Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical GROUND FLOOR KHUSHBU KUMARL W O DEEPAK TRIPATHI INDRAPURI ROAD ROAD NO 10 HEHAL SUKLIDEONAGAR RANCHI 834005 JHARKHAND | RANCHI | JHARKHAND | 834005 | Rejected-Technical Tender Cancelled |
| 2 | Rejected-Technical PATHERDIH SUDAMDIH DHANBAD | DHANBAD | DHANBAD | JHARKHAND | Rejected-Technical Tender Cancelled |
| 3 | Rejected-Technical | Rejected-Technical Tender Cancelled |
Tender Value
₹41.7 L
EMD Value
₹83,500
Closing Date
29 Dec 2025, 5:00 pmClosed
District Engineer, Zila Parishad, Dhanbad
District Engineer, Zila Parishad, Dhanbad
Repairing and painting work of Anchal building with main gate and compound boundary, at Jharia Anchal, District-Dhanbad
2025_ZPDH_108134_2
24/2025-26/DE/ZPDH/DHANBAD
Open Tender
Civil Works
Percentage
180 days
Jharia
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
₹83,500
14 May 2026
24 Dec 2025
31 Dec 2025
24 Dec 2025
29 Dec 2025
24 Dec 2025
Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/I
Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of El.
Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
Taking down chaukhats in doors Including all complete job
Providing P.C.C (1:3:6) in foundation -do - all complete as per building specification and direction of E/I
Providing 12 mm thick cement plaster (1:6) -do- all complete as per building specification and direction of E/I.
Providing 25mm thick water proof cement plaster all complete job.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface inluding preparing the plastered surface by rubbing wmooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per buHding specifica tionand direction of El.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Providing two coat of snowcem of approved shade and make over a c oat of cement primer on new surface including preparing the plas- tered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
Providing and laying Doublecharge vitrified floor lites in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, In all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement: 4 coarse sand). Jointing with grey cement slurry@ 3.3 kg/ sqm Including grouting the Joints with white cement and matching c l ements etc., complete. Size of Tile 600x600 mm.
Supplying.fitting and fixing 20 guage G.C.I. sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication, pro- viding necessary locking arrangement with haskal and domny duly f ixed in P.C.C. ( 1 :2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.
S/F/F good quality ,well dressed and well seasoned sal wood in choukhat in doors, windows skylights all complete as per building specification and direction of E/I.
Supplying, fltting and fixing 35mm thlek solid core type decorative double leaf flush door shutter all complete job.
Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinfoorced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Enginner-in-Charge.
Providing primer one coat of red lead paint of approved make over new steel surface -do- all complete as per building specification and direction of E/I.
Providing two coat of synthetic enamel paint of approved shade and make over steel surface -do- all complete as per building specification and direction of E/I.
Electrification Wiring of Light & Fan Point including 1.5 sqmm Cu , PVC insulated copper conductor with modular type switch, modular plat, suitable size GI box etc. as required
Supply and fixing of 15/16 A one way modular switch in existing board
Supply and fixing of 15/16 A 6 Pin socket in existing board
Power Plug wiring in PVC conduit 2x 4 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 Nos. 4sqmm FR insulated copper conductor single core cable for loop earthing as required
Supply and fixing of 5/6 A one way modular switch in existing board
Supply and fixing of 5/6 A 3Pin socket in existing board
S/F Modular boxes, base & cover plate size 1 or 2 Module
S/F Modular boxes, base & cover plate size 8/9 Module
Supplyand Fixing of 2pin 5 A ceiling Rose
Supply and fixing of Batten holder/angle holder including connection etcas required
Supply and fixing of 4 Way Double door three pole and neutral MCB DB, 240 volts, on surfaces / recess. (63 amp)
Supply and fixing following rating double pole .240 volts,isolator in the existing MCB db complete with connection ,testing and commissioning etc as required
Supply and fixing of 63 A TPN MCB
Supply and fixing of 6A/32 A SP MCB
Wiring for ckt / submain wiring along with earth wire (2x2.5sqmm + 1x2.5sqmm cu flexible cable) singe core cable in surface / recessed PVC conduit as required
Supply and drawing of 2 x 1.5 sqmm size of FR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required
Supply and drawing of 4 x 6 sqmm size of FR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required
Earthing with GI earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclouser with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required (63 amps )
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode, including soldering etc. as required
20/22 W LED Tube light
Supply of 1200 mm Ceiling Fan
Carriage of Materials Cement lead 5 km
Sand lead 35 km
Stone chips lead 20 km
Stone Metal lead 20 km
Bricks lead 8 km
Steel lead 5 km
Boundary Wall Earth work in excavation in foundation trenches - do - all complete as per building specification and direction of E/I.
Extra for earthwork in hard soil as per specification and direction of E/I (Vide classification of soil item -B)
Filling in foundation trenches and plenth - do - all complete as per building specification and direction of E/l (Mode of measurement compacted volume)
Providing coarse clean sand in filling in foundation trenches -do - all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing P.C.C (1:3:6) in foundation -do - all complete as per building specification and direction of E/I
Providing R.C.C (1:1.5:3) in foundation -do - all complete as per building specification and direction of E/I
Centering and shuttering including strutting , propping etc. and removal of form for foundation , footing , bases of columns, etc for mass concrete
Providing R.C.C (1:1.5:3) in band at plinth -do - all complete as per building specification and direction of E/I
Providind designation 75 B brick work in C.M. (1:6) in superstructure - do-as per specification and direction of E/I.
Centering and shuttering including strutting , propping etc. and removal of form for Lintels, beams , plinth beams, girders, bressumers and cantilever.
Supplying, fitting and fixing M.S grill gate with M.S. grills made of 20 x 6 mm M.S. flats or 16 mm. M.S. square bars fitted on 25 x 25x 6 mmM.S. angle frame -do- (when steel is not supplied by deptt. )
Providing R.C.C (1:1.5:3) in column -do- all complete as per building specification and direction of E/I.
Reinforced cement concrete work in beam, suspended floors,roofs having slope up to150 landings,balconies,shelves, chajjas,lintels, bands, plain window sills,staircases and spiral stair cases above plinth level up
Centering and shuttering including strutting , propping etc. and removal of form for columns, pillars, piers, Abutments, posts and struts.
Providing 12 mm thick cement plaster (1:6) -do- all complete as per building specification and direction of E/I.
Providing and fixing 18 mm thick gang saw cut ,mirror polished - -do- all complete as per building specification and direction of E/I. Granite stone slab colour black ,cherry / Ruby red
Providing two coat of snowcem of approved shade and make over a c oat of cement primer on new surface including preparing the plas- tered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/1.
Providing TMT steel reinforcement - do - all complete as per building specification and direction of E/I.
Carriage of Materials Cement lead 5 km
Sand lead 35 km
Stone chips lead 20 km
Stone Metal lead 20 km
Bricks lead 8 km
Steel lead 5 km
First Floor SHED Providing and laying in position cement concrete of specified grade excluding the cost centering and shuttering - All work upl to plinth level: (1:1.5:3) in foundation -do - all complete as per building specification and direction of E/I
Steel work welded in built up sections/framed workm including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed workm including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed workm including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed workm including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed workm including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/framed workm including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers
Providing two coats of painting with ready mix paint of approved shed and makeover steel surface including cleaning the surface throughly scafollinding and taxes all after removing dirt including scales smokes,
Centering and shuttering including strutting , propping etc. and removal of form for columns, pillars, piers, Abutments, posts and struts.
Providing TMT steel reinforcement - do - all complete as per building specification and direction of E/I.
Wiring of Light & Fan Point including 1.5 sqmm Cu , PVC insulated copper conductor with modular type switch, modular plat, suitable size GI box etc. as required
Supply and fixing of 15/16 A one way modular switch in existing board
Supply and fixing of 15/16 A 6 Pin socket in existing board
Power Plug wiring in PVC conduit 2x 4 sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 Nos. 4sqmm FR insulated copper conductor single core cable for loop earthing as required
Supply and fixing of 5/6 A one way modular switch in existing board
Supply and fixing of 5/6 A 3Pin socket in existing board
S/F Modular boxes, base & cover plate size 1 or 2 Module
S/F Modular boxes, base & cover plate size 8/9 Module
Supplyand Fixing of 2pin 5 A ceiling Rose
Supply and fixing of Batten holder/angle holder including connection etcas required
Supply and fixing of 4 Way Double door three pole and neutral MCB DB, 240 volts, on surfaces / recess. (63 amp)
Supply and fixing following rating double pole .240 volts,isolator in the existing MCB db complete with connection ,testing and commissioning etc as required
Supply and fixing of 63 A TPN MCB
Supply and fixing of 6A/32 A SP MCB
Wiring for ckt / submain wiring along with earth wire (2x2.5sqmm + 1x2.5sqmm cu flexible cable) singe core cable in surface / recessed PVC conduit as required
Supply and drawing of 2 x 1.5 sqmm size of FR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required
Supply and drawing of 4 x 6 sqmm size of FR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required
Earthing with GI earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclouser with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required (63 amps )
Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode, including soldering etc. as required
20/22 W LED Tube light
Supply of 1200 mm Ceiling Fan
Carriage of materials:- Cement lead 5 km
Sand lead 35 km
Stone chips lead 20 km
Steel lead 5 km
Goods & Service Tax (G.S.T.) -
Labour Cess -
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
SBD2.pdf
Tender Documents • 0.55 MB
BOQ_146064.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .