Chief Officer, Mansa Nagarpalika
Provide, Supply and Installation of Fire System at Mansa Nagar Palika-Owned Building at Mansa , for Mansa Nagarpalika, Mansa, Dist- Gandhinagar.
340223
August 2026
Open
Civil Works
Works
Gandhinagar
3 documents required · 3 mandatory
₹1,770
Chief Officer Mansa Nagarpalika
₹4.3 L
30 Aug 2026
30 Aug 2026
30 Aug 2026
19 Sept 2026
30 Aug 2026
NAME OF WORK : Provide, Supply and Installation of Fire System at Mansa Nagar Palika-Owned Building at Mansa , for
Mansa Nagarpalika, Mansa, Dist- Gandhinagar.
total rate Total
Sr no Description QTY. Unit
Supplying, installation testing & commissioning of approved quality (class-
c) conforming to as per IS 1239 such as tee, elbows, check nuts, flanger,
nipples etc., including cutting welding, trending fixing on walls, ceiling
(using 41- tech pipe/ M.S. Angle supports work includes two coats of metal
1 primer and two coats of red enamel paint etc.,
Note : The piping installation has to be put to hydraulic test to1.5 times
Working pressure before applying paint or pipe coating and wrapping etc.
100mm dia pipe 580 mtrs. 2525
80mm dia pipe 30 mtrs. 2121
Supplying, Installation, Testing and Commissioning of electric driven Fre
pump suitable for automatic operation and consisting of following:
complete in all respect as required at sardar patel Sanskritik bhavan
a) Horizontal type, single stage, centrifugal, end suction pump of cast iron
body & bronze impeller with stainless steel shaft, mechanical seal to ensure
a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at
specified flow of 30hp and 70m Head. head conforming to IS 1520.with
suitable size of footvalve confirming to IS 4038, Pressure rating PN2,
preventing entry of foreign body to pump through suction pipe, perfectly
flat seating surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed
2 1500 RPM, suitable for opertion on 415 volts, 3 phase 50 Hz. AC with IP 55 1 Nos. 127260
class protection for enclosure, horizontal foot mounted type with Class - 'F'
insulation, conforming to IS-325.
c) M.S. fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
e )The pump should be ensure a minimum pressure of 3.5 kg/sq. cm at
highest and farthest outlet
Supplying, Installation, Testing and Commissioning of electric driven Fre
pump suitable for automatic operation and consisting of following:
complete in all respect as required at Palika Building, Raniyapura and
Takhatpura Co. Hall
a) Horizontal type, single stage, centrifugal, end suction pump of cast iron
body & bronze impeller with stainless steel shaft, mechanical seal to ensure
a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at
specified flow of 10hp and 60m Head. head conforming to IS 1520.with
suitable size of footvalve confirming to IS 4038, Pressure rating PN2,
preventing entry of foreign body to pump through suction pipe, perfectly
flat seating surfaces for good sealing.
3 b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 3 Nos. 107060
1500 RPM, suitable for opertion on 415 volts, 3 phase 50 Hz. AC with IP
class protection for enclosure, horizontal foot mounted type with Class - 'F'
insulation, conforming to IS-325.
c) M.S. fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
e )The pump should be ensure a minimum pressure of 3.5 kg/sq. cm at
highest and farthest outlet
Supplying, Installation, Testing and Commissioning of electric driven Fre
pump suitable for automatic operation and consisting of following:
complete in all respect as required at sardar patel Sanskritik bhavan
a) Horizontal type, single stage, centrifugal, end suction pump of cast iron
body & bronze impeller with stainless steel shaft, mechanical seal to ensure
a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at
specified flow of 900 lpm and 60m Head. head conforming to IS 1520.with
suitable size of footvalve confirming to IS 4038, Pressure rating PN2,
preventing entry of foreign body to pump through suction pipe, perfectly
flat seating surfaces for good sealing.
b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed
4 1500 RPM, suitable for opertion on 415 volts, 3 phase 50 Hz. AC with IP 55 1 Nos. 91910
class protection for enclosure, horizontal foot mounted type with Class - 'F'
insulation, conforming to IS-325.
c) M.S. fabricated Common base plate, coupling, coupling guard,
foundation bolts etc. as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
e )The pump should be ensure a minimum pressure of 3.5 kg/sq. cm at
highest and farthest outlet
Supplying, installing and commissioning C.I.flanged pressure relief valve
5 with CI body,suitable flanges, nuts, bolts, gaskets etc. complete. a)100 mm 40 Nos. 1010
Supply, Provide and installing of Hydrant point at various properties of
mansa nagar palika as per directed by engineer in charge.
Fire Hydrant Landing Valve (Internal / External) (Stainless Steel (SS-304) , ISI
Supply, Installation and Testing of: Fire Hydrant Landing Valve with
necessary pipe fitments, hardware and consumables.
7 MOC:-Body: Stainless Steel (SS-304), Working Parts: Stainless Steel (SS- 18 Nos. 7120.5
304), Coupling: Stainless Steel (SS-304) , Standard: -ISI Marked.
Size:-63 mm (Flange End: NB 75 mm, PCD 160 mm)
Supply, Installation, Testing and Commissioning of Weather proof Standard
Fire Hose Cabinet wall mounting type (750 mm x 600 mm x 250 mm deep)
having Double door opening with necessary locking arrangement by allan
8 key suitable for housing 2 no.x15 mtrs. hose pipe, 1no. Branch pipe& nozzle 18 Nos. 7373
spanner. Duly synthetic enamel painted.
Fire Hose Pipe (Delivery Hose)- 63 mm x 15 m
Supply, Installation and Testing of: Fire Hose with Hose Couplings. Stainless
steel male and female coupling bound and rivetted to hose pipes with
copper rivets and copper wire complete as required.
9 RRL (ISI Mark- Type A) Fire Hose. 36 Nos. 7070
Hose Couplings: ISI Marked Stainless Steel.
With SS Wire Binding.
Standard: - ISI Marked & TAC Approved Hose.
Size:-63 mm dia x 15m long Hose.
Providing, fixing, testing and commissioning of Wall mounting swing type
first aid Fire Hose Reel with drum, hanging bracket, 30 M x 25 mm dia high
10 pressure hose reel tubing as per IS:884 with shut nozzle and ball valve and 18 Nos. 11312
all required accessories.
Fire Hose Short Branch Pipe
Supply, Installation and Testing of: Short Branch-pipe
MOC: Stainless Steel (SS-304).
11 Standard: ISI Marked, Heavy Quality. IS : 903, suitable for 10 Kg / sq.cm 18 Nos. 2222
operating pressure and suitable for interconnections to hose pipe coupling
Size:- 63 mm X 20 mm
Fire Hose Nozzle- Short Branch Pipe Nozzle.
Supply, Installation and Testing of: Short Branch-pipe Nozzle.
12 MOC: Stainless Steel (SS-304). 18 Nos. 1363.5
Standard: ISI Marked, Heavy Quality. IS : 903, suitable for 10 Kg / sq.cm
Supplying, fixing, testing and commissioning of butterfly valve of PN
rating with bronze / gunmetal seat duly ISI marked complete with nuts,
13 bolts, washers, gaskets conforming to IS 13095 of following sizes as
100mm dia 8 Nos. 6767
Providing, installation, testing and commissioning of non return valve of
14 following sizes confirming to IS:5312 complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
Providing, fixing, testing and commissioning of 25 mm dia Air Release Valve
15 and Ball Valve assembly on top of each riser for Air release system. 22 Nos. 1313
Supplying, Fixing, and testing and Commissioning of 2-way inlet directed by
16 engineer in charge. 4 Nos. 6161
Providing and fixing, testing and commissioning of conventional Fire Alarm
17 Panel 4 Zone 4 Nos. 10605
Ravel/Agni/System Sensor, or equivalent
18 Fire alarm Manual call poin” ( Size 100 x 100 mm or nearest) 20 Nos. 1262.5
Supply, Installation, Testing and Commissioning of Conventional Sounder
cum strobe having tone settings with range of 95dbA and field selectable
15/30/75/110 candelas.(with all mounting accessories , complete with
Junction Box for mooting on surface, cable lugs at ends, cable compression
glands, cable tags and Ferruling.)
Supplying & erecting approved make 3 phase motor control cubical panel (
Star - Delta) made from16 G. CRCA sheet duly painted with epoxy powder
painted inside and outside with hinged doors and locking arrangement,
consisting of suitable size of ON- OFF isolator (AC - 3/23 duty) main fuses,
single phasing preventer cum water level. Guard (Complete unit), Toggle
switch to by pass Single phase preventer cum WLG, indicating lamps for R-
Y- B phases, over load relay, Automatic water level controller, Ammeter &
Voltmeter each with two way selector switch incoming wires duly socket
20 Crimped, Panel to be erected on angle iron frame grouted on wall as 1 Nos. 71710
directed. Star Delta & main contactor, overload relay, thermal / Electronic
Star delta cutoff timer, start - stop push buttons. The isolator overload
relay & contactors of L& T, Siemens or Cuttler Hamer make only. Panel to
be erected on angle iron frame ground on wall.
(F) S / D up to 30 H.P. (Sanskrutik Bhavan)
Supplying & erecting approved make 3 phase motor control cubical panel (
Star - Delta) made from16 G. CRCA sheet duly painted with epoxy powder
painted inside and outside with hinged doors and locking arrangement,
consisting of suitable size of ON- OFF isolator (AC - 3/23 duty) main fuses,
single phasing preventer cum water level. Guard (Complete unit), Toggle
switch to by pass Single phase preventer cum WLG, indicating lamps for R-
Y- B phases, over load relay, Automatic water level controller, Ammeter &
Voltmeter each with two way selector switch incoming wires duly socket
Crimped, Panel to be erected on angle iron frame grouted on wall as
21 directed. Star Delta & main contactor, overload relay, thermal / Electronic 3 Nos. 49490
Star delta cutoff timer, start - stop push buttons. The isolator overload
relay & contactors of L& T, Siemens or Cuttler Hamer make only. Panel to
be erected on angle iron frame ground on wall.
(A) S / D up to 10 H.P. (Palika Building, Takhatpura and Raniyapura Co. Hall)
Providing, fixing, testing and commissioning of Pump ON/OFF Switch
Providing, installation, testing and commissioning of stainless steel Y-
strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet
23 with 3 mm dia holes with stainless steel flange. A) 100 mm dia 1 Nos. 8989
Providing, fixing, testing and commissioning of 100 mm dia foot Valve
24 assembly on top of each riser for Air release system. 4 Nos. 7575
Supplying and erecting Flexible PVC insulated multistrand multicore 1.1 kv
25 grade ISI marked copper wires of following size to be erected as directed.1) 2000 mtrs. 161.6
Supplying and erecting Flexible PVC insulated multistrand multicore 1.1 kv
26 grade ISI marked copper wires of following size to be erected as directed.1) 600 mtrs. 414.1
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of
following capacity with necessary clamps made from 50 x 6 mm M.S. Flat
with nut & bolts grouted in wall complete.
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of
following capacity with necessary clamps made from 50 x 6 mm M.S. Flat
with nut & bolts grouted in wall complete.
Providing, Fixing & Commissioning Fire exit signs of standard size
photoluminous type. (Auto glowing in dark type)
Providing, fixing, testing and commissioning of Pressure Switch with Needle
Supply, installation , testing comissioning of pressure gauge of 0-21
31 kg/sq.cm range with 15 mm dia stop cock valve,piping etc as required 4 Nos. 2424
Supply, installation , testing comissioning Elblow, Ankarfastner,
Gasket,bulet etc, directed by engineer in charge
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01_TENDER DOCUMENT_FIRE SYSTEM.pdf
02 GENERAL TECHNICAL FOR BUILDING WORKS.pdf
03 Specification of Material.pdf
04 Ele Spesification.pdf
05_SCHEDULE-B.pdf
06_Fire Safety Booklet 1.pdf
07_Fire Safety Booklet 2.pdf
08_Fire Safety Booklet 3.pdf
09_Fire Safety Booklet 4.pdf
01_NEW_TENDER DOCUMENT_FIRE SYSTEM.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .