Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.8 LAccepted-AOC CHENNAI | CHENNAI | TAMIL NADU | 600001 | 1 | Accepted-AOC Work Order Issued | |
| 2 | Rejected-Technical | - | Rejected-Technical Higher than Estimate Rate | |
| 3 | Rejected-Technical | - | Rejected-Technical Higher than Estimate Rate |
Tender Value
₹19.5 L
EMD Value
₹19,500
Closing Date
20 May 2025, 3:00 pmClosed
EXECUTIVE OFFICER, UPPILIAPURAM TOWN PANCHAYAT
246/3, JEEVAN NAGAR, UPPILIAPURAM, THURAIYUR TALUK, TRICHY DISTRICT
CONSTRUCTION OF TOILET ( 6 SEATS ) AT GOVERNMENT HIGHER SECONDARY SCHOOL IN UPPILAPURAM TOWN PANCHAYAT
2025_DTP_555005_1
303/2025/A1
Open Tender
Civil Works - Buildings
Works
180 days
UPPILIAPURAM TOWN PANCHAYAT
CLASS II
1 document required · 1 mandatory
₹0
₹19,500
TOWN PANCHAYAT OFFICE, UPPILIAPURAM
16 Jun 2025
10 May 2025
20 May 2025
10 May 2025
20 May 2025
10 May 2025
10 May 2025 - 20 May 2025
14 May 2025
Amount
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering, and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed depositing the surplus excavated soil with in the compound in places shown by the departmental officers with intial lead and lifts and cleaning and levelling the site etc.,complete as per TNSS 23 & 24, V, VI (S2), VII, 9,10
Column
Grade Beam
Supply delivery and filling of Stone dust in Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per Standard Specification TNSS No. 24 & 25.
Plain Cement Concrete of mix 1 : 4 : 8 (One part of Cement four part of sand eight part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII
Supplying and errecting centering for Sides and Soffits including necessary supports and strutting upto3.29mt height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90mm x60mm and 10BG stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia supported at not more than 75cm centre to centre etc complete Complying with standard Specification without Strutting.( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII
Below Ground Level
Ground Floor
Ground Floor Column
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) -Footing, Plinth beam, Tie beam/Lintel, Ground Floor Roof beam, salbs, Sloped roof beam and slabs 30 V, VI (S5) VII & 13
BELOW G.L.
Ground Floor
Supplying and fabrication & placing in position Steel Reinforcement using TMT rods for all RCC works as per the design given including cost of steel and binding wire etc., Complete Complying with Std Specification TNSS No. 86 & 86 AV, VI (S3) ( S6 ) VII
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 23/4" standard specification including finishing, curing,etc., complete complying with standard specification 31 & Similar to 31C V, VI (S5) VII
Below G.L.
Ground Floor
Plastering in Cement Mortor 1:5 Mix (one part of Cement,, five part of sand)12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.TNDSS NO: 56, 57
Special Plastering in Cement Mortor 1:3 Mix (one Cement,, Three sand)10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.TNDSS NO: 56, 57
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mmboth profiles are reinforced with GI/1mm 125GSM and100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (blackcolour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided inthe louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round theframes. The ventilator should be got approved from theExecutive Engineer before use on work (PWD SOR Page No.71 Sl No.M -0675)
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete PWD SOR Page No :62 Sl. No : M -0652
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.. 39 A
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 39A
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 51 (10-1) V, VI (S5) VII, 3
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete as per standard specification and as directed by the deparmental officers 44 H V, VI, (S5A) VII ,3
Painting the new plastered walls with two coats of Exterior emulsion paint (weather proof ) first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt etc. complete and including necessary plaster paris putty etc. wherever required.as per (ISI STD) (It mustprovide excellent resistance against the growth of algae and fungi on the walls. And it must offer excellent protection against alkali and UV degradation and the durability period should be 5 years. 61 V, VI (S4) 3
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification..107 V, VI (S1) VII
Supplying and fixing in position Urinal partition with White Marble slab (Adanga) 18 mm to 20 mm thick of 4'0'' x 2'0''size and above of best quality including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The Marble slab should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). etc, complete as per standard specifications.SD 25
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for 5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point.etc, complete as per standard specifications SD 38
Supplying and Fixing of single box type 4 x 20 W LED Light fitting complete with Electronic Choke and Teakwood Round blocks on wall or ceiling with fluorescent tube with PVC unsheathed copper leads from terminals to the fitting. [ PWD SOR Page No ; 168 Sl. No : M 1273]
Supplying and fixing of 16 Amps DP switch of 500 V with metal clad with fuse and neutral (side Handle) on suitable T.W. board with earth connection only ( SD No :141)
Supply and run of 2 of 6 Sq.mm polythene insulated Sc Aluminium cable of 1100 V in grade for service bearer wire etc.,( S.D No:69)
Supply and Fixing of TNEB meter Board suitable for 32A Single Phase Service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1" x 1/8" Copper Flat) on TW Plank of Size 375mm x 300mm x 19mm with Supporting TW Reepers of 1" thick an either side with Painting with Suitable bolt and nuts for fixing the TW Plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB Meter to Fuse Unit (SD No :125)
Supply and delivery of following PVC Pipes and Other materials of good quality including cost of materials and labour with cost for coveyence to site etc Complete complying with standard Specifications. etc.,
32mm PVC Coupling (Heavy Duty)
32mm PVC Pipe
32mm PVC Bend
32 mm PVC Elbow
20mm PVC Pipe
20mm PVC Bend
20mm PVC Elbow
20mm PVC Union
15mm Screw down PVC tap
20mm Coupler
110mm 4 KSC PVC Pipe
110mm Dia Bend
110mm Dia Tee
1000 Lt Tank
Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers
Geophysical Investigation Charges
Drilling of 150mm dia Borewell in Hard rock area including 180mm dia pilot bore and labour charges for insertaion of casing pipe in the drilled hole etc.,
Supply of 150mm OD PVC Casing Pipe including transportaion charges etc.,
Supply and Delivery of Single Phase Pumpset with motor as per isi 20lpm x 150 m head
Conrol Panel Board Consist of following voltmeter &ammeter suitable for above pumpset
32 mm UPVC Colume Pipe
2.5 sq.mm Sub Flat Cable
RAJU BOYAN SANKAR (BID ID -1344479)
R SURESH (BID ID -1345698)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .