. (D) 300mm dia.
90 Providing, laying and jointing in true line and level I.S.I. mark 75mm dia. 180.00 Rmt. 756.22
U.P.V.C. SWR Type B pipe confirming to IS 13592-1992 with one end plain
and other end socketed with rubbering and fitting conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be jointed
with each other with rubber lubricant, pipe shall be fixed on wall using of PVC
clamp at every 2000 mm c/c or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of all
materials.
91 Providing and fixing cast iron spigot and socket soil, waste and ventilating 16.00 No. 741.01
pipes of the following nominal size. (B) 75mm dia.
92 Providing and fixing cast iron spigot and socket soil, waste and ventilating 24.00 No. 892.39
pipes of the following nominal size. (C) 100mm dia.
93 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm 43.00 No. 586.27
diameter with jali of the following nominal diameter of self cleaning design
with C.I. screwed down or hinged grating including the cost of cutting and
making good the walls.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
94 Providing and fixing wash down water closet (European type W.C. pan) with 13.00 No. 3631.34
integral P and trap including jointing the trap with soil pipe in cement mortar
1:1 (1 cement : 1 fine sand) including providing and fixing plastic seat cover
for wash down WC with CP brass hinges and rubber buffers back plastic seat
and including providing and fixing PVC flushing tank with a pair of C.I. or M.S.
bracket with complete fitting such as lead valve siphon 15 mm dia. brass ball
valve with polythene float C.P. brass handle unions and couplings for
connection with inlet out let and over flow pipes 40 mm dia. porcelain
enameled flush bend including cutting holes in walls and making good the
same connection the flush bend with cistern and closet vitreous china etc.
completed.
95 Provision, supplying and fixing white vitreous china W.C. squatting pan Orrisa 6.00 No. 1638.03
type 580 x 400 size with 100mm P or S trap, 25mm dia. C.P. Brass flush valve
and G.I. inlet connection etc. complete. (A) Vitreous china long pattern white
96 Providing and fixing brass screw down stop tap. (A) 15mm dia. as approved 38.00 Each 205.83
by Engineer in charge.
97 Providing and fixing ball cock of approved quality as directed. (A) Copper 7.00 Each 189.84
Metal (iv) 50mm dia.
98 Providing and fixing wash basin with single hole for pillar tap with C.I. or M.S. 26.00 Each 1451.48
brackets painted white including sutting holes and making good the same but
excluding fittings. (A) Vitreous China (ii) Flat Back washbasin 550 mm x
400mm size. (i) In white colour.
99 Providing and fixing C. P. brass waste for wash basin or sink. (A) 32mm dia. 26.00 Each 67.91
100 Providing and fixing M.I. fisher union for washbasin or sink. (A) 32mm dia. 26.00 Each 78.75
101 Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass 13.00 Each 859.41
mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden plug
with C.P. brass screws and washers.
102 Providing and fixing C.P. brass towel rail complete with C.P. brass brackets 13.00 Each 616.42
fixed to wooden plugs with C.P. brass scews (B) 600mm x 20mm size.
103 Providing and fixing screw down bib taps of following size.(A) Brass screw 27.00 Each 214.81
down bib tap polished bright. (ii) 20mm dia. as approved by Engineer in
104 Providing and fixing pillar tap, capstan head, screw down high pressure with 27.00 Each 308.73
screws, shanks and back nuts. (i) 15mm dia. as approved by Engineer in
105 Providing and fixing in position 300 mm high, 300 mm wide English / Gujarati 30.00 Each 707.00
letters made from 1.0 mm thick stainless sheet as directed by Engineer-in-
charge with all necessary tools & plants etc. complete.
106 Providing and fixing Urinal of approved quality including connection with trap 2.00 Each 1635.22
and with integral longitudinal flush pipe. (A) Squatting plate pattern white
earthenware 550mm x 300mm.
107 Providing and fixing Rubber plug for sink or wash basin. 27.00 Each 17.15
108 Providing and fixing chromium plated brass half turn flush cock of approved 14.00 Each 263.77
quality including fixing in pipe line etc. complete (ii) 25mm dia.
109 Providing and fixing S.W. Gully trap with C.I. grating brick masonry chamber 17.00 Each 1246.92
and water tight C.I. cover with frame of 300 x 300 mm size (inside) with
standard weight (i) square mouth traps (B) 150 mm x 100 mm size P or R
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
110 Constructing brick masonry chamber for underground C.I. Inspection chamber 22.00 Each 2932.93
and bends with bricks having crushing strength not less than 35 Kg/cm2 in
C.M. 1:5 C.I. cover with frame (light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab with 1:2:4 mix (1-
cement : 2 coarse sand : 4 graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete. (i) Inside dimensions 455mmx 610mm and 450mm deep for single
pipe line.
111 Constructing brick masonry chamber for underground C.I. Inspection chamber 17.00 Each 3660.76
and bends with bricks having crushing strength not less than 35Kg/Cm2 in
C.M. 1:5 C.I. cover with frame (light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab with 1:2:4 mix (1-
cement : 2 coarse sand : 4 graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete. (ii) Inside dimensions 500mm x 700 mm and 450mm deep for pipe
line with one or two inlets.
112 Providing cement vata (10cm x 10cm size) quarter round in cement mortar 1:1 221.80 Rmt. 24.28
including neat cement finishing watering etc. complete.
113 Providing and fixing in position collapsible steel shutters with vertical channels 8.40 Qtl. 6076.50
20 x 10 x 2 mm braced with flat iron diagonals 20 x 5 mm size with top and
bottom rails of T_rin 40x 40 x 6 mm with 38mm dia, steel pulleys complete
with bolts, nuts, locking arrangements, stoppers, handles including applying a
priming coat of red lead paint.
114 Providing and fixing in position 150 mm high, English letters made from 1.0 30.00 Each 404.00
mm thick stainless steel sheet as directed by Engineer in charge with all
necessary tools & plants etc. complete.
115 Providing and fixing polished 18 mm thick black granite with full round edge 5.10 Sq.m. 2719.93
and double side polished of approved quality in between urinal and fixing with
cement slurry & adhesive including moulding of both exposed edges as
directed by engineering in charge etc. complete.
116 Constructing platform of 18mm thick Polished Black Granite at top and 25mm 14.65 Sq.m. 4362.19
thick Kota stone slab one side polished at bottom with cementing materials /
adhesives including making necessary grooves in walls with Vertical Kota
stone (25mm thick) support of height 0.70m every 60 cm center to center or
as required including one Kitchen sink and all labor material of approved
quality including full moulded round front edge granite strip of one side
polished and jointed with grey cement slurry including rubbing and polishing
etc. complete for all floors.
117 Providing & fixing 114mm wide G.I. Sheets louvers having weight not less 82.10 Sq.m. 7824.47
than 490 Gm/m roll formed to create 84mm wide louver snap fixed on special
shaped GI channel. Fix louvers & channels shall finished with powder coating
of 55 micron (1) 0.55mm thick sheet etc. complete as per detail drawing as
118 Providing and fixing 0.45 meter wide Drinking platform including supplying 4.70 Sq.m. 3038.08
and fixing granite stone of black or equivalent quality 18 mm thick mirror
polished on top and side position and vertical strip at front with cement slurry
& adhesive including moulding of both exposed edges over 25 mm thick kotah
stone platform fixing in top and sides and intermediates supports fixing with
cement mortar and adhesive and finishing all material and labour and
accessories with necessary fitting complete etc.
119 Providing and fixing Cement Fiber Sheet with CNC cutting in standard 57.30 Sq.m. 4236.92
extruded of alluminium colour anodized section frame main outer pipe centre
to centre pipe 75cm of size 50 x 38.10 x 1.95 mm (of @ Wt 0.643 Kg/Rmt)
detail drawing and as directed by Engineer in charge.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
120 This includes all necessary laser and CNC work, along with a wooden finish 9.50 Sq.m. 9524.30
back board including all materials, scaffolding, labor, 15mm stainless steel
studs for mounting and other hardware, as well as accounting for waste
materials. The work should be completed satisfactorily in accordance with the
instructions of the architect or engineer in charge. Basic Size of Name plate:
121 Clearing and grubbing road land including uprooting rank vegetation grass 0.40 Hect. 28455.09
bushes, shrubs, sapling and trees girth up to 300 mm removal of stumps of
trees cut earlier and disposal of unserviceable materials (C) By mechanical
means in area of light jungle.
122 Earthwork in cutting including preparing the slope, camber and stacking or 13371.00 Cum 317.35
utilising the cutting stuff in bank as directed upto 200 meters from the end of
cutting with all lead and lift. (ii) Soft rock not requiring blasting.
123 Providing and laying coloured glazed tiles of the size 300 mm x 200 mm x 8 96.40 Sq.m. 1488.24
mm / 300 mm x 450 mm x 8 mm in skirting, risers of steps and dedo on
mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with white
cement slurry.
124 Providing and fixing to wall, ceiling and floor galvanized mild steel tubes 50.00 Rmt. 608.35
(medium grade) of the following nominal bore, tube fittings and clamps
including making good the wall, ceiling and floor (F) 40mm dia.
125 Providing & laying weep hole in abutments and returns by using A.C. pipe of 256.00 Each 86.73
100mm including laying in proper grade and jointing the completed as per
detailed specification.
126 Providing and fixing 610mm dia. Barbed Razor Tape Concertina Coil made 260.00 Rmt. 258.58
from hot dip galvanized spring steel high tensile wire (UTS: 145-160Kg/Cm2,
Zncoating 250-300g/m2, Diameter- 2.59+/-0.05mm), with blade of galvanized
Iron of 0.50 mm thick and width 19mm, with coverage / openable length of
10mtr/coil, including providing and fixing with clips, wires, bolt set con M.S.
angle posts, with all materials, labour, tools, tackles, etc. as per direction of
Engineer In-charge, for work at all level.
127 Box cutting the road surface to proper slop and camber for making a base of 254.50 Cum 109.41
road work including removing the excavated stuff and depositing on the road
side slope as directed for all lead and lift.
128 Providing and laying compacted WBM of Grading-II MCBT metal of size 45 to 90.00 Cum 1851.33
63mm in required layers including using 13% stone screening, 13.2mm size
and 7% stone dust as filler including spreading, watering & consolidation by
vibratory roller etc. complete.
129 Providing and laying controlled cement concrete M-200 and curing complete 127.00 Cum 4204.41
including the cost of formwork and excluding reinforcement for reinforced
concrete work in (A) Foundations, footings and Mass concrete.
130 Compaction and finishing of cement concrete road by trimix process providing 566.00 Sq.m. 65.65
extra labour charges for the trimix vacume dewatering service process on
cement concrete road surface by using vacuum dewatering pump floater
surface vibrator including making grooves and rough finish to surface
including leveling etc. complete.
131 Providing and laying homogeneous grey cement based concrete kerbing of 208.00 Rmt. 374.92
size 30 cm x 30 cm x 10 cm size as per detailed drawing having grade of
concrete M-25 grade, including necessary excavation, BBCC 1:5:10, 7.5 cm
as per detailed drawing fixing in line and level, filling joints in C.M. 1:3 with
smooth finished, white washing three coats etc. complete as directed by
Engineer in charge.
132 Supplying premoulded bituminous joint filler 12 mm thick. 13.00 Sq.m. 553.79
133 Providing, laying (to level or slopes) and jointing reinforced concrete light duty 30.00 Rmt. 659.99
non-pressure pipes I.S. class NP3 of the following internal diameter with
collars and butt ends prepared for collar joints including testing of joints
complete. (i) 300mm
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
134 Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8 32.00 Cum 2766.67
hand broken stone aggregates 40 mm nominal size) and curing complete
excluding cost of formwork in (A) Foundation and Plinth
135 Steel work, welded in built up sections framed work including cutting, hoisting, 4208.50 Kg. 91.08
fixing in position and applying a priming coat of red lead paint & two coat oil
paint. (A) In beams and joists, channels angles Tees, flats, with connecting
plates or angle cleats as in main and cross beams. Hip and jack rafters,
purlins connected to common rafters and the like.
136 Providing corrugated double coated trafford sheet roofing fixed with 181.00 Sq.m. 1022.80
glavanished iron J or L hooks, bolts and nuts 8mm diameter with bitumen and
G.I. limpet washer or G.I. limpet washer filled with white lead complete
excluding the cost of purlins, rafters and trusses. (1) 0.80 mm thick sheet.
137 Providing and fixing precast Rubber Dye / steel dye inter locking concrete 161.50 Sq.m. 706.77
block 60mm thick with grade of concrete M-300 pneumatic compressed /
vibrated mechanically and as per approved design confirming to IS 15658 :
2006 including 35 mm sand layer for levelling and filling the joint with sand in
proper line and level as per guidlines of IRC : SP 63-2018 etc. complete.
138 Providing and laying cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- 2.56 Cum 4089.10
graded stone aggregates 20 mm nominal size) and curing complete excluding
cost of formwork in foundation and plinth.
139 Filling available excavated earth (excluding rock) in trenches plinth side of 2.88 Cum 136.92
foundation etc. in layer not exceeding 20 cm in depth consolidation each
deposited layer by ramming and watering etc. complete.
140 Providing 15mm thick cement plaster in single coat on rough (similar) side of 37.38 Sq.m. 247.71
single or half brick walls for interior plastering upto floor two level and finished
even and smooth in Cement mortar 1:3 (1 cement : 3 sand) and finishing with
a floating coat of neat cement slurry.
141 Providing 15mm thick cement plaster in single coat on brick/concrete walls for 16.00 Sq.m. 273.77
interior plastering upto floor two level and finished even and smooth in cement
mortar 1:3 (1 cement : 3 sand) plastering on ceilings and soffits of stairs upto
floor two level instead of plastering on walls finishing with a floating coat of
neat cement slurry.
142 Providing and laying polished kota stone slab 25mm thick in risers of steps, 1.80 Sq.m. 1177.56
skirting, dedo and pillars laid on 10mm thick cement mortar 1:3 (1-Cement :
coarse sand) and jointed with gray cement slurry mixed with pigment to match
the shade of slab including rubbing and polishing etc. complete.
143 Providing and fixing window having extruded aluminum colour anodized 3.60 Sq.m. 1713.70
section frame main outer size 63.50 x 38.10 x 1.95 mm, @ Wt 1.094 Kg /
Rmt, horizontal two track member size 61.85 mm x 31.75 mm x 1.20mm @
wt.of 0.695 Kg/mt, vertical member of size 61.85 mm x 31.75mm x 1.30 mm
@ wt.of 0.659 Kg/mt with sliding shutters of horizontal member size 40mm x
18mm x 1.29mm @ wt.of 0.456 Kg/mt, vertical member of size 40mm x 18mm
x 1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm thick
transparent bronze colour tinted float glass with powder coated aluminum
fittings and fixtures and transparent silicon sealant glass fixing to frame as per
details etc. complete for window.
144 Drilling of pilot bore hole of size 250 / 300 mm diameter at above site by mud 150.00 Mtr. 865.57
finish direct rotary rig etc. complete.
145 Reaming of 250 / 300 mm diameter pilot bore hole to size 450 mm diameter 150.00 Mtr. 398.95
including assembling, lowering housing, casing strainer pipes with gravel
packing and clay ball packing etc. complete.
146 Providing 600 CFM / 150 PSI capacity air compressor up to availability of 1.00 Job 22427.05
sand free discharge (Minimum 6.0 Hours)
147 Supply of reducer made from 6 mm thick plate (M.S.) for ERW pipe of size (ii) 1.00 No. 1884.27
200 mm dia. x 250 mm dia. x 600 mm length
148 Supply of 200 mm diameter V-wire screen pipe of slot size 1.0 mm nominal 12.00 Mtr. 1767.28
hole etc. complete
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
149 Supply of M.S. bore clamps with 3 holes on either side with nuts and bolts of 1.00 Pair 1643.99
standard make and suitable size (g) 750mm x 75 mm x 16 mm flat to 200 mm
dia. pipe.
150 Supply of Bore Plug having 100 mm height made from M.S. plate with 3 holes 1.00 No. 782.57
at equal distance on circumference for nut- bolts type, locking arrangement
with nut- bolts & lock nuts of standard make complete. (B) from 5 mm thick
M.S. plate (for top also) (ii) suitable for 200 mm dia. pipe.
151 Supply of M.S. Bail Plug having length of 0.45 mtr from medium class pipe as 1.00 No. 851.04
per I.S.S. suitable for (d) 200 mm diameter pipe etc. complete.
152 Supply of Steel Bent plates suitable to ERW pipe for (b) 200 mm diameter 4.00 No. 67.26
and 150 x 150 x 6 mm size etc. complete.
filling etc. complete.
154 Charges for uptron make Electrologger (with carting) of pilot bore hole etc. 1.00 Hour 12120.00
155 Charges for Geo Hydrological ground water investigation including water 1.00 Job 14428.86
sample chemical analysis etc. complete.
156 Supplying submersible pump set suitable for bore of 150 mm. dia. or more 1.00 Each 35590.38
having three phase motor capacity not more than 7.5 H.P. with following
capacity (a) (12 stage) 280 to 240 LPM discharge at 90 to 104 mtrs. head
respectively suitable for 50mm dia. delivery pipe
157 Providing and erecting PVC corrugated flexible conduit with required numbers 125.00 Mtr. 26.26
of coupling, PVC bushes, Check nuts etc. complete of following sizes. (3)
mm diameter.
158 Lowering of submersible motor pump set complete with required. Nos. and 1.00 Job 2568.43
size of casing pipes erected by means of proper chain pulley block & pipe
wrenches after checking of threads of each pipe with coupling to take the load
of the pump set and pipe assembly filled up with water. (b) Above 60 Mtr and
up to 120 Mtr
159 Supplying and erecting approved make motor control cubical panel (Direct - 1.00 Each 8710.24
on - line) made from 16 G. CRCA sheet duly epoxy powder painted inside and
outside with hinged doors and locking, arrangement consisting of suitable size
of ON-OFF isolator (AC - 3/23 duty) main fuses, single phasing preventer,
indicating lamps for R - Y - B phases, overload relay, automatic water level
wires duly socket crimped, main contactor & overload relay, start - stop push
buttons, to be erected on angle iron frame grouted on wall as directed. The
isolator, overload relay & contactors will be of L & T, Siemens or BCH make
only. (a) DOL up to 7.50 H.P.
160 Supplying and erecting XLPE (IS: 7098) (I)-88 ISI unarmoured copper cable 140.00 Mtr. 130.29
1.1 KV grade to be erected as directed of following size. (E) 3 core
161 Providing and supplying ISI mark CI D/F Butterfly Valves as per IS:13095 1.00 No. 1868.50
(Latest Edition) of following class and diameter including all taxes, insurance,
transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete. (B) Butterfly
valves IS 13095 with ISI mark PN 1.6 (1) 50mm
162 Providing & laying Rain Water Junction Chamber of clear internal size 0.60 x 20.00 No. 7514.23
0.60 x 0.75m with excavation of size 1.36 x 1.36 m & 0.15m thick M-200 bed
concrete including brick masonary 0.23 thick wall in C.M. 1:6 of 0.75m height
with 15mm thick cement plaster inside & outside (1:4), 1.06 x 1.06 RCC M-
200 top slab of thickness 0.15m with TMT steel and 455mm x 610mm cast
iron manhole cover with frame weight not less than 35 kg as per directed by
Engineer-in-charge.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
163 Providing & laying Filter chamber of brick work 0.23 thick in C:M 1:6 of clear 2.00 No. 25919.35
internal size 2.04 mx 1.20 m x 1.20m and excavation dimension of 2.80m x
1.96 x 1.35m including C.C. M-200 bed concrete of 0.15m thick and RCC M-
200 top slab of thickness 0.15m with TMT steel, including 15mm (1:4) thick
cement plaster inside & outside with cement slurry & top cover with frame of
minimum weight of 35 kg. including filling filter material of 200mm thick each
layer of 25-40mm, 10-20mm of B.T. metal and Sand as per directed by
Engineer-in-charge.
164 Providing & laying Water harvesting pit of clear size 2.00 mt x 2.00mt x 4.00 1.00 No. 30055.01
mt. for water logging with excavation in any strata upto four meter depth, brick
work 0.23 thick in C:M 1:6 of clear internal Size 2.00 m x 2.00 m x 1.20m with
15mm thick C:M 1:4 plaster, filling the pit with B.T. Metal 40 mm in 0.60 mt.
depth with 25-40mm kapachi, 0.30 mt. depth and 2.0 mt. depth with coarse
sand in layers including making P.V.C. line for water inlet etc. as directed with
250mm dia bore 15 mt. depth and 150mm dia P.V.C. pipe of 10 Kg.f/Cm2
casing with gravel packing or as directed.
165 Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following 29.00 Each 8671.86
capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete. [B] For 5.5 / 6.5 Kg. capacity.
166 Supplying & erecting ABC powder type 'Ceasefire' type Fire extinguisher as 29.00 Each 848.40
per IS 13849 or 1 Kg capacity with necessary clamp for erection on wall.
Electrical Items
167 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm 469.00 Pt 485.81
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth continuity of following
type, erected on PVC / Metallic / Wooden box, single mounting base frame
covered with textured / metallic / white front plate modules erected on / in wall
/ ceiling as per pipe erected, with necessary Lamp holder / ceiling rose / H.D.
Connector as directed.(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
(f) with medium class Rigid PVC pipe and accessories erected concealed in 9.00 Pt 242.91
wall / ceiling complete Cat. III (Half Point for Bathroom and WC)
168 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both 181.00 Pt 674.68
are of ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected with 6A Modular type
switch and hum free EME step type electronic fan regulator mounted and
accessories with earth continuity of following type erected on PVC / Metallic /
Wooden box, single mounting base frame covered with textured / metallic /
white front plate modules erected on / in wall / ceiling as per pipe erected with
necessary ceiling rose / H.D.Connector as directed. (f) with medium class
Rigid PVC pipe and accessories erected concealed in wall / ceiling complete
169 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both 91.00 Pt 510.05
are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic / Wooden box covered
with appropriate front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [I] For 6A Plug and 6 a switch with
2-1.5 sq.mm Cu. Wire from nearby switch board/mcb db board (f) with
medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db 18.00 Pt 745.38
board. (f) with medium class Rigid PVC pipe and accessories erected
concealed in wall/ceiling complete Cat. III
170 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin 272.00 Pt 257.55
socket erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured / metallic / white front plate modules erected on / in wall
/ ceiling with following type accessories Cat. III
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
171 Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth 14.00 Pt 603.98
wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires erected in below type of pipe with 6A
Modular type switches and following type of accessories erected on PVC /
Metallic/Wooden box, single mounting base frame covered with textured /
metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling rose or H.D. Connector
as directed.(f) with medium class Rigid PVC pipe and accessories erected
concealed in wall / ceiling complete Cat. III
172 Providing following type of Modular Type Accessories mounted with PVC / 24.00 Ea 160.59
metallic / Wooden box, single mounting base frame covered with textured /
metallic/white front plate, modules erected with necessary connections as per
site situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone
Socket [A] For One Gang Cat. III
(4) TV Co-axial Socket outlet Cat. III 6.00 Ea 160.59
(5) Electronic hum Free steps EME Fan regulator Cat. III 2.00 Ea 398.95
(7) Blank Plate Single Cat. III 244.00 Ea 25.25
(8) Computer RJ-45 socket Cat. III 63.00 Ea 160.59
(9) 16 Amp. SP one way switch Cat. III 37.00 Ea 180.79
(10) 6/16Amp. Universal socket Cat. III 37.00 Ea 199.98
173 Providing & erecting following type of Modular Type Accessories with 63.00 Ea 36.36
necessary connection. As desired by Engineer In charge (5) LAN cable
connector with ferule
174 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following 2955.00 Mtr. 24.24
size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (a) 20 mm
(b) 25 mm 773.00 Mtr. 33.33
(c) 32 mm 110.00 Mtr. 54.54
175 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 4203.00 Mtr. 82.82
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (A) With medium class Rigid PVC pipe and
accessories (b) 2 wire 2.5 sq. mm
176 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 914.00 Mtr. 112.11
marked stranded Copper conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq.mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq.mm
(b) 2 wire 6 sq. mm 81.00 Mtr. 147.46
(c) 2 wire 10 sq. mm (use earth wire of 4 sq.mm ) 15.00 Mtr. 236.34
(h) 4 wire 6 sq. mm 259.00 Mtr. 260.58
(i) 4 wire 10 sq. mm(use earth wire of 4 sq.mm ) 195.00 Mtr. 425.21
177 Providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi 16.00 Mtr. 37.37
stranded, annealed copper conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears, motor starters &
control wiring) with required size of copper lugs, nuts and bolts if required.(d)
One wire 4.00 sq. mm
(e) One wire 6.00 sq. mm 40.00 Mtr. 56.56
(f) One wire 10.00 sq. mm 22.00 Mtr. 91.91
(h) One wire 25.00 sq. mm 14.00 Mtr. 236.34
(i) One wire 35.00 sq. mm 6.00 Mtr. 300.98
(k) One wire 70.00 sq. mm 4.00 Mtr. 669.63
(l) One wire 95.00 sq. mm 2.00 Mtr. 919.10
178 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv 975.00 Mtr. 22.22
grade ISI marked copper wires of following size to be erected as directed. (c)
1.00 Sq.mm 2 core round/ flat PVC sheathed
(e) 1.50 Sq.mm 3 core round PVC sheathed 281.00 Mtr. 46.46
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
179 Providing & erecting approved make following size of TV Co-axial flexible 105.00 Mtr. 62.62
cable comprising inner conductor of solid bare copper insulated with Foam PE
& Secondary conductor made of poly - Aluminium film bonded Al. Braids @
suitable coverage overall sheathed with black PVC insulation.(e) RG-11
180 Supplying & erecting approved make Telephone Cable electrolytic copper 570.00 Mtr. 20.20
conductor PE insulation twisted in two pairs & wrapped with FRLS PVC tape
& sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone
wiring & confirming to C-DOT erected in existing pipe of following size of
conductors & nos.of pairs with necessary connections. [A] Conductor Size
mm (a) Unarmoured (2) Two Pairs
(5) Ten Pairs 45.00 Mtr. 65.65
(6) Twenty Pairs 20.00 Mtr. 127.26
181 Supplying & erecting approved make LAN cable of following size in existing 2016.00 Mtr. 47.47
pipe as per direction [C] CAT -
182 Providing & erecting main Distribution (MDF) indoor type, back mounted 2.00 Ea 994.85
frame as per DoT standard approved with krone strips (a) Suitable for 10 pair
(b) Suitable for 20 pair 2.00 Ea 1368.55
183 Providing & erecting Switch board for Computer or electric apparatus 63.00 Ea 1133.22
consisting of following modular type accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame covered with textured /
metallic / white front plate, modules erected with necessary connections as
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
184 Bakelite adopter for Holder to be erected. 320.00 Ea 9.09
185 Decorative call bell Ting-tong box type 250 volts complete erected 9.00 Ea 71.71
186 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 320.00 Ea 373.70
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt, LED LED
driver efficiency > 85% (fitting required LM-79 & LM-80 Certificates) (NOTE:
Below description have shown ranges of Wattage capacity of LED fittings.
shown) (A) Tube Light with integral driver (iv) 22-24 Watts, Surge - 2KV, IP-
20, conventional 4 feet Cat-lll
187 Supplying and erecting led lamps with following wattage capacity of 220 to 44.00 Ea 188.87
240 voltage, minimum 15000 burning hours life, 500 V in built-surge
protection, Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable
LAMP holder (iii) 10 to 15 watts Cat-lll
188 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 92.00 Ea 758.51
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt, LED driver efficiency > 85% (fitting required LM-79
& LM-80 Certificates) (NOTE: Below description have shown ranges of
wattage capacity between the ranges shown) (A) Square/ Circular shaped
Surface / Recessed Mount Downlight with provision for spring loaded
mounting clips complete. IP20 (iv) 22-24 watts, Surge-2 KV Cat-lll
(B) LED Panel Light with provision for Plane front frame with translucent cover 5.00 Ea 724.17
fixed to housing complete. IP20 (v) 24 watts, 12" x 12", Surge-2 KV Cat-lll
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
189 Supplying and erecting LED street light / Flood light fittings with High power 19.00 Ea 3345.12
White LEDs wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10%, CCT 3000 K to 5700K,Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85%.
(fittings required LM-79 & LM-80 certificates) (NOTE: Below description have
shown ranges of Wattage capacity of LED fittings. The Engineer incharge
(IP-65), Surge protection -4KV integral and ,Light must have 440VAC line
supply with over-voltage protection. (i) above 36 to 48 watts Cat-lll
(ii) above 48 to 60 Watts Cat-lll 40.00 Ea 4997.48
(C) Post Top Lantern LED fitting comprises of finish cast aluminum spigot and 2.00 Ea 4819.72
spun aluminum canopy fixed with opal polycarbonate, pipe arrangement for
vertical mounting driver and accessories wired upto terminal block.IP 65 (ii)
32-40W Cat-lll
190 Providing and erecting Approved make Four pole moulded case circuit 9.00 Ea 6173.12
breaker having breaking capacity ICU of 25 KA. at 415 V,having normal
current rating up to 25 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S. housing.ICS=100% of
ICU only. Cat III
191 Providing and erecting Approved make Four pole moulded case circuit 3.00 Ea 8055.76
breaker having breaking capacity ICU of 35 KA. at 415 V. having normal
current rating 125A. with Fixed thermal & magnetic release suitable to work
on A.C.supply 50 c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only. Cat
192 Providing and erecting Approved make Four pole moulded case circuit 2.00 Ea 16221.61
breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal
current rating 200A.with variable Thermal & magnetic release suitable to work
on A.C.supply 50 c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing ICS=100% of ICU only. Cat III
193 Providing and erecting Approved make Four pole moulded case circuit 1.00 Ea 20946.39
breaker having breaking capacity ICU of 35 KA. and above at 415 V having
normal current rating 250A. with variable thermal & magnetic release suitable
to work on A.C. supply 50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU
only. Cat III
194 Providing and erecting Approved make Earth fault Relay suitable to mount 1.00 Ea 4687.41
with inter connection suitable to following size of moulded case circuit breaker
having CT ratio & MCCB rating as following along with shunt trip 220V AC.
with all internal connections & complete erected in existing M.S.housing. (1)
15 A -100 A, CT Ratio 1/100
(2) 125 A -200 A, CT Ratio 1/200 2.00 Ea 4983.34
(3) 250 A -400 A, CT Ratio 1/400 1.00 Ea 5415.62
195 Providing and erecting following additional parts for panel mounting MCCBs 15.00 Ea 873.65
(A) Extended operating rotary handle with pad lock with three position trip, off,
on suitable for 25A to 250 A panel mounting Cat-III
196 Supplying and erecting triple pole & neutral 440V / 500V panel mounting 1.50 Rn. 1961.42
Copper Busbars with four equal Nos. of electrolyte bus having current density Mtr.
not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence of following current
carrying capacity, erected with necessary bus bar supports /insulators, main
cable socket to each bar, erected in existing cubical panel with necessary
connections.(A) Suitable for 100 Amp. Capacity
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
(B) Suitable for 200 Amp. capacity 0.60 Rn. 3202.71
(C) Suitable for 300 Amp. capacity 0.60 Rn. 4909.61
197 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system 59.00 Ea. 270.68
and having breaking capacity 10 KA to be erected in existing box confirming
to IS 8828/1996 with ISI Mark Cat III
198 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable 182.00 Ea. 112.11
to operate on 240 V A.C. system and having breaking capacity 10 KA to be
erected in existing box confirming to IS 8828/1996 with ISI Mark Cat III
199 Providing & erecting 240 V MCB double pole switch for motor & inductive load 3.00 Ea. 330.27
(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing
box having following capacity (B) 40 Amp. Cat III
200 Providing & erecting 240 V MCB double pole switch for lighting Load (B 20.00 Ea. 278.76
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box
having following capacity (A) 6 to 32 Amp.Cat III
201 Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) 13.00 Ea. 578.73
having 10KA breaking capacity & confirms to IS :8828 in existing box having
following capacity (A) 6 to 32 Amp.Cat III
(B) 40 Amp. Cat III 9.00 Ea. 638.32
202 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C 10.00 Ea. 668.62
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
having following capacity (b)40 Amp.Cat III
(c) 63 Amp..Cat III 17.00 Ea. 737.30
203 Sheets steel powder coated enclosure suitable for incorporating One/Two 6.00 Ea. 176.75
204 Providing and erecting Sheet Steel powder coated MCB distribution board - 1.00 Ea. 1152.41
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs. (The DBs should be used of same company of
MCB to be used) suitable for (A) single phase incoming and horizontal single
phase outgoing (b) sheet steel double door (IP-43) (iii) 8 way
(iv) 12 way 3.00 Ea. 1492.78
(v) 16 way 1.00 Ea. 1680.64
(B) three phase incoming and single phase horizontal type outgoing Per 4.00 Ea. 2339.16
phase isolation type (PPI) (b) sheet steel double door (i)4 way
(ii) 6 way 7.00 Ea. 2913.85
(iii) 8 way 2.00 Ea. 3412.79
205 Providing and erecting Approved make RCCBs conforming to IS: 12640 and 10.00 Ea. 1969.50
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz. having characteristic of
quick action & tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as directed (i)
Amps.DP Cat III
(ii) 40 Amps. DP Cat III 34.00 Ea. 2235.13
206 Providing and erecting metallic vitrified danger notice board as per language 2.00 Ea. 69.69
suggested by engineer incharge for MEDIUM VOLTAGE installation to be
erected as per IS-2551.
207 Providing & erecting Medium Voltage Danger Notice Board sticker as per 6.00 Ea. 26.26
language suggested by engineer incharge of standard size as per IS-2551
208 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 6.00 Kg. 794.87
209 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. 31.00 Ea. 368.65
dia. galvanised iron pipe with coupling and buch buried in specially prepared
earth pit complete with necessary 8 SWG earth wire.
210 For using salt and charcoal / coke as required for pipe type earthing. 31.00 Ea. 171.70
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
211 Supplying & erecting earth pit of minimum bore dia.150mm size approved 9.00 Ea. 4591.46
make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I. pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge dissipation
suitable for following type of applications with chamber and heavy duty cover.
(A) (approved make OEM has to submit test certificate including value of
earth resistance of installation duly stamped and signed by agency and officer
Incharge has to ensure the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity :- 0.2 ohm / meter testing as per IEC 62561-2017,
Voltage drop :- < 1 volt at no load & dry form, Sulphar content:- <2% (C) Back
fill Compound :- Earthing compound should be capable to retain moisture for
long time Necessary test report must be submitted by Agency. (a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
212 Providing & erecting weather proof, dust & vermin proof, floor mounted front 5.10 Sq. 16323.62
operated outdoor type double door cubical panel board necessary IP-54 and Mtr.
above protection as per approval from engineer incharge made from 14 SWG
thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet
for internal partitions with necessary accesories, supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-
charge with erection of supplied switch gears, BUSBARS, suitable size of
inter connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring instruments, earth
bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of
hinged doors, handles with locking arrangement and rubber gasket, heavy
duty end terminal connection, danger notice board, necessary ventilation,
earthing strip complete.
The Panel shall be painted with epoxy powder coating. (The rates excludes
the cost of switchgears, bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The dimension shall be measured
excluding base beams) The panel shall be supplied with following approved
manufacturers with following size.(B) The standard companies switch gear
shall be used and only manufacturers at CPRI approved factory (i) with
350mm depth
213 Supplying & erecting XLPE(IS:7098) (I)-88 ISI unarmoured Aluminium cable 130.00 Mtr 53.53
1.1 KV. grade to be erected as directed of following size. (B) 2 core 4 Sq. mm
(C) 2 core 6 Sq. mm 85.00 Mtr 71.71
214 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable Aluminium 100.00 Mtr 92.92
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables. (B) 2 core 6 Sq.mm
215 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand 105.00 Mtr 220.18
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe of following size of cables (B) 3 1/2 core 35 Sq. mm
(16 Sq.mm 1/2 core)
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) 12.00 Mtr 378.75
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) 120.00 Mtr 540.35
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) 18.00 Mtr 731.24
216 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / 245.00 Mtr 126.25
Solid Aluminium conductor for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe of following size of cables (B) 4 core
(C) 4 core 10 Sq. mm 135.00 Mtr 140.39
217 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand 75.00 Mtr 190.89
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe of following size of cables (B) 4 core 25 Sq.mm
218 Making trench in soft soil of suitable width of 90 cm deep for laying cable or 434.00 Mtr 55.55
locating the fault all over the run and back filling the same and making the
surface as normal ground.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
219 Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below 10.00 Mtr 226.24
ground across the road crossing or on floor with necessary material in an
approved manner and making the ground as per original.(F) 100 mm dia.
220 Providing & laying approved make Double walled corrugated pipes (DWC) of 590.00 Mtr 62.62
polyethylene (conforming to IS 14930 II) with necessary connecting
accessories of same material at required depth in existing trench for laying of
cable below ground / road surface for enclosing cable (A) 50 mm outer dia
(C) 90 mm outer dia 139.00 Mtr 95.95
221 Providing and, fixing heavy duty flange type brass cable gland with rubber ring 22.00 Ea 33.33
for PVC insulated armoured cable complete with out going tails, insulating
tape etc for following size of cables. (A) 2 to 4 core 2.5 / 4 Sq.mm
(B) 2 to 4 core 6 Sq. mm 60.00 Ea 38.38
(C) 2 to 4 core 10 Sq. mm 18.00 Ea 38.38
222 Providing and, fixing heavy duty flange type brass double compression type 2.00 Ea 66.66
cable gland with rubber ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of cables.(A) 3 & 1/2 /
core 25 Sq. mm
(B) 3 & 1/2 core 35/50 Sq. mm 6.00 Ea 75.75
(C) 3 & 1/2 core 70 Sq. mm 2.00 Ea 103.02
(E) 3 & 1/2 core 120 Sq. mm 2.00 Ea 140.39
(F) 3 & 1/2 core 150 Sq. mm 2.00 Ea 190.89
223 Solder less crimping type Aluminium lugs conforming to IS suitable for cable 248.00 Ea 6.06
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. (A) 1.5/ 2.5/4/6 Sq.mm
224 Providing & erecting Approved make Ceiling Fan with double ball bearing with 4.00 Ea 1982.63
Condenser 230 volt A.C.50 Hz. 900 mm sweep complete having 3 Aluminium
blades, canopy erected complete. [Make shall be approved by Engineer in
225 Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with 179.00 Ea 1948.29
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3 blades with aluminium blades with canopy & 30 cm.
down rod erected with earthing.(Make shall be approved by Engineer in
226 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe 183.00 Mtr 108.07
down rod erected duly painted for fan complete with proper insulation without
leakage and earthing.
227 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the 222.00 Ea 108.07
RCC bars up to 50mm length each side and pierced through a 16 Gauge
M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with
necessary finishing.
228 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan 222.00 Ea 18.18
229 Supplying & erecting approved make low noise decorative exhaust fan having 13.00 Ea 1703.87
square frame ABS body with inbuilt lowers & square frame.200mm with
1350RPM Cat.II
230 Supplying & erecting single phase approved make industrial exhaust fan 5.00 Ea 2054.34
suitable for medium duty ring mounted low noise operation suitable for
medium duty having following dia size and maximum speed in RPM [A]
mm dia 900 RPM Cat.II
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
231 Supplying and erecting approved make Octagonal pole made from HR sheet 30.00 Ea 6874.06
steel. The pole should be made as per IS and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mm x 7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be erected with suitable
foundation (Included) as per details given by manufacturer considering site
requirement. (C) 5 Mtr. Long 70 mm top x 130 mm bottom dia, 3 mm
thickness with 200mm x 200mm x 12mm base plate, 4-M16 Bolts and 600mm
long with necessary G.I. J Bolts .Approx Pole weight 46 kg
232 Supplying & erecting approved make SMC press moulded composite FRP 2.00 Ea 898.90
loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip
5way (3P+N+E), DIN rail for mounting mob & hinged doors as per
requirement having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable clamps& earth bolt of
following size of box. (A) 300mm x 200mm x 100mm [deep]
(C) 150mm x 125mm x 100mm [deep] 20.00 Ea 476.72
233 Providing and erecting street light pole bracket comprising main B Class GI 20.00 Ea 614.08
pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require
size pole top having sufficient fasteners for fixing the brackets and having
spread of 1 mtr. length with suitable rise as per site condition & suitable
welded stiffener reducer and nipple with check nut complete painted with one
coat of Red oxide / PU base primer and two coats of Aluminium / PU paint.
paint with following nos of arms.[A] Single Arm bracket 1 Mtr
[B] Double Arm Bracket 1 Mtr 10.00 Ea 829.21
234 Supplying and erecting B class Galvanized iron pipe having smooth finished 19.00 Mtr 215.13
bore of the pipe on both ends erected nuts and bolts along the pole / wall
shaping the pipe as per site requirement. Pipe dia as following. (B) 32 mm
235 Supplying & erecting IP 55 grade following size section pillar fabricated from 1.00 Ea 16691.26
joint less M.S. Sheet with angle iron legs made from jointless M.S. Angle with
cable clamps to be buried in ground to have appropriate erection to work
uniform until erected with cement concrete foundation and 45 cm high bricks
work finishing with plaster etc. hinged double door internally supported on
both side, with internal and outside looking arrangement with look and keys in
duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is welded and other
with nut and bolt for erecting Bakelite sheet. Painting the Section Pillar inside
and out side with three tank powder coated paint. section pillar roof should be
without joint with water leakage proof & tested as per IP 55 test & followed by
IS 2147 of 1962 (A) 150 x 90 x 75 cm section pillar fabricated from 14 Gauge
MS Sheet with angle iron legs 95 cm long made from 40 x 40 x 6 mm thick
236 Supplying and erecting HYLAM sheet on existing angle iron frame.for 1.00 Sq. 771.64
following thickness (B) 4mm Mtr.
237 Supplying & erecting approved make Digital time switch having lithium cell 6 3.00 Ea 3168.37
years operative and operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD display. Also
comprised permanent ON/OFF switching. Programming switches & housed in
fire proof thermoplastic enclosure & transparent cover erected as required
with necessary connection erected as directed.
238 Supplying & erecting power contactor, AC3 duty for time switch complete 1.00 Ea 1883.65
erected as per direction Cat III (B) 2 pole 250V 32 Amp.
(D) 4 pole 440V 40 Amp. 2.00 Ea 2782.55
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
239 SITC of Digital / PCM / TDM EPABX System having SMT design, system with 1.00 Ea 51440.31
flexible universal slots. Inbuilt Auto attendant facility, Minimum 15 Nos.
conference, Analog extension line, Calling GSM, E&M line, PRI / EI & VOIP
program me through Analog telephone digital key from Ethernet, public
address cord, shall have unrestricted simultaneous dialing facility, QSIG
protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-
Single Digit dialing of any two external number, Once only ring device,
Chairman / Secretary - Do not disturb Facility, Power Down Mode, Hot Line,
Hot Outward Dialing, Day Night Mode, Auto Call Back, Barge-in, Call Pick Up
& Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA),
Caller ID (CLI), CLI Base ECF, CLI Base routing Internet Ready Port, External
Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID Direct
Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing
with following capacities [Approved by Competent Authority i.e. not Below the
rank of Executive Engineer]
[B] No of Extension 24, No of Junctions 9, 8 Port
IP Resource in-built, 4 Port Web base Video
Conferencing, No of expandable ports : 96, Operators
Console - 01 Compatible : ISDN
240 Providing and erecting Digital key phone (12-16 direct key) [Approved by 1.00 Ea 3955.16
Competent Authority i.e. not Below the rank of Executive Engineer]
241 Supplying & erecting push button type telephone instrument having speaker 10.00 Ea 898.90
phone Caller ID & speaker phone with one touch memory (min.6 nos.) &
memories with display system Single line [Approved by Competent Authority
i.e. not Below the rank of Executive Engineer]
242 Supplying microphones stands with sturdy mechanism, treble free movement 3.00 Ea 445.41
& positioning of microphones, free from rust with superior quality of chrome
plating with following size. [Approved by Competent Authority i.e. not below
the rank of Executive Engineer] (c) Fixed height 91 cms. & extendable up to
62 cms. with round base of dia. 23 cms.
243 Supplying & testing wireless microphone system for 92.5 MHz FM operation 4.00 Ea 1884.66
With effective range 200 feet with microphone having facility for frequency
adjustment & receiver with LED indicator Telescopic antenna with battery
cells. [Approved by Competent Authority i.e. not below the rank of Executive
244 SITC of Gooseneck microphone 2.00 Ea 12046.27
Unidirectional condenser microphone
Flexible stem
Phantom powered by amplifier
On/off sliding switch with priority contact
Supplied with fixed 2 m (78 in) cable and lockable DIN connector [Approved
by Competent Authority i.e. not Below the rank of Executive Engineer]
245 SITC of Dynamic microphone, 6.3mm jack Unidirectional dynamic 3.00 Ea 2887.59
microphone
Handheld or stand-mounted use with clip (supplied)
Rugged construction
Modern non-reflective dark Grey finish [Approved by Competent Authority i.e.
not Below the rank of Executive Engineer]
246 SITC of Music source, USB/SD/Tuner MP3 playback from SD card and USB 2.00 Ea 60294.98
FM tuner with RDS, presets and digital control
Simultaneous operation of SD/USB-player and FM tuner
Separate outputs for digital source and FM tuner [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer]
247 SITC of PLENA 360W ALL-IN-ONE AMPLIFIER [Approved by Competent 3.00 Ea 67230.65
Authority i.e. not Below the rank of Executive Engineer]
248 SITC of Cabinet loudspeaker, 15W, black High-fidelity music and speech 15.00 Ea 9380.88
ABS enclosure Supplied with adjustable mounting bracket Complies with
international installation and safety regulations [Approved by Competent
Authority i.e. not Below the rank of Executive Engineer]
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
249 SITC of Cabinet loudspeaker, 30W, black 15.00 Ea 13399.67
High-fidelity music and speech reproduction
Compact yet robust ABS enclosure
Supplied with adjustable mounting bracket
Complies with international installation and safety regulations [Approved by
Competent Authority i.e. not Below the rank of Executive Engineer]
250 SITC of Horn loudspeaker, 20W High efficiency drivers 8.00 Ea 9841.44
Wide opening angle
Excellent speech reproduction
Simple power setting
Water- and dust protected to IP
Versatile mounting bracket
Complies with international installation and safety regulations [Approved by
Competent Authority i.e. not Below the rank of Executive Engineer]
251 SITC of Horn loudspeaker, 30W High efficiency drivers 1.00 Ea 10306.04
Wide opening angle
Excellent speech reproduction
Simple power setting
Water- and dust protected to IP
Versatile mounting bracket
Complies with international installation and safety regulations [Approved by
Competent Authority i.e. not Below the rank of Executive Engineer]
252 SITC of 3LCD Lamp based projector having wxga (1280x800) or better 1.00 Ea 33895.60
resolution with minimum white brightness of 3800 lumens and color
brightness of 3800 lumens. The projector should have minimum 1HDMI,1VGA
input. Having contrast ratio of 15000:1 or more. the projector should have
auto vertical key stone correction of +/- 30 degree and Manual Horizontal of +/-
30 degree. the projector should have optical lens, throw ratio 1.30-1.56:1.
Zoom Factor of 1.2. Lens focus Manual having focal length 16.9mm to
20.28mm. projector should have features like AV mute slide, quick corner and
split function and should support wireless functionality with inbuilt wifi or wifi
dongle. [Approved by Competent Authority i.e. not below the rank of Executive
253 SITC of universal Projector mounting kit, with necessary grouting, fasteners 1.00 Ea 6848.81
etc. with adjustable height and suitable for all types of projectors. [Approved
by Competent Authority i.e. not below the rank of Executive Engineer ]
254 SITC of 120 inch Self Lock MW (8 x 6) Instalock Slow Retraction Screen, 1.00 Ea 5334.82
Aspect Ratio-4:3 [Approved by Competent Authority i.e. not below the rank of
Executive Engineer]
255 Providing and erecting approved make split air-conditioning unit consisting of 5.00 Ea 45209.62
copper condensing unit with fan motor, hermetically sealed rotary compressor
with accessories etc. duly connected separately erected evaporating unit and
blower motor with its accessories by means of extra supplied proper insulated
copper tubing, drain PVC pipes suitable for (cost includes powder coated
Stand, Eco Friendly green gas charging, 15A plug top & Remote Control) with
necessary core cutting. (2) For ISEER Range (KWH/KWH) (4.0 to 4.49) (b)
for 1.5 ton capacity
(c) for 2 ton capacity 6.00 Ea 59293.06
256 Supplying and erecting insulated pair of soft copper tubing open or concealed 66.00 Rmt 965.56
including power and control cable,necessary PVC drain pipes for Split AC
machine up to 4 TR capacity
257 Providing & erecting water cooler having storage capacity 150 Ltr. & cooling 2.00 Ea 55893.40
capacity 150 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour, The water cooler should be
comprising of hermetically sealed compressor, fan motor, condensing unit,
water tank surrounded by evaporating, coil, thermostats, relay etc.complete
with necessary inlet & outlet connection. The body of water cooler will be
made from Stainless Steel.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
258 Supplying & erecting 5 stage single reverse osmosis water purification system 2.00 Ea 29187.99
with M.S. powder coated frame, prefilter housing with 'O' ring presediment
filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi,
mention with 40 psi inline type post carbon filter auto low & high pressure
switches with following size of storage tank & LPH capacity & erected as
directed [C] 50 Ltr / Hr with 150 psi 2 nos booster pump
259 Providing & Erecting Deep Freezers effective and economical Solutions for 2.00 Ea 41770.57
safe storage of perishable foods.The range of hard - top deep freezers
Technical Specification
Gross Capacity 400 ltr., Temp. Range -18°C to -22°C, Power Supply
230Volts, Single phase, 50Hz,Refrigerant R134A, No of lids 2,Inner Cabinet
Pre-painted GP Steel, Puf Thickness 60*60,Over all No of Baskets
01,Wheels/Legs Heavy Duty Castors.
260 Supply and Erecting of Static Stabilizer suitable for following capacity of A.C 5.00 Ea 3030.00
Machine the Stabilizer Must have Minimum Technical Specification are Input
working Single Phase Voltage Range Up to 150V-280V.50Hz, Output Voltage
Range Up to 200V-240V,50Hz,Autoreset Facility, LED Display for Indicating
Voltage, Spike/Surge Protection,Time Delay Facility, Proper Wall Mount
Facility with required Accessries & on site 3 year Replacement / Repairing
(1) For 1.5Ton Thermal Overload Protection 12 Amp.
(2) For 2 Ton Thermal Overload Protection 15 Amp. 6.00 Ea 4029.90
261 Supplying and erecting approved make online Un-interruptible Power Supply 1.00 Ea 130103.15
system comprising flat cum-boost charger with IGBT base rectifier & Inverter
& sealed maintenance free SMF batteries. The charger having operating
capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with
0.8 load power factor with battery, over/under voltage output with over load &
short circuit protection equipment. The system housed in CRC sheet duly
powder coated paint with following power backup.with MS painted batteries
stand, 10% Overload capacity for momentary load.(D) 5 KVA with 1Hr Backup
262 Supplying, installing, testing & commissioning of SOLAR WATER heating 2.00 Ea 102530.15
system as per prevailing IS code comprising of Solar flat locket collector,
stainless steel hot water storage isolated tank with S.S. heat exchanger,
absorber made of copper sheet & copper tube of following capacity in liter /
day (LPD) with "B" size aluminium box collector with appropriate capacity
electrical backup arrangement (Excluding inlet & outlet pipe lines) (D)
Capacity of 500 LPD
263 Supplying and erecting approved make panel mounting type Digital Voltmeter 5.00 Ea 1275.63
having 3 digits LED display, 0 to 750 AC Volts range erected on existing
panel board with all connection, wiring etc. with manufacturers calibration
certificate.
264 Supplying and erecting approved make panel mounting type Digital Ammeter 5.00 Ea 1558.43
having 3 digits LED display, external CT operated, calibrated for 0 to
Amps suitable to operate on 500 Volt AC, erected on existing panel board
with all connection, wiring etc. with manufacturers calibration certificate.
Supply 500 V on existing panel board with necessary connections.
266 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 15.00 Ea 274.72
ratio 15 VA burden erected in existing CRCA box duly secured with insulating
materials connected to the meter
267 Supplying and erecting approved make suitable panel indicator LED type 18.00 Ea 43.43
lamp, lens cover, complete erected with necessary connections.
268 Providing & erecting open well horizontal mono block pump set with cast iron 2.00 Ea 18746.61
body, complete for three phase submersible motor having [D] For 5 HP
phase open well horizontal mono block pump set suitable for 1350 LPM to
310 LPM @ 10 to 42 Mtr head suitable for 50/65 mm dia delivery pipe Cat.II
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
269 Supplying & erecting approved make motor control cubical panel (Direct - on - 2.00 Ea 7722.46
line) made from 16 G. CRCA sheet duly epoxy powder painted inside and
outside with hinged doors and locking, arrangement consisting of suitable size
of ON- OFF isolator (AC - 3/23duty) main fuses, single phasing preventer,
indicating lamps for R- Y - B phases, overload relay, Automatic water level
wires duly socket crimped, main contactor & overload relay, start - stop push
buttons, to be erected on angle iron frame grouted on wall as directed. The
isolator, overload relay & contactors will be of L & T, Siemens or BCH make
only. (A) DOL up to 5.0 H.P.
(B) DOL for 7.5 H.P. 1.00 Ea 8710.24
270 S.I.T.C. submersible pump set suitable for bore of 150 mm. dia. or more 1.00 Ea 35590.38
having three phase motor capacity not more than 7.5 H.P. with following
capacity. Lifting and Lowering taken extra.(A) (12 stage) 280 to 240 LPM
discharge at 90 to 104 mtrs. head respectively suitable for 50mm dia. delivery
pipe. Cat.III
271 Lowering of submersible motor pump set at the depth of following ,complete 1.00 Per 2568.43
with required. Nos. and size of casing pipes erected by means of proper chain Job
pulley block & pipe wrenches after checking of threads of each pipe with
coupling to take the load of the pump set and pipe assembly filled up with
water (B) Above 60 mtrs. and Up to 120 mtrs.
(D) For Open well Horizontal submersible pump set for sump well (i) 1 HP to 5 2.00 Per 856.48
272 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible 45.00 Mtr. 146.45
Submersible copper cable approved make of following Size. (C) 3 Core x
(D) 3 Core x 6 Sq. mm. 140.00 Mtr. 172.71
273 Supplying of following size of STANDARD UPVC column pipe with coupler 110.00 Mtr. 297.95
and wire lock [D] 50 mm dia
274 Supply of following size of TOP & BOTTOM accessories i.e. Adaptor set (CI) 1.00 Per 1489.75
long, pump guard set, starter pipe Rubber ring for submersible pump & Set
UPVC column pipe as directed by Engineer - in - charge with necessary
plumbing as desired. [D] 50 mm dia.
275 Supply, Installation, Testing & Commissioning of following size of Grid Tied
Solar Power Plant with Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame with Twin Wall Profile, Front Cover : High
Transmission Low-Iron Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module Efficiency should be approx.
19.5%-22%, Normal operating temperature 45'C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep. temp. co-
efficient of the PV module shall equal or better than -0.45% / degree C. Solar
PV modules of minimum fill factor 75% to be used. Unit Production :- More
than 4.5 Unit /kw /day (Actual) (1 Year Avg) with 10 year Product warranty and
25 year Linear Power Warranty includes all mechanical and electrical
parameters of the Solar panel. Modules must be complied to the
DCR(Domestic content requirements). The Ration of AC to DC is 5:6 for the
Installation capacity which are given in AC KW.
Solar Inverter : MPPT Range: MPPT Range: 80-1000 V, Max efficiency:
97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p
Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C,
Integrated protection of Inverter are Anti-islanding Protection, Input Reverse
Polarity Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection, Output
Short Circuit Protection, Output Over Voltage Protection, PV array string fault
Protection. Protection Degree: IP65, User Interface LCD & APP, Datalogger &
Communication: GPRS / Wi-Fi.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
Module Mounting Structure: The mounting (Rectangular pipe / square pipe /
circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep
galvanized with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness should be
minimum 2.5 mm. A certificate of a structural engineer certifying the strength
and stability of the mounting structure to withstand the weight and wind speed
of 150 km/hour throughout the life span of 25 years of the system, shall be
submitted by the vendors. Hot Dipped Galvanized steel coils. suitable
arrangement for base plate for foundation, solar panel mounting, the structure
should be suitable for carry the load of solar panel,wiring, sprinkler system
etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the
nut bolt used for installtion of stucture should be (SS 304) quality.
The ground clearance of the bottom most edge of solar panel shall not be less -
than 300 mm to 1200 mm or as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM x 40MM
b. Rafter - The minimum section (thickness) should be 60MM x 40MM
c. Purlin - The minimum section (thickness) should be 40MM x 40MM Balane
of System with necessary Swichgears (Suitabel size and protection of ACDB
& DCDB), inter connecting wiring, earthing system as per the CEIG drawing
approval, lightining arrester system as per the CEIG drawing approval, all
liasoning work with various gov. dipartment like state nodal agency,DISCOM
& CEIG is included in agency scope
(Excluding All charges namely GEDA Application fees, Solar connectivity
Charges, Meter connectivity charges, Meter testing Charges and system
stability / strenthning charges)
(C ) Grid Tied Solar Power System: 11 - 25 kW (3 - phase) 25.00 Per 42455.35
Total Rs.
i.e. Rs. Six Crore Sixty lacs Sixty thousand Five hundred Nine and Eighty paisa only.
I/We am/are willing to carry out the work @ ______________ % above/below percent (Should be written
in figures and words) of the estimated rate mentioned above. Amount of my /our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
Net Rs. ___________________________ Total Rs. ________________________
In words ____________________ In words ____________________
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-
Charge for which no extra payment shall be made.
2. The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3. GST and Income tax TDS will be deducted at a source while making payments of bills.
4. In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C, Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a
change as per actual mix design the cost of difference of cement consumption have been deducted from the rate of
original item at the rate of input rate mentioned in all the tender.
5. The Contractor will have to submit the all required mix design at his own cost before execution as directed
and to be approved from the Engineer in charge.
Above all items of "Schedule-B" with Item Description, Unit, Rate & Amount have verified by me and found
Deputy Executive Engineer Sr. Divisional Account Officer Executive Engineer
Lunawada (R & B) Sub Division, Mahisagar (R & B) Division, Mahisagar (R & B) Division,
Lunawada Lunawada Lunawada
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
E Tender Notice - Children home for Girls Lunawada.pdf
SBD Book - Children home for Girls at Lunawada.pdf
BOQ - Children home for Girls at Lunawada.pdf
Specification Index.pdf
Technical Specifications.pdf
Drawings.pdf
GRs.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .