Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC | ₹34.2 L Quoted ₹36.1 L | L1 | Accepted-AOC Agreement was executed with Lowest quoted bidder MOHAMMED KAYANIKKARA (BEEPK1115B) with Agreement No. EE/BR-PKD/02/2026-2027 Dated 03.06.2026 |
| 2 | L2₹36.8 LRejected-AOC KAVANNUR GRAMA PANCHAYATH KERALA | ₹36.8 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | MOHAMMED KAYANIKKARA L1 | Contractor Balakrishnan V P L2 |
|---|---|---|---|---|---|
| 1.00KODUMBU CAUSEWAY REHABILITATION | |||||
| 1.00 | OD122538/2024-2025:Removing damaged concrete:
Loose and delaminated concrete shall be identified and marked before proceeding with the
removal. The loose cover concrete including the loose damaged concrete shall be removed upto
beyond the corroded bars to a minimum depth of 10 mm behind the reinforcement. Only
affected concrete shall be removed and conducting proper investigation, (Good & sound
concrete should not be chipped / damaged) by chipping / hacking with chisel and hammer or by
mechanical means like light weight chisel hammer, pneumatic chippers, making saw cut at
periphery to avoid feather edge for all height and removal and disposal of debris at designated
location including all material, labour, tools, temporary supports for structures, electricity, plant
and machineries etc. complete as directed by Engineer-in-charge and/or Consultant. Depth of
chipping may vary from 20 to 100 mm. | 180.93 | per sqm | 621.58 ₹1.1 L | 1,000 ₹1.8 L |
| 1.00 | OD122537/2024-2025:Rust remover/Rust Convertor:Cleaning of rust / scales / corrosion from reinforcement bars should be carried out using acid based rust remover, Reebakleens RR of Fosroc or equivalent, or using alkali based rust
converters such as Feovert of Krishna Conchem. The material is to be applied to the rusted
metal bar, using brush and leaving it to dry for 30 Min. & washing surface with fresh water as
required to exposed reinforcement bar at all heights, including all material, labour, tools,
temporary supports for structures, electricity, plant and machineries complete as per detail
specification and as directed by Engineer-in-charge and/or Consultant. The concrete surface
area containing the cleaned rebars shall be measured for payment. | 37.61 | sqm | 444.86 ₹16,731.18 | 444.86 ₹16,731.18 |
| 1.00 | OD122536/2024-2025:Anti Corrosive treatment to Steel:Providing & applying inhibition coats/system to exposed reinforcement bars & also new bars,after cleaning & removing scales and rust completely as specified in 1.4, Two component
inhibitor Nitozinc Primer std. of Fosroc or MasterEmaco P130 of BASF or equivalent having
specific gravity of 1.75 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40
microns DFT per coat as approved by Engineer-in-charge and/or Consultant shall be used as
per manufacturer?s specification in two coats at all heights, including all material, labour, tools,
temporary supports for structures, electricity, plant and machineries, necessary surface
preparation and necessary protection after and during work. The concrete surface area
contianing the rebars where the treatment is carried out shall be considered for measurement | 66.22 | sqm | 966.93 ₹64,029.14 | 966.93 ₹64,029.14 |
| 1.00 | OD122535/2024-2025:New/Additional steel Reinforcement: Supplying, cutting, fabricating new reinforcement Fe500 for Jacketing, and providing additionalsteel reinforcement to compensate corroded reinforcement in existing member etc. and fixing
with old existing reinforcement which was reduced to 15 % or more of its original diameter as
required as provided in original structure and additional steels as directed by EIC and/ or
consultant as required tying with 16 gauge annealed binding wire complete as per drawing and
specifications for all heights including all material, labour, tools, temporary supports for
structures, electricity, plant and machineries, curing etc. complete as directed by Engineer-incharge and/or consultant (TMT BARS of various size as required) | 489.96 | kg | 89.37 ₹43,788.17 | 89.37 ₹43,788.17 |
| 1.00 | OD122534/2024-2025:Anchoring mainsteel and stirrups: Drilling holes of min 4mm larger than new rebar diameter into existing concrete substrate for anchoring of new rebar and depth of Min. 10 times the diameter of rebar and fixing with anchor resin grout Lokfix E (35/55/75) series or Lokfix P or Emfix or chemical anchor material or Masterflow 935 of BASF or equivalent as per NF P 18-831 and NF P 18-836 includingcleaning, cutting, fabricating, chemicals, material, labour, tools, temporary supports forstructures, electricity, plant and machineries etc. complete as directed by Engineer-in-chargeand/or consultant for all heights | 90 | no | 417.78 ₹37,600.20 | 417.78 ₹37,600.20 |
| 1.01 | OD122533/2024-2025:Anchoring Steel & Shear Connectors:
Drilling holes into existing concrete structure for anchoring of new rebar with 10 mm dia. shear
connectors at 0.5 Mt. c/c (or as per design recommendation) and fixing with anchor resin grout
Lokfix P / Lokfix E 75/55/35 series or Emfix or pure epoxy resin based cartridge form chemical
anchor material or Masterflow 935 of BASF or equivalent as per NF P 18-831 and NF P 18-
836. Drilling hole for diameter: 14 mm, Drilling hole for depth: 100 mm including cleaning,
cutting, fabricating, chemicals, material, labour, tools, temporary supports for structures,
electricity, plant and machineries etc. complete as directed by Engineer-in-charge and/or
consultant for all heights | 180 | 1 nos | 290.56 ₹52,300.80 | 290.56 ₹52,300.80 |
| 1.01 | OD122532/2024-2025:Epoxy Injection Grouting:
Providing and executing injection/pressure grouting in cracks in the parent concrete by fixing
PVC perforated nozzles at 150 mm to 200 mm distance or specified distances as per design and
detailed specifications. Pressure grouting using low viscous epoxy grout Conbextra EP10M of
Fosroc or Masterinject 1315 of BASF or Shaligroput EI or equivalent having mix density 1050
kg/m3, Compressive Strength (ASTM D695)->50 N/mm2,Tensile Strength (ASTM C 304-97)-
18 N/mm2, Flexural strength(BS 6319 Part 4)-45 N/mm2 Pressure grouting shall be done at
required pressure at all heights, including all material, labour, tools, temporary supports for
structures, plant and machineries, curing etc. complete as directed by Engineer-in-charge
and/or consultant. | 380 | per kg | 2,035.09 ₹7.7 L | 2,035.09 ₹7.7 L |
| 1.01 | OD122531/2024-2025:Galvanic Sacrificial Prevention of steel by Point anodes:
Providing and fixing sacrificial zinc anode to prevent initialization of corrosion of
reinforcement in adjoining sound concrete due to chloride ingress by installing anodes from
VECTOR Galvashield XPI or equivalent for patches at Min. 2 to 4 anodes / Sq.mt. area of
concrete (spacing of 300 to 700mm), as per manufacturer specification, covered with mortar
with of resistivity less than of parent concrete on the cleaned reinforcement steel including
design from manufacturer, installation of Monitoring Box to measure current thrown by Anode
as per IS 12696 in range of 0.2 to 2mA/ sq.mt as per manufacturers specification before
applying passivation coating at all heights and including of all material, labour, tools, temporary
supports for structures, plant and machineries, etc. complete as directed by Engineer-in-charge
and/or consultant.( for slabs) | 200 | no | 1,397.24 ₹2.8 L | 1,397.24 ₹2.8 L |
| 1.01 | OD122530/2024-2025:Polymer Modified Mortar (Pre-Packed):
Providing and Applying single component, high strength, fibre reinforced, thixotropic
cementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1
day and 45 MPa at 28 days and capable of applying upto 50mm thick in single layer such as
Renderoc SP40 of Fosroc or Master Emaco S 348 of BASF or equivalent, to the prepared
concrete area for thickness up to 50mm, after applying epoxy resin based bonding coat as per
manufacturer?s specification, before the bonding agent becomes tack free, initially by hand
and finally finishing the same with trowel carefully compacting the same around the rebar and
finishing to bring it in line with existing concrete surface on the columns, slabs, beam etc. at all
heights, where the thickness of application is less than 50 mm in patches as per specification .
Item rate is inclusive of all material including the bond coat, labour, tools, temporary supports
for structures, electricity, plant and machineries, curing etc. complete and as directed by
Engineer-in-charge and/or consultant.
(Payment to be made in Sq.M for thickness upto 50mm of PMM for patch area repaired) | 109.56 | sqm | 5,555.75 ₹6.1 L | 5,555.75 ₹6.1 L |
Tender Value
₹33.5 L
EMD Value
₹50,000
Closing Date
16 Mar 2026, 3:00 pmClosed
O/O Executive EngineerPWDBridges DivisionPalakkad
O/O Executive EngineerPWDBridges DivisionPalakkad
GeneralRehabilitation work to Kodumbu causeway situated on Kodumbu Olassery road at km 0200 in Malampuzha LAC -General CivilWork
2026_PWD_845538_1
PWD/BR/TR/19821/2023_5_1_1/1
Open Tender
Civil Works - Bridges
180 days
Kodump
Please refer Tender documents.
11 documents required · 11 mandatory
₹2,760
Yes
₹50,000
Yes
9 Jun 2026
9 Mar 2026
18 Mar 2026
9 Mar 2026
16 Mar 2026
9 Mar 2026
KODUMBU CAUSEWAY REHABILITATION
OD122538/2024-2025:Removing damaged concrete: Loose and delaminated concrete shall be identified and marked before proceeding with the removal. The loose cover concrete including the loose damaged concrete shall be removed upto beyond the corroded bars to a minimum depth of 10 mm behind the reinforcement. Only affected concrete shall be removed and conducting proper investigation, (Good & sound concrete should not be chipped / damaged) by chipping / hacking with chisel and hammer or by mechanical means like light weight chisel hammer, pneumatic chippers, making saw cut at periphery to avoid feather edge for all height and removal and disposal of debris at designated location including all material, labour, tools, temporary supports for structures, electricity, plant and machineries etc. complete as directed by Engineer-in-charge and/or Consultant. Depth of chipping may vary from 20 to 100 mm.
OD122537/2024-2025:Rust remover/Rust Convertor:Cleaning of rust / scales / corrosion from reinforcement bars should be carried out using acid based rust remover, Reebakleens RR of Fosroc or equivalent, or using alkali based rust converters such as Feovert of Krishna Conchem. The material is to be applied to the rusted metal bar, using brush and leaving it to dry for 30 Min. & washing surface with fresh water as required to exposed reinforcement bar at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries complete as per detail specification and as directed by Engineer-in-charge and/or Consultant. The concrete surface area containing the cleaned rebars shall be measured for payment.
OD122536/2024-2025:Anti Corrosive treatment to Steel:Providing & applying inhibition coats/system to exposed reinforcement bars & also new bars,after cleaning & removing scales and rust completely as specified in 1.4, Two component inhibitor Nitozinc Primer std. of Fosroc or MasterEmaco P130 of BASF or equivalent having specific gravity of 1.75 and solid content 57(+/-3) Adhesive bond strength > 1.5 N/mm2, 40 microns DFT per coat as approved by Engineer-in-charge and/or Consultant shall be used as per manufacturer?s specification in two coats at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, necessary surface preparation and necessary protection after and during work. The concrete surface area contianing the rebars where the treatment is carried out shall be considered for measurement
OD122535/2024-2025:New/Additional steel Reinforcement: Supplying, cutting, fabricating new reinforcement Fe500 for Jacketing, and providing additionalsteel reinforcement to compensate corroded reinforcement in existing member etc. and fixing with old existing reinforcement which was reduced to 15 % or more of its original diameter as required as provided in original structure and additional steels as directed by EIC and/ or consultant as required tying with 16 gauge annealed binding wire complete as per drawing and specifications for all heights including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete as directed by Engineer-incharge and/or consultant (TMT BARS of various size as required)
OD122534/2024-2025:Anchoring mainsteel and stirrups: Drilling holes of min 4mm larger than new rebar diameter into existing concrete substrate for anchoring of new rebar and depth of Min. 10 times the diameter of rebar and fixing with anchor resin grout Lokfix E (35/55/75) series or Lokfix P or Emfix or chemical anchor material or Masterflow 935 of BASF or equivalent as per NF P 18-831 and NF P 18-836 includingcleaning, cutting, fabricating, chemicals, material, labour, tools, temporary supports forstructures, electricity, plant and machineries etc. complete as directed by Engineer-in-chargeand/or consultant for all heights
OD122533/2024-2025:Anchoring Steel & Shear Connectors: Drilling holes into existing concrete structure for anchoring of new rebar with 10 mm dia. shear connectors at 0.5 Mt. c/c (or as per design recommendation) and fixing with anchor resin grout Lokfix P / Lokfix E 75/55/35 series or Emfix or pure epoxy resin based cartridge form chemical anchor material or Masterflow 935 of BASF or equivalent as per NF P 18-831 and NF P 18- 836. Drilling hole for diameter: 14 mm, Drilling hole for depth: 100 mm including cleaning, cutting, fabricating, chemicals, material, labour, tools, temporary supports for structures, electricity, plant and machineries etc. complete as directed by Engineer-in-charge and/or consultant for all heights
OD122532/2024-2025:Epoxy Injection Grouting: Providing and executing injection/pressure grouting in cracks in the parent concrete by fixing PVC perforated nozzles at 150 mm to 200 mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout Conbextra EP10M of Fosroc or Masterinject 1315 of BASF or Shaligroput EI or equivalent having mix density 1050 kg/m3, Compressive Strength (ASTM D695)->50 N/mm2,Tensile Strength (ASTM C 304-97)- 18 N/mm2, Flexural strength(BS 6319 Part 4)-45 N/mm2 Pressure grouting shall be done at required pressure at all heights, including all material, labour, tools, temporary supports for structures, plant and machineries, curing etc. complete as directed by Engineer-in-charge and/or consultant.
OD122531/2024-2025:Galvanic Sacrificial Prevention of steel by Point anodes: Providing and fixing sacrificial zinc anode to prevent initialization of corrosion of reinforcement in adjoining sound concrete due to chloride ingress by installing anodes from VECTOR Galvashield XPI or equivalent for patches at Min. 2 to 4 anodes / Sq.mt. area of concrete (spacing of 300 to 700mm), as per manufacturer specification, covered with mortar with of resistivity less than of parent concrete on the cleaned reinforcement steel including design from manufacturer, installation of Monitoring Box to measure current thrown by Anode as per IS 12696 in range of 0.2 to 2mA/ sq.mt as per manufacturers specification before applying passivation coating at all heights and including of all material, labour, tools, temporary supports for structures, plant and machineries, etc. complete as directed by Engineer-in-charge and/or consultant.( for slabs)
OD122530/2024-2025:Polymer Modified Mortar (Pre-Packed): Providing and Applying single component, high strength, fibre reinforced, thixotropic cementitious patch repair mortar that achieves compressive strength minimum of 15 MPa at 1 day and 45 MPa at 28 days and capable of applying upto 50mm thick in single layer such as Renderoc SP40 of Fosroc or Master Emaco S 348 of BASF or equivalent, to the prepared concrete area for thickness up to 50mm, after applying epoxy resin based bonding coat as per manufacturer?s specification, before the bonding agent becomes tack free, initially by hand and finally finishing the same with trowel carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface on the columns, slabs, beam etc. at all heights, where the thickness of application is less than 50 mm in patches as per specification . Item rate is inclusive of all material including the bond coat, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete and as directed by Engineer-in-charge and/or consultant. (Payment to be made in Sq.M for thickness upto 50mm of PMM for patch area repaired)
OD122529/2024-2025:Microconcrete Reinstatement for thickness more than 50mm for RCC members:- Providing and laying of special repair material micro-concrete for reinstatement of members having thickness of repair more than 50mm and jacketing, using Single component, high strength, high flow cementitious micro-concrete having compressive strength minimum of M40 at 28 days such as MasterEmaco 346 or Renderoc RGL / RGS of Fosroc or equivalent, blended with washed saturated surface-dry (SSD), graded, low absorption, high density, aggregates of size 3mm to 10mm at 50% by weight of micro concrete (if thickness is 100mm or more) and water as per data sheet and pouring into the shuttering if required than use birds beak type form work using suitable arrangement or if required using pumping device for uniform flow of Microconcrete. The side shuttering can be removed after Minimum of 24 hours, preferably 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate at all heights, including all material, labour, tools, temporary supports for structures, electricity, plant and machineries, curing etc. complete as directed by Engineer-in-charge and/or consultant. (Payment shall be made in Sq.M for thickness upto 100mm of Microconcrete of area repaired, ) including
12.8.2.C:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> RCC Grade M20 - With Batching Plant, Transit Mixer and Concrete Pump - ( Without formwork) <br>
OD122528/2024-2025:Providing and fixing double scaffoldingsystem(cup lock type)on the exterior side,upto seven story height made with 40mm dia M.S tube
13.3:Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical Specifications
APPENDIX -B
8.4.12:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminum sheeting, 2 mm thick/aluminum composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. 50cmx 60 cm rectangular (Single chevron etc.)
3.1:Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.
12.4:Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
12.8.1.C:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications <br> RCC Grade M20 - Using Concrete Mixer - (Without formwork) <br>
OD337824/2025-2026:Engaging man Mazdoor (Coolie) for clearing and removing all the debris from the periphery of site
8.8:Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
16.18:Replacement of Damaged Concrete Railing.
16.22:Repair of RCC Railing : Carrying out repair of RCC m30 railing to bring it to the original shape.
14.6:Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1428135.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.70 MB
BOQ_1428135.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid